HomeMy WebLinkAboutAPPROVED REVISION 3 Charles - Energy - Revised 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 73/11/2022 9:38 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
Charles Residence
Charles Residence
Street:
City, State, Zip: Fort Pierce , FL , 34945
18900 Schumann Road
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Detached
1
No
2700
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
Sgl, U=1.08 165.33 ft²
SHGC=0.29
Sgl, U=1.06 128.00 ft²
SHGC=0.28
N/A f t ²
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2700.00 ft²
R=f t ²
R=f t ²
10. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 2832.50 ft²
b. N/A R=f t ²
c. N/A R=f t ²
11. Ceiling Types
a. Roof Deck (Unvented)R=20.0 2700.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Pantry
13. Cooling systems
14. Heating systems
15. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:3.064 ft.
Area Weighted Average SHGC:0.286
Description Area
Insulation Area
Insulation Area
Insulation Area
16. Credits CF, Pstat
2
(293.3 sqft.)
(2832.5 sqft.)
(2700.0 sqft.)
(2700.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
41.0 SEER:16.00
Efficiency
k B t u / h r Efficiency
34.0 COP:1.00
f t ² R
6 85
EF: 0.950
8. Skylights
c. U-Factor:(AVG)
S H G C ( A V G ) :
N/A
N/A
f t ²
Area
Glass/Floor Area: 0.109
Total Proposed Modified Loads:
Total Baseline Loads:
78.38
81.76 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2020
3-11-2022
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
1
Charles Residence
Charles Residence
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
2700
2
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34945
Fort Pierce ,
St. Lucie
18900 Schumann Road
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2700 27000
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 M Bath 166 1660 No 1 Yes Yes1 Yes
2 Toilet 40 400 No 0 Yes Yes1 Yes
3 M WIC 2 84 840 No 1 Yes Yes1 Yes
4 M WIC 1 80 800 No 1 Yes Yes1 Yes
5 M Bedroom 350 3500 No 2 1 Yes Yes1 Yes
6 Den 120 1200 No 2 Yes Yes1 Yes
7 Foyer 81 810 No 0 Yes Yes1 Yes
8 Bedroom 3 144 1440 No 2 1 Yes Yes1 Yes
9 WIC 3 72 720 No 1 Yes Yes1 Yes
10 Bath 3 78 780 No 0 Yes Yes1 Yes
11 Pantry 207 2070 No 1 Yes Yes1 Yes
12 Bath 2 64 640 No 0 Yes Yes1 Yes
13 Laundry 128 1280 No 0 Yes Yes1 Yes
14 Hall 1 70 700 No 0 Yes Yes1 Yes
15 Living Room 564 5640 No 2 Yes Yes1 Yes
16 Utility 99 990 No 0 Yes Yes1 Yes
17 Kitchen 341 3410 Yes 2 Yes Yes1 Yes
18 Hall 2 12 120 No 0 Yes Yes1 No
3/11/2022 9:38 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 166 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -25 ft M Bath
2 40 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -13 ft Toilet
3 84 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -3 ft M WIC 2
4 80 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -8 ft M WIC 1
5 350 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -20 ft M Bedroom
6 120 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -13 ft Den
7 81 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -9 ft Foyer
8 144 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -15 ft Bedroom 3
9 72 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -27 ft WIC 3
10 78 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -13 ft Bath 3
11 207 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -23 ft Pantry
12 64 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -8 ft Bath 2
13 128 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -32 ft Laundry
14 70 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -9 ft Hall 1
15 564 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -24.2 ft Living Room
16 99 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -27 ft Utility
17 341 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -14 ft Kitchen
18 12 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 2
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Metal 2925 ft² Light 0.6 20 22.62______ No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 2700 ft² N N0
3/11/2022 9:38 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented) 0 166 ft² 0.1 Wood______ M Bath Blown
2 Under Attic (Unvented) 0 40 ft² 0.1 Wood______ Toilet Blown
3 Under Attic (Unvented) 0 84 ft² 0.1 Wood______ M WIC 2 Blown
4 Under Attic (Unvented) 0 80 ft² 0.1 Wood______ M WIC 1 Blown
5 Under Attic (Unvented) 0 350 ft² 0.1 Wood______ M Bedroom Blown
6 Under Attic (Unvented) 0 120 ft² 0.1 Wood______ Den Blown
7 Under Attic (Unvented) 0 81 ft² 0.1 Wood______ Foyer Blown
8 Under Attic (Unvented) 0 144 ft² 0.1 Wood______ Bedroom 3 Blown
9 Under Attic (Unvented) 0 72 ft² 0.1 Wood______ WIC 3 Blown
10 Under Attic (Unvented) 0 78 ft² 0.1 Wood______ Bath 3 Blown
11 Under Attic (Unvented) 0 207 ft² 0.1 Wood______ Pantry Blown
12 Under Attic (Unvented) 0 64 ft² 0.1 Wood______ Bath 2 Blown
13 Under Attic (Unvented) 0 128 ft² 0.1 Wood______ Laundry Blown
14 Under Attic (Unvented) 0 70 ft² 0.1 Wood______ Hall 1 Blown
15 Under Attic (Unvented) 0 564 ft² 0.1 Wood______ Living Room Blown
16 Under Attic (Unvented) 0 99 ft² 0.1 Wood______ Utility Blown
17 Under Attic (Unvented) 0 341 ft² 0.1 Wood______ Kitchen Blown
18 Under Attic (Unvented) 0 12 ft² 0.1 Wood______ Hall 2 Blown
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0M Bath 00014 10S Concrete Block - Int Insul 0.40Exterior 140.0 ft² ____
2 4.1 0M Bath 00011 10W Concrete Block - Int Insul 0.40Exterior 110.0 ft² ____
3 4.1 0Toilet 0008 10E Concrete Block - Int Insul 0.40Exterior 80.0 ft² ____
4 4.1 0Toilet 0005 10S Concrete Block - Int Insul 0.40Exterior 50.0 ft² ____
5 4.1 0M WIC 2 0003 10S Concrete Block - Int Insul 0.40Exterior 30.0 ft² ____
6 4.1 0M WIC 1 0008 10W Concrete Block - Int Insul 0.40Exterior 80.0 ft² ____
7 4.1 0M Bedroom 00020 10W Concrete Block - Int Insul 0.40Exterior 200.0 ft² ____
8 4.1 0Den 0003 10E Concrete Block - Int Insul 0.40Exterior 30.0 ft² ____
9 4.1 0Den 00010 10S Concrete Block - Int Insul 0.40Exterior 100.0 ft² ____
10 4.1 0Foyer 0009 10S Concrete Block - Int Insul 0.40Exterior 90.0 ft² ____
11 4.1 0Bedroom 3 00012 10S Concrete Block - Int Insul 0.40Exterior 120.0 ft² ____
12 4.1 0Bedroom 3 0003 10W Concrete Block - Int Insul 0.40Exterior 30.0 ft² ____
13 4.1 0WIC 3 00012 10E Concrete Block - Int Insul 0.40Exterior 120.0 ft² ____
14 4.1 0WIC 3 0006 10S Concrete Block - Int Insul 0.40Exterior 60.0 ft² ____
15 4.1 0WIC 3 0009 10W Concrete Block - Int Insul 0.40Exterior 90.0 ft² ____
16 4.1 0Bath 3 00013 10E Concrete Block - Int Insul 0.40Exterior 130.0 ft² ____
17 4.1 0Pantry 00023 10E Concrete Block - Int Insul 0.40Exterior 230.0 ft² ____
18 4.1 0Bath 2 0008 10W Concrete Block - Int Insul 0.40Exterior 80.0 ft² ____
19 4.1 0Laundry 00013 10N Concrete Block - Int Insul 0.40Exterior 130.0 ft² ____
20 4.1 0Laundry 0008 10E Concrete Block - Int Insul 0.40Exterior 80.0 ft² ____
21 4.1 0Laundry 00011 10W Concrete Block - Int Insul 0.40Exterior 110.0 ft² ____
22 4.1 0Hall 1 0003 10N Concrete Block - Int Insul 0.40Exterior 30.0 ft² ____
3/11/2022 9:38 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
23 4.1 0Hall 1 0006 10E Concrete Block - Int Insul 0.40Exterior 60.0 ft² ____
24 4.1 0Living Room 00017 10N Concrete Block - Int Insul 0.40Exterior 170.0 ft² ____
25 4.1 0Living Room 0037 10NW Concrete Block - Int Insul 0.40Exterior 72.5 ft² ____
26 4.1 0Utility 0009 10N Concrete Block - Int Insul 0.40Exterior 90.0 ft² ____
27 4.1 0Utility 00011 10E Concrete Block - Int Insul 0.40Exterior 110.0 ft² ____
28 4.1 0Utility 0007 10W Concrete Block - Int Insul 0.40Exterior 70.0 ft² ____
29 4.1 0Kitchen 00011 10N Concrete Block - Int Insul 0.40Exterior 110.0 ft² ____
30 4.1 0Kitchen 0003 10W Concrete Block - Int Insul 0.40Exterior 30.0 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 W Low-E Single 1.08 0.29 30.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes7 Y
2 S Low-E Single 1.08 0.29 15.0 ft² 6 ft 0 in 1 ft 4 in NoneVinyl None______ Yes9 Y
3 S Low-E Single 1.08 0.29 24.0 ft² 10 ft 0 in 1 ft 4 in NoneVinyl None______ Yes10 Y
4 S Low-E Single 1.08 0.29 15.0 ft² 6 ft 0 in 1 ft 4 in NoneVinyl None______ Yes11 Y
5 E Low-E Single 1.08 0.29 9.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes16 Y
6 N Low-E Single 1.08 0.29 13.5 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes19 Y
7 E Low-E Single 1.08 0.29 22.7 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes23 Y
8 N Low-E Single 1.06 0.28 128.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes24 Y
9 NW Low-E Single 1.08 0.29 22.7 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes25 Y
10 N Low-E Single 1.08 0.29 13.5 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes29 Y
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
2250 5123.44.000317Wholehouse .0987231.75Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/ COP:1 34 kBtu/hr ______ sys#1None 1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/ SEER: 16 41 kBtu/hr c f m 0.7______ sys#1Split 1 Singl
3/11/2022 9:38 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.95 50 gal 60.9 gal 120 deg None______ None Laundry
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 85 ft² Attic 20 ft² Prop. Leak Free Pantry 81.0 cfm 0.03 0.50______ 1 1 --- cfm
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 M Bath
Default(8 lbs/sq.ft. f t ² f t 0.3 Toilet
Default(8 lbs/sq.ft. f t ² f t 0.3 M WIC 2
Default(8 lbs/sq.ft. f t ² f t 0.3 M WIC 1
Default(8 lbs/sq.ft. f t ² f t 0.3 M Bedroom
Default(8 lbs/sq.ft. f t ² f t 0.3 Den
Default(8 lbs/sq.ft. f t ² f t 0.3 Foyer
Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 3
Default(8 lbs/sq.ft. f t ² f t 0.3 WIC 3
Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 3
Default(8 lbs/sq.ft. f t ² f t 0.3 Pantry
Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry
Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 1
Default(8 lbs/sq.ft. f t ² f t 0.3 Living Room
Default(8 lbs/sq.ft. f t ² f t 0.3 Utility
3/11/2022 9:38 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen
Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 2
3/11/2022 9:38 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
Charles Residence
Charles Residence
Street:
City, State, Zip: Fort Pierce , FL , 34945
18900 Schumann Road
Permit Number:
Design Location: FL, Fort Pierce CHECKAIR BARRIER CRITERIA
A continuous air barrier shall be installed in the building envelope.
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
the insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
The junction of the top plate and the top of exterior walls shall be
sealed.
Knee walls shall be sealed.
The space between window/door jambs and framing, and
skylights and framing shall be sealed.
Rim joists shall include the air barrier.
The air barrier shall be installed at any exposed edge of
insulation.
Exposed earth in unvented crawl spaces shall be covered with
a Class I vapor retarder with overlapping joints taped.
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities
Shafts, penetrations
Crawl space walls
Floors
(including
above-garage
and cantilevered
floors)
Rim joists
Windows, skylights
Walls
Ceiling/attic
General
COMPONENT
Garage separation
Recessed lighting
Plumbing and wiring
S h o w e r / t u b
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor, wall covering or
The air barrier shall be installed behind electrical or communication
boxes or air-sealed boxes shall be installed.
The air barrier installed at exterior walls adjacent to showers and
tubs shall separate them from the showers and tubs.
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Recessed light fixtures installed in the building thermal envelope
shall be sealed to the finished surface.
Air sealing shall be provided between the garage and conditioned spaces.
When required to be sealed, concealed fire sprinklers shall only be
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings.
C o n c e a l e d
Electrical/phone box on
exterior walls
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
INSULATION INSTALLATION CRITERIA
EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software3/11/2022 9:38 AM Page 1 of 1
Air-permeable insulation shall
not be used as a sealing material.
The insulation in any dropped ceiling/soffit
shall be aligned with the air barrier.
Cavities within corners and headers of frame walls
shall be insulated by completely filling the cavity
with a material having a thermal resistance of R-3
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Rim joists shall be insulated.
Floor framing cavity insulation shall be installed to
maintain permanent contact with the underside of
subfloor decking, or floor framing cavity insulation
shall be permitted to be in contact with the top side
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
and doors
on exterior wall
requirements
Recessed light fixtures installed in the building
thermal envelope shall be air tight and IC rated.
sprinklers
Where provided instead of floor insulation, insulation
shall be permanently attached to the crawlspace walls.
Exterior walls adjacent to showers and tubs shall
be insulated.
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
a
18900 Schumann Road, Fort Pierce, FL, 34945
7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft²)
New (From Plans)
Detached
1
2
No
2700
7. Windows**
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=1.08 165.33 ft²
SHGC=0.29
Sgl, U=1.06 128.00 ft²
SHGC=0.28
N/A f t ²
N/A f t ²
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2700.00 ft²
R= f t ²
R= f t ²
10. Wall Type and Insulation
a. Concrete Block - Int Insul, Exterior R=4.1 2832.50 ft²
b. N/A R= f t ²
c. N/A R= f t ²
11. Ceiling Type and insulation level
a. Roof Deck (Unvented) R=20.0 2700.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts, location & insulation level
13. Cooling systems
14. Heating systems k B t u / h r
15. Hot water systems
a. Electric Cap: 50 gallons
EF: 0.95
b. Conservation features
None
d. N/A R= f t ²
Description Area
Insulation Area
Insulation Area
Insulation Area
Credits (Performance method) CF, Pstat
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
3.064 ft.
0.286
a. Electric Strip Heat 34.0 COP:1.00
a. Central Unit 41.0 SEER:16.00
k B t u / h r
Efficiency
Efficiency
a. Sup: Attic, Ret: Attic, AH: Pantry 6 85
R f t ²
8. Skylights
a. U-Factor(AVG):
S H G C ( A V G ) :
Description Area
N/A
N/A
f t ²
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:Date:
Address of New Home:City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
Page 1 of 1
FORM R405-2020
3/11/2022 9:38 AM