HomeMy WebLinkAboutEvaluation ReportCBUCK Engineering Speaciaity Struc:t rraO Enginesring RECEIVED OCT 26 2017 Permitting Department St, Lucie County, FL Evaluation Report 1" Nail Strip Metal Roof Assembly CBUCK, Inc. Certificate of Authorization #8064 CONCMS FASTENERS ORATTACHWA ARE THE RESPONSIMM OF THE CONiMMROFRECORO Manufacturer: Extreme Metal Fabricators, LLC. 2160 SW Poma Drive ra rn Ci �� �• ty, F� L n s49yn nnvn for Florida Product Approval # FL 17022.5 R5 THESE PLANS AND ALL PROPOSED WORK ARE 81.18JECT TO ANY CO&VIEC110148 REQWRED C1l RUD IPJ OT098 THAT MAY BE NECE9M W Q 91111TO - `gig CQMP6Y kYM1 1P1"WC_�LA QQ Floc Id® ®h611d6n g "a9de 3tiH Ei�Hfit6oni JZW3-q Category: Sub - Category: .s 2 ST. LUCIE COUNTY Product: BUILDING DIVISION Material: REVIEWED FOR CO P CE Panel etnt,o�eo�aS. REVIEWED BY Panel Width: DATE — — PLANS AND PERMIT Panel Seam: MUST BE KEPT ON JOB OR Support: NO INSPECTION WILL BE MADE Prepared by: Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Youry Demosthenes Report No. 16-123-1NS-S6W-ER (Revises 15-217-1NS-S6W-ER) Date: 4 j 18 % 16 Roofing Metal Roofing 1" Nail Strip Roof Panel Steel GU�quuyC 16// Snap -Lock Wood Deck Digitally signed by James L. Buckner, P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule 61G15-23.\�`kJII11111J'. All * ' No 31242 w= i0,q1' STATE OF '•.FLORIOP,. Contents: Evaluation Report Pages 1— 7 2016.04.19 11:32:32-04'00' CBUCK, Inc. - Palm Beach County, Florida Phone: (561) 491-9927 • Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net Mail Address: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL 33062 Vl­r CBUCK Engineering SpPciaity Structural Engiriemering Manufacturer: Extreme Metal Fabricators, LLC. _proauct_Name: j."_i_uaii.-trip Product Category: Roofing Product Sub -Category Metal Roofing FL #: FL 17022.5 R5 Date: 4 / 18 / 16 Report No.: 16-123-INS-S6W-ER Page 2 of 7 CBUCK, Inc. Certificate of Authorization #8064 ;rr jnii rre�_AftathnA:-S-tatp:Prrnq!rrt--Amryrntm!-Ri11n;E-'kL-9fl-JR:00S:/:1):Hj Product/System 1" Nail Strip Roof Panel, 26 Gauge steel, 16" wide panel mechanically attached to Description: Wood Deck Product Assembly as Refer to Page 4 of this report for product assembly components/materiais & 1. Roof Panel 2. Fasteners 3. Adhesive (select system) 4. Underlayment 5. Insulation (Optional) �rrnnr►�; ��r�n; Wood Deck (Design of support system is outside the scope of this evaluation.) Description: S 15/32" or greater plywood, 4 or Wood Plank (min. specifir gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: Designs Uplift Pressure (A.CiD" Refer to Table 6 (Refer to "I able A" attachment details herein) CBUCK Engineering FL #: FL 17022.5 IRS Date: 4 / 18 / 16 Report No.: 16-123-1NS-S6W-ER Page 3 of 7 Spitelaity Structural Engineaerinq CBUCK, Inc. Certificate of Authorization #8064 Performance Standards: The product described herein has demonstrated compliance with: ® UL580-06 — Test for Uplift Resistance of Roof Assemblies • UL 1897-04 — Uplift test for roof covering systems �coUe iuM-p-iiance: 7 in iJrUUlu cL UeScriueu nereirl fldve de r-ri u r-1 SA r-d- Led corli(Jlldr c-e WILfl Line P-t! 10-rrf1dnce standards listed above as referenced in the current Florida Building Code. Evaluation Report This product evaluation is limited to compliance with the structural requirements Scope: of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Lirril-talions and • This evaluation report for "Optional Statewide Approval" contains technical Conditions of Use: documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". Option for application outside "Limitations and Conditions of Use" RIM VJ.IJLV-J.VUJi.1.iiCJ a11UVV3 ciigli:cci iiig allaIY313 iur Prvjcii SpcGiTlG appruvai by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. e This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to rmmnly With Flnrirla nrnrhirt annrrnial riila (PArl 61G7Q-3- Thic e%/;;h atinn rannrt is part of the Florida Building Commission approvai for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. e Deck shall be in compliance with applicable building code. e Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in \�.c: vrd\= : ?Fth ell c T�[vrida n;::!^ae _ r nila nu T�: lc :.7ZI �. V . Mile : v\A114..b --- - 411 manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824). CBUCK Engineering Specialty Structural Engineering Components/Materials (by Manufacturer): Roof Panel: Material: Thickness: Panel Widths: nib-HeiIP"lii,: Yield Strength: Corrosion Resistance: Fastener: i yNe: Size: Corrosion Resistance Standard: FL #: FL 17022.5 R5 Date: 4 / 18 / 16 Report No.: 16-123-1NS-S6W-ER Page 4 of 7 CBUCK, Inc. Certificate of Authorization #8064 1" Nail Strip Steel 26 Gauge (min.) 16" (max.) CoveraHe -1- 50 ksi min. In compliance with FBC Section 1507.4.3: ASTM A792 coated, or ® ASTM A653 G90 galvanized steel _,-r - rancd-K-a-lledu VVUUU JC:rew #10 x 1" (min.) Per FBC Section 1506.6 and 1507.4.4 Per ANSI/ASME B18.6.1 Seam Adhesive/Sealant: (Select Systems) Product NarnP: Rnstik 91.5TM C;hPm-Chalk Type: One component, poiyurethane adhesive Application Size: 3/16" continuous bead Application Location: Along base of male rib vertical flange at each panel seam. (Refer to Table "A" and drawing Pg 6-7) CnmnnnPntc/Materials: 11 ndPrlavmant! -(by uinersj: Materiai and appiication shall be in compliance with FBC Section 1507.4.5.i and 1507.4.5.2, applicable codes and in accordance with manufacturer's recommendations. Insulation (Optional): Type: Thirknocc- Properties: Density: Or Compressive Strength: Rigid Insulation Board 'A" (may.) 2.25 pcf (Ibs/ft3) min. 20 psi min. Insulation Notes: Rigid Insulation shall meet minimum density OR compressive strength. IMCIII9�Inn �i1�ii rnY,�ni�i �..i+h mar cor+inn 1 r-nQ %A/hen inel Ilo+inn ie - IIIJUIU I.IV11 JI 1{A 11 VV1111JIr YY 11,11 1 V�r J�. •. 1,IV11 1JVV• VY IIVII ...'111V 111V 11 IJ incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". _ J FL #: FL 17022.5 R5 Date: 4 / 18 / 16 CBUCK Engineering Page Report No.: 5 -17 INS-S6W-ER ISpL=clalty Structural Enc;Ilne%L=rinq CBUCK, Inc. Certificate of Authorization #8064 Installation: Installation Method: (Refer to "TABLE A" below and drawings at the end of this evaluation report.) Referenced Data: ■ Fastener Spacing: Rofnr to "TAQ1 9: A" Roln�9i :(ator _the.teneth=of_the;paneil ■ Rib Interlock: Snap -Lock (Panel ribs shall be fully engaged to form an integral snap -lock.) ■ Seam Adhesive: Refer to Table "A" & Drawing Page 6. (Apply continuously along base of male rib vertical flange at each panel seam.) ■ Minimum fastPnPr nPnPtration thru bottom of sunnort. -4/1 h". • For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" ALLOWABLE LOADS I IMj6OpEfIIN sJa 1 I METHOD 2 � Design Pressure (ASD)*: 86 PSFMW 97.25 PSF Fastener Spacing: 6" o.e. 6" o.c. Seam Adhesive: Nvt regaired 3/16" continuous bead (Refer to pg. 6-7) T Allowable design pressure(s) for allowable stress design ("ASD) with a margin of safety of 2 Install the 1" Nail Strip roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. - -F,,,, Fli 1. UL 580-06 & UL 1897-04 — Uplift Test ,� By Architectural Testing, Inc. - West Palm Beach, FL (FBC Organization #TST ID: 1527) Report No. D8133.01-4S0-18, Date: 06/30/15, Specimens #1 & #2 2. Quality Assurance Keystone Certifications, Inc. (FBC Organization iD# QUA 1824) E% a[,71 3. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) CBUCK Engineering FL #: FL 17022.5 R5 Date: 4 / 18 / 16 Report No.: 16-123-1NS-S6W-ER Page 6 of 7 SpE&clalfiy Structural Encgiriemering CBUCK, Inc. Certificate of Authorization #8064 Installation Method Extreme Metal Fabricators, LLC. I Mail 15trin On r ai,®P heel► Rnnf Panel attarhpd to Wnnd nark Drawings 3/4" f_ Panel Profile 16" o.c. I� Deck: -15/32" or greater Plywood, or - Wood plank Integral Snap Lock For METHOD 2: Apply 3116" Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1" Min. per Table "A" Pancake Head uvood Screw Typical Assembly Profile View (Typical Fastening Pattern Across Width) V CBUCK Engineering FL #: FL 17022.5 R5 Date: 4 / 18 / 16 Report No.: 16-123-1NS-S6W-ER Page 7 of 7 SlaeK--lalfi j Structural EnQ11ne2erinq CBUCK, Inc. Certificate of Authorization #8064 Installation Method Extreme Metal Fabricators, LLC. 7" Mail .trip On sauap S#ppll Roof Panpi attachpfl to Wnnd lipck Fastener #10 x 1" Min. per Table "A" Pancake Head Wood Screw 1" Nail Strip Roof Panel ✓ 0 S Optional: Rigid Insulation Thickness 3" Maximum Seam Adhesive Application: Deck: For Method 2 15/32" or greater Plywood, or Apply 3/16" Bead Bostik 915TM Sealant - Wood plank Continuous Along Male Rib Vertical Flange (Refer to Table "A") Twiiai 1.vvi AQSOOMCIiy ME (Optional) Rigid Insulation Board per Page 4 of this report TABLE "A" ALLOWABLE LOAD'S , 01111'JMY I rVIETHOD 2 vehir,ii Me3Suitl kASUj-: - bD rJl - 7/'.2-5 Par Fastener Spacing: 6" o c ., 6" o.c. Seam Adhesive: N Not r quired 3/16" Continuous Bead *Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1.