HomeMy WebLinkAboutAPPROVED, GAF R-22 UNDERLAYMENTBCIS Home Log In User Registration Hot To
dbpr 40,
Product Approval
USER: Public User
Product Approval Menu > Product cr Application SearC
FL *
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
"technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration D
Validated By
Certificate of Independence
Referenced Standard and Year (of Sta
is Submit Surcharge Stats & Facts Publications ContaLL Us aCIS Site Map Links Search
� 6R,21!f, inn Llst > Application Detail
FL10626-R22
Revision
2020
Approved
GAF
1 Campus Drive
Parisppany, NJ 07054
(800) 766-3411
mstieh@gaf.com
Robert Nleminen
Ireith�Dnemoetc,com
William Broussard
1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
Tech nicalQuestlonsGAF(Tgaf.cam
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
ped the Robert Nieminen
PE-59166
UL LLC
12/31/2024
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL10626 R22 COI 2021 01 COT NIEMINEN.pdf
Standard
Year
ASTM D1970
2015
ASTM D4533 (tear)
2015
ASTM D4798 (weathering)
2011
ASTM D4869 (water transmission)
2016
ASTM D5035 (tensile)
2011
ASTM D6164
2011
ASTM 06757
2016
FM 4474
2011
FRSA/TRI, 6th Edition
2018
Equivalence of Product Standards
Certified By
Sections from the Cade
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
_Summary of Products
FL # Model, Number
10626.1 GAF Roof Underli
use in FBC non-h
jurisdictions
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Ye!
Impact Resistant: N/A
Design Pressure: +N/A/-442.5
Other: 1.) The design pressure noted i
application relates to one particular
underlayment system. Refer to ER Sect
for details. 2.) Refer to ER Section 5 for
limits of Use.
The state of notice is an AA/EEO employ[
under Florida law, email addresses are public ".
mail to this entity. instead, contact the office by pt
Ford. Statutes, a%active October 1, 2017, Ilren"
provided may be used for official cdmmunicaton
provide the Department with an email address with
Method 1 Option D
06/09/2021
06/11/2021
06/17/2021
09/10/2021
12/16/2021
lame Description
ants for Roofing Underlayments for use in sloped roof systems
Installation Instructions
FLIn626 R22 11 2021 06 09 FINAL ER GAF UNDERLAYMENTS FL10626-
R22.odf
Verified By: Robert Niemien 59166
Created by Independent Third party: Yes
this Evaluation Reports
Fl 1'1 R99 AF 2021 1716 09 FINAL ER GAF UNDERLAYMENTS FL10626z
t 5.B.3 RRt2.pif
ther Created by Independent Third Party: Yes
.:: 2601 Blair Stone Road Tallahassee FL 32399 Phone 850-487-1824
igyriohl2007-2013 Slate of Flnntla.:: Privacy Statement :: Accessibility Statement :: Refund Statement
s. If you do not want your e-mail address released in response to a public -records request, do not send electronic
a nr by traditional mall. If you have any questions, please contact SSOA97.1395. •Punuent to Section 455.275(3),
licensed under Chapter 455. F.S. must provide the Department with an email address If they have one. The smalls
I the licensee. However emall addresses are public record. If you do not wish to supply a personal address, please
lan be mad. avallable t9 the public To determine Ir you are a licensee under Chapter 455, ES., please click here
Product AFprcval Accepts:
®®oar«
SCCUTliVMFTRICB'
23
NEMO I etc.
Certificate of Authorization #31455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALU TE TEST CONSULT
EVALUATION•'
GAF Evaluation Report 01506.04.08-R22
1Campus Drive FL10626-R22
Parsippany, NJ 07054 Date of Issuance: 04/25/2008
(800)766-3411 Revision 22:06/09/2021
SCOPE:
This Evaluation Report is issued under Rule SG20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida B ilding Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for co Ipliance with the 71 Edition (2020) Florida Building Code sections noted
herein.
DEscituanON: GAF Roof Underlayments for usi in FBC non-HVHZ Jurisdictions
LABELING: Labeling shall be in accordance wi the requirements of the Accredited quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility locat6n(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by th named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assu nce or the production facility location(s). NEMO ETC, LLC requires a
complete review of Its Evaluation Report relat ve to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOI etc. Evaluated" may be
displayed in advertising literature. If any po tion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this
its distributors and shall be available for
This Evaluation Report consists of pages 1
Prepared by:
RobertJ.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it ini
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or con
3. Robert Nieminen, P.E. does not have nor will
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will
product.
5. This is a building code evaluation. Neither NE
project on which this Evaluation Report, or pi
specifically for that purpose.
Evaluation Report shall be provided to the user by the manufacturer or
Lion at thejob site atthe request of the Building Official.
91
for?q,� •,.- _
�.i�'J't r; •
.'s
•_�;. ao-ea,ai si. c
The facsimile seal appearing was authorized by Hobert
Nleminen,P.E.on 06/09/2021. This does not serve as an
electronicallysigned document.
to acquire or will it acquire, a financial interest in any company manufacturing or
!d by any company manufacturing or distributing products it evaluates.
ire, a financial interest in any company manufacturing or distributing products for
Are, a financial interest in any other entity involved in the approval process of the
ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
us versions thereof, is/was used for permitting or design guidance unless retained
D2019 NEW ETC, LLC
ONEMOI etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing '
Sub -Category: Underlayn ent
Compliance Statement: GAF Roof Und dayments, as produced by GAF, have demonstrated compliance with the
following sections of the 7r'' Edition (20 ) Florida Building Cade through testing in accordance with the following
Standards. Compliance is subject to th Installation Requirements and Limitations / Conditions of Use set forth
herein.
Section
1504.3.1
1507.1.1, 1507.2.4, 1507.2.9.2 /
R905.1.1, R905.2.8.2
1507.1.1.1(2&3, Exception),
1507.1.1.1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
1507.1.1.1(2&3, Exception),
1507.1.1.1(S) / R905A.1.1(28,3,
Exception), R905.1.1.1(5)
1507.1.1.1(5) / R905.1.1.1(5)
1507.1.1 / R905.1.1
1507.3.3, R905.3.3
1507.11.2
TAS 110
E�-t t
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST6049)
Intertek (TST 1558)
NEMO (TST 6049)
NEMO (TST6049)
NEMO (TST 6049)
NEMO (TST6049)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (T5T 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST5878)
PRI (TST5878)
NEMO ETC, LLC
Certificate of Authorization #32455
Pro a
Standard
Year
Wind res
stance
FM 4474
2011
Material
tandard
ASTM D1970
2015
Tear Stre
igth
ASTM D4533
2015
Tensile sl
rength
ASTM D5035
2011
Liquid w
ter transmission
ASTM D4869
2016
Material
itandard
ASTM D6757
2016
Material
tandard
FRSA/TRI,Sixth Edition
2018
Material
itanclard
ASTM D6164
2011
Accelera
ed Weathering
ASTM D4798
2011
ASTM D
ASTM D
ASTM D
ASTM D
ASTM D
ASTM D
ASTM D
ASTM D
Physical
ASTM D
ASTM D
ASTM D
ASTM D
ASTM D
ASTM D
Wind UI
Wind UI
Wind UI
ASTM D
ASTM D
ASTM D
ASTM D
ASTM D
ASTM D
ASTM D
ASTM D
7TM
& FRSA/TRI (Slippage)
(GA)
(GA)
(GA)
(GA)
(GA)
(IN)
(Dadra, India)
erties (ON)
TAS 103
I (IN)
(OK)
3 (NC)
(various)
(AL)
(LA)
(Dadra, India)
(Dadra, India)
D5035(VA)
(Umerkui Kilvani, India)
(Parzai, India)
Reference
G34150.08.11
G40630.01.14-2B
G46160.09A4-3A
GAF-SC13285.03.17-3
GAF-SC13285.03.17-4
GAF-SC13285.03.17-1
GAF-SC16440.12.17
F8549.02-106-18
4q-GAF-19-55M138-03.A
4j-FTS-20-SSU DL-01.A
4j-GAF-20-SSU D L-02.A
4j-FTS-2I-SS U D L-02. A
GAF-324-02-01
GAF-339-02-01
GAF-349-02-01
GAF-434-02-01
GAF-434-02-03
GAF-434-02-04
GAF-818-02-01
MSA-047-02-01
GAF-826-02-01
GAF-847-02-01
GAF-914-02-01
376T0012
376T0018
376T0019
(2020) FBC NON-NVRZ EVALUATION
GAF Roof Underlayments
Date
11/14/2011
01/07/2014
09/09/2014
03/01/2017
03/01/2017
03/08/2017
12/31/2017
11/08/2016
05/13/2019
12/01/2020
03/15/2021
06/09/2021
11/30/2011
03/13/2012
07/03/2012
09/16/2013
09/16/2013
09/16/2013
12/05/2017
04/11/2018
06/4/2018
06/4/2018
04/10/2019
07/15/2019
07/31/2019
07/31/2019
Evaluation Report 01506.04.08-RZ2
F110626-1122
Revision 22: 06/09/2021
Page 2 of 9
M
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
NEMO ETt
Certificate c
NNEMO I etc.
Entitv Examin
tion Reference
Date
PRI (TST 5878) ASTM D
70(AR) 376T0032
10/22/2019
PRI (TST 5878) ASTM D
6(S-CA) 376TOO54
02/18/2020
PRI (TST 5878) ASTM D
33 (Gujarat, India) 376TOO58
02/18/2020
PRI (TST 5878) ASTM D
35(various) 376TO103
09/11/2020
PRI (TST 5878) ASTM D
33, D5035 (Rajasthan, India) 376TO111
12/22/2020
PRI (TST 5878) ASTM
33, D5035 (Gujarat, India) 376TO113
12/22/2020
UL(TST 1740) ASTM D
757(TX) 02NK22569
06/04/2002
PRI (TST 5878) ASTM D
35 (Gujarat, India) 376TO146
03/11/2021
PRI (TST 5878) ASTM
33, D5035 (Rajasthan, India) 376TO161
05/07/2021
UL(TST 1740) ASTM D(
757 INC) 1ONK11990
05/18/2011
NEMO ETC Traceabi
ty FBC Cross -Listing
04/22/2020
NEMO Traceabi
ty FBC Cross -Listing
04/09/2021
UL, LLC (QUA 9625). Quality
ntrol Service Confirmation
03/23/2021
ILL, LLC (QUA 9625) Quality
C antrol Service Confirmation
(AL) 05/04/2020
UL, LLC (QUA 9625) Quality
ntrol Florida BCIS
Current
PRoDucT DESCRIPTION:
Product
Material Standard
Plant(s)
GAF Extended Dry -In Membrane
ASTM D1970
Langley, BC Canada
Liberty'" SBS Self -Adhering Base/Ply
ASTM D1970
Mt. Vernon, IN
Sheet
Savannah, GA
Mt. Vernon,
StormGuard• Film-Surfaced:Leak-Barrier
ASTM D1970
Savannah, GA
Arkadelphia, AR
WeatherWatch° Mineral -Surfaced Leak
ASTM D1970
Mt. Vernon, IN
Barrier
Savannah, GA
Tuscaloosa, AL
Deck -Armor"' Premium Breathable Roof
1507.1.1.1(2&3, Exception) /
Dadra, India
Deck Protection
R90S.1.1.1(2&3, Exception)
Dadra, India
FeltBuster'"' Synthetic Roofing Felt
1507.1.1.1(2&3, Exception),Gujarat,
India
(CPP) Rajasthan, India
(formerly FeltRuster"'High-Traction Synthetic
1507.1.1.1(5)/ R905.1.1.1(2&3,
(MIP) Ra)asthan, India
Roofing Felt)
Exception), R905.1.1.1(5)
Richmond, VA
Spartanburg, SC
Shingle -Mate° Roof Deck Protection
ASTM D226, Type II (Table 1)
Pryor,
Shaffer,, CC A
StormSafe'" Anchor Sheet
1507.1.1.1(2&3, Exception) /
North Bay, ON
R905.1.1.1(2&3, Exception)
Dadra, India
Tiger Paw'" Premium Roof Deck
1507.1.1.1(2&3, Exception) /
Gujarat, India
Protection (formerly Tiger Pow -Roof Deck
R905.1.1.1(2&3, Exception)
Parzai, India
Protection]
Umerkui Kilvani, India
VersaShield° Fire -Resistant Roof Deck
ASTM D6757
Conover, NC
Protection
Ruberoid° Mop Granule
ASTM D6164
Savannah, GA
FRSA/TRI 09-18
Ruberoid° Mop Granule FR
ASTM D6164
Savannah, GA
FRSA/TRI 09-18
LLC
Evaluation Report 01506.04.08-1122
f Avthu,kutlon p32455 7-EDITI
N (202D) FBC NON-HVHZ EVALUATION
FL10626-1122
UN, Roof lJode d,
Page 3 of 9
5.1 This is a building code evaluation. Neitt
of Record for any project on which this I
or design guidance unless retained spec
5.2 This Evaluation Report is not for use in
Dade Counties).
5.3 This Evaluation Report pertains to abo%
accordance with FBC requirements to tl
ONEMOletc.
NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
iluation Report, or previous versions thereof, is/was used for permitting
cally for that purpose.
3C High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
deck roof components. Roof decks and structural members shall be in
satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fi e classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insul tion.
5.5 GAF Roof Underlayments maybe used ith any prepared roof cover where the product is specifically referenced
within FBC approval documents. If nol listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation com ned with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
LE 1: ROOF COVER OPTIONS
FBC Section.
1507.2
1507.3
1507.4 and IS07.5
1507.7
1507.8 and IS07.9
as
and Concrete Tile
Metal
Slate or
Wood
Asphalt
Mech
nical
Adhesive-
UnderlaymeM
Slate -Type
Shingles
Panels
Shingles
Shingles
Shingles
Shakes
A
ch
Set
Yes
Yes
GAF Extended Dry -In Membrane
Yes
N
No
Yes
Yes
Yes
0.11, strips,
flGIM6MPs,
u07.1.13/
ss07.1.131
R905.13.3)
R90511.31
Yes
Yes
Liberty— SRS Self -Adhering
Yes
IN
No
No
No
No
UolM1.1.3/
G9iM:ono..
Base/Ply Sheet
1505.113/
89DS. 13/
R905.3.1.3)
R905.1.1.3
Yes
Yes
StormGuard' Film -Surfaced Leak
Yes
No
Yes
Yes
Yes
(iamunips,
lj M"" .
Barrier
1507.1.13/
15071.13/
N905.11.3)
ft%5.1.1.31
Yes
Yes
WeatherWatch®Mineral-Surfaced
Yes
No
No
No
No
Leak Barrier
15071.13/
19a,5_13/
15071.13/
R9U5.1.1.3)
R051.1.3/
R9U5.1.1.3)
Deck -Armor"' Premium Breathable
Yes
No
Yes
Yes
Yes
No
No
Roof Deck Protection
FeltBuster- Synthetic Roaflng Felt
Yes
I,
No
No
No
No
No
No
Shingle -Mate° Roof Deck
Yes
No
No
No
No
No
No
Protection
Tiger Paw- Premium Roof Deck
Yes
No
Yes
Yes
Yes
No
No
Protection
VersaShield° Fire -Resistant Roof
Yes
No
No
No
No
No
No
Deck Protection
Yes
Y
s
Ruberoids MOP Granule
No
(cap 5
tee in
(Cap Sheet in
No
No
No
No
No
2-ply,
stem)
2-ply system)
See 5.6.1
Yes
Ruberoid 2 Mop Granu le FR
No
ICaa
5
eet,,
No
No
No
No
No
2-ply
Z-plsheetin
system)
See 5.6.1
See
NEMO ETC, LLC
Certificate ofAuthonzation N32455
7- EDITI N (20201 FBC NON-HVHZ EVALUATION
GAF Roof Underlayments
Evaluation Report 01506.04.08-R22
FL10626-R22
Revision 22; 06/09/2021
Page 4 of 9
NNEMO I etc.
5.6.1 Adhesive -set is limited to use of fo I I owl1rig underlayment /tile -adhesive combinations.
TABLE1A:ALLOWAB
UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS'
Underlayment
Adhesive
Florida Product Approval
Ruberoid® Mop Granule; Ruberoid- Mop Granule FR
Dupont "Tile BondTM Roof Tile Adhesive"
FL22525
5.7
5.8
5.8.1
Allowable Substrates:
TABLE 2: 5
BSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Primer
Substrates
GAF Extended Dry -In Membrane
self -adhering
None
plywood
Liberty"' SBS Self -Adhering Base/Ply Sheet
self -adhering
(Optional)
ASTM D41
plywood
StormGuard• Fllm-Surfaced Leak Barrier
Weather Watch® Mineral -Surfaced Leak Bar
ier
LibertyTM SBS Self -Adhering Base/Ply Sheet
self -adhering
None
ASTM D226 felt, Type II
StormGuard• Film -Surfaced Leak Barrier
Weather Watch$ Mineral -Surfaced Leak Bar
ier
Liberty" SBS Self -Adhering Base/Ply Sheet
self -adhering
ASTM D41
metal (flashing metal, valley metal,
etc.)
StormGuard• Film -Surfaced Leak Barrier
Weather Watch' Mineral -Surfaced Leak Bar
o
ter
Ruberoid® Mop Granule
hot asphalt
ASTM D41
structural concrete
Ruberold° Mop Granule FR
Ruberoid® Mop Granule
Ruberoid® Mop Granule FR
hot asphalt
None
GAFGLAS• #80 Ultima'" Base Sheet
or Ruberoid® 20 Smooth
Attachment Limitations:
For use under mechanically attached ON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instru ions, but —for mechanically attached underlayments or base sheets -not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, a'
instructions, but —for mechanically a
• FRSA/TRI Florida High Wind Co
Table 1(for Two -Ply Asphalt Apl
or
• Section 5.8.3 herein (for other u
5.8.3 Wind Resistance for Underlayment S�
The following wind uplift limitations
Florida High Wind Concrete and Clay
is the result of testing for wind load I
pressure divided by 2 (the 2 to 1 mar
5.8.3.1 Direct -to -Deck:
The maximum design pressure for t
Florida High Wind Concrete and Cla)
critical (highest) design pressure dett
t Refer to Tile Manufacturers or Adhesive
NEMO ETC, LLC
cerbjicme ofAuthoruation #32455
chment shall be in accordance with the manufacturer's installation
ched base sheets - not less than:
ete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
d Hot Mop Underlayment)
systems).
fly to underlayment systems that are not prescriptive in the FRSA/TRI
(Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
tance based on allowable wind loads, and reflects the ultimate passing
of safety per FBC 1504.9 has already been applied).
selected assembly shall meet or exceed that required under FRSA/TRI
oof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
tined in accordance with FBC 1609 or FBC Residential Chapter 3.
Manufat urers Florida Product Approval for Overturning Moment Resistance Performance,
Evaluation Report01506.04.08-RZ2
7- EDITI (2020) FBC NON-HVHZ EVALUATION FL10626.R22
GAF Roof Underlayments Revision 22: 06/09/2021
Page 5 of 9
#1 Maximum Design Pressure=-442.5 pi if.
ONEMO I etc.
Deck: Min. 2,500 psi structural oncrete to meet project requirements to satisfaction of Authority Having
Jurisdiction
Base Sheet: GAFGLAS #75 Base SheeirTri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4,
Tri-Ply Ply 4 or GAFGLAS lex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20
to 25lbs/square.
Cap Sheet: Ruberoid® Mop Granuler Ruberoidv Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 2 Ibs/square.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for th' selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay ooJTile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordi nce with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density d signed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods dre ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Asse blies marked with an asterisk' carry the limitations set forth in Section
2.2.10.1 of FM Loss Prevention Data 5 eet 1-29 (February 2020) for enhancements.
#2 Maximum Design Pressure = -45 osf.
Deck:
Min. 19/32-inch plywo9d
to meet project requirements to satisfaction of Authority Having
jurisdiction.
Base Sheet:
GAFGLAS® #80 UltimaT" 13ase
Sheet or RuberoiO 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring I
hank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c.
at the min. 4-inch wide
de laps and 9-inch o.c, at two (2), equally spaced, staggered center rows
in the field of the sheet.
Cap Sheet:
Ruberoid° Mop Granule
r Ruberoid® Mop Granule FR applied in full mapping of ASTM D312, Type
IV hot asphalt at 20 to 21
Ibs/square.
#3 Maximum Design Pressure=-75 osf.
Deck:
Min. 19/32-Inch plywo
d to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
GAFGLASO #80 UltiMaTM
Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring
ank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c.
at the min. 4-inch wide s
de laps and 8-inch o.c. at three (3), equally spaced, staggered center rows
in the field of the sheet.
Cap Sheet:
Ruberoid® Mop Granule
r Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 2
Ibs/square.
#4 Maximum Design Pressure = -97.5 ps
Deck: Min. 19/32-inch plywo d to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima'" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga.,
min. 1.25-inch long ring hank nails through 32 ga., 1-5/8-inch diametertin caps spaced 4-inch o.c.
at the min. 2-inch wide s de laps and 4-inch o.c. at four (4), equally spaced center rows in the field
of the sheet.
Cap Sheet: Ruberoid® Mop Granule pr Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 21 Ibs/square.
NEMO ETC, LLC Evaluation Report 01506.04.08-R22
Certifit'ate o)Authorizatlon#32455 7n'EDIT] (2020)FFIC NON-HVH2 EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22: 06/09/2021
Page 6 of 9
ONEMO I etc.
5-9 Exposure Limitations:
T
LE 3: ExPosuRE LimrrA
nONs
Prepared Roof [over
Maximum
Underlayment
!
Installation Type
Exposure
(days)
Deck -Armor'" Premium Breathable Roof Deck Protec
ion, FeltBusterT" Synthel
is
Roofing Felt, Shingle -Mate" Roof Deck Protection, St'
rm5afe'" Anchor Sheet,
Tiger
Paw'" Premium Roof Deck Protection, VersaShield" F
re -Resistant Roof Deck
Mechanically attached
30
Protection, Liberty' SBS Self -Adhering Base/Ply She
, StormGuard" Film -Sur
aced
Leak Barrier and WeatherWatch" Mineral -Surfaced
ak Barrier
GAF Extended Dry -In Membrane
Mechanically attached
180
Adhesive -set tile roof system
180
Ruberoid" Mop Granule and Ruberoid® Mop GranUl9
FR
Mechanically attached
UNLIMITED
5.10 Tile Slippage Limitations: When loadi g roof tiles on the u derlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as folio s. These slope limits ions can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SuPP
LIMITATIONS FOR DIRE
-DECK TILE INSTALLATIONS
Underlayment
Tile Pr
file
Staging Method
Maximum Staging Slope
Ruberoid" Mop Granule
Fla
Vlax. 10-tile stack
4:12
Fla
Max.
6-tile stack (4 over 2)
5:12
Lugg
d
Vlax. 10-tile stack
5:12
Ruberoid" Mop Granule FR
Flat or L
gged
Max
6-tile stack (4 over 2)
5:12
Lugg
d
Vlax. 10-tile stack
4:12
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to
the Limitations set forth in Section 5 hi
ein and the specifics
oted below.
6.2 Re -fasten any loose decking panels, a
d check for protrudiflig
nail heads. Sweep the substrate thoroughly to
remove any dust and debris priorto a
lication and prime th
substrate (if applicable).
6.3 Deck -Armor- Premium Breathable Re
of Deck Protection or
iger Paw- Premium Roof Deck Protection:
6.3.1 Shall be installed in compliance with r
uirements for a synthetic
underlayment in FBC 1507.1.1.1(2, Exception)
or 1507.1.1.1(3, Exception) or FBC Res
dential R905.1.1.1(2,Exception)
or R905.1.1.1(3, Exception) for the type
of prepared roof covering to be installe
I, and the manufacturer's
installation instructions. FBC requirements take
precedence over the manufacturer's ir
stallation instructions.
6.4 Fe@BusterTM Synthetic Roofing Felt:
6.4.1 Shall be installed in compliance with rE
qUirements for a synt
etic underlayment in FBC 1507.1.1.1(2, Exception),
1507.1.1.1(3, Exception) or 1507.2.1.
5) or FBC Residential
R905.1.1.1(2, Exception), R905.1.1.1(3, Exception)
or R905.1.1.1(5) for the type of prepared
roof covering tc
be installed, and the manufacturer's installation
instructions. FBC requirements take p
ecedence over the manufacturer's
installation instructions.
NEMO ETC, LLC
Evaluation Report 01506.04.08-R22
Certiifimte of Authomation#32455 741 EDITI
N(2020)F8C NON-HVH2 OALUATION
FL10626-R22
GAF Roof UnderlaymenO
Revision 22: 06/09/2021
Page 7 of 9
ONEMOletc.
6.5
StormSafe'" Anchor Sheet:
6.5.1 StormSafeT" Anchor Sheet is limited to
ise as a mechanically
ttached base layer in 2-ply underlayment systems.
6.5.2 Shall be installed in compliance with requirements
for a syntf
etic underlayment in FBC 1507.1.1.1(2, Exception)
or 1507.1.1.1(3, Exception) or FBC Residential
R905.1.1.1(2,
xception) or R905.1.1.1(3, Exception) for the type
of prepared roof covering to be installeil,
and the manufacturer's
installation instructions. FBC requirements take
precedence over the manufacturer's in
tallation instructions,
6.5.3 One the same day, install Liberty'"' S
S Self -Adhering Bas
/Ply; StormGuard9 Film -Surfaced Leak Barrier or
WeatherWatch® Mineral -Surfaced Leal
Barrier overthe Star
Safe' Anchorsheet.
6.6 Shingle -Mate® Roof Deck Protection:
6.6.1 Shall be installed in compliance with requirements
for an approved
mechanically attached underlayment (ASTM
D226, Type II) in FBC Table 1507.1.1.1 c
r FBC Residential Table
R905.1.1.1 for the type of prepared roof covering
to be installed, and the manufacturer
installation instructs
ns. FBC requirements take precedence over the
manufacturer's installation instructions.
6.7 VersaShieldO Fire -Resistant Roof Deck
Protection:
6.7.1 Shall be installed in compliance with requirements
for an app
roved mechanically attached underlayment (ASTM
D6757) in FBC Table 1507.1.1.1 or FBC
lesidential Table R90
.1.1.1 for the type of prepared roof covering to be
installed, and the manufacturer's in
tallation instructions
FBC requirements take precedence over the
manufacturer's installation instructions.
6.8 GAF Extended Dry -in Membrane, Libe
'" SBS Self-Adherin
Base/Ply Sheet, StormGuarde Film -Surfaced Leak
Barrier or WeatherWatch° Mineral -Sy
faced Leak Barrier:
6.8.1 Shall be installed in compliance with rei
I uirements for an app
oved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Rc
side ntial R905.1.1.1 a
r R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's
installation instructions.
6.8.2 Back -nailing is required. Back -nailing si
all consist of Approve
A cap nails spaced 18-Inch o.c., encapsulated within
min. 4-inch side laps.
6.9.3 When installed over a mechanically att
ched, FBC Approved
ASTIM D226 Type II felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905
1.1.
6.8.4 GAF Extended Dry -In Membrane, Libe
'" SBS Self-AdheringBase/Ply
Sheet, StormGuard® Film -Surfaced Leak
Barrier or WeatherWatch® Mineral-S
rfaced Leak Barrier may
be installed as a secondary water barrier using
minimum 4-inch wide rolls to seal ply
od deck joints prior to
installation of the primary underlayment system.
6.9 Ruberold• Mop Granule; Ruberoid• lY
op Granule FR:
6.9.1 Shall be installed in compliance with rE
uirements as an altei
nate to the "Hot Asphalt Applied Cap Sheet" in the
"Two Ply System" in the FRSA/TRI F
3rida High Wind Concrete
and Clay Roof Tile Installation Manual, Sixth
Edition, and the manufacturer's install
tior instructions.
6.9.2 Refer to Section 5.8 herein for attach
nt limitations.
6.9.3 Refer to Table 4 for tile staging limitati
ns.
EMO ETC, LLC
Evaluation Report 01506.04.08-R22
,rtfmre ofAorhorhotmn N32455 V� EOITI
(2020) FBC NON-HVH2 E
ALUATION FL1062rrR22
GAF Roof Underlayments
Revision 22: 06/09/2021
Page 8 of 9
ONEMOjetc.
As required by the Building Official or �uthority Having Juris{liction to properly evaluate the installation of this
product.
Contact the named CIA entity for manuticturingfacilities cove{ed by F.A.C. Rule 61G20-3 CIA requirements. Refer
to Section 4 herein for products and pr duction locations having met codified material standards.
UL, LLC. — QUA9625; (414) 248-6409; k ren.buchmann@ul.c
D OF EVALUATION
NEMO ETC, LLC
Certificate of Author¢otion#32455 71O
Evaluation Report 01506.00.09-RZ2
1 (2020) FBC NON-HVHZ EV LUATION FL10626-R22
GAF Roof Underlayments Revision 22: 06/09/2021