Loading...
HomeMy WebLinkAboutPlan View & landscape- 61 SPACES _@10'-0" = 610'-0' 373'-4 3/16„ 3"0 SCH.20 POST 3'0 SCH.20 TERMINAL POST -- - --- ---- - - - - --- @ EACH END CORNER & AT GATE TERMINAL '\ / 3"0 SCH.20 POST NEW GALVANIZED \`-NEW DOOR (ONE)6'x8' GATE. x CHAIN -LINK FENCE TOTAL OF (3) TYPICAL GATES 00 L EXISTING.FENCE TO REMAIN & TO BE RELOCATED ON PROPERTY o LINE AT EAST SIDE ONLY. n m X 3 1. 0 SCH.20 TERMINAL POST @ EACH END CORNER & AT GATE TERMINAL. r, 0 I M 3,0 SCH.20 3"0 SCH.20 POST o — POST -� 1- .. o \ / - 3"0 SCH.20 N / 3"0 SCH.20 NEW DOOR a NEW DOOR (ONE)6'x8' GATE. POST (ONE)6'x8' GATE POST TOTAL OF (3) TYPICAL GATES. o TOTAL OF 3 -1 TYPICAL GATES) ¢ x 0 N NEW GALVANIZED -� X CHAIN -LINK FENCE x f I I \ - EXISTING FENCE TO NEW GALVANIZED REMAIN. � CHAIN -LINK FENCE J �------ ?---- - x ----- x x x - - ---- x - x --._ ._-_.. x ..._ ...---- x L - s ° �� ° ° ° �----a--�- a- a--o-- 3"0 SCH.20 TERMINAL POST - @ EACH END CORNER & AT GATE TERMINAL. 8' -0, - 242'-0" - — -- -- - — -------- -. - --- 36_SPACES 0 10'=0' _ _360'-0 EXITING FENCE AND ROLLING GATE TO REMAIN - -- 'I PLAN VIEW. GALVANIZED CHAIN LINK FENCE. r , SCALE: 1 /32"-1' -0" VERIFY DIMENSION IN FIELD r CENTER POST TO CENTER POST (CENTER POST TO CENTER POST CENTER POST TO CENTER POSE (3) STANDARDS OF BARBWIRE CONT 3"0 SCH.20 POST @ EACH --` _-- 6'-0 (DOOR WIDTH) ---- GALVANIZED POST 2" 0 GATE TERMINAL AND ALL r- LOCK VdIld SCH.20 (TYPICAL). (4) CORNERS OF FENCE LOCK�'t,LE DEVICE \ �, � _ -.. x- - -- X -___- X `- - - x -- X _.-__"-. x x - - - X - X - X X -__ x _.--- X - - Y� __ -_- x -_- -� x __- __ x --- x -__- x x- — x — x x—...- x- r -._ r x x - x x x— x - — - x-- x-- x X X- - X X X - �_ X i 1 , I I ill 11 li i ! I I ` 9 Ga. GALVANIZED _ FABRIC I--, 9 Ga. GALVANIZED 9 Ga. GALVANIZED FABRIC / FABRIC I I ' I I II ') III I i A, A \, A, .A ��� �� y // o ,� ; �; X� ��yew ;� <,, /i as //\ \ / \\-REGULAR CONCRETE \ / �, 12" DIAM x 3'-6" DEEP. CONCRETE v� v / �� / y �/ �/� COMPRESSIVE STRENGTH TI =2500 PSL - - i v A National C Certii FENCE WITH DOOR. -ELEVATION DETAIL, I T: (305) - EMA NEW GALVANIZED CHAIN -LINK FENCE i - -L 3"0 SCH.20 TERMINAL POST @ EACH END. CORNER & AT GATE TERMINAL. REVIEWED FOR CODE COMPLIANCE S'T. LUCIE/CO TY I3OCC (3) STANDARDS OF _ - BARBWIRE CONT. MI i :-1 GALVANIZED POST 2" 0- SCH.20 (TYPICAL). w o CO i' 9 Go. GALVANIZE[)-- FABRIO 'o . REGULAR CONCRETE 12" DIAM. x S-6° DEEP. / CONCRETE COMPRESSIVE \ STRENGTH TH=2500 PSI. (TYPICAL). No. 54794 N Q STATE OF °@w� 1® Digitally signed by Mohamed W ahmy` Date: 2022.03.15 - 16:57:28-04'00' rn i x 0 SECTION FENCE SCALE 112°4-0° DETAIL NOTES: 1. NO ELECTRIC GATES/ MOTORS, 2. GALVANIZED CHAIN -LINK FENCE PIPE WITH 9 GAUGE FABRIC 8'-0" TALL WITH 3 LINES OF BARB AT THE TOP. 3. (1)KNOX LOCK TO BE INSTALLED Q ROLLING GATES ONLY Z (3/15/2022) REVISION ZL . (3/11 /2022) REVISION / n II. li III 01 REARDEN STEEL MANUFACTURING LLC j I I I .. .V1 L1L L1—_—_11 LI PARCEL: 1430-322-0001-010-3 1_____ L____ 1_____L , I ------- -----j------- ,-------� FUTURE LAND USE: MXD' ZONING: IL 15.00' WIDE FPUA EASEMENT \ r n PER ORB. 765, PG. 226 , I, LE, I ..... ..d,tr110 I. �k� {0/ ',,.il; `nNf.w ir i I I STELL BOULEVAIRD EXISTING POWER POLE TO BE RELOCATED (LOCATION TO BE DETERMINED AT A (PRIVATE ROAD) FUTURE DATE) o_ _ --- - m E --------------------------------------------------------------------------- 7-20-1987 11, � _------------------------------------ 'TOPPROP. DRAINFIELD AND SEPTIC TANKS ORB 550/ PG 2208 o PROP. WATER 3-28 1985 24" BAR METER & RPZ ORB 461/ PG 70 _-owE-.. :_owe. ..._owF .._...._flNE r�=wE 1706 1707 1708 ONE ..__ ��:� .._--'orE - ..,,. _,... owE -..:_:.. onE.,...._ „6, 7-.._ cwE... t-t�\.oSHE . OLE .:..... eSE .::. v.1-- r .._ ONE ,. .__._OWE .. .._ ONE `JwE \ / U Ht _ LL -JJ ... \ ✓ I+�� ✓n,: I__I'.. f,'\� ONE \l 9 \ty�'jl'jY�/%/�/. \\\`�III�I�,�/�/, < ' ,,� .� �✓i kf 2 / / ,' ,. _C rmtti , -ewe .' �y • ° • + + + + P d d I + + + ROP. +3.. .,rllinl FDC eH e 1700* 1 T' auai{tax (�# 1701 ry mtP, 5 t. • • `.. .i Q K9x' ..._ .. • Cl.lI,R'RIu...IPT,J 9 rR! - tCryrtxM i.140 x'ERt: HtY M1tlr,pt',y, YyIYttCtn rytHHl NpPi'. CYNrt:titlt:'... HM1 \ Ce O Ih .ttI:I.Lr.:Ai tt^. rN:ri zutmnt ... i � t. �...:. \ �. ". ;... , � s�. � a:t APid:9fPY v � - ... Iitnv lt�•, d.0 LLL... rt' tfnd¢Inxia:Yn:P{!{R�{iPtiilNib9 4 9 9i:t(Mt!iltlt&�Kt�•ir^f'4*tRttti�tlltt 4 n.^.in .. ,. .. k ,,. .IPh , t..txdn 1 tnttYiYao+ov j f —/ ftti a am 4 PROPOSED ,."\ '..1, ° .. .t.. A. „i.• .,, ia'tK@MhiiiACttf Y+a'li]hflxt E+.prti P,Btlq:rp96t9tY4y' ie PittYtY:ItYpl PROP. FPL 1 PAVEMENT" PROPOSED 6" FIRE LINE 03 E x W/ DDCV TRANSFORMER WATER SERVICE 1 - Igpi?6tH:' 9hittYtei dtN!!ttH;l ( , ti!{tC9(py, xtWN rtYtttI. "° hO :ti!Citratr Wetq-R tl:MHPc IFS+i{ " p ��i�(IPty.. IrtE:r1UM ItN{tNM F'iitYi9. t .. t:::x IrirflY,Hx' f�RtNNixi t:{:rtatt ��pm'1I W arnxr t .tt:xvrs!n Pmc;ttn srttcutnl nn:nun{. imxrePn an.±ttnni artsPtt:y , 'rlNiliY.f. Pow°mr liNNi4G' tPtiY4Itt11 MWN,i di0t{!k0V 1Pat1(9RR fFR{Ot@' t4ttt➢lPfrt PNitUtilA. rt{ndC6tYX xBti!iti:i pi199d9x tM+tC trt IifNI8I0tl Wx4 Ht[ Hi tiP. ki N first root prunin l �� 1�, Z - \�� 0 \ O D + © + 6 + LPL Right Tree Right X v A Place 30' :Medium Tree 1 Sec�ndraotpruning offs t v c p TRAILER S O AG A A a E a aaoi Qe a TRAILERS OR G AREA J q —� —� FPl Right Tree Right 71 s I �i llbU/ J Place go' Large Tree wN: - Offset O zo z l\\\° i SANIT ER SERVICE . ELEC./ CLEAN \ , �Q _ _ — D D D c J 171 x AIR COMP. ROOM STORAGE MALE ALE OFFICE OFFICE BREAK ROOM\ OFFICE AREA = 2,900-S.F. 1-- - a a II„ A z z z Existing Oak, r a _ - V ° ° _ NEB - ° °� ° To Reirroin a CONCRETE PROPOSED ONE-STORY Existing Oak Tree oo j ;'K )III\\\ PHASE1 FILLED STEEL MANUFACTURI ,GBUILDING During the reviewyrocesswiththe Countyforthis M° a BOLLARDS (TYP.) II CANOPY MG MYR OFFICE AREA 2,900 S.F. project, rootprune the two oyyosite sides of the existing a I %G ° w " 2 990 MANUFACTURING AREA = 30,100 S.F. Oak tree andthen rootprune the remaining two sides a `i _ s I - 4 ° l �� stall He com feted of 1 unin i „ ILL six months later. This ro ° n a 1 a i PHASE 2 CANOPY/FUTURE ADDITION = 6,500 S.F. tr g a h/ d PROPOSED PE E witha inimum tame frame of three months for the R ° I ° a 41i� o X a FUTURE ADDITION — 28 20 TOTAL AREA = 39,500 S.F. secondyruningyrior to any construction activities on PAVEMENT' _ a 6,500 S.F. F.F.E. = 21.50 site. 'The tree shalrbe hdrricadect as shown in the tree G. - AR 91. 2. ✓AhCnon-native vegetation �., : n ° °. " A ° O ry J N D J barricade detailola sheet L- w moo ' LOADING t 23 andweeds shallhe removedfrom this area andthe tree ° g �^ ° + '9 a ozz ° nuCchedandpt4nted a itfi a row of native ferns around I\ U) o Z a ZONE �� the perbr eter of the tree island The ferns shalfhe a Q 11 allowed to grow so as to eventually fill the space and 41 ° ° h m ° inim ze the maintenance activity reauiredwith this _rpace. ° 12'z55' LOADING ! a / A Q ° ZONE ° a a4 1 9 Eroposed Buffer .9-Cedges & a a 4 3-Ledges sfiafl he maintainedat a minimum of 4s" in PROPOSED 2 e ° ., ° ° < x height on the east, west, andsoitth fan fscaye buffers " f, IIII// MANUFACTURING AREA g PAVEMENT ° a CONCRETE " i° 4 ° °' a 30,100 S.F. ^. a a ° ° ° a 4° , a °WHEEL STOPS — ° ° y �.4 ° ' m ° I ° r 01714 - PROPOSED PAVEMENT 1720 DUMPSTE D W/ 6' HIGH 1721 t. ;1 • MAS WALL & 100% OPAQUE ES W/ RECYCLE DUMPSTER 1716 ° hw i y _ x1Ji'- - j`Ju; J._..,- , a.. -ter•, r—'l �.� ��-� ter'-',.-. J '_ „'6 v:� ,- S�Vr�..� r., Jt' 1725 13 t r., 'tV'I. / �, 7��� �. /v. 10 LAND UFFER s 71 1 / AR/I'Iltli\ V �I�IIIIIV _ S _ /6IIv tir�r�- 1717 XlAll+l /I9'V�,I�_ rh 9i ��� t/II0h_ es 17187/5v\h / 02-25-1981 x X X X ORB 350 PG 111 X X x X X-- X X X 1 X TE PLAN X X X X X X APPROVED x X - X X January 27, 2021 - X — Approval Date PDS Order 2021-002 Approval Order ## Norte` CScale; l rr _ 2 J - - - - - -- — 0 10' 20' 40' 6onc(Pull l r a;PC 9 e�: } rJf Gray , Int p LanAscrtneArch%terlurc, - Sitr PlritatrinV 900 East Ocean Boulevard, Suite 130d Stuart, Florida 34994 (772) 344-2340 LC: 26000198 1 i 0 `F•.e 0 �N !V f�. VJ I County Project I Number. Jejjrey W. Smitb, RLA Florida Registration Number: LA 0001035. Job No. 19-1 103 Drawn By JWS Submittal Dates 2-20-2020 10-1-2020 1-5-2021 Revision Dates #1 County Comments 10-1-2020 #2 County Comments 1-5-2021 These drawings are the property of the landscape architect and are not to be used for other projects except by written permission from the landscape architect. Report any discrepancies immediately to the landscape architect. Pl L- 7 2 Sheet of landscape icat'tons n listed in "Grades and St andards for Tallahassee. All tonic of s d Florida, Dept. of A riculture a 1 and Part II State of Flo a P Nursery Plants" Part 9 u p 1 All tree and plant material to be Florida No. 1. or better, as classified in "Grades and St andards for W N Nursery Plants shall conform too Florida No. 1 as to: (1) health and vitality, (2) condition of foliage; (3) root system, (4) freedom from pest or mechanical damage, (5) heavily branched and densely foliated according to the accepted normal shape of the species: 2. Undersizing or substitution of one species or cultivar for another species is a breach of contract and will be "Rejected" at the time of final landscape inspection unless approved by Landscape Architect. 3. Project Warranty: All plant material shall be warranted for a period of one (1) year after date of substantial completion against defects, including death and unsatisfactory growth, except for defects resultingfrom abuse or damage by others or unusual phenomena or incidents which are beyond the contractor's control. 4. Any and all conditions which the contractor feels will be detrimental to the success of the planting shall be brought to the owner or representative's attention. 5, The contractor shall verify the location of underground utilities prior to commencing. work on any project area . Mulch planting areas y Eucalyptus, with layer of Melaleuca Eucal tus, or Enviromulch. Cypress Mulch is NOT ACCEPTABLE. Planting beds to receive mulch throughout entire bed area. 7. All plants to be set to ultimate grade. No filling will be permitted around trunks or stems. Mulch to be kept a minimum offrom trunks and stems. 8. away o u 'n detail. When plant is set, p lace additional backfill. consisting of a 50% mixture of Peat humus and natural soil around the base and sides of bali, and. work each layer to settle backfill 8. Planting trees and shrubs: Excavate hole per planting p p and eliminate voids and air pockets. When excavation is approximately 2/3 full water thoroughly before placing remainder of backfill. Water again after placing final layer of backfill and before installing mulch. pp Y. 9. with galvanized wire through flexible hose chafing guards, with wooden stake anchors immediately after planting. (See Detail) 10. Trees stake trees in 3 directions w g , 9 ' r that are slow Similar analysis such a s 16-0-8 4:0:2 can also be used. Fertilizers t e.. one labeled 12-0-8 . ( ) approximately 3:0:2 or 3:0:3 Y 10.7rees and shrubs shall be fertilized with a complete natural organic fertilizer with a ratio of copra y ( 9 ) release, controlled release, sulphur coated or with nitrogen as IBDU or ureaformaldehyde. have extended release period. Thirty to fifty percent of the nitrogen should be water insoluble or slow release. Palms should receive a complete granular fertilizer formulated for palms ("Palm Special") at a. rate of 5 to 8 lbs. per palm. - Agriform 20-0-5 twenty-one gram planting tablets may be substituted for granular fertilizer. If utilized, the following rates shall be utilized: Position plant in hole. Backfill halfway up the Football. Place tablet(s) beside rootball about 1" from root tips. Do not place tablets) in bottom of hole_ 1 Gallon I Tablet 3 Gallon 2 Tablets 25 Gallon & B&B Trees 2 per l" caliper 11. All planting areas to be irrigated to provide 100% coverage. Shop drawings to be submitted by the irrigation contractor for approval prior to installation. 12. Maintain trees, shrubs, and other plants by watering, cultivating, and weeding as required for healthy growth. Restore planting saucers and mulch. Tighten and repair stake and guying and reset trees and shrubs to proper grade or vertical position as required. Spray as necessary to keep trees and shrubs free of insects and disease. The contractor shall begin maintenance immediately after planting and shall continue maintenance through final acceptance when Certificate of Occupancy is issued to the General Contractor by County and project is released by the General Contractor to Client. 13. Prune trees and shrubs only to remove damaged branches as directed by the Landscape Architect. 14. Planting Lawns: Provide clean, strongly rooted, uniformly sized strips of Stenotaphrom secundatus Florham (unless otherwise noted),machine stripped not more than 24 hours prior to laying. Grade and roll prepared lawn surface. Water thoroughly but not to create muddy soil conditions. Lay sod strips with tight joints, roll or tamp lightly, and water thoroughly. 15.. Maintain positive drainage, no planting is to block drainage.. 16. Drainage Testing Prior to planting of trees, palms, and specimen material, each planting pit shall be tested in the following manner to verify adequate drainage: A) Fig planting pit to the minimum specified size. B) Fill thehe planting planting pit with (12").twelve inches of water. If the water level in the planting pit drops (4") four or more inches within (4) four hours, the drainage is sufficient and a drainage channel is not required. If the water level drops less than (4") four inches within the (4) four hour period, then a drainage channel is required. C) When a drainage channel is required, the drainage channel must extend down through the non porous soil and into porous soil. (See Drainage Testing Detail) D) Discard all material removed from the drainage channel. E) When backfilling the planting pit, add course gravel to the drainage channel. Also, care must be taken to keep the consistency of the soil mix the same throughout the planting pit. NOTES: 1. Contractor to include drainage testing for all trees and palms in bid. If drainage is inadequate, the. soil specification in item #8 above shall be revised for site conditions. Contractor shall notify. the Owner and Landscape Architect of poor drainage conditions in writing and written direction will be provided to the contractor of appropriate soil mixture specification to be used.. 2. All fertilizers shall meet the St. Lucie County fertilizer ordinance. landsca-m D Data 7.011 - Perimeter Landscaping Adjacent to Steel Boulevard Right -of --way 7.09.04. C.3 - Terminal & Interior Island Trees Total Length = 260' Trees Trees Required - 9 - .Required - (1 Tree/30Ill 1.f130 = 9 Trees Provided - 9 Provided -9 Trees 3 Existing Trees + 6 Proposed Trees 0 Existing Trees .+ 9 Proposed Trees = 9 7.09.01 - Required Tre€ Species Mix Shrubs Trees Required - Continuous Hedge 2'0. C. = 130 Shrubs Required - 41+ Trees = 5 Species Mix Provided - 130 Shrubs Provided - a Tree Species 7 09 04 A 1 Perimeter Landscaping Adjacent to Neighboring Properties - . 7.09.04.0 -Interior Vehicular Use Area Total Length = 1,460' Trees I. V. U,A. = 87,492 s.f Required - (1 Tree/301.f)-1,460 11./30 = 49 Trees 87,492 s.f. / 18 s.f. = 4,861 s.f. / 180 s.f. = 27 Trees Provided -49 Trees Trees 10 Existing Trees + 39 Proposed Trees = 49 Required - 27 - Provided - 27 - Shrubs ` 4 Existing + 23 P'r ojiosed Trees Required - Continuous Hedge 2' O.C. = 730 Shrubs Provided - 730 Shrubs Total Trees Required Trees Note: Required - 93 100% of proposed plantings are native. Provided - 8 Existing + 85 Planted = 93 7.09.03.E 21- Planting Under Utility Lines Note: Small tree - s are being g utilized to meet code section 7.09.03.E.2.1. No tree shall be planted where it could, at mature height, conflict with overhead power lines. Larger trees (trees with a mature height of thirty (30) feet ormore) shall be planted no closer than a horizontal distance of thirty (30) feet fromthe nearest overhead power line. Medium trees (trees with a mature height between with a mature height of line: Small trees trees et twenty (20)-thirty (30) feet) shall be off -set at least twenty (20) feet horizontally from the nearest overhead power( g less than twenty ( 20 shall not be required to meet a minimum off -set, except that no tree, regardless of size shall be planted within five (5) feet of any existing ) feet) or proposed utility pole, guy wire, pad mounted electrical transformer or other utility transmission/collection structure or equipment. Cant I is t QTY SYM SPECIES. COMMON NAME/DESCRIPTION SIZE SPACING REMARKS. DROUGHT TOLERANCE CANOPY IORNAMENTAL TREES .. 1 AR* ACER RUBRUM RED MAPLE 12' x 5', 2.5" DBH A.S. FULL CANOPY, 4' C.T. MIN. HIGH 20 IF ILEX x ATTENUATA'EAGLESTON EAGLESTON HOLLY 12' x 5', 2.5" DBH A.S. FULL CANOPY, 4' C.T. MIN. HIGH 2 MG' MAGNOLIA GRANDIFLORA D.D. BLANCHARD MAGNOLIA 12' x 5', 2.5" DBH A.S. FULL CANOPY, 4' C.T. MIN. HIGH SITE PLAN 23_ QL* QUERCUS LAURIFOLIA LAUREL OAK 12' x 5', 25' DBH A.S. FULL CANOPY, 4' C.T. MIN. HIGH . - 11 QV* QUERCUS VIRGINIANA - LIVE OAK 12' x 6, 2.5' DBH A.S. FULL CANOPY, 4' C.T. MIN. HIGH APPROVED 28 PE* PINUS ELUOTTI DENSA SOUTH FLORIDA SLASH PINE 12'x 5% 2.5" DBH A.S. FULL CANOPY, 4'C.T.MIN. HIGH LARGE SHRUBS IACCENTS MYR* MYRICANTHES FRAGRANS SIMPSON ST OPPER - #3,2'x2' 2'O.C. FULL&THICK HIGH Hillary 2,.7 2021 990 t MED,SHRUBS IGROUNDCOVERSIVINES 1SOD -- 100 NEB* NEPHROLEPIS EXALTATA BOSTON FERN - #1,1' x 1' 2' O.C. FULL &-NICK HIGH Approval SOD PASPALUM NOTATUM- BAHIA SOD SEE SPECS HIGH -FLORIDANATIVE 0 0 2 *-FLOR - 1). )1C�t'i" ��) e�aC�iC ne 1. No plant substitutions can be made without St. Lucie County s approval. 2. All required landscape improvements must be inspected and approved by St. Lucie County prior to the issuance of a Certificate of Occupancy. 3. Any existing landscaping,. sod, or irrigation damaged or destroyed during the construction shall be replaced prior to the final inspection. 4. All prohibited, exotic and invasive species shall be removed from the entire site prior to issuance of certificate of occupancy. 5. Planting adjacent to fire hydrants is to have a minimum clear radius of 7.5' as required by the NFPA Uniform Fire Code Florida Edition 18.3.4.1 Hydrants. All fire hydrants and fire check valves shall have a minimum of 7,5' from the front and sides with 4' from the rear to all landscape material per the Florida Fire Prev ntion Code. landscape Details plaut s, V � ) be PVPnf )) . .. to z x x1A w[<dHatten Sol ead s ared around murk o -tree. A m{ninnwn ";.; ,, . ,, • =d` of (5)five wraps of burlap are to be placed .,•+ r 4 : rubber hose oh all z" diameter black or I Place r/ Ar under the but to prevent marring t [rill ohr[s at contact with tree. -r,. / height s� l u wires a p f i the trunk. �Yhe het n � guy a � ."". damage G g f. . f1 � 1�. 'ee mulch f• - mfnin¢u.m. �fe iho-mulch ,Xeeym ".ro P. - o� 3 p f p. �7 battens .He uoca[ed un. rotation to the �� I� ��� height is f the f c 1 c. rteeCdouble strand - � � at rom base o stem (Sees ec%ications) V I Trace 3 laCvuntze f. ' r � ,;� .c � yf 1 .!) f height of YFie tree for adegluate bracing. No i f 1� gauge guy wires with. one afvanized o `� o batten is to be naflecC[o the tree. Battens I g 13 g J A - - ° ^ 1 rot %llrlClS!'!G/JC IY6'lbll(!l2%rP-SlIP/}l((1b71%lllJ V � �, a Planting depth shall equal o o J� n,'res aced ate ate l p q 1 - turnbuckle er u I t � g are to He Hizn<fed with a minhriurn o (2) tni,o }'. guy }e q - f � distance around tree above the first lateral _ -,s^� �' `.,l ©�� o � �. � HaCI: Diameter of hole to fie twice the size 3 4"sir h car6on steeC Hands. 1 l- `l ../ g - branch. Attach florescent safety fCags a. ma. `r..-�>d o � • f.3 of root ball for root balls larger than z' ern 900 East Ocean Boulevard, Suite 130d - - " in C n th to each a wire o o: dicuneter, the hole s(noukCtie z' wider than Stuart Florida 34994 M uumung o' (')three 4 x 4 wood braces of t2 t e g guy flu f 3 - © root button alfsides. Plaint to o root EaIC )' mutual pl 772 344-2340 ree to He toe ( ) around t evenC s ared 45" .. }r 45" ' 'shed rode. Trunk at same elev ation as grit Yree ?ru f H ". c LC: 26000198 i' .Attac(t (ore cent.ae I ge'ood [ attens 1 f Jf g , � - a min. of 12" in length to each wood brace. I ' -- Planting de tit sha(C be to% Cess-t(rwr the Finished °LTG i t ball rom the lair Root _ .1 7 height t the coo a. f f t •s f J1r e earth rim around arm., continuous a Diameter of here to be three times the size 'F I��II-tint- lantiag Mile: ..',.. - - 5 '.:- ,•::.: of root HnCCmuurmm�. -Cunt fop of root 6dlC II IIIII-_IIIII IIIII- I =1r p g at z" aIm min above the finished grade /� /" - =IIIII -' ITI elevation. - Guy 1Wire -Attachment DetalL ills Backiffil oundroot ball according to r.4r[lprdni,4g stint be comryletadat toe specifications. Water andtctmp to remove i. 9Jot to Scale'. direction 4 the fruviv Ai a e ., itect arrpoe'kets. Form a lids/i berm, with 3" mfninnurrt depth C m ` z. Re nmveanyaminnieerfiomaraundrootiia(( " and rrnore than 4 high. TfiuCcfi to edge of s. 9'tant as tierzftcron- with ol tor,. center) Place root Hall at bottomof urdsturbed v root6aQ but leave top of rootbaCC extrosed rp g pe - - pa subgrac(e ofp(antrngpi[. htr angu(xr racing as a m,it off, nrwgtb - Remove burlap or steeCeage tram top t/3 of root Ha(C(I a f p}disable). Shrub Detail z^ x 4" x 24" Long stake IIIIII IIIlrllllll e t 9y i .` 111 III: Fin .(ehedGrade 'Not to Sate II -111=ill lit -;I' I I''.I=III III 'II II-IIII III III I11-'I>F-P -Guy wire or woodHrucing it I_.rlll -III III III ,.:Iil; , ll III L-1 - Drive z x 4' x 24' woocfstake a min. 0 I 3' -III I'I I' III -III III III,_ 11ii- .. _ _.. below grade. - Tree Pit ' � g times diameter BackfiC( ¢rourtdroot Fialaccord rig to �� tatev and tam to rmno ve Root 23a(C ' ications 1 of raotbalr (Mint s} call p Setting / See 'Plant List for O.C. long center) spacutg :motes airpockets. O.C'. Spactug r ,Al(y,rwring shalttie cornp(eted at [hz : Plan View ?ree'Trunk d;rectfine o the Z"Id care-ri'mitott 3" minimum depth, of march. Xegr ttu.elch I �� away frmnz. No nai(,, sha(16, liven into tree r . Have of stem (Sec specifications) rom. �F� csraiCs. Stakin Detail �r.. Z4 r� rC>rt: Planting depth shaCCequal depth. of root gar e-ee PCantln D2talt (s"CwCiperJrCreater� F - �i ) �rJ Ha(C Diameter of hole to He twice the size ;Not to scare of root Gaff Plant top of root balrat same ,Nor to ScaleAm •' - elevation as finished grade:. '1=.II1!ill III _ III .I_II I' V ' it IIIIIII II I I !II-=11! I II -I' Finished Grade r .-III ITI III=111J - iJ spread Place t/z" diameter Hlack ru(ibw' hose on BackfiCf around root Huliuccorc{ing [o z times diante[er zz"efepth ojwater specifications. Water mgd tamp. to remove ENRON aft -guy wires at cullpoints efcontact smith. Drairw eTesting Pit of rooficia g g • ab _packets. tree. fhtis(tedgvacCe t bah - at bottom of undisturbed P hure alin O Pace 3galvanizecfsteeCdouble strand#t2 Volt porous soil - subgrade acylantingptt. rl gauge twitted guy wires with one 0 In garvanized t u rnbuck(e• per guy wire Porous soil • spaced at equaCciptance around tree. .. - - c .. r - h lx s a min. a `zz" .I -_ ---=I -' -` 6"cfiatneter drarrna e chartneC ..., Attachfl'ore centafe 11 F3 1 II ` 11=Ir'' g •.t_;, q .:;4� - in length to each a wire ' ;A °: n`0a: ,%, •.;,; %;v 3 rn in mum de [h o muldi.:Kee mulch g guy 'Kates °•; a,..`,:e.e..: �. .. Fr f Y xe er ro llcurtin.t detarB for size of r all l ' • away from base of stem (See specs/ications) "Eon .q Piant ttg depth. shall be to% less oulat the (tarn 1 it g - - Roothad .. height of the root halt trait the fluor Root. : T gp .•a; •• ".:• , ' 'ti�p.,g;•„+*•?•e;; Alternate spacing ofp(ants to insure o Diameter of hole to be three times the size ,finishedgr ode Y F Y� + a. •�- proper coverage ofgrotmdcovei of root HafLounimunt. Plant top of root a y%'' (?riangulateplairting) balrat z ntin&nurn above the f ncided o Planting mix �' .+••� 8 rude elevation. `,',.::,.';:.: r. .....t1p..�r. ,•�¢i' a. :.:;;. Ede o' Cwetin. bed Non prirous soil g IP g 9 S i� r'lh i1nnlimlm °"d''e'.y.. .•. .%r.;••.9 v arm a mulch berm w t 3 I Ig ¢; Ili v - Porous coal depth and no more flan 4" high. CMuLch to - - '- edge of rootbah, but leave top of rootball - fi donneter drainage chanieffilfecf ' exposed Ilr,.l III II-1il=III ski tCv>�ri„✓✓�'y' ) •�� a -- with course gravel: Discardmatei ild - TCantell yo Wife inadequate drainage removed from �'ahta e channel. U Remove burlap or stee(exage from top 1/3 f fl , II III=, ' a 4A1or: , 8 • . INi_ of root ball (If agraca6(e). ,. Drainage �estinp Detail Ground -Cover Detail Ills }aashecf Grade '.I (II=u =: - III_I Not to scare I I lI'' Not to scale 'I-=111 III 11. III=III i III 11= -- Drive z" x 4"x z4' wood stake a rnin of 3" =1 III Ir N befmv grade. tunes 6arneter - I -- Backf ful ound root ba(Caceording to -. ofrootbad(innrJ specifications. Water and -tamp to remove .Notes airpockets. r. Atlproung fiat "tie corugtctedal ill, fl d t tF with d,rectwn of the LandScaIe-Aulit" I. z wit scuts shall 6e driven into brew 2Jree Plantin Detail Not to scale spread Place t/2" diameter black rubber hose on aft -guy wires at adpomts of contact with . Q) tree. 0 Place 3 gaCvanized steef dou6Ce strcind#zz gauge twisted guy wires with one galvanized turn6uck(eperguy wire spaced at equaldistance around tree. Attach f(oreseent safety flags a mill. of tz" in Length to each guy wire. Planting depth shallbetoy Cess than. the , `vS height of the root baCG front the flair Root. D arneter ot-hole to be three times the size Of loot Halt ram mum Plant top ofroot - fort at 2" minimum above the finished grade elevation Ji form a mtdc(t Herrn with 3" nthlmnun{ `) depth and -no more than 4" high. aatCch to G edge of root6aQ but have top of raot6afl- - exposed Remove burlap or steel cage f rom top i/g a of root ball (if apphcabCe). - III . III=III= R f. I�III-III e e -�. • := III=!: r code i- l ' III IIII I I I 111 mil=11II ' I r III:.=III II' III III IIIIII IIIIII IIL�I_ I III=1' 'Drive 2" x 4" 4, f , xz woodstake a min. o g --III III III I I_I=-1 L. I! -,III-" below gi-ode [ernes diameter 3 _ BackftiCl ar'ouncfraot ball according to )rlr(lid(Min. r <r t ( ) J rsnove . s. Water undtant to e s eci icatfon. V p f NOIeS a it pockets r Al( run shaCtbe cans letedat the P n'U r dnr,c[fcrn of the Landscape firhftvcG 2 No nonfatal! be i cut alto tree .wlulti-,run.k Tree Planting Detail ,Not to scale Ti one & it a fran s age w degradable twine. There is to be a unless noted below . minimum of GB fr ands( ) (5) 2"x 4"x 18" waodbattens to be evenly tree to beprotected �peA"r, spaced aroundttuln ofpahn. Amulaulan : - "uG (�j 0 o (5)five wraps o bursa are to be laced Woodzn z x 4 g p 1 1 p f p p vertica(postsa G/ m� under the battens to prevent marring or : minimum of z' below U i( damage to the trunk. The Height of the - " rfI� grade andd3' above { Height shall He located fit relation. to the }i1� Fade. Space no more Height of (Fie }+ati n for adequate bracing. - t center. V No batten is to be naiCedto the alai. Pla:c as e < J' -lace ns s eci iedin p I - Battens are to be baincfedwith a ngbnirnum "Notes" Shown below.' of (2) two 3/4"high carbon steelbands. -Mmunum r (3) three 4" x 4 ° wood braces f Orange Safety }'erne- fff evenly spaced aroundpaCm to be toe -attach to vertical nailed to woodbatiens. AttaddlCorescent post leaving no slack sa et l s a influ nunt of 12" in. Cen tli to } y1 tf3 !3 in fence. each brace z .� d Undisturbed Area 2 Planting depth shad6e to% less than the ve ' (eight of the root Half. Diameter of hole to -x Existing Grade be time times the size of root Call minunum- +o Pliant top of root banal 2" minimum above } -, the finished grade elevation. Fruit it match berm with 3" minimum, depth and no nmre than 4° high, -'"turn to � edge of I ootharC but (wave top of rootball- pi exposed Bacilici notmdroot 6al(according to c specifications. Waterandtamp to remove airpockets. The criticalroot zone (CRL) is 5n area around a lee that is regulated by St Lucie CountyLent{ Development Rcgulalions future purpose of protecting the routs pnd mink into protected tree or a specimen tree, both during and after Constructiunat is a ciradar finished Grade area using a radius measured from the centurof the tree. The radius is calculated as one(]) fouPofradius concern lint I inch of _Ili- 111. _'11 .. diameter it breast height 4.5 feet ab rvc grade). For an function of a foot over a whole foot lute diameter at breast height will be ' A•�r - .. Pr .. .,�i,.. ,.'-- n it n '. �i - I - n and one- muicr 211/4 mvn c u t the nest whole r diameter i t at react height of "wen li e >.)tir dd u ) Example; use dra nee b stake to be z Celt umber. F,xam h ) -�z x xz wood sta g ty 9 J _ P.. P --Ili- ,t v hven -two 22 feet. - ' I = - inches; the 'RZ is a circle ten r f [he tree with a radius of I I III S C toed on the swage o ) _r grade, h' II III III II II I cl e� [r tall from the center of the tree a[Ils bast unles's - - hr no event s'Itall the CRZ b less than an area measured five 5 fee ad I III -d III III L. III - O Y .I I III_ -III III III -II I I I sirllished Atrec well )shall be �.- - Size of rootball gvihbe btproporL'Cort to [t)pe expresslyddermind by the cnviromnentdplanner that srirailter spec lfied CRZ mrybee .l bn vthevia ilil ofa rmccal free ors ecunen tree robe rer erred us appropriate in case.: when the placement of fill Threatens b Notes andsize ofpahn, in accordance gm{th. 1py. P p I. sfiu r¢wnrt ie .ala(Palins ar a u pa f(orrda Grades and5tandards for Nursery resCrved. z. AC(Yva,hm tonic ant Saba( Palm to be looted' [ its n I COfISII'ImIC such as Cx15Iln Oi lrOlOSed C11r65 g hi ca fain cases, the bmncadc shall be mstallcd as shown. un the Ilia t, due o 4 ' titian. 1 g proposal wdess other verse rurtedm twit Cist. Plums Pant L& II fattest E nenvironmental llanncr al the sidm ak: lavcvlenl dil<hc, sw,I emu and shell be onto lrzrvcdb dtc vl s ces bCounty. vi[li Turned r axon redh'nnks wrlLnn[ le I P4 YI i. PuGllsr o _ "I hied. Palm Planting Detail Existing iree Protection Barricade Detail Not to scale :Not to scare Ill Allill C/) County Prole Number: Jeffrey W. Smith RL.A - ere y , Florida Registration. Number: LA 00016- 35 Job ' No. 19-1103 brawn By JWS Submittal Dates 2-20-2020 10-1-2020 1-5-2021 Revision Dates #1 County Comments 10-1-2020 #2 County Comments 1-5-2021 .These drawings are the property of the landscape architect and are not to be used for other projects except by written permission from the landscape architect. Report any discrepancies immediately to the landscape architect. L-2 2 Sheet of '