HomeMy WebLinkAboutProduct Approval - Roofing UnderlaymentsilF,`VD OCT-Al z7i_
oridaBuildingvode Oiine `.- . --..!_htt s://wwwfloridabu" _,, •or�Pr/Pr— apP—t.asPx?aram=wGEVX.--
r,_i3 � `z'- � ,: BCLS Home Lng to User Reghtratlon Hot Tapts
Mines,, �[' IproductApproval
Professil'al t USER: Public User
Rrecluiatio,n
Submt Surcharge Stats & Facts Publications FSC Staff SC1S Site Map Links Search
Product Anoroval tJgW > Product or A1300=10 Seart > AonkaI n I1st > AppkaSm Detai
iE FL #
-FL16048-R3
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer TRI-BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street.
Merrillville, IN 46410
(201) 842-2449
david.ruiz@tribuiltmateriaisg roup. com
Authorized Signature David Ruiz
david.ruiz@tribuiltmaterialsgroup.com
-technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, N3 07073
(201)842-2449
david.ru*iz@tribuiltmateriaisgroup.com
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By.
Certificate of independence
Referenced Standard and Year (of Standard)
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
CONCEALEOFASTENE95 OR al
ARE THE RESPONSIBILITY Gt
Roofing CONTRACTOR OF REQU
Undedayments
Evaluation Report from a Florida Registered Architect or Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
10/16/2017
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL16048 R3 COI 2015 01 COI Nieminen.pdf
Standard
Year
ASTM D1970
2009
ASTM G155
2005
FRSA/rRI April 2012 (04-12)
2012
TAS 103
1995
1 of 2 File C0� 4/2016 9:58 AM
a
.arid'a Building Code Online
https://www.flori,dabi, --'ilg.org/pr/pr_appjd.aspx?param=wGEVX...
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Method 1 Option D
Date Submitted 10/08/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
Summary of Products
FIL # { Model, Number or Name _ Description ^ ~ ~
j 16048.1 ; TRI-BUILT Roof Underiayments ! Self -adhering, modified bitumen roof underlayments 1
--- ---- ,
Limits of Use
Installation.instructions
Approved for use in HVHZ: No
FL16048 R3 II 2015 10 FINAL ER TRI-
Approved for use outside HVHZ: Yes
; BUILT UNDERLAYMENTS FL16048-R3.odf
Impact Resistant: N/A
;Verified BY: Robert Nieminen PE-59166
Design Pressure: +N/A/-45
j Created by Independent Third Party: Yes
Other: L) The design pressure noted herein pertains to use
Evaluation Reports
OF foam -on rile systems overtop the self -adhering
undenayment for one particular application. See ER Section
FL36048 R3 AE 2015 10 FINAL ER TRI- C
i
!
5.6 for details. 2:) Refer to ER Section 5 for other Umits of
BUILT UNDERLAYMENTS FL16048-R3 pdF j
Created by Independent Third Party: Yes
Use.
eadt C
&oatasLUS :: r 940 North Monroe st t Tatahass c+ 22399 Phone; 850-487-1824
The. State'of Florida Is an AA/EEO employer. Copylght 2007-2Q13 State ofEJ2jV :: PrNacv statement :: 6cce5sJbWv statement.:: Refund Statement
Under Florida law; emal addresses are public records. R you do not want your e-mal address released In response to a-pub8o-records request, do not send electronic
Mal to thts entity. Instead, contact the office by phone or by tradftbnal coal. IT you have any questions,. please contact 850.487.1395.'pursuant to Section
455.275(1), Florida Statutes; effectIve October 1, 2012, iceensees.8censed under Chapter 455, F.S. must provide the Department with an emafl address t they have
one. The emals provided maybe used for official communication with the licensee. Howeveremal es addressare pubne record, if you do not wish to supply a
personal address, please provide the Department with an emall address which can be made available to the public.7b determine r youare a licensee under chapter
455, F.S., please ckk here .
Product Approval Accepts:
® jlg*7 i t{:i
,tymrlil t:. .
wig 0.
2 of 2 5/24/2016 9:58 AM
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization N95o3
,IlqrrY ERD 353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
EVALUATION REPORT FAX: (203) 262-9243
Allied Building Products Corp. Evaluation Report A42960.10.12-R3
dba TRI-BUILT Roofing Products FL16048-R3
9050 Louisiana Street Date of Issuance:10/25/2012
Merrillville, IN 46410 Revision 3: 10/08/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with. the 5th Edition (2014) Florida Building Code
sections noted. herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity] ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then itshall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through S.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
gntlttra,
rov I
The facsimile sealal)"aringwasautharitedbrRobert Nieminen.
,,A �
P.Eao10/08/201S. This does not serve asap elects iWly signed
'
document. Slgned, sealed hardcoples have been transmitted to the
PtadattA IAd 1
CERTIFICATION OF INDEPENDENCE: th
PP a m n tinter and to e named client
1. Tdrflty)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY . E D
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations J Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.4, 1507.2.8, 1507.2.9.2,
Physical Properties
ASTM D1970
2009
1507.4.5.1, 1507.5.3, 1507.7.3
1504.6
Accelerated Weathering
ASTM G355
2005
1507.3.3
Installation Practice
FRSAJTRI April 2012 (04-12)
2012
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
Physical Properties
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties
S40540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
S40540.03.14
03/26/1014
ERD (TST6049)
Physical Properties
S44870.04.14-2
04/02/2014
ERD (T5T6049)
Physical Properties
S44870.04.14.3
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-1
04/10/2014
ERD (TST6049)
Physical Properties
S44870.04.14-4
04/10/2014
ERD (TST6049)
Physical Properties
S43530.02.14-1-R1
05/14/2014
ERD (TST6049)
Physical Properties
S43530.05.14
05/28/2014
ERD (TST6049)
Physical Properties
S40540.10.14
10/31/2014
ERD (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SC8520.04.15
05/27/2015
UL, LLC. (QUA9625)
Quality Control
Multiple -Listing R16814
09/04/2015
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Self-Adherina Underlayments:
4.1.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width.
4.1.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment
4.1.3 Tri-Built_S.mooth'_HT_SJA,Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified
bitumen roof underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or.previous versions thereof, is/was
used for permitting -or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in'the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R3
Cer0fKate of Authorization #9503 FL16048-BB
Revision 3:10/08/2015
Page 2 of 5
I RINITY ERD
5,4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underiavmPntr asp me F.,u.,,.
TABLE 1: ROOF COVER OPTIONS
j
I Underlayment
Asphalt k"
iShingles�
!Nall=OriTtle
Foam -On Tile
-
i_ Mefal��`"
Wood Shakes
Slate
-- -- - -
& Shingles
Tri-Built Sand-R SA Shingle
Underlayment
Yes
No
No
No
Yes
Yes
Tri-Built S/A HT TU
Yes
Underlayment
Yes
Yes
See 5.5.1
Yes.
Yes
Yes
Tn-Built.Smooth H_ T_
,Underlayment,,,
_ _ :_ ._
No
No
Yes`"
Yes
Yes
5.5.1 "Foam-0n Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long
term aging data from an accredited testing laboratory is provided.
➢ Tri-Built 5/A HTTU Underlayment with3M' 2-Component Roof Tile Adhesive AH-160 (FL6332) or Dow
Tileeond'm Roof Tile Adhesive (FL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed 056; ASTM D41 primed structural
concrete.
While not required over plywood, 056 or Southern Yellow Pine substrates, TRI-BUILT recommends priming
the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT requires
tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -
adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built S/A HT TU Underlayment applied to:
➢ Dens Deck Prime; SECUROCK Gypsum-Fiber.Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of .the prepared roof covering manufacturer's Product Approval, For installations
under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and
installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D
or TAS 114, Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
➢ ASTM D226, Type I or li felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached
per minimum requirements of FRSA/TRI April 2012 (04-12).
Exterior Research and Design, LLC. Evaluation -Report A42960.30.12•R3
CaW lcote of Authorization #9503 FL16048-R3
Revision 3:10/08/2015
Page 3 of 5
5.6.4
5.6.4.1
5.7
5.7.1
5.7.2
I FUNjW : ERD
Wind Resistance for Underlayment SLostems in Foam -On Tile A lications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (0412) and are used in foam -on file
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing _pressure divided by 2 (the 2 to 1 margin of safety, per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures.
Maximum Design Pressure --45 0 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM-041
Underlayment: Tri-Built 5/A HTTU Underlayment, self -adhered.
Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-BuiltS/A HTTU Underlayment shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 TRl-BUILT Roof Underlayments shall be installed in accordance with TRl-BUILT published installation
requirements. subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Bul)tSand-R SA Shin le Underla ment Tri-Built S A HT TU Underlayment or Tri-Built Smooth HT S A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRl-BUILT recommends priming the deck if the final roof cover is not slated for
installation within-24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps
shall be sealed using either heat -.welding or hot air welding techniques.
When installing at slopes above 8:22, Allied Building Products Corp recommends back -nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge In
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications FTri Baug1R 5/A HTTU Underlayment only):
Reference is made to FRSA/TRU April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Exterior Research and Design, LLG eeWfkate Of Authwhatfon rr9503 Evaluation Report A42960.2D.12-R3
FL16048-R3
Revision 3:10/08/201s
Page 4 of 5
7. BUILDING PERMIT REQUIREMENTS: TRINITY ' ER D
As required by the Building Official;or Authority Having Jurisdiction in order to. Properly evaluate the installation of
this product.
S. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C.[ertykoteoJAutharkatton:v9303 Evaluation Report A42960.10.12-R3
FL1604&R3
Revision 3:10108J2D15
Page s of 5