HomeMy WebLinkAboutConstruction PlanPLUMBING SYMBOLS SYMBOLS COLD WATER (CW) HOT WATER (HW) SEWER (S) - - - - VENT LINE (V) �y y-� PLUMBING I^IX URE SCHEDULE' --- RECIR. HOT WATER CODE DESCRIPTION HW CW WASTE VENT TRAP REMARKS HAND SINK, WALL MOUNT, WITH FAUCET. PROVIDE ASSE 107Q CD CONDENSATE DRAIN SELECTED BY OWNER AND INSTALLED: BY APPROVED BELOW DECK HS-T CONTRACTOR. 1/2" 1/2" 22" 1 1/4" 1 114" MECHANICAL MDQNG / X EXISTING PIPE TEMPER)NGVALVE. SET AT 8 CONNECT TO EXISTING MAX 110 DEG FOR HW, 3 COMPARTMENT SINK, FLOOR MOUNTED, -SD- STORM DRAIN (SD) S-1 FAUCET SELECTED BY OWNER AND 1/z, 1/2" [NO, P PUMP (NSTALLED BY CONTRACTOR. - - 1/2" CW VTR VENT THRU ROOF 1/2" HW " WC WATER CLOSET 1/2" HW TO OTHER PLUMBING EQUIPMENT SCHEDULE UR URINAL FIXTURES 1/2" HWCW SHUT-OFF HL HAND LAVATORY CODE DESCRIPTION REMARKS TWH-1 TANKLESS WATER HEATER, CHRONOMII•E CM- MOUNT BELOW DECK( L-(No) LAVATORY TANKLESS HEATER 20L / 208, 4.16KVY, 208V, 1 PHASE FIXTURE MOUNTED TO WALL GREASE INTERCEPTOR, SIG DIPPER W 200-IS HB HOSE BIBB BELOW COUNTER 20 GPM FLOW RATE, 47 LB CAPACITY, 304 S.S. CONSTR1iCTION, AUTOMATIC GREASE INSTALL TO ACHIEVE SS SERVICE SINK 01-1 REMOVAL SYSTEM WITH INTEGRAL VENT, NECESSARY OPERATING I DF INSTALL. BELOWSINK. 120V-10, 10�2 AMPS - SERVICING CLEARANCES. DRINKING FOUNTIAN CONNECT TO PROVIDED BELOW COUNTER EWC ELECTRIC WATER COOLER POWER OUTLET. EWH ELECTRIC WATER HEATER DETAIL OF INSTALLATION OF GWH GAS WATER HEATER TANKLESS WATER HEATER N.T.S. SH SHOWER HS HAND SINK FD FLOOR DRAIN RD ROOF DRAIN -Do- GATE VALVE -p"o-- GLOBE VALVE -� CHECK VALVE -0a voa- BACK FLOW PREVENTER Big Dipper® IS Point Source Automatic w Grease Removal Systems W-200-IS Specifications ATHERMACCy TechnologypAff PRODUCT FEATURES • Fully automatic self cleaning cycle. Actively removes collected grease& oils from tank without any operator assistance. Comes complete with Digital Control user interface and Grease Collector. • Constructed of corrosion resistant materials suitable for installation in virtually any location, Attractive sanitary Stainless Steel exterior. • Integrated Motor/Grease Outlet/Heater/Lid enables a fast, do-it-yourself unit operation reversal. • Patent Pending Advanced Odor Protection design locks in odors from grease and solids. • Compact footprint. • Two provided. END VIEW ('(2)N/o--/H�ub/Connectors �CIFIC�lTIONS 24.10 .....------------- Construction: Exterior: 304 Stainless Steel, Bright Finish Injection Molded Polymer �i�o nvr mxxoN Interior: Rotationally Molded Polyethylene Electrical: 115 VAC, 50160 Hz, 1173 Watts It 0.2 Amps)* Electrical Cord Length: 8 feet Flow Rating: ---------- _.-_.-____.-_____-_.20 GPM (1.26I/s) 0 No. of Skimming Wheels: t +Skimming I Rate: 9 Pounds (4.08 Kg) Per HourGrease zs6m zmTMLME150�1lap RetentionC acit y: 47 Pounds (21.4 Kg) u. mm1 Qr',_E,Internal Solids Strainer Capacity:._ 1.85 Gallons (7 Liters) inlet/OutieV 2"(50 num e]ei Product Weight: 43 Ids (19.5 Kg) (,.44tsai'm"n] Rzz.9 mm]-'i •ForAdditional Electrical Configurations, sea Ehoe doa! Variations secfron on page 2. SIDE VIEW TOP VIEW -- - :SlE In Nor Zmm] eovaM BOTIRM C£T. RE(NEFlgOIIK II0.EDkR IP�3I mm± STWNE0.PAEMEr PNO r fDVER REfVIPL FSn.Omm� 4291n _ET xU GREASE WlrEn'OR 13w.0 mm] II&Et OUTLET INLET ],4 Q""T iT.] OeRET toezm asOm UwaaTY Lla_t mm] 6Wn it 33651n ]ns 3 mm] £ S o m 1� C E ©2019 Thermaco, Inc. • All rights reserved • Patented/Patents Pending • Specifications subject to change without notice 7f19 Theirmaco, Inc. • PO Box 2548 • Asheboro, NC 27204-2548 • (800) 633-4204 • www.big-dipper.com 1 FUNNEL AIR GAP TRANSITION VENT OVER TO WALL THEN UP IN WALL Wcul I ►I 212101aLTAXL1111111110 (3) COMPARTMENT KS L NOTE: COMPARTMENTS SHOULD NOT BE DRAINED SIMULTANEOUSLY. PER FBC PLUMBING 1003.3.4 a 1003.3.4.1 - TABLE 1003.3.4.1 FIXTURE FLOW RATE 3 COMP. SINK (SEE CALCS. BELOW) 17.52 GPM TOTAL 17.52 GPM GREASE INTERCEPTOR FLOW RATE PROVIDED 20 GPM - 47 LB, VALVE IN YARD BOX (TYPE AS NOTED) PRESURE RELIEF VALVE (RV) �M - WATER METER -O ELBOW -UP E)-- RISE OR DROP - CONCENTRIC REDUCER DIRECTION OF FLOW C.O? CLEAN OUT (RISER) -C.O. ' 4 C.O. CLEAN OUT III WALL CLEAN OUT }� PLUGGED PIPE 797- SHOWER HEAD �- PUMP W/FLOW DIRECTION FLOW SWITCH _ PRESSURE SWITCH �A,B,C,D WATER HAMMER ARRESTER WITH P.D.I. SIZE I. PLUMBING CONTRACTOR IS TO FURNISH AND INSTALL ALL PLUMBING FIXTURES COMPLETE AS (LISTED IN "PLUMBING FIXTURE SCHEDULE". 2. PLUMBING CONTRACTOR MAY USE SCHEDULE 40 OR 80 TYPE I, GRADE I, POLYVINYL CHLORIDE PIPE FOR ALL SOIL, WASTE AND VENT PIPING WHERE PERMITTED BY LOCAL CODES. WHERE PVC PIPING IS NOT PERMITTED BY LOCAL CODES, USE STANDARD WEIGHT CAST IRON PIPING. ALL PIPING ABOVE GRADE MAY HAVE HUBLESS FITTINGS. PLASTIC PIPING SHALL NOT BE USED IN A RETURN AIR PLENUM. COORDINATE THIS REQUIREMENT WITH H.V.A.C. CONTRACTOR. 3. PROVIDE SHUT-OFF GATE VALVES ON ALL EQUIPMENT & HOSE BIBBS, 81 STOP COCKS IN HOT AND COLD WATER PIPING TO ALL PLUMBING FIXTURES. PROVIDE SHUT-OFF GATE VALVES AT THE TOP OF EVERY WATER DOWN FEED PIPE a AT THE BASE OF EVERY WATER RISER. 4. ALL WATER PIPING BELOW GRADE SHALL BE TYPE "L" SOFT TEMPERED COPPER AND ALL WATER PIPING ABOVE GRADE SHALL BE TYPE "L" HARD TEMPERED COPPER. 5. INSTALL I" FOAM RUBBER INSULATION ON ALL HOT WATER 8 HOT WATER RETURN PIPING ABOVE 81 BELOW GRADE. ALL JOINTS IN INSULATION ARE TO BE TAPED. 6. ELEVATION OF ALL FLOOR DRAINS SHALL BE HELD I/2" BELOW FINISH FLOOR TILE. 7. ALL MATERIAL AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH ALL LOCAL AND STATE PLUMBING AND MECHANICAL CODES, INCLUDING THE STANDARD BUILDING, PLUMBING AND MECHANICAL CODES, NFPA, ASME, ASHRAE, ASA AND AGA. 8. THE SANITARY SYSTEM INCLUDES CONNECTION TO FIXTURES, RUNNING OF SOIL AND WASTE LINE AND SOIL AND VENT SANITARY SEWER SYSTEM AND/OR SEPTIC TANKS AND DRAIN FIELDS AND ALL ITEMS AS SHOWN ON DRAWINGS. VENT STACKS SHALL EXTEND THROUGH ROOF WRTH LEAD FLASHING. 9. THE DOMESTIC WATER SYSTEM INCLUDES CONNECTIONS TO THE DESIGNED SYSTEM, CONTROL VALVES AND PIPING TO PLUMBING FIXTURES, INCLUDING CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS. 10. PIPE INSTALLATIONS AND MATERIALS SHALL BE AS REQUIRED TO MAINTAIN FIRE RATINGS WHERE REQUIRED BETWEEN FLOORS AND/OR BETWEEN UNITS. 11. ARRESTERS SHALL BE INSTALLED WHERE NECESSARY TO PREVENT WATER HAMMER. 12. COPPER PIPING WHERE USED SHALL NOT CONTACT DISSIMILAR METALS OR MASONRY. PROVIDE ISOLATING BUSHINGS WHEN CONNECTING TO ANY DISSIMILAR METALS. 13. PLUMBING CONTRACTOR SHALL COORDINATE WITH ARCHITECT FOR DETAILED DIMENSIONS AND LOCATIONS OF ALL FIXTURES AND EQUIPMENT AND FOR ANY CHANGES IN LAYOUT. 14. PLUMBING CONTRACTOR SHALL MAKE ALL TEST AND ADJUST- MENTS AS REQUIRED, UPON COMPLETION OF WORK AND PRIOR TO FINAL ACCEPTANCE BY OWNER. 15. AFTER COMPLETION OF THIS WORK, THE CONTRACTOR SHALL OBTAIN A CERTIFICATE OF FINAL INSPECTION AND APPROVAL FROM ALL AUTHORITY'S HAVING JURISDICTION. 16. ALL WORKMANSHIP, MATERIALS AND APPARATUS UNDER THIS CONTRACT SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY THE OWNER. 17. THESE DRAWINGS ARE PREPARED PER ESTABLISHED INDUSTRY STANDARDS AND REPRESENT THE ENGINEERS DESIGN CONCEPT. THEY ARE NOT INTI NDED TO PROVIDE EVERY DETAIL OR CONDITION REQUIRED TO CONSTRUCT THE BUILDING. THE CONTRACTOR THROUGH SUBMITTALS AND OTHER COORDINATION EFFORTS IS FULLY RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERATIONAL BUILDING WHETHER INDICATED ON THE PLANS OR NOT. 3 COMP. SINK DRAINAGE (PER SINGLE COMPARTMENT) PLUMBING DRAWING INDEX 15"W x 15"L x 8"D = 1600 IN^3 1800 IN^3 / 2311N^3 PER GAL = 7.79 GAL 25% DISPLACEMENT BY WASH ITEMS: 7.79 x 0.75 = 5.64 GAL SHEET DESCRIPTION ISSUED DRAINAGE FOR ONE MINUTE PERIOD: 5.84 GAL / I MIN = 5.84 GPM 5.84 GPM X 3 COMPARTMENTS = 17.52 GPM TOTAL _ P-1.0 PLUMBING LEGEND, NOTES, SCHEDULES s DETAILS YES GREASE INTERCEPTOR DETAILS P-2,1 PLUMBING PLAN NTS YES P-3.1 PLUMBING WASTE -VENT AND WATER RISER YES REVIEWED FOR "ODE COMPLIANCE S", LUCIE COUNTY SOCO NI z 0 to of W 0 61 z Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a 0 v; � Lj QO U W < z a l.i aw w w n. o O D O O d C.)OD tL rn W z - g O O > z ,H••1 < = J lL w I- d o � W v t 111 04 O (!) a. NLLI O I1T 'o rn 0 ^LL a- /D u_ LL III'---�YYI ENGINEER SEAL J ' • V so6'�I *.' N 982 • * C TATEOF �:W. 44/ 4 OR \•�r.G'91�`: Eric J. Svoboda, PE P.E. No. 60982 "ESE Dom"n, RUNG V LIE 1131 RIO A Itsow 'RESEWE➢ 16F➢1 NE Maw OLY EOt 11E S clnc SHEET TITLE PLUNIBING LEGEND, NOTES, SCHEDIJLES & DETAILS SSUE DATE: 09-28-2021 DRAWN: EJS APPROVED: EJS I DRAWING NUMBER I NW# NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. SHEET I OF 3 21001-12 Y U K O c- PLUMBING PLAN SCALE 1/4" = V-0" GENERAL NOTES: I. FIELD VERIFY EXISTING WASTE INVERT ELEVATIONS PRIOR TO ROUTING NEW LINES. 2. SAW -CUT FLOOR AS NECESSARY 8 PATCH TO MATCH EXISTING. 3. ROUTE NEW WATER LINES IN OR ALONG WALL AS INDICATED. KEY NOTES: ID LOCATE a TIE INTO EXISTING WASTE. 20 LOCATE a TIE INTO EXISTING WATER. 3� LOCATE 81 TIE INTO EXISTING VENT ABOVE CEILING. ® PROVIDE ASSE 1070 APPROVED BELOW DECK MECHANICAL MIXING / TEMPERING VALVE. SET AT MAX 110 DEG FOR HW. 5O PROVIDE BIG DIPPER, W-200-IS, 20 GPM, 47 LB GREASE CAPACITY, AUTOMATIC GREASE INTERCEPTOR ON FLOOR BELOW SINK. ROUTE 3 COMP. SINK TO INLET; OUTLET TO SANITARY IN WALL. SEE DETAIL ON SHEET P-I. REQUIRES 120V 10.2A CIRCUIT. INSTALL TO ACHIEVE NECESSARY OPERATING / SERVICING CLEARANCES. REVIEWED R ,..,ODE COMPLIANCE T. LUCIE qq�//^^C/U'J T'Y �?C. CC F- z� Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone:772 672-4636 Fax: 772 672-4637 a .0 WIt 0 a0 7U W U_ D - z aw U Q W J Wa 0 O w� z W oov -L U CO Li fM W Z — O J Q F Q 2 W Z Q0 w O (n U ~ � J W U F W U n a C O F O> D W (D O a (D W ENGINEER SEAL J�Sv OQ i� N 82 • �* �, STATE OF 4u �� O� ;• •� .4OR\V-'• Eric J. Svoboda, PE P.E. No. 60982 n� maAnrts nnan wnm, wnm¢nnw xm ANMAI➢N BY i9R w vmmmA;, ➢IC. K MLL W V1110Jr LNN 11E SAIE �Ym20w, NR ruacc u+mmEM �, wc. xi warts snrom I SHEET TITLE 1 PLUMBING FLOOR PLAN 1 """ AAA" 09-213-2021 1 DRAWN: EJS APPROVED: EJS I DRAWING Nl1MBER I SHEET 2 OF 3 21001-12 i i ' I I i I i i i i i i i i i N5, WASTE - VENT RISER SCALE: N.T.S. WATER RISER SCALE: N.T.S. CODE C PUANCE P x� BOCC 3 Port Fierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 Q 0 wOf U Q O J O W Q W U O Q cr W W W d H O LZJ U to D'0) CC O O V cou- rn W Z — O o > Q E� a = Z ^�^ U Fri —j U ¢ H W W w v a O W o m ¢ CL a (D O- d ENGINEER SEAL O@ *fit No 982 _-� g.�0-zi � . � TA EOF �. '• G �i S ••........ �riNtit1%%NN`` Eric J. Svobodo, PE P.E. No. 60982 SHEET TITLE PLUMBING WASTE -VENT AND WATER RISER ISSUE DATE: 09-28-2021 DRAWN: EJS APPROVED: EJS DRAWING NUMBER P-3m, 1 SHEET 3 OF 3 21001-12 ELECTRICAL SYMBOL LEGEND SPECIFICATIONS: r TELEPHONE/DATA SYSTEM FIRE ALARM/DETECTION SYSTEM BASIC MATERIALS BASIC MATERIALS CONT. I. THE TOTAL ELECTRICAL INSTALLATION MUST MEET THE REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA ADMINISTRATIVE CODE (FAC), SECTION 61G15-33, 41. WORKMANSHIP, MATERIALS AND APPARATUS UNDER THIS CONTRACT SHALL BE o AND, BY REFERENCE IN THE FAC, THE FLORIDA BUILDING CODE, 7TH EDITION, GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL (2020), THE FLORIDA FIRE PREVENTION CODE, 7TH EDITION, (2020), AND THE 2017 ACCEPTANCE BY TtIE OWNER. SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION EDITION OF NFPA 70, THE NATIONAL ELECTRICAL CODE. 42. GREATER THAN 80% NONLINEAR LOADS: SHARED NEUTRALS AND GROUNDS ARE PHONE/DATA OUTLETS MOUNTED AT RECEPTACLE � MANUAL PULL STATION Sa SINGLE POLE SWITCH (SUBSCRIPT INDICATES ITEM CONTROLLED) B AUTOMATIC TRANSFER SWITCH 2. ON ALL ELECTRICAL PLAN SHEETS, E.G. NE -I', 'E-2.1', ETC., THE TERM 'CONTRACTOR' SHALL MEAN "ELECTRICAL CONTRACTOR', SOMETIMES ALSO 43. NOT PERMITTED FOR SINGLE PHASE CIRCUITS. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE HEIGHT UNLESS OTHERWISE NOTED. C I ABOVE THE COUNTER M = NUMBER OF DATA PORTS, DEFAULT = I ® CEILING SMOKE DETECTOR, PHOTOELECTRIC S3 THREE-WAY SWITCH NON -FUSED DISCONNECT SWITCH, AMP RATING / # OF POLES 3. ABBREVIATED AS 'E.C.'. MATERIALS AND EQUIPMENT INSTALLED SHALL BE ENTIRELY NEW, UNLESS 44. WITH NEC 110, AND WITH NEC 210,8 FOR GFCI DEVICES. THE EXCLUSIVELY -DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL N = NUMBER OF PHONE PORTS, DEFAULT = I TYPE UNLESS OTHERWISE NOTED S4 FOUR-WAY SWITCH NEMA I IF INDOORS NEMA 3R IF OUTDOORS OTHERWISE NOTED, AND SHALL BE LISTED BY UNDERWRITERS LABORATORIES. CEILING WITH A WIDTH AND DEPTH OF THE PANEL BOARD OR SWITCHBOARD MUST M DATA OUTLET, 8P8C E ELEVATOR WITH RECALL CONTACTS Sp DIMMER SWITCH 4. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE BE CLEAR OF ALL PIPING, DUCTS OR EQUIPMENT FOREIGN TO THE ELECTRICAL N I = IONIZATION (1500 WATTS UNLESS OTHERWISE INDICATED) FUSED DISCONNECT 30AR ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. EQUIPMENT OR ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 408. > DUCT SMOKE DETECTOR, SIMPLEX 4098-9686 OR EQUAL AR DENOTES AMP RATING OF SWITCH 20AF 5. CONTRACTOR TO REMOVE AND INSTALL ELECTRICAL EQUIPMENT IN ACCORDANCE 45. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE -RESISTIVE ASSEMBLIES, N PHONE OUTLET, RJ II S F CEILING FAN/LIGHT CONTROL, DAN'S FAN CITY #423LW OR EQUAL AF DENOTES AMP FUSE SIZE WITH THESE PLANS, FROM THE FUSED DISCONNECT AT THE SERVICE ENTRANCE (CLASSIFIED AS FIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED SA =SIMPLEX 4098-9687 0R EQUAL WHITE COLOR MCP � DENOTES FUSE PER MANUFACTURER RECOMMENDATIONS AND BRANCH -CIRCUIT PANEL 'PI' TO AND INCLUDING ALL EQUIPMENT SPECIFIED ON WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING k COMBINED DATA/PHONE OUTLET, 8P8C/RJII SK SINGLE POLE KEY SWITCH SIZE # OF POLES 6. THESE PLANS AND EQUIPMENT FURNISHED BY OTHERS AS MAY BE REQUIRED. SPECIAL CONDITION I: THE EXISTING PANEL DIRECTORY CONDITIONS AND FBC 714 SHALL BE MET: M N RELAY �� IS SERIOUSLY OUTDATED. A. ALL ELECTRICAL BOXES SHALL BE METALLIC. ® SUPERVISED CONTROL SY THREE-WAY KEY SWITCH ®.I 30/3 COMBINATION MAGNETIC MOTOR STARTER, SIZE a # OF POLES THE E.C. SHALL ALLOT TIME TO TRACE ALL REASONABLY ACCESSIBLE LOADS TO ® TELEPHONE OUTLET FLOOR MOUNTED R DUCT DETECTOR REMOTE ALARM INDICATOR AND, S4K FOUR-WAY KEY SWITCH 3R 0 3 POLE UNLESS OTHERWISE NOTED ENCLOSURE NEMA RATING. THEIR CORRECT CIRCUIT BREAKER AND PROVIDE AND INSTALL AN UPDATED PANEL DIRECTORY. IT SHALL BE UNDERSTOOD THAT SOME PREVIOUS LOADS AND CIRCUITS B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE. SL SINGLE POLE SWITCH WITH SECURITY LOCKING KEY TEST STATION, WALL MOUNTED 72 AFF, NEMA STARTER SIZE MAY BE VERY DIFFICULT TO TRACE AND SUCH MAY BE MARKED 'NO LOAD', BUT TTB SIMPLEX 4098-9835 OR EQUAL SLV LOW VOLTAGE SWITCH OTHERWISE LEFT IN THE 'ON' POSITION. C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. ® TELEPHONE/COMPUTER TERMINAL BOARD DUCT DETECTOR REMOTE A/V CONTROL STATION SM MOTOR RATED SNAP SWITCH, IHP MIN., 20A, 120/277V BRANCH CIRCUIT PANEL BOARD, UNDER 250 'VOLTS, SURFACE MOUNTED 7, SPECIAL CONDITION 2: FEEDER CONDUCTOR LABEL INDICATES THE FEEDER IS 1/0 " LEVITON 1121-2 OR EQUAL COPPER. E.C. SHALL PROVIDE AND INSTALL 150A CURRENT LIMITING FUSES IN THE D. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED w WITH TEST SWITCH, WALL MOUNTED 72 AFF, -� BRANCH CIRCUIT PANEL BOARD, UNDER 250 VOLTS, TENANT FUSED DISCONNECT. 1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE o rE�C TELEPHONE TERMINAL CABINET SIMPLEX 4098-9842 OR EQUAL SMP MANUAL MOTOR STARTER WITH OVERLOAD HEATERS AND FLUSH MOUNTED 8. CONTRACTOR SHALL ASSIST THE OWNER IN OBTAINING A FAULT CURRENT LETTER. OPENING. T o4 COMBINATION AUDIBLE/VISUAL PILOT LIGHT BRANCH CIRCUIT PANEL BOARD, OVER 250 VOLTS, 9. SERVICE EQUIPMENT SHALL BE MARKED WITH THE MAXIMUM AVAILABLE FAULT CURRENT AMPERES VFCA") PER NEC 110.24 AND �\ TELEPHONE SYSTEM RACEWAY NOTIFICATION DEVICE SIPSINGLE POLE SWITCH WITH PILOT LIGHT SURFACE MOUNTED THE DATE OF THE MARKING. SEE E. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE o XXCD CD = CANDELA RATING, MINIMUM 75 CD PER SR SINGLE POLE SWITCH CONTROLLING SWITCHED RECEPTACLE BRANCH CIRCUIT PANEL BOARD, OVER 250 VOLTS, 10. RISER DIAGRAM SHEET E-2.1 FOR FAULT CURRENT CALCULATED VALUES. CONTRACTOR TO COMPLETE ALL WORK INCIDENTAL TO THE PLUMBING TRADE FOR A COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). z Fort P1eTC2 TELEVISION RACEWAY SYSTEM FBC II-4283(41 .. STD SINGLE POLE SWITCH -TIME DELAY FOR EXHAUST FAN/LIGHTS FLUSH MOUNTED COMPLETE INSTALLATION, INCLUDING CONTROL WIRING, MOTOR STARTERS, DISCONNECT SWITCHES AND EQUIPMENT GROUNDS. F. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 SQUARE INCHES. THE Engineering, 1 Ell T10eT']LTl Inc.SS FIRE ALARM SPEAKER - CEILING MOUNTED SwP SINGLE POLE SWITCH WITH WEATHERPROOF COVER BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL. 11. DEFERRED SUBMITTALS FOR ANY LOW VOLTAGE SYSTEMS SHALL BE SUBMITTED TO INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. Dependable Mechanical, Electrical SWST SPRING WOUND WALL SWITCH TIMER (30 MIN.) CONDUIT SHALL INCLUDE PHASE, NEUTRAL AND GROUND CONDUCTORS THIS ENGINEER AND TO THE BUILDING OFFICIAL PRIOR TO INSTALLATION. & Plumbing Design Reg. No.28173 Q TELEVISION OUTLET FOR ANTENNA 1© WALL MOUNTED SPEAKER WITH STROBE AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED). CONTRACTOR TO MAKE NECESSARY PROVISIONS FOR THE INSTALLATION OF ANY G. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 XXCD CD = CANDELA RATING Clc= DUPLEX RECEPTACLE, 5-20R UNLESS OTHERWISE NOTED AND ALL SYSTEMS FOR THIS PROJECT, INCLUDING RACEWAYS, CABINETS, PULL SQUARE INCHES PER 100 SQUARE FEET OF WALL AREA. TELEVISION SIGNAL WALL OUTLET BRANCH CIRCUIT CONDUIT CONCEALED IN SLAB, BOXES AND OUTLETS. SEE SHOP DRAWINGS FOR EACH SYSTEM FOR ADDITIONAL RACEWAY ® FIRE ALARM SPEAKER -WALL MOUNTED T� SINGLE 5-20R RECEPTACLE, T DENOTES TWIST -LOCK UNDERGROUND OR UNDER FLOOR. DETAILS AND INSTRUCTIONS. H. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE -RESISTIVE ASSEMBLIES ,,,,,TV --,.,TV DISTRIBUTION SYSTEM GFCI DEAD FRONT/BLANK (ACED, WHITE GFCI DEVICE. -'---'--BRANCH - CIRCUIT CONDUIT EXPOSED 12. NEW DISCONNECT SWITCHES SHALL HAVE COPPER OR COPPER (NOMINAL 15% BY SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. EATON # SGFD20 W. MOUNTED AT 48" AFF OR EQUAL VOLUME) CLAD ALUMINUM BUS. ❑M MAGNETIC LOCK FIRE ALARM SPEAKER WITH STROBE -CEILING MOUNTED III-- GROUND OR GROUND ROD AS NOTED 13. TYPEWRITTEN CIRCUIT IDENTIFICATION SHALL BE UPDATED IN THE PANELBOARD, I. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS. CD = CANDELA RATING SURGE PROTECTION TYPE (NSS) EACH BREAKER HAVING A DISTINCTIVE DESCRIPTION COMPLYING WITH NEC 408.4(A). 0< CCTVCAMERA W/ CONDUIT TO VIDEO SP DUPLEX RECEPTACLE ,_-EMS EMERGENCY BRANCH CONDUIT ALL PANELBOARDS SHALL BE MARKED WITH THEIR SOURCE OF SUPPLY PER NEC JUNCTION BOX F VISUAL SIGNALING UNIT, WALL MOUNTED ® PEDESTAL MOUNTED RECEPTACLE 408.40. "GRC", 'IMC" (NO AUDIO DEVICE) -_0UP CONDUIT TURNING UP 14. CONDUIT FOR ABOVE GRADE SHALL BE 'SCH 80 PVC' OR "EMT". I PTZ PAN/ TILT/ ZOOM CCTV CAMERA W/CONDUIT ® FLOOR OUTLET BOX AND DUPLEX RECEPTACLE "LFNC' SHALL BE USED FOR CONNECTIONS TO THE WATER HEATER AND OTHER TO VIDEO JUNCTION BOX - MOUNTED MIN 15' -© FIREMAN S PHONE JACK WITH APPROPRIATE FLANGE. -� CONDUIT TURNING DOWN DN EQUIPMENT. MC CABLE MAY BE USED FROM 'J-BOXES" IN CEILING, OR, WHEN STUDS AFF OR o CEILING ® FLOOR OUTLET BOX WITH DUPLEX RECEPTACLE OR OTHER POINTS OF SECURE SUPPORT NOT GREATER THAN 6 FEET APART ARE AVAILABLE, FROM BRANCH -CIRCUIT PANELS 0 SPRINKLER TAMPER SWITCH CONNECTION ® AND ONE COMBINATION W/ VOICE/DATA OUTLET FLOOR OUTLET BOX WITH TWO DUPLEX RECEPTACLES AND ONE COMBINATION W/ VOICE/DATA OUTLET ] CONDUIT STUB --z CONDUIT CONTINUED 15. TO SWITCHES, RECEPTACLES AND BETWEEN DEVICES. SPARE CONDUITS SHALL HAVE A PULL WIRE INSTALLED. CONDUCTORS SHALL BE COPPER THHN/THWN EXCEPT WHERE SPECIFIED OTHERWISE 315 South 7th Street Fort Pierce, FL. 34950 Phone: 72672-4637 SYNCHRONOUS MASTER CLOCK SYSTEM SPRINKLER WATER FLOW ON THE DRAWINGS. CONDUCTORS NO. 8 AWG AND LARGER SHALL BE JOINED BY Fax: 772 672-4637 ❑ SWITCH CONNECTION © POKE THRU FLEXIBLE CONDUIT AN APPROVED PRESSURE CONNECTOR. CONNECTION TO GROUND CONDUCTORS NO. PP POWER POLE EXISTING TO BE REMOVED 1/0 AWG AND LARGER SHALL BE CAST BY FUSIBLE METAL PROCESS. ALL SYNCHRONOUS SYSTEM CLOCK p FIRE ALARM SYSTEM PRINTER CONDUCTORS MUST BE INSTALLED IN CONDUIT, MC CABLE, OR LFNC. CONDUCTORS SINGLE POLE SWITCH/RECEPTACLE COMBINATION EXISTING TO REMAIN IN PANELS SHALL HAVE THEIR FACTORY LABELS VISIBLE TO A PERSON IN THE FFAATTC MASTER CLOCK CONTROL PANEL AA ZONE ADDRESSABLE MODULE S DUPLEX RECEPTACLE WITH EACH HALF ON SEPARATE CIRCUIT 16. WORKING SPACE. CONDUCTORS OF MULTIWIRE (BREAKER SHALL BE TWO POLE WITH COMMON TRIP) EXISTING AFFECTED BY THIS PROJECT CIRCUITS SHALL BE GROUPED IN AT LEAST ONE ® ELECTROMAGNETIC DOOR HOLD OPEN DEVICE LOCATION WITHIN THE PANELBOARD OR OTHER POINT OF ORIGIN BY WIRE TIES OR MASTER CLOCK SYSTEM CONDUIT AND WIRING DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER - FUTURE SIMILAR MEANS PER 200.4(B). MULTIWIRE CIRCUIT DISCONNECTS SHALL BE ELECTROMAGNETIC DOOR HOLD OPEN DEVICE CONNECTION TO CLOSURE/ HOLDER � DUPLEX TAMPER -RESISTANT RECEPTACLE. MOUNTNEWH COVER PLATE WITH SPANNER HEAD SCREWS _ PROVIDED WITH A MEANS TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES. 17. COLOR CODE FOR 20BY/120V 3e SYSTEM SHALL BE: BLACK, RED, BLUE, WHITE, 8 DOORBELL SYSTEM IgH ELECTROMAGNETIC DOOR HOLD OPEN DEVICE DUPLEX RECEPTACLE WITH TOP HALF SWITCHED LIGHTING GREEN. ST.LUCIE000NIY o CONNECTION TO CLOSURE/ HOLDER INCLUDES DETECTOR GFCI RECEPTACLE (EWC DENOTES ELECTRIC 18. CONTRACTOR SHALL VERIFY WITH ARCHITECT FOR DETAILED DIMENSIONS AND LOCATIONS OF OUTLETS AND EQUIPMENT AND FOR ANY REVISIONS IN PLAN REVIEW > 0 a o - LAYOUT. 4 • DOOR PUSH-BUTTON STATION OH CEILING HEAT DETECTOR 135 F UNLESS OTHERWISE EWC WATER COOLER. COORDINATE WITH EWC INSTALLER FOR MOUNTING HEIGHT) I--O-� LINEAR OR STRIP FIXTURE 19. " MOUNT WALL SWITCHES 44 ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON w u � z w WP =WEATHERPROOF INDICATED. � GFCI RECEPTACLE. WP DENOTES WEATHERPROOF COVER. FIXTURES A LAY -IN TROFFER FIXTURE 20. DRAWING. GANG SWITCHES WHEREVER POSSIBLE. LIGHTING CONTROLS SHALL CONFORM TO THE REQUIREMENTS LISTED ON THE E-3 BLDG: a ° a � DB DOORBELL CHIME (SELF CONTAINED) BEAM DETECTOR - TRANSMITTER WP DESIGNATION SERIES SHEETS IN THESE PLANS. CONTROLS SHALL BE WHITE OR' IVORY IN DATE; u _j w o GFCI RECEPTACLE MOUNTED ABOVE COUNTER CIRCUIT--2 a- OWER CASE LETTER INDICATES LIGHTING CONTROL COLOR. SWITCHES CONTROLLING LINE -TO -NEUTRAL LIGHTING LOADS SHALL ELEC' 0 z Lo DOORBELL SYSTEM CONDUIT AND WIRING BEAM DETECTOR -RECEIVER GFq DEAD-FRONT/BLANK FACE GFCI, EATON SGFD20 OR EQUAL NUMBER LAY -IN TROFFER FIXTURE ® 21. COMPLY WITH NEC 404.2(C). RECEPTACLES SHALL BE LOCATED 15" ABOVE FINISHED FLOOR TO CENTER LINE OF DATE'-�-�- o o v cJi CO " FACP o FIRE ALARM CONTROL PANEL DIAGONAL SHADING DENOTES EMERGENCY LIGHT FIXTURE. DEVICE, UNLESS OTHERWISE NOTED. ABOVE -COUNTER RECEPTACLES SHALL BE PLUNIti: FATC TWO DUPLEX RECEPTACLES WITH COMMON COVER � WRAP AROUND OR SURFACE MOUNTED FIXTURE. 22. MOUNTED 6" ABOVE BACK SPLASH TO CENTERLINE OF DEVICE. COVER PLATES SHALL BE WHITE PLASTIC, UNLESS OTHERWISE NOTED. DATE: - MEC f{: DOOR CONTROL SYSTEM r� FIRE ALARM TERMINAL CABINET TWO RECEPTACLES WITH COMMON COVER WALL MOUNTED VANITY OR CLOSET FIXTURE RECEPTACLES WITH GROUND PIN IS MOUNTED TIC COVER PLATES SHALL BE MOUNTED SUCH THAT THE DOWN, UNLESS DATE: MOUNTEDEX ABOVE COUNTER OTHERWISE NOTED. RECEPTACLES WITH $_ FIRE ALARM ANNUNCIATOR PANEL -FLUSH MOUNTED EXTERIOR WET LOCATION WALL MOUNTED FIXTURE METAL COVER PLATES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS C- CONTROLLED RECEPTACLE. BREAK OUT TAB FOR SPLIT 0 CEILING OR SOFFIT MOUNTED DOWNLIGIiT FIXTURE MOUNTED UP, UNLESS OTHERWISE NOTED. MOTION DETECTOR 360 OPERATION. SHALL BE MARKED IN FIELD PER 406.3(E). 23. ALL NEW 125V RECEPTACLES SHALL BE NEMA 5-20R, AND COLOR SHALL BE WHITE �F�„\FIRE ALARM SYSTEM CONDUIT AND WIRING 0 PENDANT OR BAY FIXTURE UNLESS NOTED OTHERWISE. OUTDOOR RECEPTACLES SHALL COMPLY WITH 406.9(A) ® CARD READER @_= ISOLATED GROUND DUPLEX RECEPTACLE, OR (B) AS APPROPRIATE TO CONDITIONS. AFCI AND GFCI TYPE RECEPTACLES SHALL ELECTRICAL ABBREVIATIONS QE FIREMAN S ELEVATOR WARNING LIGHT IG (ORANGE DEVICE) WALL WASH FIXTURE BE INSTALLED IN A READILY ACCESSIBLE LOCATION. K DIGITAL KEYPAD 24. CONTRACTOR SHALL CONNECT PUMPS AND OTHER EQUIPMENT. BALANCED MAGNETIC DOOR CONTACT ® KNOX BOX -LOCATION TO BE COORDINATED WITH THE AHJ � DUPLEX RECEPTACLE NOTE: 0- ACCENT FLOOD LIGHTING -AIMING AS (INDICATED 25. CONTRACTOR SHALL MAKE TESTS AND ADJUSTMENTS AS REQUIRED, UPON AFF: ABOVE FINISHED FLOOR L: LIGHTING LOAD AFG: ABOVE FINISHED GRADE TICK MARKS SHOWN ON ANY DEVICE REPRESENTS RECEPTACLE COMPLETION OF THE WORK AND BEFORE FINAL ACCEPTANCE BY THE OWNER. THE M: MOTOR LOAD � o PAGING SYSTEM &BACKGROUND MUSIC CONNECTED TO THE EMERGENCY CIRCUIT (RED DEVICE) TYPICAL FOR ANY DEVICE IN LEGEND EXIT LIGHT FIXTURE ® DIRECTION ARROWS AS SHOWN (SHADED CONTRACTOR SHALL TEST THE COMPLETE ELECTRICAL SYSTEM IN THE PRESENCE OF THE ENGINEER/ARCHITECT FOR CONTINUITY, FUNCTION, CONTROL, PERFORMANCE, BFC: BELOW FINISHED CEILING MBJ: MAIN BONDING JUMPER E.C.: ELECTRICAL CONTRACTOR MOUNTING HEIGHT a H z � Q i= 3 J a = o W INTERCOM SYSTEM ® SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED QUADRANT INDICATES FACE(S) OF FIXTURE) LOAD BALANCE, GROUNDS AND GROUND RESISTANCE, SHORT CIRCUITS, AND TO EGC: EQUIPMENT GROUNDING CONDUCTOR NL: NIGHT LIGHT NL: f: FAN LOAD I- _j � � ASTRONOMIC TIME SWITCH ABLE TO RETAIN WALL MOUNTED EXIT LIGHT FIXTURE INSURE SATISFACTORY OPERATION AND CONFORMANCE TO CONTRACT REQUIREMENTS.04 P: PANEL FCA: FAULT CURRENT AMPERES R: RECEPTACLE LOAD c� w U � w w U) a SO LOUDSPEAKER/ TRANSFORMER/ BAFFLE/ PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER �14COMBINATION EXIT/EMERGENCY LIGHT FIXTURE W/REMOTES 26. EQUIPMENT, LABOR AND MATERIAL REQUIRED FOR TESTING SHALL BE FURNISHED GC: GROUNDED CONDUCTOR SA: SMOKE/CO ALARM LOAD o W o m o IC MASTER STATION SUPPORT TRUSS. (CEILING MOUNTED) FOR A PERIOD OF AT LEAST 10 HOURS. o-❑ POLE MOUNTED AREA LIGHT FIXTURE WITH ARMS AS SHOWN BY THE CONTRACTORS) AS PART OF THIS CONTRACT. GEC: GROUNDING ELECTRODE CONDUCTOR SN: SOLID NEUTRAL w o_ (, 0 LL C = COUNTER W =WALL MOUNTED ® ON DRAWINGS 27. PRIOR TO COMPLETION OF THE WORK, THE CONTRACTOR SHALL MARK THE SERVICE GFI: GROUND FAULT CIRCUIT -INTERRUPTER UON: UNLESS OTHERWISE NOTED IG: ISOLATED GROUND D =DESK 0 LOUDSPEAKER/ TRANSFORMER/ BAFFLE/ PHOTOCELL, MOUNTED ON ROOF FACING NORTH PB ELECTRICAL PULL BOX EQUIPMENT WITH THE AVAILABLE FAULT CURRENT PER NEC 110.24, USING EITHER VP: VAPOR PROOF KE: KITCHEN EQUIPMENT WP: WEATHER PROOF ENGINEER SEAL W = WALL MOUNTED H = HAND SET TYPE ENCLOSURE FOR EXPOSED CEILING AREAS W = WALL MOUNTED ® GROUND BAR TRACK WITH TRACK LIGHT FIXTURE (TRIIANGLES -Q- THE FAULT -CURRENT FROM THE UTILITY FAULT CURRENT LETTER, OR THE SHORT CIRCUIT CURRENT CALCULATION FROM THESE PLANS. IF PROVIDED WITH THE +` TR���� HF = HANDS FREE ® PLUG-IN STRIP WITH RECEPTACLES, 18 O.C. UNLESS " INDICATE QUANTITY OF LIGHT FIXTURES) FAULT CURRENT LETTER, THIS ENGINEER WILL UPDATE THE CALCULATION TO `��o�N......... •�� CENF•,,/2�!� WP = WEATHER PROOF HORN/TRANSFORMER FOR HIGH NOISE AREAS OTHERWISE INDICATED ® BATTERY PACK WITH TWIN HEADS (CEILING MOUNT) OBTAIN THE FAULT CURRENT AT THE SERVICE ENTRANCE. ` \�S� IC INTERCOM SYSTEM SPEAKER ® UNDER GROUND CONCRETE ENCASED DUCTBANK BATTERY PACK WITH TWIN HEADS (WALL MOUNT) 28. AFTER COMPLETION OF THE WORK, THE CONTRACTOR SHALL SECURE CERTIFICATES OF FINAL INSPECTION AND APPROVAL FROM AUTHORITIES HAVING JURISDICTION r' No. 61580 ' Z W =WALL MOUNTED PAoEC _ PAGING SYSTEM EQUIPMENT CABINET QJ JUNCTION BOX 29. (AHJ)' PER FBC C405.6.4.1, WITHIN 30 DAYS OF ELECTRICAL SYSTEM ACCEPTANCE BY THE : 9/2el2 1 �: -) STATE OF : tp '. LIGHTING CONTROL SYSTEM ICEC r� INTERCOM EQUIPMENT CABINET PATC -(,� JUNCTION BOX- WALL MOUNTED AHJ, THE CONTRACTOR SHALL PROVIDE THE BUILDING OWNER WITH RECORD DRAWINGS OF THE ACTUAL INSTALLATION. THE RECORD DRAWINGS SHALL INCLUDE FILE CF'• :� c <v: ;/ OR 1 OP,: 1 o _ PAGING SYSTEM TERMINAL CABINET JUNCTION BOX- FURNITURE SYSTEM FEED A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND '�' 7ONA1.E? LCP i0 ICTC ■ CONDUIT SEAL -OFF FITTINGS 'J LIGHTING CONTROL PANEL FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. IF INTERCOM TERMINAL CABINET DR _� DOCTORS REGISTRY SYSTEM CONDUIT AND WIRING PROVIDED WITH COMPLETE FIELD MARKUPS ON THESE PLAN SHEETS, THE ENGINEER TimothyC. T e15w8yPE SP SURGE PROTECTIVE DEVICE SA WALL -MOUNTED, MANUAL ON/OFF SWITCH SHALL MODIFY THESE PLAN SHEETS INTO SAID RECORD DRAWINGS AND PROVIDE A 0 P.E.. No. Ei1580 C3 C3 = TYPE I, NEMA 4X, CITEL MDS300 OR EQUAL AND AUTOMATIC OFF OCCUPANCY SENSOR COPY TO THE OWNER AND TO THE CONTRACTOR AND RETURN THE ORIGINAL FIELD ° s "m ° °N Y M nE lC IC INTERCOM SYSTEM CONDUIT AND WIRING VC VOLUME CONTROL B3 = DISTRIBUTION BOARD DEVICE SEE RISER FOR RATING S P WALL -MOUNTED, ON PULSE /OFF PULSE BUTTON MARKUP TO THE CONTRACTOR. ELECTRICAL DRAWING INDEX = E A3 PANEL BOARD DEVICE, SQUARE D Q02175S8 OR EQUAL 30. PER FBC C405.6.4.2 WITHIN 30 DAYS 0 F ELECTRICAL SYSTEM ACCEPTANCE BY THE FIIF�0.E W =ff W MT PUa �EDMW, M M � w SSEC o SOUND SYSTEM EQUIPMENT CABINET GFCI DEAD FRONT/BLANK FACED, WHITE GFCI DEVICE. Fs-TiSHUNT-TRIP BUTTON - FLUSH MOUNTED UNLESS TIME SWITCH CONTROL PER FBC C405,2.2.1. INDEPENDENT 7-DAY PROGRAMMING AHJ, THE CONTRACTOR SHALL PROVIDE THE BUILDING OWNER AN OPERATING AND MAINTENANCE MANUAL FOR ALL ELECTRICAL SYSTEMS INSTALLED IN ACCORDANCE SHEET DESCRIPTION ISSUED � �� vam�Pn �� AA9PTAm v Mi PUM QGP�mwl M 9 w "°° aAenm m nE saw «"°"mzce• MT EATON # SGFD20 W. MOUNTED AT 48' AFF OR EQUAL OTHERWISE NOTED NEMA 3R FOR EXTERIOR LOCATIONS is HOLIDAY SETTING, 10 HOUR PROGRAM (BACKUP WITH THESE PLANS THAT REQUIRE MAINTENANCE. AT A MINIMUM, THE MANUAL E-1.0 ELECTRICAL LEGEND, SPECIFICATIONS 8 ABBREVIATIONS YES PE9i , n� A s & PVEa 'TITLE SSTC EDH-X ELECTRIC DUCT HEATER TWO-HOUR MANUAL OVERRIDE MODE. SHALL INCLUDE: SHEET o SOUND SYSTEM TERMINAL CABINET CONTROLLED RECEPTACLE. BREAK OUT TAB FOR SPLIT �1/V� INTERMATIC ET2800 SERIES OR EQUAL. A. EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT E-2.1 ELECTRICAL POWER SYSTEMS PLANS 8 SCHEDULES YES OPERATION. SHALL BE MARKED IN FIELD PER 406.3(E). BOTTOM RECEPTACLE TO BE CONTROLLED MOTOR CONNECTION D� PASSIVE INFRARED / ULTRASONIC OCCUPANCY SENSOR REQUIRING MAINTENANCE. ELECTRICAL S SOUND SYSTEM CONDUIT AND WIRING �MS PASSIVE INFRARED, 0-IOV DIMMING ® VARIABLE FREQUENCY DRIVE C =CEILING MOUNT W =WALL MOUNT B. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF SYMBOL LEGEND, SPECIFICATIONS & WALL SWITCH/OCCUPANCY SENSOR HD ELECTRIC HAND DRYER ® DAYLIGHT SENSOR EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. ABBREVIATIONS WATTSTOPPER # PW-3110W SMS ISSUE ®D DIRECT DIGITAL CONTROL PANEL SINGLE POLE SWITCH - PASSIVE INFRARED OCCUPANCY SENSOR C. NAME AND ADDRESS OF AT LEAST ONE QUALIFIED SERVICE AGENCY. DATE: 09-28-2021 L] TRANSFORMER ® LIGHTING ROOM CONTROLLER/POWER SUPPLY NOTE: DRAWN: TS/TEC TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. WITH THE FLORIDA BUILDING CODE 7TH EDITION (2020) AND THE FLORIDA FIRE PREVENTION APPROVED: TCT CODE 7TH EDITION (2020). DRAWING (NUMBER PEVIEWEE) FOR .. �100E GOW ``5'f�E, E-1120 BOC:.: SHEET I OF 2 21001-12 EXISTING SWITU TO BE REMOVES AND RELOCATED - P ARTIAL PLAN - EXISTING/DEMO SCALE 1/4" = 1'-0" EXISTING SERVICE WIRE WIRWAY EXTERIOR INTERIOR — — — — — — — — — — — I I I — — — — — — 1 I I I I y r 1 I I I I 11529 FCA I I i EXIST. I ; PANEL "PI' I I 1 EXISTING UTILITY F- — -I COMPANY METER 1150A I LM% T I I I I EXISTING 800A I L J T SERVICE DISCONNECT ¢— EXISTING (441/0 SWITCH I IN 2"C ' I I 1 r J 23780 FCA I N EXISTING 3P 200A FUSED DISCONNECT T -i SWITCH. CHANGE , FUSES TO 150A. ' I 1 ' I I 1 ' L----T--- � I I I , �_________ __ __________________J , EXISTING GROUND EXISTING (441/0, (1)#6GRD-20C EXISTING SERVICE CONDUCTORS TO UTILITY POLE WITH TRANSFORMERS ELECTRICAL RISER DIAGRAM N.T.S. SERVICE LOAD IT IS PROPOSED THAT THE ADDITIONAL 5.39KW LOAD FROM THE TWH-I AND THE GREASE REMOVAL SYSTEM ARE INCIDENTAL TO THE CAPACITY OF THE EXISTING 800A SERVICE. GENERAL DEMOLITION NOTES: COORDINATE SEQUENCING WITH OWNER AND OTHER CONTRACTORS. IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO PROTECT AND MAINTAIN THE INTEGRITY OF THE REMAINING DEVICES AND EQUIPMENT. ELECTRICAL CONTRACTOR SHALL VISIT AND EXAMINE THE SITE PRIOR TO CONSTRUCTION TO ASCERTAIN THE EXISTING CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION. DISCONNECT, REMOVE OR RELOCATE ALL EXISTING ELECTRICAL MATERIAL AND EQUIPMENT THAT INTERFERES WITH NEW INSTALLATION. THIS INCLUDES BUT IS NOT LIMITED TO PANELS, LIGHTING FIXTURES, WIRING DEVICES, SIGNAL EQUIPMENT, EXHAUST FANS, BASEBOARD HEATERS, UNIT HEATERS, ETC. SEE MECHANICAL DRAWINGS FOR HEATERS, EXHAUST FANS, ETC. WHICH MUST BE DISCONNECTED BY THIS CONTRACTOR FOR REMOVAL OR ABANDONMENT BY MECHANICAL CONTRACTOR. ALL REMOVED EQUIPMENT SHALL BE DISPOSED OF BY THIS CONTRACTOR UNLESS DIRECTED TO DO OTHERWISE BY THE OWNER. WHERE WORK BY GENERAL CONTRACTOR (WALL REMOVAL, NEW OR RELOCATED WALL OPENINGS, ETC.) RESULTS IN THE REMOVAL, RELOCATION OR REFEEDING OF ELECTRICAL DEVICES OR LIGHTING FIXTURES, THE ELECTRICAL CONTRACTOR SHALL DISCONNECT AND RECONNECT ALL ACTIVE DEVICES REMAINING. ANY SUCH CONNECTIONS SHALL BE CONCEALED UNLESS LOCATED IN UNFINISHED AREAS. ANY EXISTING PANEL HOME RUNS, WHICH WILL REMAIN WITHIN THE AREA, MAY BE RETAINED AND USED AS PART OF THE NEW CIRCUITRY OR REMAIN AS SPARE EMPTY CONDUIT. SUCH EMPTY CONDUIT(S) SHALL BE MARKED AS TO PANEL AND END LOCATIONS. EXISTING OUTLET BOXES AND CONDUIT WHICH ARE LOCATED PROPERLY FOR NEW WORK MAY BE REUSED FOR NEW DEVICES AND WIRE. WHERE CONDUIT TO BE REMOVED STUBS THROUGH FLOORS, WALLS AND CEILINGS, SUCH CONDUIT SHALL BE REMOVED TO THE POINT WHERE THE FINISHED SURFACES CAN BE PATCHED ADEQUATELY SO THAT NO EVIDENCE OF THE FORMER INSTALLATION REMAINS. ALL CONDUIT AND WIRE REMOVED SHALL BE REMOVED TO THE SOURCE OF SUPPLY. ALL CUTTING, CORING AND PATCHING REQUIRED FOR ELECTRICAL WORK SHALL BE BY THE ELECTRICAL CONTRACTOR. INSTALL A BLANK COVER PLATE WHERE REQUIRED. SPECIAL CONDITION 1: THE EXISTING PANEL DIRECTORY IS SERIOUSLY OUTDATED. THE E.C. SHALL ALLOT TIME TO TRACE ALL REASONABLY ACCESSIBLE LOADS TO THEIR CORRECT CIRCUIT BREAKER AND PROVIDE AND INSTALL AN UPDATED PANEL DIRECTORY. IT SHALL BE UNDERSTOOD THAT SOME PREVIOUS LOADS AND CIRCUITS MAY BE VERY DIFFICULT TO TRACE AND SUCH MAY BE MARKED NO LOAD', BUT OTHERWISE LEFT IN THE "ON' POSITION AFTER TESTING. REST ROOM 10 PANEL "PI' :10 G ( PI-14:16_ . I DELI AREA t H. > TOILET ROOM TION j R `," m' POWER SYSTEMS PLAN - SCALE 1/4" = 1'-0" EXISTING DUPLEX RECEPTACLE TO BE REMOVED 6 A 20A GFCI RECEPTACLE TO BE INSTALLED GREASE TRAP TWH-1 4.16KW-208V REFER TO PARTIAL PLAN EXIST/DEMO PLAN FOR ADDITIONAL INFORMATION ON THIS SHEET. SL4TltoEiia.l."0'TY WE: ELEC;%� DAT��:""l2-E" 2- PLUMS: DATE: MECH: DATE: VI , COMPLi SoC z 0 N 7 I Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone:772 672-4636 Fax:772 672-4637 a 0 wX Qo w-ui v O a?' U a� J w wa -1 0 O T J U OD Li M w z — LL z U O N U I J I W Ux � w n o Ld O W 0 rn (I: �y 0 O L1 /� IL (0 L ENGINEER SEAL ``tt1111tr11� C. T ���` O�••�CEN•�R�'�i . 6168 •S2 9/ief- 1�� A STATE OF : to. Timothy C. Tr PE P.E. No. 615 0 AORPiRNa BY fiRi PffRE F]INtFnPGr ➢IG 5111,1 � vtt,olr uneam m nE sac coPrwrHr©zog. mm ruxa a�m�. ac ai rs[w,s ,xnxvco. SHEET TITLE ELECTRICAL POWER SYSTEMS PLANS & SCHEDULES ISSUE DATE: 09-28-2021 DRAWN: TS APPROVED: TCT DRAWING NUMBER �o oil SHEET 2 OF 2 21001-12