ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
Low Slope Application
A, B, C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,4,5,6,7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5,6,7
Metal Roofs
A, B, D
1,2,3,4,5,6,7
Wood Shingles and
Shakes
A, B, D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7,
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
ST. LUCIE WORKS
Section A (General Information)
Master Permit No.
Contractors Name: Collins Roofing Inc.
4 Job Address 5709 Palm Dr, Fort Pierce, 34982
Process No.
License # CCC-058011
ROOF CATEGORY
w Slope ❑ Mechanically Fastened Tile O Mortar/Adhesive Set Tiles
Asphaltic Shingles ❑Metal Panel/Shingles OWood Shingles/Shakes
O Prescriptive BUR-RAS 1S0
ROOF ROOF TYPE-
0 New roof ❑ Repair 0 Maintenance Reroofing ❑ Recovering
. ROOF SYSTEM INFORMATION
4 Low Slope Roof Area (SF) 300 Steep Sloped Roof Area (SF) 1100 Total (SF) 1400
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Owens Corning
Roof System Manufacturer: —
Notice of Acceptance Number:
FL 10674-R16
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 81.7
4 Zone 1: 39 Zone 2e: 39 Zone 2n: 74.5Zone 2r: 74•SLone 3e:—Zone 3r:
Deck Type: 5/8" Plywood
Type Underiayment Self Adhesive Underlayment APOC
Roof Slope.,
4 . 12 Insulation: N/A
Fire Barrier: I N/A
Ridge Ventilation? Fastener & Spacing: 6 Nails PerShingle - 1 1/4 Coil N Is a
Adhesive Type: Bituman Tar
Type Cap Sheet N/A
Mean Roof Height: 15 ft Roof Covering: Dimensional Asphault Shingles
__7
Type & Size Drip 2"x2" Galv. Steel
Edge:
ST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: Polyglass
Product Approval No.: FL 1654
Design Wind Pressures, From RAS 128 Or Calculations:
53.3Z -53.3 -74.4 -95.8
Zone 1': _ one 1: _Zone 2: _Zone 3:
Max. Design Pressure, from the specific product approval
system:
Deck:
Type: Plywood
Gauge Thickness: 5/8
Slope: 1-1/2 / 12
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s): Polyglass SA-V & 1
Base Sheet Fastener/Bonding Material:
Self -Adhesive
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: Polyglass Torch Applied
Top Ply Fastener/Bonding Material:
Torch Applied
Surfacing: White Granular Surfaces
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows_ @
_" oc
Zone 1:—"
oc @ Lap, # Rows — @
_" oc
Zone 2:—"
oc @ Lap, # Rows — @
—" oc
Zone 3:--"
oc @ Lap, # Rows_ @
_" oc
Number of Fasteners Per Insulation Board:
Zone 1':—Zone 1:—Zone 2:_Zone 3:_
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..