HomeMy WebLinkAboutProduct ApprovalRECEIti'=D OCT 11 Z017
Professional Regulation
BCIS Home I Log In I User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
Florida
Product Approval
i 1 H USER: Public User
ar��YlrtiY,Lb:
product Approval Menu > Product or Anollcatlon Search > Application LN > Applintion Detail
FL # FL19902 g /—�%D
Application Type New ST.LUQL^NTY �L'IIaDING D 'ISIo
Code Version 2014 REVIEWED FO IMP, \C
Application Status Approved REVIE-',N'1EkBY,
DATE
Comments PLANS AND PFziHIT MUST BE KEPT ON JOB
Archived ❑ OR NO INSPECTION WILL BE BLADE.
Product Manufacturer Metal Sales Manufacturing CorporatigfHE$E PJ ikNS AND ALL P13S3POSED WORK
Address/Phone/Email 545 South 3rd Street, Suite 200 ARE $ilfla.IE.OT TO ANY CORRECTIONS
Louisville, ICY 40202 I3FQUiAEl3 6Y FIELD INSPECTORS THAT
dster er@me 2 MAY SE NECESSARY IN ORDER TO
dstermer@ m etalsales. us. com
COMPLY WITH ALL APPLICABLE CODES.
Authorized Signature David Stermer
dstermer@metalsales.us.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIDIUTY OF THE
CONTRACTOR OF RECORD
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Bala Sockalingam
PE-62240
Keystone Certifications, Inc.
12/31/2020
Yoosef Lavi, P.E.
1 Validation Checklist - Hardcopy Received
FL19902 RO COI CertificateIndeoendence odf
Standard Year
UL 1897 2004
UL 580 2006
Method 1 Option D
File COPY
Date Submitted 02/13/2016
Date Validated 02/18/2016
Date Pending FBC Approval 02/22/2016
Date Approved 04/12/2016•
Summary of Products
FL #
Model, Number or Name
Description
19902.1
SV-Crimp
Min. 26 ga., 24" wide through fastened roof panel over min.
15/32"thick plywood deck or 7/16" thick OSB with fasteners
through panel rib.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL19902. RO 'II EvaluationReDortC2076 1.Ddf
Approved, for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-172.5
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 36" o.c.
FL19902 RO AE EvaluationReDortC2076 1.Ddf
and 172.5 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
Back Nex
Contact Us :: 2601 Moir Stone Road, Tallahassee FL 32399 Phone: 850.487-1824
The State of Florida Is an WEED employer. Coovdnht 2007-2013 State of Florida.:: Privacy Statement :: Accesslbility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.139S. -Pursuant to Section 45S.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emalls provided may be used for official communication with the licensee. However email addresses are public record. if you do not wish to supply personal address,
please provide the Department with an emall address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
dick tam_
Product Ap��prrjoval Acceptsl
am 1�1
Credit Card
Safe
� � 1
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
'26 GA. 5V-CRIMP PANEL' !
FLORIDA BUILDING CODE 5TH EDITION (2014)
FLORIDA. PRODUCT APPROVAL
FL 19902.1 i
ROOFING '((
METAL ROOFING f
Prepared For:
Metal Sales Manufacturing Corporation i
545 South 3r, Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 8554290
Prepared By:
Sala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (918) 493-3568
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Load Span Table (1 Page)
Report No. C2076-1
Date: 2.13.16
eeeevQ, �\G N S E •• 9�! ,si�i
i
- y • • M
- T • • W -
LU
Q��Vee
•��e�O,r l O P ••• �,,,e
2-, l3,Zol(Q
FL 19902.1
C2076-1
2.13.16
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 7/16" thick OSB or min. 15/32" thick plywood at max span of 24"
for new and existing constructions. Designed and installed as per FBC
2014.
Deck Attachment: .8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and edges
Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1
Slope: Ifd,12 or -greater in accordance.withFBC 2014 Section -1507A.2.
Design Uplift Pressure: 30.0 psf @ fastener spacing of 36" o.c.
(Factor of Safety = 2) 172.5 psf @ fastener spacing of 6" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum of
3/8" and installed as per Metal Sales current installation procedure.
At panel ends @ 6" o:c. across panel. widthi
At intermediate @ 12 oX._across_panel.:widtlr'
Test Standards: Roof assembly tested -in accordance with UL580-06 `Uplift Resistance
of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Metal Sales load span table. This -evaluation report
is not applicable in High Velocity Hurricane Zone. Fire classification is
not within scope of this Evaluation Report. Refer to FBC 2014 Section
I
FL 19902.1
C2076-1
2.13.16
Page 3 of 3
1505 and current approved roofing materials directory or ASTM
El 08/UL790 report from an accredited laboratory for fire ratings of this
product.
Supporting Documents: UL580 & 1897 Test Reports
PRI Construction Materials Technologies
MSMC-017-02-01, Reporting Date 9/20/13
PANEL OVERLAP
vml�
- 5V-CRIMP
a
FASTENER AT PANEL FLAT
SEE DETAIL 2 / SEE DETAIL 1 REQUIRED FOR PANEL
ENDS ONLY.
Li
R P.
', II
0 A 9
M&MUM ATTACHMENT: FASTENER SPACING AS PER
DESIGN UPLIFT LOAD TABLE
8d x 25' LONG PING SHANK NAIL
UNDERLAYU. SHALL DE INSTALLED OR B8 x 2" LONG WOOD SCREWS
a
AS PER MANUFACTURER'S INSTALLATION SPACED G 6" O.C. IN THE FIELD
4
GUIDEUNES L: AT EDGES
i
MIN. 2X- WO00 RAFTER/JOIST/
TRUSS AT MAX. 24" O.C.
o 0
TYPICAL PANEL INSTALLATION X-SECTION
= cs
a =moo
= NQo
>
�y1
0-I6 OR 010-14 WOODSCREWS
WITH SELF SEALINGWASHER AT
4
!MA%IMUM SPACING OF 36' O.C.
o h1
n�1
5V-CRIMP
PAW GA. 26
iNow
3T>!
UNDERfAYMENTJ
DETAIL 1
PLYWOOD 615/32K T(HLICK (IIIN.)
hnl'sOR "OOD�SCAT
gs
£ Lmic
='AUM SPACING OF 36' D.C.
MIN 26 GA,
0OS.5V-CRIIAP
lq�
S 7/16" THICK (MIN.) OR
UNDERLA.YIJENT
DETAIL 2
PLYWOOD 15/32' THICK (ION.)
GENERAL NOTES:
�-
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
-
a
o
nem
FLORIDA BUILDING COCE'(FEC).
a
2. ROOF PANELS SHALL BE MIN. 26 GA. (I = 0.0197. EFFECTIVE COVERING
WIDTH OF PANEL 24.
s
a
a�
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING u STRUCTURE AS
�j
� �BE
SPc"CIFlED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL.SE DELERMINED FOR EACH. PROJECT. THIS
j(
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN YIND LOADS
Ir�
ARE GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING.
zH
5. ALL FASTENERS MUST BE IN ACCORDANCE WTTH THIS DRAWING do THE FLORIDA
BUILDING CODE IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
iu
REQUIREMENTS OF THIS ORAW1NG is THE CODE. THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESP04SIBlUTY OF OTHERS.
METAL SALES MANUFACTURING CORPORATION
26 GA. 5V-CRIMP PANEL
Design Uplift Loads
Description
Fastener Spacing
along panel length
(in)
Allowable Uplift
Load
(psfl
5V-Crimp Panel
Min. 26 ga.
Panel Fasteners
#9-16 or #10-14 hex head
wood screws with sealed
washer
6
172.5_ J
__- _
9 — --
_
---- 120.0
_ 900.,
.__72.0 _-__• _ ,-_
60.0
--
_ 15
_ 18
— 21
51.4
45.0
-_
-__ __-----_24
27
40.0
36.0
30
- - 36
30.0
Notes:
1. The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 19902.1 and Metal Sales current installation
procedure.
1216 N Lansing Ave., Suite C
Tulsa, Ok 74106
918 492 5992
A`Q`I i i e u►®o"
aO;®oP �O �KAS'AIQ ,�,��i
'9 0
1.
�: No 62240
icy
a `
-o gTATE OF : W
O
2. 1-6 ,'-01 �
Bala Sockalingam, Ph.D., P.E.
FL 62240