HomeMy WebLinkAboutNOAMIAM.tW MIAMI DARE COUNTI' F PRODUCT CONTROL SECTION 11805 SW 26 Sheet, Room 208 DEPARTMENT OF REGULATORY AND ECONOMC RESOURCES (RER) Miami, Florida 33175 2474 BOARD AND CODE ADMINISTRATION DIVISION I T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA): mu ww_miamidade-eav/econonn CertainTeed Corporation 18 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ)_ This NOA shall not be valid after the expiration date stated below The Miami Dade County Product Control Section On Miami Dade County) and/or the AHJ (m areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AM may immediately revoke, modify, or. suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance; if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone ofthe Florida Building Code. DFscmPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks. LABFUNG! Each unit shall bear a permanent label with the manufacturer`s name or logo, city, state and following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product - TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shalt be done in its cntiray. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #14-0224.03 and consists of pages 1 through 4i. The submitted documentation was reviewed by Alex Tigera. � NOA No.:14-0529.02 _ Fspiration Dates 06/19/18 Approval Date-_ 0124115 Pagel of 47 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: 1275 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description All Weather/Empire Base 39 3/8" x 65' 10'; ASTM D 4601, Type Asphalt coated, fiberglass reinforced Sheet Roll weight: 70 lbs. 11 base sheet. (2 squares) UL Type G2 Flexiglas Base Sheet 39 3/s" x 98'9"; Roll ASTM D 4601, Type Modified Bitumen coated fiberglass weight: 90 lbs: H base sheet. (3 squares) UL Type G2 Flintlastic Base 20 39 3/9 " x 49' 6" RolI ASTM D 6163, Modified Bitumen coated fiberglass weight: 90 lbs. Grade S, Type I base sheet. (1.5 squares) Flintglas Ply Sheet Type IV 39 3/s" x 1647Roll ASTM D 2178, Type Fiberglass, asphalt impregnated ply sheet. weight: 38 lbs. TV (5 squares) UL Type G1 Flintglas Premium Ply Sheet 39 3/s " x 164'7" Roil ASTM D 2178, Type Fiberglass, asphalt impregnated ply Type VI weight: 40 lbs.;: VI sheet. (5 squares) ' UL Type G1 FlintIastic STA 39 3/s" x 32' 10"; Roll ASTM D 6222, Smooth surfaced APP Modified weight: 87 lbs.:: Grade S, Type I Bitumen membrane with non -woven (I square) polyester mat reinforcement for torch application. Flintlastic GTA 39 3/s" x 32' 10' ; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs' Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA-FR 39 3/s " x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs! Grade G, Type I Bitumen membrane with non -woven (I square) ; polyester mat reinforcement for torch application. Flintlastic GMS 39 3/s " x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 94 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. NOA No.: 14-052902 Expiration Date: 06/19/18 Approval Date: 09124/15 Page 2 of 41 Membrane Type: APP Modified Deck Type 1L- Wood, Non -Insulated Deck Deseription_ 19/32" or greater plywood or wood plank System Type E(3): Basc sheet mechanically fastened All General and System Limitations apply. Base Sheet: One ply of All Wtathnffimpm Base Sheet, Yosemite Ventmg Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flinflastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below_ Fastening. Base sheet shall be lapped 4";and fastened with 1 I ga_ annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center ofthe sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Fhntlastic Ultra Poly SMS Base Sheet Glasbase (Optional) Base Sheet, FlexWas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Dace Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 IbsJsq_ or one ply of Black DiamondBase Sheet or Flintlastic Ultra Glass SA self adhered or Fimtlastic STA or Flintlastic APP Base T torch adhered. Membrane: Flintlastic GTA, Flintlastic bTA CoolStar, Flintlashr, GTA-FR or Flmtla=c GTA-FR CoolStar torch adhered to base/ply sheet. Surfacing: Any of the approved surfacing/coating options Iisted in Table 4. (Optional) Maximum Design -52.5 psf_ (See General Limitation 47) Pressure: NOA Noa 14-OS"As` CAAl�AOECOlilY17 Expiration Date_ 06/19/19 Approval date: 891M5 page23 0442 WOOD DECK SYSTEM TL,IMITATtow A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LimnATIONS: l . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the PVT range and at a rate of 20-40 Ibslsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbsJsq. Note: Spot attached systems shall be limited to a ma3imum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is biased on a Minimum Characteristic Force (F7 value of 2751b£, as tested in compliance with Testing Application,Standard TAS 105. If the fastener value, as field-tested, are below 2751bf: insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken1rom Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable 8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roofpressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (Le. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20 3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 140529.02 Expiration Date: 06/19/19 Approval Date: 09/24/15 Page 42 of 42 Florida Building Code Online Page 1 of 2 a o �fttlkttt� BCIS Home Log In User Registration Hot Topics i Submit Surcharge ; Stats & Facts Publications FBC Staff { BCIS Site Map I Links I Search j usi Bnes Professi real*USER:Product Approval c User Regulation - Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL10674-R10 Application Type Revision Code Version 2014 Application Status Approved Comments Archived i Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer RT Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert J.M. Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich, PE F Validation Checklist - Hardcopy Received Certificate of Independence FL10674 R10 COI 2015 01 COI Nieminen pdf Referenced Standard and Year (of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 9/11 /2015 Honda Building Code Online Page 2 of 2 Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 04/22/2015 04/23/2015 04/25/2015 06/23/2015 Summary of Products FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tab�5-tab, aminated, starter and hip &ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL10674 R10 II 2015 04 FINAL ER OC ASPHALT SHINGLES FL10674-R10 odf Verified By: Robert J. M. Nieminen PE - 59166 Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section 5. Created by Independent Third Party: Yes Evaluation Reports FL10674 R10 AE 2015 04 FINAL ER OC ASPHALT SHINGLES FL10674-R10 Ddf Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe StIget, Tallahassee FL 32 ao Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Sooyriaht 2007-2013 gate of Florida :: Privacy Statement :: AScessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: PWFAI ® et�rf ck'ck Credit�AVE http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 9/11 /2015 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 QOTRINITYIERD 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 PHONE: (203) 262-9245 EVALUATION REPORT FAX: (203) 262-9243 vwciib wining Evaluation Report 037940.02.12-115 One Owens Corning Parkway FL10674-R10 Toledo, OH 43659 Date of Issuance: 02/06/2012 SCOPE: Revision 5: 04/22/2015 - This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: t"', Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/22/2015. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Adm inistrator and to the named client CERTIFICATION OF INDEPENDENCE: I. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY l ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.25, R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: EntExamination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation, R2453 Exp. 08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme" are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire' are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire"" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration Designer Color Collection, TruDefinition0akridge', Oakridge" and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire' Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard" HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to V.W =150 mph (V.it =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to V.W = 150 mph (V it =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization #9503 FL10674-R10 Revision 5: 04/22/2015 Page 2 of 6 ter' ��TRINItYJERD 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire' shingles require minimum five (5) nails per shingle. ➢ WeatherGuard• HP shingles require minimum six (6) nails per shingle. ➢ Devonshire"' shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing — Classic® &Supreme: Normal Mansard or Area pan Wind Areas High Wind desvanes y Ara* pars vientos norm*les Areas vientos fuartes z• IB Z' t tr IA) tt• 5•Exposure Exposioi6n 6.2.6 Minimum Nailing — Berkshire®: Seahnt strip La Un de saadm r r Exterior Research and Design, I.I.C. Certificote of Authorization lt9503 Normal Mansard or Area par& Wind Areas High Wind desvenas y Area pars vientos normales Areas vientos foartes 6 51W Exposure Exposiei6n Seahat strip La dr, da id4o v !•t----)• f--fi e 04 b V s----ie r s+�r svt s+�• sW, r a i Z• AVMk roornpament CanWto do Wbo do astalto Evaluation Report 037940.02.12-115 FL10674-R30 Revision 5: 04/221201S Page 3 of 6 6.2.7 Minimum Nailing — Devonshire": 13 V 6. Nails \]'TRINITY IERD Ten 1" S ots d Asphalt Roof Cement 6.2.8 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition' Duration* Designer Color Collection: 6. 4 Nall Pattern . Espoma do 4 davos Su ana tvlith dreg de d 'laws Sriiaigaie a.. Hire" Exposure 5pulg. do expasidda mails S%"UM BqM 14 C&VOS 6140uIgd#irpv*Wn Minimum Nailing — TruDefinition'Oakridge", Oakridge®: 4 Nall Pattern Esquoina coin 4 davos 6EzposlU 5/8' Eyposure da 66/Bptdg Na6 cljvc� ls Erposicon -& s sle pog. 6.2.10 Minimum Nailing Exterior Research and Design, I.I.C. Certificate of Authorization #9503 therGuard® HP: Pattern Wmardand Sfip sbpe winbotm SU Naie ama or" andlop d .,Mott. Abs. opmewes ,77 0. =h Aiade r -7 bv* LK "1- L--Sae Nils 5w uplo;gwe 5*14- de wpo*kin cfawi 54 p6lg. do e4,as[d,% S'Nall Pattern EsWema con 6 davos r ........... 6 6/er Exp"M Nags Clam 5 Sff Exposure E%P0sFd6n-de5618pu[g EVosicbh do G Vepufg. Ole Wds View Fwkm lamilft Nell Lk clowemeliffAlFwAiI.Ion"I I Evaluation Report 037940.02.12-115 FL10674-RI0 Revision 5:04/22/2015 Page 4 of 6 i �TRINITYJERD 6.3 Hip &Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard" HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidge— Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing forwind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge: 6.3.4 6.3.5 Fig. 1 4 E— PrwalftVNnd Direftn p Nais-- p \ 4 \\4 p I 1 p I I 4 I I I I 1 I 1 I I B' Hponue Minimum Nailing— Hip & Ridge with Sealant: Fig. 2 Topmew SileMew Mali Nails 1 1' r Top Laodnated T 1 4.Pie[e 1 I I I I �I I e' SI 1 ul I I i I eht Fig: 2 - HighWrd;Faaenitg Pattern *.hlaW) rim Shingle `nd Discaird 2„ lip Sealant —: - Strip 12". ' Fast hi.itg 5 51"' T. V Exposu re Distance 12" Minimum Nailing— WeatherGuard® HP Hip and Ridge: Fig. C Hip & Ridge Shingle Fastening Top Vlaw Nails Nails T' r t. 1" s' Erposuro 1 17 Exterior Research and Design, LLC. Evaluation Report 037940.02.12-RS Certificate ofAuthorization #9503 FL10674-R10 Revision 5: 04/22/2015 Page 5 of 6 6.3.6 Minimum Nnilina- Prn Frlaa W- A Ri,4a CM dew. Pravaill Wind Direction Sealant Strip A--' 6' Exposure Frt� Exposth Roof Ceteent Standard A16' Fastening Pattern 1 \I fRINI7Y ERD 11 yl I I~1 Seelant 6.3.7 Minimum Nailing—DuraRidge'" Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions fortheir minimum renuiramantc Top Vlew Vua an plan vim swerw I Nei tar Cbu I;��,�!`$�`-{*OMCM^COfI�(1'Q:SIIION�$�,Z.`�•: i� CL.o I I� mI— ilv r� I alo� U IJ'sac IJ J �- 12 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (414) 248-6409; karen.buchmanneul.com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Certificate o/Authorizotion #9503 Evaluation Report 037940.02.12-115 FL10674-R10 Revision 5: 04/22/2015 Page 6 of 6