Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014 RECER'7-D SEP 13 2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: NEWLAND INVEATMENTS Builder Name: Street: 8001 SEBASTIAN ROAD Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (352.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 248.00 ftz 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 104.00 ftz c. N/A R= ftz 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (234.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 234.00 ftz 6. Conditioned floor area above grade (ftz) 234 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 7. Windows(9.0 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ftz 6 25 a. U-Factor: Sgi, U=0.79 9.00 ftz SHGC: SHGC=0.50 b. U-Factor: N/A f 2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 29.0 SEER:14.00 c. U-Factor: N/A ftz SHGC: d. U-Factor: N/A 13. Heating systems kBtu/hr Efficiency ftz a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems - None required 8. Floor Types (234.0 sqft.) Insulation Area a. Cap: N/A a. Slab -On -Grade Edge Insulation R=0.0 234.00 ftz b. Conservation features EF: 0.000 b. N/A R= ftz c. N/A R= ftz 15. Credits CF, Pstat Glass/Floor Area: 0.038 Total Proposed Modified Loads: 11.16 PASS 'Total Baseline Loads: 11.30 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this ��TKE p - ' Code. calculation indicates compliance �O PREP E V. With the Florida Energy Code. F• nur'��•. •: °?•� ";� Before construction is completed 41 DATE: - this building will be inspected for N- - compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. y,S G'pD with the Florida Energy Code. WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. File Cody 8/4/2017 2:07 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 rvRlVl PROJECT Title: Building Type: NEWLAND INVEATMENTS User Bedrooms: 0 Address Type: Street Address Owner Conditioned Area: 234 Lot # # of Units: 1 Total Stories: 1 Blodc/SubDivislon: Builder Name: Worst Case: No PlatBook: Penult Office: Jurisdiction: ST. LUCIE COUNTY Rotate Angle. 0 Cross Ventilation: Street 8001 SE13ASTIAN ROA Family Type: Single-family Whol®House Fan: County: City, State, Zip: ST. LUCIE COUNTY FT. PIERCE, New/Existing: Addition FL, Comment CLIMATE / V Design Location TMY Site IECC . Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp _ FL, Fort Pierce FILVERO_BEACH_MUNI Winter Summer Degree Days Moisture Range 2 38 90 70 75 209 62 Low BLOCKS Number Name Are a 1 Block1 234 Number Name Area Volu m 1 Main 234 1872 # Floor Type S ace 1 Slab -On -Grade Edge Insulatio Main V # Type Materials 1 Gable or shed Composition shingles V # Type Ventilation 1 Full attic Vented # call in Type Spa Under Attic (Vented) Mai Volume 1872 SPACES e Kitchen Occupants Bedrooms InfilID Finished Cooled Heated Yes 1 1 Yes Yes Yes FLOORS Perimeter R-Value Area Tile Wood Carpet 82 ft 0 234 fN 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emltt Deck Pitch Area Area Color Absor. Tested Tested Insul. (deg) 253 ft? 48 fta Light 0.6 No 0.9 No 0 22.6 ATTIC Vent Ratio (1 in) Area RBS IRCC 300 234 W N N CEILING a R-Value Ins Type Area Framing Frac Truss Type n 30 Blown 234 fta 0.11 Wood 8/4/2017 2:07 PM EnergyGauge® USA - F18Re82014 Section R405.4.1 Compliant Software Page 2 of 4 8/4/2017 2:07 PM EnergyGauge® USA - F18Re82014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 Adjacent WALLS Space Cavity Width Height Sheathing Framing Solar Below RA/aIlle Et In Ft In Area R-Vah,e—Eraction Absor 0 _ 1 S 2 W _ 3 N Exterior Concrete Block - Ext Insul Main 4.1 13 8 104.0 ft2 0 0 0.5 Exterior Concrete Block - Ext Insul Main 4.1 18 8 144.0 ft2 0 0 0.5 Garage Frame - Wood Main 11 13 8 104.0 ft2 0.23 0.5 0 0 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 W Insulated Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered Proposed orientation. / V/ # Wall Omt ID Frame Panes Overhang NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 2 Metal Single (Tinted) Yes 0.79 0.5 9.0 ft2 2 ft0 in 1 ft4 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 117ft2 117ft2 13ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 218.4 11.99 22.55 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 14 29 kBtu/hr 870 cfm 0.85 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF ft2 8/4/2017 2:07 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 25 ftz Attic 1 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: l Cooling Jan Heating Jan Feb HFeb Mar Mar E Apr Apr f Ma May Jun Jun r]Jun Jul Jul ri Aug AuSep Se Oct E Oct Nov Nov [ Dec [Xl Dec Venting Jan Feb X Mar [X] Apr [ May Jul Aug Se [Xl Oct X Nov [ I Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8/4/2017 2:07 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: NEWLAND INVEATMENTS Builder Name: Street: 8001 SEBASTIAN ROAD Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity s aces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be airtight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 8/4/2017 2:07 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 r FORM.R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 8001 SEBASTIAN ROAD, FT. PIERCE, FL, I. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows" Description a. U-Factor: Sgl, U=0.79 SHGC: SHGC=0.50 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. WA c. N/A Addition Single-family 1 0(0) No 234 Area 9.00 ftz ftz ftz ftz Insulation R=0.0 R= R= 2.000 ft. 0.500 Area 234.00 ftz ftz ftz 9. Wall Types a. Concrete Block - Ext Insul, Exterior b. Frame - Wood, Adjacent c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems - None required a. b. Conservation features 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Insulation R=4.1 R=11.0 R= R= Insulation R=30.0 R= R= Area 248.00 ft2 104.00 ftz ftz ft Area 234.00 ftz ftz ftz R ftz 6 25 kBtu/hr Efficiency 29.0 SEER:14.00 kBtu/hr Efficiency 27.0 COPA.00 Cap: N/A EF: CF, Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/4/2017 2:07 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 u -�- 9 Pro ect Summary Job: wri htsoft® .� � Date: Aug 04, 2017 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For: NEWLAND INVESTMENTS 8001 SEBASTIAN RD., FT PIERCE,FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 - OF Design TD 28 OF Heating Summary Structure 18466 Btuh Ducts 4573 Btuh Central vent (22 cfm) 692 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 23731 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ftz 1249 1249 Volume ()ft3) 11241 11241 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 84 43 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.1 kW 174468 Btuh 967 cfm 0.042 cfm/Btuh 0.50 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily.range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 14197 Btuh Ducts 6854 Btuh Central vent (22 cfm) 371 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipmenisensible load 20350 Btuh Latent Cooling Equipment Load Sizing Structure 2400 Btuh Ducts 1850 Btuh Central vent.(22 cfm) 939 Btuh Outside air Equipment latent load 5190 Btuh Equipment total load 25540 Btuh Req. total capacity at 0.70 SHR 2.4 ton Cooling Equipment Summary Make EXISTING SYSTEM Trade Cond Coil AHRI ref Efficiency 13.0 EER, 14 SEER Sensible cooling 20300 Btuh Latent cooling 8700 Btuh Total cooling 29000 Btuh Actual air flow 967 cfm Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _,— + wrilghtsoft• Right -Suite® Universal 2017 17.0.14 RSU08101 ACCK ..s\Quick Calcs\Documents%NEWLAND INVESTMENTS.rup Calc = MJ8 Front Door faces: N File Copy 2017-Aug-07 08:52:04 Page 1 wrightsoft° Right M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM Job: Date: Aug 04, 2017 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 134.0 ft 9.0 ft d 1249.0 ft2 ENCLOSED GARGE 31.0 ft 9.0 ft heat/cool 14.0 x 17.0 ft 238.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 � _ 13A-4ocs 10A-m IA-clom IA-c1om 1A1om 13A-4ocs IA-clom 11DO _ 13A-4ocs 1A-clom 1A-clom 1A-clom 13A-40cs IA-ciom 0.143 1.670 1.270 1.270 1.270 0.143 1.270 0.390 n' n n n -,n- a a a ~4.00._ 46.76 35 56 35.56 --35.56 4.00 35.56 10.92 2.55 25.31 34.77 34.77 _34.77_ 2.55 91.12 ^ 459 41 4 9 390 0 0 0 134 0 _ 19 249 18 15 30 ______21, 237 0 1562 1908 142 320 535 320 210 996 652 533 1067 __229 949 533 993 1033 139 313 340 820 218 633 638 522 1043 238 603 1367 �-126 0 0 0 126 0 0 0 125 0 ^505 0 0 0 32f 0 0 0 V�J 162 9 19 153 9 _ _ 1919 ' 0 0 0 0 �_ 0 0 0 499 320 21.0 0 0 0 0 0 317 820 21_8 i 0 0 0 0 Q 0 0 W 0.143 1.270 1.270 1.270 0 3M 0.143 1.270 s s s s _s__ w w 4.00 35.56 35:56 35.56 10 92 4.00 35._56 _11.31 W 2.55 34.77 34.77 34.77 _ 11.31` 2.55 91.12 -� 333 18 15 30 _______21. 252 15 _ _. 0 0 D 0 0 0 0 0 0 P_ C F 12COsw 166-30ad 22A-tpl_ 0 Q l _ 0.032 U.989 r - _ _2 _.55 _0.90 27 69 _1.28. _ 1.68 '_ Tdd 216. _ 1249 _ 1249 �- 216 1249 !_ 134: _,_550; _ 1119 ___3711_ 2098 `'_0 126 238 ^� 238 _w 126 238 _i_31. u 321_ 213 __858 162 400 6 c) AED excursion 0 82 Envelope loss/gain 15871 117961 29271 2319 12 a) Infiltration b) Room ventilation 2594 0 710 0 600 0 164 0 13 Internal gains: Occupants @ 230 Appliances/other 3 690 1000 0 0 0 Subtotal (lines 6 to 13) 18466 14197 3527 2484 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 25% 48% 0 0 0 18466 4573 0 0 0 14197 6854 25% 48% 0 0 0 3527 874 0 0 0 2484 1199 Total room load Air required (cfm) 23039 967 1 21051 967 4401 1851 3683 169 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� wrightsoTt` 2017-Aug-07 08:52:04 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...s\Quick Calcs\Documents\NEWLAND INVESTMENTS.rup Calc = MJ8 Front Door faces: N - wrightsoft° Rig t M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Aug 04, 2017 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area EXISTING HOUSE 103.0 ft 9.0 ft heat/cool 1.0 x 1011.0 ft 1011.0 ft2 Ty Construction number U-value (Btuh/ft'-°F) Or HTM (Btuh/ft2) Area (W) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool - 6 11 A _ V!✓ 13A-4ocs 1OA-m 1A-c1om 1A-c1om _1A_c16m 13A-4ocs 1A-clom 11 DO 13A-4ocs - 1A-clom 1A-clom 1A-clom 11 DO _ 13A-40cs IA-clom_^_ 12GOsw _ 6. 443 1.670 1.270 1.270 1.270 0.143 1.270 0.390 n n n. n -nw a a a 4:00 46.76 35.56 35.56 -35:56 4.00 35.56 10_92 4.00 35.66 35.56 35.56 _10.92 4.00 - 35_56 _ 0.90 V27 89 - 2.55 25.31 34.77 34.77 __34.77 2.55 91.12 11.31_ _J____ 333 41 4 9 15. 9 0 0 264 0 0 0 0; 9 0 0 1058 1908 142 320 533. 36 0 0 - 672 1033 139 313 522 23 0 0 ' - - _ _M 0.143 1.270 1.270 1.270 0 390. 0.143 �_ 1.270 0.091 0.032 s s s s _s- w w_ - 2.55 .34.77 34.77 34.77 11 31_ 2.55 91.12_ 1.68 333 18 15 30 21 252 15 249 18 15 30 996 652 533 1067 229 - 633 638 522 1043 238 603 1367 1698 - Vdl T--G_ P `-21 237 0 949 533. 906 - 1011 1011 C 1613-30ad =6.- Q _- 1011. __103 `2852-- 6 c) AED excursion -82 Envelope loss/gain 12944 9477 12 a) Infiltration b) Room ventilation 1994 0 546 0 13 Internal gains: Occupants @ 230 Appliances/other 3 690 1000 Subtotal (lines 6 to 13) 14938 11713 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 25% 48% 0 0 0 14938 3700 0 0 0 11713 5655 Total room load Air required (cfm) 18638 782 17368 798 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2017-Aug-07 08:52:04 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 '�� ...s\Quick Calcs\Documents\NEWLAND INVESTMENTS.rup Calc = MJ8 Front Door faces: N Duct System Summary Job: - wrightsoft® Date: Aug 04, 2017 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information For: NEWLAND INVESTMENTS 8001 SEBASTIAN RD., FT. PIERCE,FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H20- 0.50 in H2O 0.250 / 0.250 in H2O 0.383 in/100ft 967 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.383 in/100ft 967 cfm 131 ft Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk ENCLOSED GARGE h 4401 185 169 0.383 7.0 Ox0 VIFx 25.6 105.0 EXISTING HOUSE-D c 17368 782 798 0 0 OXO VIFx 0 0 Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 967 967 0 0 0 0 Ox 0 VIFx c wri htsoftW 2017-Aug-07 08:52:05 �. 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ACCA ... s%Quick Calcs%Documents%NEWLAND INVESTMENTS.rup Calc = MJ8 Front Door faces: N Job #: Performed for: NEWLAND INVESTMENTS 8001 SEBASTIAN RD. FT. PIERCE,FL QUICK CALCS, INC. 317 ST. LUCIE LN. FT. PIERCE, FL34946 Phone:772-466-6799 Fax:772-466-6796 QUICKCALCS@AOL.COM File Co Scale: 1 : 89 Page 1 Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Aug-07 09:35.49 ocumentslNEWLAND INVESTME...