HomeMy WebLinkAboutAPPROVED Green Pg 34" MIN. FROM WATER I POOL LIGHT U.L. LEVEL TO TOP OF LENS APPROVED LOW VOTLAGE NICHELE.$S--- LIGHT l 1 %"' PVC CONDUIT POOL STEEL .I FROM 12V TRANSFORMER LIGHT NICHE DETAIL N.T.S. ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE EXISTING SERVICE AND PANEL HAS ENOUGH CAPACITY TO ACCOMMODATE THE ADDED POOL EQUIPMENT LOAD PER NEC 220.82" NOTE: BASED ON INFORMATION PROVIDED TO THIS OFFICE, THE EXISTING SERVICE EXISTING PANEL IS ADEQUATE FOR THE PROPOSED ADDITIONAL POOL EQUIPMENT LOAD 2P BOA BREAKER FEEDING POOL EXISTING I 0 METER FPL '' PVC CONDUIT WI 2.;A HOT. 1 #8 GRND_ 1 #B NEUTRAL GFCI 6' TO 20' FROM WATER 2 #12, 1 #12 GRND PANEL PUMP (1) — 2 P-20AGFCI LIGHT -CHLORINATOR (1)—lP-15A HEATER (1) —2P — 50A GFCI TRANSFORMER 120-12V 300 W/ TRANSF POOL PUMP 3 912, 1 #12 GRND- GFCI PROTECTED %" PVC SALT CHLORINATOR 2 #12, 1 #12 GRND. K" PVC HEAT PUMP 2 46, 1 #10 GRND 3/<" PVC f 48" MIN. ,k - POOL j DECK LEVELrli JUNCTION BOX Y � 4^ 2 a 1" NON -CORROSIVE 1, IN POOL AREA GROUND ALL BOXES, RAILS, LIGHT. MOTOR ECT WITH 3 '—CONDUIT 9 BARE COPPER WIRE 2 ALL ELECTRICLA TO COMPLY WITH 2O17 NATIONAL ELECTRICAL CODE ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION 3. #12 THHN CU %" MIN CONDUIT FOR POOL LIGHT(S)- 4. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 6B0-22(B)- - (2) 24 W L E D NICHELESS LIGHTS (POOL) 5 LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL - BY OTHERS 6 PROVIDE G.F. C.I.OUTLET 6' MIN -20' MAX FROM WATER's EDGE. ELECTRICAL RISER DIAGRAM N.T.S. DRAFTED BY: G.S.M. #B BARE COPPER WIRE FOR 360° WITH 4 JUMPERS TO BE 18" TO 24" WATER LINE FROM WATERS EDGE K--..POTENTIAL BONDING GRID DETAILN PER FLORIDA BUILDING CODE ADAPTION OF N.E.C. 2017 SEC 680.21 A Custom Pool Desianed GREEN, SERID & ALLISON 2373 DYER RD PORT ST LUCIE, FL 34952 0ESI N"EH MONIKA POLAK TO POOL FQUIPMENT ROM- PROVIDE CONTINOUS SINGLE 98 COOPER BONDED IN FOUR POINTS (360°) AROUND 1� POOL B SPA AS PER N.E.C. 2017 AR7. 680.26181 E 10 NOTE: BOND WIRE TO BE SECURED TO STEEL WITH APPROVED CLAMP. TO BE ENCASED IN DECK SLAB OR CONCRETE BOX PROVIDING MIN. 3" OF COVER AROUND CLAMP POOL BOND SCHEMATIC N.T.S. llv For: ELECTRICAL CODE and NOTES: National Electrical Code (NEC), NFPA 70 - 2017 shall specifically govern, including Article 680 Swimming Pools, Fountains, and Similar Installations Article 430.32 Continuous -Duty Motors. Each motor used in continues duty application shall be protected against overload Article 680.6 Grounding. Electrical equipment shall be grounded in accordance with Parts V, VI and VII of Article 250 and connected by wiring methods of Chapter 3, except as modified by this Article. The following equipment shall be grounded: (1) Through -wall lighting assemblies and underwater luminaires, other than those low -voltage lighting products listed for the application without a grounding conductor (2) All electrical equipment located within 1.5 m (5 ft) of the inside wall of the specified body of water (3) All electrical equipment associated with the recirculating system of the specified body of water (4) Junction boxes (5) Transformer and power supply enclosures (6) Ground -fault circuit interrupters (7) Panelboards that are not part of the service equipment and that supply any electrical equipment associated with the body of water Article 680.9 Overhead Conductor Clearances. Overhead conductors shall meet the clearance requirements in this section. Where a minimum clearance from the water level is given, the measurement shall be taken from the maximum water level of the specified body of water. (A) Power. With respect to service -drop conductors, overhead service conductors, and open overhead wiring, swimming pool and similar installations shall comply with the minimum clearances given in Table 680.9(A) and illustrated in Figure 680.9(A). (B) Communications Systems. Communications, radio, and television coaxial cables within the scope of Articles 800 to 820 shall be permitted at a height of not less than 3.0 m (10 ft) above swimming and wading pools, diving structures, and observation stands, towers, or platforms. (C) Network -Powered Broadband Communications Systems. The minimum clearances for overhead network -powered broadband communications systems conductors from pools or fountains shall comply with the provisions in Table 680.9(A) for conductors operating at 0 to 750 volts to ground. Article 680.10 Electric Pool Water Heaters. All electric pool water heaters shall have the heating elements subdivided into loads not exceeding 48 amperes and protected at not over 60 amperes. The ampacity of the branch -circuit conductors and the rating or setting of overcurrent protective devices shall not be less than 125 percent of the total nameplate -rated load. Article 680.11 Underground Wiring Location. Underground wiring shall be permitted where installed in rigid metal conduit, intermediate metal conduit, rigid polyvinyl chloride conduit, reinforced thermosetting resin conduit, or Type MC cable, suitable for the conditions subject to that location. Underground wiring shall not be permitted under the pool unless this wiring is necessary to supply pool equipment permitted by this article. Minimum cover depths shall be as given in Table 300.5. Article 680.22 Lighting, Receptacles, and Equipment. (A) Receptacles. (1) Required Receptacle, Location. Where a permanently installed pool is installed, no fewer than one 125- volt,15- or 20-ampere receptacle on a general-purpose branch circuit shall be located not less than 1.83 m (6 ft) from, and not more than 6.0 m (20 ft) from, the inside wall of the pool. This receptacle shall be located not more than 2.0 m (6 ft 6 in.) above the floor, platform, or grade level serving the pool. (2) Circulation and Sanitation System, Location. Receptacles that provide power for water -pump motors or for other loads directly related to the circulation and sanitation system shall be located at least 1.83 m (6 ft) from the inside walls of the pool. These receptacles shall have GFCI protection and be of the grounding type. (3) Other Receptacles, Location. Other receptacles shall be not less than 1.83 m (6 ft) from the inside walls of a pool. (4) GFCI Protection. All 15- and 20-ampere, single-phase, 125-volt receptacles located within 6.0 m (20 ft) of the inside walls of a pool shall be protected by a ground -fault circuit interrupter. WAYNE MARKFUIM BENNETT P.E. M7216 MARKHAM SERVICES. INC (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH FL 34957-7212 1 0J111i (954)818-38251 Wayne@wmb-pe.com IF THERE IS A DIGITAL SIGNATURE ON THE FRONTIFIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET IF SIGNED DIGITALLY ABOVE PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED I E-1 SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES ��. tit �p,PtKHAIy � ■, �:• h10 57216 Q'• STATE OF : d z r �