HomeMy WebLinkAboutAPPROVED Green Pg 34" MIN. FROM WATER I POOL LIGHT U.L.
LEVEL TO TOP OF LENS APPROVED
LOW VOTLAGE NICHELE.$S---
LIGHT
l 1 %"' PVC CONDUIT
POOL STEEL .I FROM 12V TRANSFORMER
LIGHT NICHE DETAIL
N.T.S.
ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE EXISTING SERVICE AND PANEL HAS
ENOUGH CAPACITY TO ACCOMMODATE THE ADDED POOL EQUIPMENT LOAD PER NEC 220.82"
NOTE:
BASED ON INFORMATION PROVIDED TO THIS OFFICE, THE EXISTING SERVICE
EXISTING PANEL IS ADEQUATE FOR THE PROPOSED ADDITIONAL POOL EQUIPMENT LOAD
2P BOA BREAKER
FEEDING POOL
EXISTING I 0
METER
FPL
'' PVC CONDUIT WI 2.;A HOT.
1 #8 GRND_ 1 #B NEUTRAL
GFCI 6' TO 20'
FROM WATER
2 #12,
1 #12
GRND
PANEL
PUMP (1) — 2 P-20AGFCI
LIGHT -CHLORINATOR (1)—lP-15A
HEATER (1) —2P — 50A GFCI
TRANSFORMER 120-12V 300 W/ TRANSF
POOL PUMP 3 912, 1 #12 GRND- GFCI PROTECTED %" PVC
SALT CHLORINATOR 2 #12, 1 #12 GRND. K" PVC
HEAT PUMP 2 46, 1 #10 GRND 3/<" PVC
f 48" MIN. ,k -
POOL j
DECK
LEVELrli
JUNCTION BOX
Y �
4^
2
a 1" NON -CORROSIVE
1, IN POOL AREA GROUND ALL BOXES, RAILS, LIGHT. MOTOR ECT WITH
3 '—CONDUIT
9 BARE COPPER WIRE
2 ALL ELECTRICLA TO COMPLY WITH 2O17 NATIONAL ELECTRICAL
CODE ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY
AT POINT OF CONNECTION
3. #12 THHN CU %" MIN CONDUIT FOR POOL LIGHT(S)-
4. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 6B0-22(B)-
- (2) 24 W L E D NICHELESS LIGHTS (POOL)
5 LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL - BY OTHERS
6 PROVIDE G.F. C.I.OUTLET 6' MIN -20' MAX FROM WATER's EDGE.
ELECTRICAL RISER DIAGRAM
N.T.S.
DRAFTED BY: G.S.M.
#B BARE COPPER WIRE FOR 360°
WITH 4 JUMPERS TO BE 18" TO 24"
WATER LINE FROM WATERS EDGE
K--..POTENTIAL
BONDING GRID DETAILN
PER FLORIDA BUILDING CODE
ADAPTION OF N.E.C. 2017 SEC 680.21
A Custom Pool Desianed
GREEN, SERID & ALLISON
2373 DYER RD
PORT ST LUCIE, FL 34952
0ESI N"EH MONIKA POLAK
TO POOL FQUIPMENT
ROM- PROVIDE CONTINOUS
SINGLE 98 COOPER BONDED
IN FOUR POINTS (360°) AROUND
1� POOL B SPA AS PER N.E.C.
2017 AR7. 680.26181 E 10
NOTE: BOND WIRE TO BE SECURED
TO STEEL WITH APPROVED CLAMP.
TO BE ENCASED IN DECK SLAB OR CONCRETE BOX
PROVIDING MIN.
3" OF COVER AROUND CLAMP
POOL BOND SCHEMATIC
N.T.S.
llv For:
ELECTRICAL CODE and NOTES:
National Electrical Code (NEC), NFPA 70 - 2017 shall specifically govern, including Article 680
Swimming Pools, Fountains, and Similar Installations
Article 430.32 Continuous -Duty Motors. Each motor used in continues duty application shall
be protected against overload
Article 680.6 Grounding. Electrical equipment shall be grounded in accordance with Parts V, VI
and VII of Article 250 and connected by wiring methods of Chapter 3, except as modified by this
Article. The following equipment shall be grounded: (1) Through -wall lighting assemblies and
underwater luminaires, other than those low -voltage lighting products listed for the application
without a grounding conductor (2) All electrical equipment located within 1.5 m (5 ft) of the inside
wall of the specified body of water (3) All electrical equipment associated with the recirculating
system of the specified body of water (4) Junction boxes (5) Transformer and power supply
enclosures (6) Ground -fault circuit interrupters (7) Panelboards that are not part of the service
equipment and that supply any electrical equipment associated with the body of water
Article 680.9 Overhead Conductor Clearances. Overhead conductors shall meet the
clearance requirements in this section. Where a minimum clearance from the water level is given,
the measurement shall be taken from the maximum water level of the specified body of water. (A)
Power. With respect to service -drop conductors, overhead service conductors, and open
overhead wiring, swimming pool and similar installations shall comply with the minimum
clearances given in Table 680.9(A) and illustrated in Figure 680.9(A). (B) Communications
Systems. Communications, radio, and television coaxial cables within the scope of Articles 800
to 820 shall be permitted at a height of not less than 3.0 m (10 ft) above swimming and wading
pools, diving structures, and observation stands, towers, or platforms. (C) Network -Powered
Broadband Communications Systems. The minimum clearances for overhead network -powered
broadband communications systems conductors from pools or fountains shall comply with the
provisions in Table 680.9(A) for conductors operating at 0 to 750 volts to ground.
Article 680.10 Electric Pool Water Heaters. All electric pool water heaters shall have the
heating elements subdivided into loads not exceeding 48 amperes and protected at not over
60 amperes. The ampacity of the branch -circuit conductors and the rating or setting of
overcurrent protective devices shall not be less than 125 percent of the total nameplate -rated
load.
Article 680.11 Underground Wiring Location. Underground wiring shall be permitted where
installed in rigid metal conduit, intermediate metal conduit, rigid polyvinyl chloride conduit,
reinforced thermosetting resin conduit, or Type MC cable, suitable for the conditions subject to
that location. Underground wiring shall not be permitted under the pool unless this wiring is
necessary to supply pool equipment permitted by this article. Minimum cover depths shall be as
given in Table 300.5.
Article 680.22 Lighting, Receptacles, and Equipment. (A) Receptacles. (1) Required
Receptacle, Location. Where a permanently installed pool is installed, no fewer than one 125-
volt,15- or 20-ampere receptacle on a general-purpose branch circuit shall be located not less
than 1.83 m (6 ft) from, and not more than 6.0 m (20 ft) from, the inside wall of the pool. This
receptacle shall be located not more than 2.0 m (6 ft 6 in.) above the floor, platform, or grade
level serving the pool. (2) Circulation and Sanitation System, Location. Receptacles that provide
power for water -pump motors or for other loads directly related to the circulation and sanitation
system shall be located at least 1.83 m (6 ft) from the inside walls of the pool. These receptacles
shall have GFCI protection and be of the grounding type. (3) Other Receptacles, Location. Other
receptacles shall be not less than 1.83 m (6 ft) from the inside walls of a pool. (4) GFCI
Protection. All 15- and 20-ampere, single-phase, 125-volt receptacles located within 6.0 m (20 ft)
of the inside walls of a pool shall be protected by a ground -fault circuit interrupter.
WAYNE MARKFUIM BENNETT P.E. M7216
MARKHAM SERVICES. INC (CA 33018)
1820 NE JENSEN BEACH BLVD #685
JENSEN BEACH FL 34957-7212 1 0J111i
(954)818-38251 Wayne@wmb-pe.com
IF THERE IS A DIGITAL SIGNATURE ON THE FRONTIFIRST PAGE OF THIS FILE, THIS SHEET
IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL
SIGNATURE ON THIS SHEET
IF SIGNED DIGITALLY ABOVE PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED
I E-1 SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES
��. tit �p,PtKHAIy � ■,
�:• h10 57216
Q'• STATE OF : d z
r �