Loading...
HomeMy WebLinkAboutLetter - Roof Permit Plan ReviewArchitectonic Inc October 10, 2017 St. Lucie County Building Department Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Attn: Roof Permit Plan Review Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 240 W. Aldea Street Dr., St. Lucie County, Florida Manufacturer: CertainTeed Corporation Profiles: Modified Bitumen Roof System, NOA# 14-0529.02 R-21 Code: FBC 2014; Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 20' Maximum Pitch: % /12 Required Design Pressure: Zone1: -38.2 Zone 2: -46.45 Zone3: -69.3 Design Pressure: Zone1: -52.5 Zone 2: -52.5 Zone3: -76.15 Base Sheet: 1 ply All Weather/Empire Base Sheet Fastener: Base sheet shall be lapped 4" and fastened with 11 ga. Annual ring shank nails and approved Tincaps @ 8" o.c., in the lap and three rows staggered in the center of the sheet 8" o.c. for Zone 1 & 2 . Zone 3 attach base sheet using 11 ga. annular ring shank nails and approved tin caps spaced 6" o.c., in a 6" lap and 6" o.c. in three equally spaced staggered rows in the center of the sheet. Membrane: Flintastic GTA Existing Roof Deck: 5/8" CDX Plywood, with 8d ring shank nails @ 6" o.c. thru Zone 1, 4" o.c. perimeter & 6" o.c. Field Zone 2, & 4" o.c. thru out Zone 3 The above approved, as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the Manufacturer's recommendations. OF FC ®�!� p� 'FAF*siab tq'edd R968�9#RAZ a1- 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1