FL #
FL33818-RO
Application Type
New
Code Version
2020
Application Status
Approved
Comments
Archived
f'a Dy
Product Manufacturer
Gulf Coast Supply & Manufacturing, LLC.
Address/Phone/Email
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-0778 Ext0565
jared.pearce@gulfcoastsuppiy.com ZG76'G
Authorized Signature
Jared Pearce
�d,
jared.pearce@guifcoastsupply.com O Itt
b�
�J
`'v6
Technical Representative
Address/Phone/Email
2,W S - o i{S1
REVIEWED FOR
Quality Assurance Representative
CODE COMPLIANCE
Address/Phone/Email
ST. LUCIE COUNTY
Category
Roofing BOCC
Subcategory
Metal Roofing ��LLV
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Steven M. Urich, PE
lei Validation Checklist - Hardcopy Received
Certificate of Independence FL33818 110 COI GCS 000 a 2020 Fe —Evil Metal Roofing NonHVHZ
haRLP&
Referenced Standard and Year (of Standard) i5tandard Year
ASTM B 117 2016
ASTM G 155 '2013
FM 4471 1992
https://www.floridabuilding.org/pr/pr_app—dtl.aspx?param=wGEVX...2YOPr4PF4dQoT5r%2fFA9th%2fha%o2b7jjUUQKUnMLX1o1ESECSIK6g%3d%3d Page 1 of 3
Florida Building Code Online
3114/22, 3:39 PM
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Cmimmane ni Drnelur4a
TAS 100
1995
TAS 110
2000
TAS 125
2003
UL 1897
2012
UL 580
2006
Method 1 Option D
10/11/2020
10/31/2020
11/05/2020
1Z/16/2020
04/13/2021
FL #
Model, Number or Name
Description
33818.1
Metal Roofing Systems (HVHZ)
GulfLok, VersaLoc, 5V Crimp, GulfPBR and GulfRib
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL33518 RO Z�G- C520002b ?020 FBC );v-al Metal Roofing
HVHZ finaLp-d
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-164.25
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL33818 RO AE GCS20002b 2020 FBC Evai Metal Roofing
HVHZ final.p-df
Created by Independent Third Party: Yes
33818.2
Metal Roofing Systems (nonHVHZ)
Gulkok, GulfSeam, MegaLoc, VersaLoc, 5V Crimp, GulfPBR,
GulfRib and GulfWave
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL33818 R _H GCS20002a 2020 FBC Eval Metal Roofing
NonHVHZ final.pd
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-164.25
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL33818 RO AE GC520002a 2020 FBC (<yal Metal Roofing
NonHVHZ final.gdl
Created by Independent Third Party: Yes
Sack —7
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 650-407-1924
The State of Florida Is an AA(EEO employer, CoRyHaht 2007-2013 State of Florida.:: Privacy Statement :: Axessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this enilty. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487,1395. *Pursuant to Section
45S.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
,one. The emalis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please dick bgrg.
Product Approval Accepts:
FM M 9 R] K
https://www.floridabuilding,org/pr/pr_app_dtl.aspx?param=wGEVX...2YOPr4PF4dQoT5r%2fFA9th%2fha%2b7jjUUQKUnMLX1o11 SECSIK6g%3d%3d Page 2 of 3
` rmHNICAL SERV'iCES9 LLC
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7"" EDITION (2020)
Manufacturer:
Manufacturing Locations:
Quality Assurance:
SCOPE
GULF COAST SUPPLY &
14429 SW 2'd Place, Suite
:Newberry, FL 32669
(352) 498-7852
wwjulfcoastsugply.com
Alachua, FL
Sebring, FL
Montgomery, AL
MANUFACTURING, LLC Issued October22, 2020
G30
Keystone Certifications, Inc. (QUA1824)
Category: Roofing
Subcategory: Metal Roofing
Code Edition: Florida Building Code, 7th Edition (2020) High -Velocity Hurricane Zones (HVHZ)
Code Sections: '1518.9.1, 1523.1.1, 1523.6.5, 1523.6.5.2.4, 1523.6.5.2.4.1
Properties: Wind Resistance
REFERENCES
EntiRenort
No.Reno
Standard
Year
Architectural Testing, Inc. (TST1527)
B9000.01-450-18
TAS 125
2003
Farabaugh Engineering & Testing, Inc. (TST1654)
T126-07
TAS 100
1995
Farabaugh Engineering & Testing, Inc. (TST1654)
T128-07
TAS 100
1995
Farabaugh Engineering & Testing, Inc. (TST1654)
T129-07
TAS 100
1995
Farabaugh. Engineering & Testing, Inc. (TST1654)
T130-07
TAS 100
1995
Farabaugh Engineering & Testing, Inc. (TST1654)
T132-07
TAS 100
1995
Farabaugh Engineering & Testing, Inc. (TST1654)
T215-08
TAS 100
1995
Farabaugh Engineering & Testing, Inc. (TST1654)
T270-08
TAS 100
1995
Farabaugh Engineering & Testing, Inc. (TST1654)
T271-08
TAS 100
1995
Farabaugh Engineering & Testing, Inc. (TST1654)
T272-08
TAS 100
1995
Farabaugh Engineering & Testing, Inc. (TST1654)
T273-08
TAS 100
1995
Farabaugh Engineering & Testing, Inc. (TST1654)
T356-10
TAS 100
1995
Force Engineering & Testing (TST5328)
72-0313T-06A-C
TAS 125
2003
Force Engineering & Testing (TST5328)
72-0198T-07A-C
TAS 125
2003
Force Engineering & Testing (TST5328)
117-0062T-07A-C
TAS 125
2003
'Force Engineering & Testing (TST5328)
117-0062T-07D-F
TAS 125
2003
Force Engineering & Testing (TST5328)
117-0062T-07G-1
TAS 125
2003
Force Engineering & Testing (TST5328)
117-0062T-07J-L
TAS 125
2003
Force Engineering & Testing (TST5328)
117-0065T-07A C
TAS 125
2003
Force Engineering & Testing (TST5328)
117-0238T-09D
FM 4471
1992
Force Engineering & Testing (TST5328)
117-0238T-09E
FM 4471
1992
Force Engineering & Testing (TST5328)
117-0238T-11A
FM 4471
1992
Force Engineering & Testing (TST5328)
117-0378T-11A
FM 4471
1992
Force Engineering & Testing (TST5328)
117-0378T-11 B
FM 4471
1992
Force Engineering & Testing (TST5328)
117-0378T-11C
FM 4471
1992
PRI Construction Materials Technologies (TST5878)
HTL-018-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
1272T0002
ASTM B 117
2016
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
1272T0003
ASTM B 117
2016
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
1272T0005
ASTM G 155
2013
TAS 110
2000
GC820002b FL33818 Pane 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
.Entity
PRI Construction Materials Technologies (TST5878)
PRODUCT DESCRIPTION
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing (HVHZ)
Report No. -Standard Year
1272T0006 ASTM G 155 2013
TAS 110 2000
Gulfl-ok
Profile:
1 in. snap lock seam; Max.16 In. coverage
Description:
Non-structural, sna lock standing seam roof panel with 7/8 in. slotted nail strip
Material:
Min. 26 ga. ASTM A792 AZ50 coated with Florupon@ or ASTM A653 G90;
F = min. 50 ksl; Shall conform with FBC Section 1507.4.3
12" and 16" Coverage
Versal-or,
Profile:
1,5 in. mechanical seam; Max. 18 in. coverage
Description:
Non -'structural, mechanical lock 1800 standing seam roof panel,
Material:
Min. 24 ga. ASTM A792 AZ50 coated with Florupon® or ASTM A653 G90;
F = min. 50 ksi; Shall. conform with FBC Section 1507.4.3
tb"•18`Covarage
5V Cri
Profile:
7/16 in, ribs at 12 in. o.c.; 24 in. coverage
Descri lion:
Non-structural, through fastened roof panel_
Material:
Min. 26 ga. ASTM A792 AZ50 coated with Florupon® or ASTM A653 G96;
Fy = min.,50 ksi; Shall conform with FBC Section 1507.4.3
Min. 0.032 in. ASTM B209, 3105 H24 aluminum; Optional Florupon® paint finish;
F = min, 25 ksi; Shall conform with FBC Section 1507.4.3
12•
24" Coverage
GuIfPBR
Profile: 1 1/4 in. ribs at 12 in. o.c.; 36 in. coverage
GCS20002b FL3381a Pace 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid,
This evaluation report does not express nor imply warranty, installation, recommended use, or'other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL. SERVICES, LLC
GULF COAST SUPPLY & MANUFACTURING, LLC
'Metal Roofing (HVHZ)
Description:
Non-structural, through fastened roof panel
Material:
Min, 26 ga. ASTM A792 AZ50 coated with Florupon@ or ASTM A653 G90;
F = min. 80 ksi; Shall conform with FBC Section 1507.4.3
1114� � 2,r
36Coverage
GulfRib
Profile:
3/4 in. ribs at 9 in. o.c.; 36 in. coverage
Description:
Non-structural, through fastened roof panel
Material:
Min. 29 ga. ASTM A792 AZ60 coated with Florupon® or ASTM A653 G90;
B0 ksi; Shall conform with FBC Section 1507.4.3
3/4",� 9°
36" Coverage
GC8._20002b_ FL33818 . Pane 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
u, CREEK
TECHNICAL SERVICES, LLC
LIMITATIONS
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing (HVHZ)
1. Fire classification is not within the scope of this evaluation.
2. The roof deck and the roof deck attachment information are provided based on testing. FBC requirements
for the rational design of the roof deck, including the attachment, are not within the scope of this
evaluation.
3. Roof slope shall be 2:12 or greater,
4. Reroofing shall be in accordance with Section 1521.
5. Installation of the evaluated products shall comply with this report, RAS 133, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
6. All products; listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7t' Edition (2020) High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted
'by the named manufacturer.
• No 74021
•: STATE OF : ill:
., �S.0 p R ♦ .
E�Ca
Zachary R. Priest, P.E.
'Florida Registration No. 74021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A — Installation (3 pages)
2) APPENDIX B — Approved Roof Systems (4 pages)
3) APPENDIX C — Design Wind Loads (3 pages)
GCS20002b FL33818 .Pane 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
TECHNICAL SERVICES, LLC
CREEK
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing (HVHZ)
APPENDIX A
INSTALLATION.
Note - Refer to the APPRouED RooF SYsrgAis section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Component
Product
Installation Detail
#9-15 HWH wood screw
with sealing washer
#9-15 HWH WoodZAC
screw
Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion
#10-12 Pancake Type A
screw
Fasteners
resistant in accordance with FBC section 1507.4.4,
#12-11 Pancake Type A
screw
114-14 HWH ZAC Impax
Installed at panel side lap: Shall be corrosion resistant in accordance with FBC
Lap screw
section 1507.4.4.
24 ga. inseam clip
1/4
Gulfl-ok Clip
Clips
0.78
4-1/4"
_. -- - - - -
2"
NC-33003-3 Sliding Clip
1/2"
Sealants
TiteBond Weathermaster
Metal Roof Sealant
Shall be applied in 1/4"- 5/16" continuous beads on the male rib along the seem
GCS20002b FL33818 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express not imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREED
TECHNICAL SERVICES, LLC
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Rooting (HVHZ)
APPENDIX A
Fastening Details
Nomenclature
Attachment
— MAX.16" COVERAGE
GulfLok Type 1
(1) #10-12 X 1° TYPE A PANCAKE
Gullok'm CLIP 24 GA.
Gulf-ok Type 2
(1) #10-12 X V TYPE A PANCAKE
Max. 18"
VersaLoc Type 1
Acq
r
V-15a0SCSUDlNGCUP
(2) #12-11 x 1" Panhead per Clip
(1) #9-15 x 1-1/2" HWH Irv/Sealing Washer
5V Type 1
1211-1211-�,
At Panel Lap ---/
At Panel Lap
#1/4-14 x 7/80 Lap Screw @ 24' O.C. Max.
GulIPBR Type 1
12" 12" 12"
(1) ##9-15 x 1-1/2'
GCS20002b FL33818 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
::u. CREEK
TECHNICAL SERVICES, LLC
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature
Attachment
#1/4-14 x 7/8" Lap Screw @ 24" O.C. Max.
11 11 11 11
GuliPBR Type 2
J ! 55 I
-T, I
'I
(1) #9-15 x 1-1/2"
911 At Panel Lap
GulfRib Type f
Z(1) #9-16 x 1.1/2' w/Sealer Washer
1-6,511—T2.5" T-6.5n 7 2.5" f 6.5" 2.5"1-- ti, 5" —{- 2.5"
GulfRib Type 2
Z(1) #9.15 x 1-1/2' w/Sealer Washer
GCS20002b FL33818 Paae 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
APPROVEo ROOF SYSTEMS
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing (HVHZ)
APPENDIX B
The following notes shall be observed when using the assembly tables below.
1. Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1523.4.
2. Refer to LlmrrATIONS and sections of this evaluation when using the table(s) below.
3. Refer'to INsrALLA'noN section of this report for installation detail when the -information is not explicitly stated for the selected assembly.
4.. The on -center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system.
5. Underlayment shall be installed in accordance with. FBC requirements. The minimum underlayment shall be ASTM D 226, Type 11 installed as described
in FBC Section 1518.2.1 with nails and tin caps per 1517.5.
6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy = min.40 ksi) Wide Rib Deck (Type WR)
conforming to ANSI/SDI-RD1.0 & FBC. In no case shall the panels be installed on less than two continuous spans, which are spaced a maximum 5-ft o.c.
At minimum, the deck shall be attached with one (1) #12 x 1.5-inch HWH self -drilling screws at the bottom of each flute (maximum. 6-inch o.c. along the
support). At minimum, the deck side laps shall be fastened a maximum 6-inch o.c. with #12 x 1.54nch HWH self -drilling screws.
7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 19/32-inch thick APA Span -Rated plywood
sheathing or wood plank at maximum 24-inch span for new construction. Existing construction shall be the minimum plywood sheathing or wood plank
thickness at maximum 24-inch span as stated in the approval tables on following pages. In no case shall the attachment be less than 8d ring shank nails
spaced 6-inch o.c.
Roof System Numbers and Definitions
LOK W#
GulfLok over Wood Deck New or EAstin
Y—L-W#
1.5" VersaLoc over Wood Deck new or Existing)
5V-W9
5V Crimp over Wood Deco New or Bdstin
PBR-W#
GUIIPBR over Wood Deck New or Existin
RIB-W#
GulfRib over Wood Deck New or Existing)
Approved Systems for GUIfLok over Wood Deck (New or Existing)
System
No.
Deck
Fire Barrier
Undedayment
Roof Panel
Panel Attachment
MDP
(psf)
LOK-W-1
Min. 15132
OPTIONAL
Approved fire barrier
As required per FBC
26 ga., Grade 80 GulfLok.
GultLok Type 1 attachment #10-12 x 1"
ma's
B C plywood
or insulation
Max.16-inch coverage
Pancake Type A screws spaced 5-3/16 in. o.c
OPTIONAL
GUIfLok Type 1 attachment with #10-12 x V
LOK W 2
Min.15/32
Approved fire barrier
As required per FBC
Min. 26 ga. GulfLok
Pancake Type A screws spaced 5-3/16 in. o.c.
_121.75
CDX plywood
or insulation
Max. 16-inch coverage
Tdebond Weathermaster Metal Roof Sealant
applied to male rib.
LOK W-3
Min.15/32
B-C plywood
OPTIONAL
Approved fire barrier
As required per FBC
26 ga., Grade 80 GulfLok
Max. 164nch coverage
GuIlLok Type 2 attachment with
#10-12 x 1" Pancake Type A screws through
461
or insulation
clip and spaced 5,V16 in. o.c.
GCS20002b FL33818 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing (HVH2)
APPENDIX B
Approved Systems for VersaLoc over Wood Deck (New or Existing)
System
No.
Deck
Fire Barrier
Underlayment
Roof Panel
Panel Attachment
MDP
(psf)
VL W 1
Min. 15/32
OPTIONAL
Approvedfire barrier
As required per FBC
Min. 24-ga. VersaLoc
VersaLoc Type #attachment
-59.75
&C plywood
or insulation
Max.164nch.coverage
with clips spaced 24 in. o.c.
VL-W-2
Min.15132
OPTIONAL
Approved fire barrier
As required per FBC
Min. 24 ga. VersaLoc
VersaLoc Type 1 attachment
423.5
B-C plywood
or insulation
Max 16-inch coverage
with clips spaced 6 in. o.c.
Approved Systems for 5V Crimp over Wood Deck (New or Existing)
System
Deck
Fire Barrier/
Urtderiayment
Roof Panel
Panel Attachment
MDP
No
Insulation
(Psi
5V-W1
Min. 15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. 5V Crimp
5V Crimp Type 1 attachment with-#R9-15 HWH wood
408S
B-C plywood
or insulation
244nch coverage
screws with sealing washers spaced 12 in. o.c.
5V_V 2
Min.15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. 5V Crimp
5V Crimp Type 1 attachment with #i9-15 HWH wood
456.5
B-C plywood
or insulation
244nch coverage
screws with sealing washers spaced 6 in. o.c.
Approved Systems for GulfPBR
over Wood Deck (New or Existing)
System
Deck
Fire Barrier/
Underayment
Roof Panel
Panel Attachment
MDP
No.
Insulation
(psf)
OPTIONAL
GulfPBR Type 1 attachment with #19-1515 HWH WoodZAC
PBR W 1
Win.15132
Approved fire barrier
As required per FBC
Min. 26 ga. GuIfPBR
screws spaced 24 in. o.c.
-60.5
B-C plywood
or insulation
36-inch coverage
Laps fastened with 1/4-14 x 7/8' HWH ZAC Impax Lap
screws spaced 24 in. o.c.
GCS20002b FL33818 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
:. CREEK
TECHNICAL SERvicEs, LLC
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing (HVHZ)
APPENDIX B
Approved Systems for GuIfPBR
over Wood Deck (New or Existing)
System
Deck
Fire Barrier/
Underlayment
Roof Panel
Panel Attachment
MDP
No.
Insulation
(psfl
Min. 1x4 No. 2
SYP wood
purlins spaced
OPTIONAL
GulfPBR Type 1 attachment with #9-15 HWH WoodZAC
PBR W-2
24 in. o.c.
Approved fire barrier
As required per FBC
Min. 25 ga. GdfPBR
364nch coverage
screws spaced 24 in. o.c. into wood purlins
Laps fastened with 1/4-14 x 7/8.ZAC Impax Lap screws
_100.5
over
or insulation
spaced 24 in. o.c.
Min. 15/32
B-C plywood
Min. 1x4 No. 2
SYP wood
purlins spaced
OPTIONAL
GuNPBR Type 2 attachment with #9-1515 HWH-
PBR-W-3
12 in. o.c.
Approved fire barrier
As required per FBC
Min. 26 ga. GuIfPBR
WoodZAC screws spaced 12 in. o.c_ into wood purlins
451.75
over
or insulation
364nch coverage
Laps fastened with 114-14 x 7/8" HWH ZAC Impax Lap
Min. 15/32
screws spaced 24 in. o.c.
B-C plywood
OPTIONAL
Gu#PBR Type 2 attachment with #9-15 HWH WoodZAC
PBR W-4
Min. 15/32
B-C plywood
Approved fire barrier
As required per FBC
Min. 26 ga. Gu1fPBR
364nch coverage
screws spaced 12 in. o.c.
Laps fastened with 1/4-14 x 718" HWH ZAC'Irhpax Lap
-154.75
or insulation
screws spaced 24 in. o.c.
Approved Systems for GulfRib
over Wood Deck
(New or Existing)
System
Deck
Fire Barrier/
Underiayment
Roof Panel
Panel Attachment
MDP
No.
Insulation
(psfl
Rt6 W-1
MGn.15M
OPTIONAL
Approved fire barrier
As required per FBC
Min. 29 ga. GulfRib
GuMb Type f attachment with # with #9-15 HWH
-71.75
C plywood
or insulation
364nch coverage
WoodZAC screws spaced 24 in. o.c
Min. 1x4 No. 2
SYP wood
RIB-W-2
purlins spaced .
24 in. o.c.
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. GUIfRib
Guffft Type 1 attachment with #9-15 HWH WoodZAC
406.75
over
or insulation
36-inch coverage
screws spaced 24 in. o.c. into wood purlins
Min. 15/32
B-C plywood
GCS2Q0t)2b FL33818 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G2D-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing (HVH2)
APPENDIX B
Approved Systems for GulfRib
over Wood Deck
(New or Existing)
System
Deck
Fire Barrier!
Underiayment
Roof Panel
Panel Attachment
MDP
No.
Insulation
(pso
RIB W3
Mrn.15/32
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. GulfRib
GulfRrb Type2 attachment with #9-15 HWH WoodZAC
759.25
B-C plywood
or insulation
36-inch coverage
screws spaced 12 in. o.c.
Min.1x4 No. 2
SYP wood
RIB-W-4
purlins spaced
12 in. o.c.
OPTIONAL
Approved fire barrier
As required per FBC
Min. 26 ga. GulfRib
GulfRrb Type 1 attachment with #9-15 HWH WoodZ4C
-164.25
over
or insulation
36 inch coverage
screws spaced 12 in. o.c. into wood purlins
Min.15/32
B-C plywood
GC820002b FL33818 Page 4 of.4
This evaluation report is provided for State of Florida product approval under Rule 61 G20.3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
DESIGN WIND LOADS
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing (HVHZ)
APPENDIX C
The following tables provide design wind loads for components and cladding in accordance with -Section 1620 of the FBC and ASCE 7-16 under the following
provisions:
1. Wind speeds for risk category 1, Ili III, and IV buildings shall be as defined in Section 1620 of the FBC.
2. Exposure C and D shall be as -defined in section 1620 of the FBC.
3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1 `12
4. All calculations are based on an effective wind area of 1041? or less.
5. 'Topographic factors such as escarpments or hills have been excluded from the analysis
6. Overhangs have been excluded from the analysis.
7.. Wind directionality factor, Kd = 0.85
8. Design wind loads are calculated using:Psd = 0.6P„ K.
9. Zone 2 is inclusive of Zone 2e, Zone 2n, and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11.. Projects with mean roof heights greater than 60ft shall be evaluated by a licensed design professional
12. Zones 1, 2, and 3 shall be defined as shown below. Dimension "a" shall be 10% of the least horizontal dimension or'(0.4 x Mean Roof Height), whichever
is smaller, but not less than either 4% of the least horizontal dimension or 3ft
Gable Hip
�N
3 2
2 1 2
�o2 1 2
GCS20002b FL33818 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing (HVHZ)
:-.... :.. Gab
eMi "Roofs-rn x
--
sure' n:M a " - ade & -BrdWard Coun Roof:sl es etween :12 and 12
Biildmg-Type
Zone
Mean Roaf
Height (it) -
"`
Basic Wind S eii m' h ` =' - .-
Rrsk-C'at l
Rrsk:Cat I
Risk Cat ll' " `
Risk Cat 11
, 'Risk.Cat-IIL N :
Rrsk:Cat.111 IV .:
.' 156: '.
:. -"165 ::.
`'170_. .'
175` ,.
'-180
Enclosed/
Partially Open
1
20
-62.3
-69.7
-74.0
-78.5
-83.0
-88.6
25
-6 i.1
-72.8
-77.3
-81.9
-86.7
-92.6
30
-67.9
-75.9
-80.6
-85.4
-90.4
-96.5
40
-72.0
-80.6
-85.6
-90.7
-95.9
-102.4
50
-75.5
-84.5
-89.7
-95.0
-100.5
-107.3
60
-78.3
-87.6
-93.0
-98.5
-104.2
-111.3
2
20
-90.9
-101.7
-108.0
-114.4
-121.1
-129.3
25
-95.0
-106.3
-112.8
-119.5
-126.5
-135.0
30
-99.0
-110.8
-117.6
-124.6
-131.8
-140.8
40
-105.1
-117.6
-124.8
-132.2
-139.9
-149.4
50
-110.1
-123.2
-130.8
-138.6
-146.6
-156.6
60
-114.2
-127.7
-135.6
-143.7
-152.0
-162-3
3
20
-108.1
-120.9
-128.4
-136.0
-143.9
-153.7
25
-112.9
-126.3
-134.1
-142.1
-150.3
-160.5
30
-117.7
-131.7
-139.8
-148.1
-156.7
-167.3
40
-124.9
-139.7
-148.3
-1572
-166.3
-177.6
50
-130.9
-146.5
-155.5
-164.7
-174.3
-186.1
60
-135.7
-151.8
-161.2
-170.8
-180.7
-192.9
Partially
Enclosed
1
20
-72.9
-81.6
-86.6
-91.8
-97.1
-103.7
25
-76.2
-85.2
-90.4
-95.8
-101.4
-108.3
30
-79.4
-88.8
-94.3
-99.9
-105.7
-112.9
40
-84.3
-94.3
-100.1
-106.0
-112.2
-119.8
50
-88.3
-98.8
-104.9
-111.1
-117.6
-125.5
60
-91.6
-102.4
-108.7
-115.2
-121.9
-130.2
2
20
-101.5
-113.6
-120.6
-127.8
-135.2
-144.3
25
-106;0
-118.6
-125.9
-133.4
-1412
-150.7
30
-110.5
-123.7
-131.3
-139.1
-147.2
-157.1
40
-117.3
-131.2
-139.3
-147.6
-156.2
-166.8
50
-123.0
-137.5
-146.0
-154.7
-163.7
-174.8
60
-127.5
-142.6
-151.4
-160.4
-169.7
-181.2
3
20
-118.7
-132.8
-140.9
-149.3
-158.0
-168.7
25
-124.0
-138.7
-147.2
-156.0
-165.0
-176.2
30
-129.2
-144.6
-153.5
-162.6
-172.0
-183.7
40
-137.1
-153.4
-162-9
-172.6
-182-6
-195.0
50
-143.7
-160.8
-170.7
-180.9
-191.4
-204.3
60
-149.0
-166.7
-177.0
-187.5
-198.4
-211.8
GCS20002b FL33818 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are riot specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing IHVHZ)
APPENDIX C
. �._:= _ "�-_ '•" :.- "�``Gabie/Hi
:Roofs"in`Ex ..' reDinMiamI=Dade�&;Bto�riard:Goun ": Roof io".." °fietween212"a"itd:1Z72 `�..
Bnldusg Type
=:
Zone
'_.-'
Mean Roof ; {
r •
lie�gfrt (ii)
Bastc Wing S ad,(
RiskCaf-f
r= Risk Cat I
Risk Ca# 11
Risk Cat 11
:Risk Cat 111 IV -
Wsk Cat III IV,,-`
�=180
Enclosed/
Partially Open
1
20
-74.8
-83.7
-88.8
-94.1
-99.6
-106.3
25
-77.6
-66.8
-92.1
-97.6
-1033
-110.3
30
-80.4
-89.9
-95A
-101.1
-107.0
-114.2
40
-84.5
-94.5
-100.4
-106.3
-112.5
420.1
50
-88.0
-98.4
-104.5
-110.7
-117.1
-125.1
60
-90.7
-101.5
-107.8
-114.2
-120.8
-129.0
2
20
-109.1
-122.1
-129.6
-137.3
-145.3
-155.1
25
-113.2
-125.6
-134.4
-142.4
-150.7
-160.9
30
-117.2
-131.1
-139.2
-147.5
-156.0
-166.6
40
-123.3
-137.9
-146.4
-155.1
-164.1
-175.2
50
-128.3
-143.6
-152.4
-161.5
-170.8
-182.4
60.
-132.4
-148.1
-157.2
-166.6
-176.2
-188.2
3
20
-129.7
-145.1
-154.0
-163.2
-172.7
-184.4
25
-134.5
-150.5
-159.7
-169.3
-179.1
-1912
30
-139.3
-155.9
-165.4
-175.3
-185.5
-198.1
40
-146.5
-163.9
-174.0
-184.4
-195.1
-208.3
50
-152.5
-170.6
-181.1
-192.0
-203.1
-216.8
60
-157.3
-176.0
-186.8
-198.0
-209.5
-223.7
Partially
Enclosed
1
20
-87.5
-97.9
-103.9
-110.1
-116.5
-124.4
25
-90.7
-101.5
-107.8
-114.2
-120.8
-129.0
30
-94.0
-105.1
411.E
-118.3
-125.1
-133.6
40
-98.8
-110.6
-117.4
-124.4
-131.6
-140.5
50
-102.9
-115.1
-122.2
-129.5
-137.0
-146.3
60
-106.1
-118.7
-126.0
-133.6
-141.3
-150.9
2
20
-121.8
-136.3
-144.7
-153.3
-1622
-173.2
25
-126.3
-141.3
-150.0
-159.0
-1682
-179.6
30
-130.8
-146.4
-155.4
-164.7
-174.2
-186.0
40
-137.6
-154.0
-163.4
-173.2
-183.2
-195.6
50
-143.3
-160.3
-1.70.1
-180.3
-190.7
-203.6
60
-147.8
-1653
-175.5
-186.0
-196.7
-210.1
3
20
-142.4
-159.3
-169.1
-179.2
-189.6
-202.5
25
-147.7
-165.2
-175.4
-185.8
-196.6
-210.0
30
-153.0
-171.1
-181.6
-192.5
-203.6
-217.4
40
-160.9
-180.0
-191.0
-2024
-214.2
-228.7
50
-167.5
-187.3
-198.9
-210.7
-223.0
-238.1
60
-172.7
-1932
-205.1
-217.4
230.0
-245.6
GCS20002b FL33818 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.