HomeMy WebLinkAboutLetter - Exterior RenovationJohn M. Foster - Architect
Member - American Institute of Architects - LEED AP
11205 Ridge Ave.
Fort Pierce, Florida 34982
Florida Reg. No. 8511
(772) 370-9464 jmfarchCgmail. com
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, Florida 34982
Exterior Renovation
3103 Kingsley Drive, St. Lucie County, Florida
Permit # SLC-2112-0621
March 10, 2022
RECEIVED
MAR 21 2022
St. Lucie County
Permltting
ATF Permit - Attached, please find my individual verification letters for Weather
Barrier (#651), Wire Lath (#139), Window/Door Attachment (#148) & window &
Door Flashing (#300) as listed on the Inspection sheet for this Permit. I understand
that the Contractor has filed a Notice of Commencement and that St. Lucie County
Building Division Inspectors will re -visit the Site for the Final Inspection.
Also attached is Declaratory Statement 61 G20-1.001 from the Florida Building
Commission which concludes that if the value of the replacement windows in a
"renovated building" do not exceed 30% of the appraised value of the structure,
the replacement windows are not required to meet the provisions of the energy
conservation code ..." This 'Declaratory Statement does not apply to the
requirement that the windows in question must be impact rated.
NFRC Missing Labels Per note from Mike Lunsford, SLC on 03-07-22 "unable
to complete inspection"... no (window) labels ...
During my on -site observations today, I noted that all NFRC labels had been
removed from the newly installed windows. Upon request, the property
owner stated that he always purchased the same type of windows from the
same supplier for his rental properties. Per a forwarded receipt from Home
Depot, the windows in question are branded as "American Craftsman" which
are re -labeled Silver Line Building Products aluminum frame, Low-E
insulated , impact rated units. See attached Florida Product Approval
#14911.5 for "V1 Series/70 Series HVHZ with Design Pressures of +55 (-)
60 PSF, large & small missile impact rating. Table R 301.2.2 shows a
minimum required Design Pressure for a 10 SF opening of +27.6 (-)37.0 in
Zone 5. As noted above, the replacement windows are not required to meet
the energy conservation requirements of the Florida Building Code as long
as they are impact rated & meet or exceed the Design Pressure for this Risk
Category 2, Exposure B, 160 mph wind zone location.
I have reviewed the above noted components and cladding and have
approved their use in this reconstruction. These products provide adequate
resistance to the wind loads &. forces specified in the 7th Edition, 2020
Florida Building Code.
If there are any questions regarding this matter, please contact me as noted
above.
John M. F6,5ter - Architect - AIA
cSIP!E oFP
.,CNN M, R ' P.
G)
N 08Sy '
ARC1�
Property owner's recei merican
Craftsman Series 70, Low-E, impact rated
single -hung windows
SUBTOTAL 714,56":-
SAS TAX —:7 f�
-CARDS M_ IME 0,00
XXXXXY.XXXXXX5372 0EOZ7TA
3 S 42v. 1
AUTM CODE 0�i2�t 7
a) 3 P pead 'des° 4 # fi�d BAID �-,�lI _14
John M. Foster - Architect
Member - American Institute of Architects - LEED AP March 10, 2022
11205 Ridge Ave.
Fort Pierce, Florida 34982
Florida Reg. No. 8511
(772) 370-9464 jmfarch@gmail.com
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, Florida 34982
Exterior Renovations
3103 Kingsley Drive, St. Lucie County, Florida
Permit # SLC-2112-0621
Inspection Type: #651, Weather Barrier
On March 9, 2022, I personally observed "in -place" weather barrier on gable
ends of residence. Installed per Section R703.2; Water -resistive barrier.
To the best of my professional knowledge & belief, this work meets the intent
of the Florida Building Code 2020, Edition 7.
If there are any questions regarding this matter, please contact me as noted
above
John M. ro5ter - AIA
John M. Foster - Architect
Member - American Institute of Architects LEED AP March 10, 2022
11205 Ridge Ave.
Fort Pierce, Florida 34982
Florida Reg. No. 8511
(772) 370-9464 jmfarch@gmail.com
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, Florida 34982
Exterior Renovations
3103 Kingsley Drive, St. Lucie County, Florida
Permit # SLC-2112-0621
Inspection Type: #139, Wire Lath
On March 9, 20225 I personally observed "in -place" wire lath on gable ends of
residence. Installed per Section R703.7.1; Lath.
To the best of my professional knowledge & belief, this work meets the intent
of the Florida Building Code 2020, Edition 7.
If there are any questions regarding this matter, please contact me as noted
above.
John M. 1=o5ter - AIA
7�',S OF FL;
AR0008511 'V
'�„�.RcC1 APG
John M. Foster - Architect
Member - American Institute of Architects - LEED AP March 10, 2022
11205 Ridge Ave.
Fort Pierce, Florida 34982
Florida Reg. No. 8511
(772) 370-9464 jmfarch@gmail.com
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, Florida 34982
Exterior Renovations
3103 Kingsley Drive, St. Lucie County, Florida
Permit # SLC-2112-0621
Inspection Type: #148, Window/door attachment
On March 9, 2022, I personally observed "in -place" window & door
attachment. Installed per Section R609.7.lAnchoring requirements:
Windows - Florida Product Approvals for Silverline (Rebranded at Lowes as
"American Craftsman" ) FL# 14922.5. In -place - 1/4" x 3" ITW Tapcon concrete
screws @ 12" o/c.
Doors - 3' 0" x 6' 8" Masonite Metal Edge Steel Door - FL#7091.1.
To the best of my professional knowledge & belief, this work meets the intent
of the Florida Building Code 2020, Edition 7.
If there are any questions regarding this matter, please contact me as noted
above.
John M. Foster - Architect
Member - American Institute of Architects - LEED AP March 10, 2022
11205 Ridge Ave.
Fort Pierce, Florida 34982
Florida Reg. No. 8511
(772) 370-9464 jmfarch@gmail.com
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, Florida 34982
Exterior Renovations
3103 Kingsley Drive, St. Lucie County, Florida
Permit # SLC-2112-0621
Inspection Type: #300, Window/ door flashing.
On March 9, 2022, I personally observed "in -place" window & door
attachment. Installed per Section R703.4.1.2 In accordance with the flashing
design or method of a registered design professional.
Perimeter of window/door frames seal be sealed to existing construction using a
single part, polyurethane exterior grade sealant.
To the best of my professional knowledge & belief, this work meets the intent
of the Florida Building Code 2020, Edition 7.
If there are any questions regarding this matter, please contact me as noted
above.
John M.