HomeMy WebLinkAboutGenerator Concrete Pad�J AMERICAST GENERATOR CONCRETE PAD CENGTN' T,��� �\ \ GENERATOR.___ f � f PAD f �) rr t1'a THICKNESS , f I t<< �1 �� .111VA PAD DIMENSIONS: CONCRETE GENERATOR Fa = GENERATOR UNIT BY o SEPARATE SUBMITTAL (SEE SCHEDULE FOR M MINIMUM WEIGHT REQUIRED) 54"LENGTH PLAN VIEW. CONCRETE ROAD MESH- MASTERFIBER. MAC100 GROUND- rC^M OTr VTC1.1 GENERATOR TABLE: (ON -GRADE APPLICATIONS ONLY) A M E I CAST - - _ ;!'%` 'BIADH1NAMRRIOA:• ~`�•. �'`��r % FED TAX i 2942wo UCENW 9599.19959161 SM Mff,=Ave. Fort Naa,FL 3012 T.I. 7T2.971-1951F= 7724640599 EmdL• n1eeQ.s.e"InsH <om orih.AemI1C101(.lwlnoee.� � J' �. HVHZ OR NON-HVHZ RISK EXPOSURE (EXP) RISK EXPOSURE (EXP) RISK EXPOSURE (EXP) COUNTY I C D 11 C I PD IN 1 ff 111 V16' �1 K- P � 1.-Dl U! P. BEACH 150 MPH 30.44 Psfj 36.94 Psf 170 MPH 39.09 Psf 47 44 Psf ,180 MPH 43.83 PPsf 53.19 P.sf. BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 Psf ;1801MPH 4k83 Psf 53:19 Pst MIAMI-DADE 165 MPH 36.83 Psf 44.69 Psf 175 MPH 41.43 Psf 50.28 Psf 186 MPH 46.80 Psf 56.80 Psf BRAND & MODEL CAPACITY WIDTH' i 1 . I 'LENGTH - �` -HEIGHT I I: .` r' `WEIGHT/ N,,, r.,Y ALLOWABLE f ,'PRESSURE COMMENTS Generac 005871 & 005883 10 KW 25.00 "-` 48:00""` -29.00 "' � 387`-Ibs,/. 54.00 Psf EXP C 186 MPH & D 180 MPH Generac 005872 & 005884 14 KW 25.00 " ': 48-00_'... 1 29.00 , 439 Ibs ;: 56.80 Psf UP TO EXPOSURE D 186 MPH Generac 6459, 6461, 6462 16 KW 25.00 " I -48.00 "= �29.00 " 1513 Ibs-, -,56.80 Psf Generac 006721 16 KW 25.00- 48.00 "` 29A0�-% . 448 Ibs - ` 56.80 Psf Generac 005873 & 005885 17 KW 25.00 " 48.00 " `29:00''-" �455 Ibs 56.80 Psf Generac 005874 & 005886 17 KW 25 00 :, 48 00 u r 29 00 '7 421albst ?. 56=.8&Psf Generac 005875 & 005887 20 KW 25:00 " w48:00'99 29 00-' t -451 Ibs') 56:80 Psf Generac 006729 & 006730 20 KW 25.00't y r : 48.00 -„ " 49 00; 516 Ib`s ? 56.80 Psf Generac 006551 & 006552 22 KW 25.00 " 48.00 " 29.00 " 526 Ibs 56.80 Psf Kohler 14RE5 & 20RES 14-20 KW 26.00 " 48.00 " 29.00 " 500 Ibs 56.80 Psf GE 40323GE & 40324GE 13 KW 35.00 " 39.40 " 39.00 " 540 Ibs 49.50 Psf EXP C 186 MPH & D 170 MPH GE04038215KW 15KW 33.00" 48.00" 30.50" 484lbs 56.80 Psf UP TO EXPOSURE D 186 MPH GE_04037817KW 17 KW 33.00" 48.00" 30.50" 484lbs 56.80 Psf GEf40330GE & 40331GE 20 KW 33.00 " 48.00 " 30.50 " 600 Ibs 56.80 Psf Briggs & Stratton 040243-0 10 KW 31.00 " 32.00 " 34.00 " 430 Ibs 56.80 Psf Briggs & Stratton 040302-2 12 KW 33.75 " 50.00 " 31.60 " 507 Ibs 54.00 Psf EXP C 186 MPH & D 180 MPH Briggs & Stratton 040303-1 15 KW 33.75 " 49.00 " 31.60 " 562 Ibs 56.80 Psf UP TO EXPOSURE D 186 MPH Briggs & Stratton 040304-1 18 KW 33.75 " 49.00 " 31.60 " 568 Ibs 56.80 Psf Briggs & Stratton 040305-1 20 KW 33.75 " 49.00 " 31.60 " 570 Ibs 56.80 Psf Generac 7035, 7036, 7037 16 KW 25.00 " 48.00 " 29.00 " 406 Ibs 47.44 Psf EXP C 186 MPH & D 170 MPH L� Generac.007038 & 007039 20 KW 25.00 " 48.00 " 29.00 " 448 Ibs 47.44 Psf Gen9e"rac 0,07042 & 7043 22 KW 25.00 " 48.00 " 29.00 " 466 Ibs 47.44 Psf "_`GENERATOR MOUNTING CONFIGURATION: GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF -DRILLING T_ F_ T_ F Q� F- I = GENERATOR (SEE CONCRETE PAD w_ w SCHEDULE FOR DIMENSIONS & WEIGHT = REQUIRED) 4„ +--32" WIDTH 54" LENGTH N SIDE VIEW FRONT VIEW m v 0 (R. WIND DESIGN REOUIREMENTS- (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE FIFTH EDITION (2014)) AT -GRADE SIGN METHOD ULTIMATE DESIGN WIND SPEEDi Vult = 186 mph NOMINAL DESIGN WIND SPEED�Vasd = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 FORCE COEFFICIENT Cf = 1.44 1 WIND PRESSURE!: P = qh G Cf = 56.80 Ib/ft2 (ASOL GENERAL NOTES ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION CONCRETE: ()- (6PSI EQUIVALENT,TITEN MIHD MIN.) 2-3/4" FULL EMBED 0 CONCRETE, 3" MIN EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2, EMBEDMENT AND EDGE DISTANCE EXCLUDES-FINISHES,.IF APPLICABLE. -_ T�- -3. --ENSURE-MINIMUM EDGE DISTANCE AS;NOTED m ANCHOR SCHEDULE. 4 ENSURE MINIMUM SPACING TO - 7 ANY ADJACENT'ANCHORS. S IFOLLOW MANUFACTURER'S I e---INSTALLATION�INSTRUCTIONS TO i INSTALL ANCHORS.. SEE'GENERATOR SPE GENERATOR 3/8" SIMPSON TITEN HD, SEE ANCHOR SCHEDULE 2"x3"IO/V GALV. STEEL - WASHER RUBBER VIBRATION PAD - 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. TO GENERATOR (SEE GENERATOR.S-PECS) 11. _ r THICK'GALVAN D--_' 1 WASHER& RUBBER -1 VIBRATION PAD' M ` CONCRETE PAD 6,000 PSI - C { / e. CONCRETE PAD r` )( LIGHTWEIGHT CONCRETE MIX LIGHTWEIGHT ` MASTERFIBER MAC 100 & ROAD rg" P'CONCRETE MIX-} MESH rT NOTES 'r , 4 .r '; FOAM CORE !I__l.0 Y•DISTANCE DEPEND ON'G NERATOR BASE LENGTH, NO LESS THAN 2". 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS 12. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2014 FLORIDA BUILDING CODE (Sth EDITION). REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINEDD IIN ACCORDANCE WITH THE APPLICABLE BUILDING -CODE SHALL BE -LESS THAN,OR EQUAL TO THE DESIGWP--RESSU'RE"ASD" CAPACITY VALUES LISTED HEREIN FOR ANY-ASSEMBLKASSHOWN DIMENSIONS ANDIWEIGHT OF'UNITS SHALL CONFORM TO SPECIFICATIONS STATE D=HEREIN:-., UNITS MUST BE CENTERED 6N-OADi WITH OPPOSITE SIDES HAVING EQUAL CLEARANCE„ A -MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED._`~--_ /,+' \, THE AREA UNDER CONCERETE'SLAB ON -GROUND -SHALL- HAVE ALL VEGETATION, STUMPS, ROOTS,ANI FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION.'ON,COMPACTED SOIL AS VERIFIED BY OTHERS. RESISTANCE TOOSUIDING OFjITHE-PtAD ON,THElGROUND,ISLNOTj PART OF THIS`DOCUMENT AS SOIL CHARACTERISTICS ANO PAD PLACEMENT VARIESf � rR' ELECTRICAL GROUND -,WHEN R Q I ERI ER D, TO'BE-DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTINGCONTRACTOR: THIS DOCUMENT IS- GENERICfAND„DOES'NOT PERTAIN TO ANY SPECIFIC PROJECT SITE -INFORMATION CONTAINED�HEREIN IS BASED ON CONTRACTOR=SUPPLIED`DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS: DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND',OTHER DESIGN CRITERIA `THEY,MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL,BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK'UPON DISCOVERY -OF ANY4'r` T I. -., ,� � INACCURATE INFORMATION PRIOR:TO:MODIFICAT:ION OF ` EXISTING FIELD CONDITIONS'AND FABRICATION AND INSTALLATION OF MATERIALS' iALTERAbf_( : .OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. BENNARDO, P.E. 1 L. BENNARDO, P.E. O N Z Oa ILMn,uEn i uiHJ9wyEn W03 -, u) mX-, ZW 0 2 2 y W -zo-t- c�a~'aCEW` <w¢wSWcDo I1' 0t m -.C7ce E K WW OND�wwu O U.1 _O6 U)Cea=w w O w w � p Ti Ld 00 Q � o N Q O w alrt U ' a M w P, � o °i fu a o (0 w a ~a ce C7 w 3:z 2 C p� G m a � rn LL C6 w w CO x N O Mo Z U a Paz of 0 /F w w Q m (D Q IL <_ m O W J LL 4 � y � � I- zz r :z O LL Y U'mF iz ` Jm LL Z- K 0 0 0 3 g �oamz O azwzo tot w � wzyoo zo�d' y Q � F y z Ed 3Qa = 0 COPYRIGHT ENGINEERING EXPRESS 17-3961.1 SCALE:NTS UNLESS NOTED "I u I