HomeMy WebLinkAboutEngineeringDATE: 10/09/17 ENGINEERING & TESTING, INC. Phone: (866) 781_-6889 •Fax: (866) 784-8550 www.flolioaengineei-ingandtesting.com 250 S.W.13`h Avenue Pompano Beach, FL 33069 JOB ORDER #: 17-3277 CLIENT: Vital Roofing ADDRESS: 320 N.E. 36th Street Oakland Park, FL 33334 PROJECT: S2SH4U, LLC Flat Wood Roof Deck ADDRESS: 2678 Niagara,Avenue Fort Pierce, Florida 34946 FBC 2014/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Proiect Information: Height = 10' Exposure: C Basic/Ultimate Wind Speed: V,,It=170 mph Length = 18' Category: II Nominal Wind Speed: Vasa=Vult*40.6 Width = 18' Slope: < 7° (asd = allowable strength design) Parapet Wall: N/A Residential KZ = 0.85, Kzt = 1.0, Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*KZKztKdV2 Velocity Pressure (,,It): q=0.00256(0.85)(1.0)(0.85)(170)2 = 53.45 psf Velocity Pressure (asd): q=0.00256(0.85)(1.0)(0.85)(170*40.6)2 = 32.07 psf Width of Pressure Coefficient: 0.1(18') = 1.8' 0.4(10') = 4.0' ) use: 3'0" Effective Wind Area: <10f 2 For parapet height three feet (T) or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) GCPi = 0.18 0-14 `*z& Quality ' `t�\�1� �/ ✓lssurance &19 Page 2, 10/09/17, Job OL- #17-3277 Vital Roofing PILO A S2SH4U, LLC - Flat Wood Roof Deck 2678 Niagara Avenue; Fort Pierce, Florida 34946: Design Pressures Based on Vasd: 1) Field P1 = 32.07*[(-1.0) — (0.18)] = -37.8 psf 2) Perimeter P2 = 32.07*[(-1.8) — (0.18)] = -63.5 psf 3) Corners P3 = 32.07*[(-2.8) — (0.18)] = -95.6 psf Attachment Requirements Per RAS-117: Based on the requirements of N.O.A. #16-0413.06, pg 14 of 15, System Type E, Option # 2, with a maximum design pressure of-52.5psf; the following are our recommended fastening patterns to attach the proposed minimum two plies of PermaPly or Ventsulation base sheet to the 19/32" or greater plywood or wood plank deck utilizing approved Ultrafast Fasteners and Metal Plates: Field: 9" o.c. @ 4" laps and 2 staggered rows 12" o.c. Perimeter: 9" o.c. @ 4" laps and 3 staggered rows 9" o.c. Corners: 9" o.c. @ 4" laps and 4 staggered rows 9" o.c. Notes: Corners and perimeter area dimension shall not be less than a = 3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. ``O�i 111 l %®j�® Sincerely, �v� ���� .,�; 6�f �� , a 0 9e Mark A. Me s,',P.E8T,q� or Florida Engine�r •Nesting, Ind,4 Florida Reg. T O ORIDA, -��-e i � Certificate of Auth " tbk � �6�23 Membrane Type: APP Deck Type 1: Wood, Non -Insulated Deck Description: 1962" or greater plywood or wood plank System Type E: .Base sheet mechanically fastened. All General and System limitations apply. Base Sheet: (Option #1) Minimum two plies of PermaPly 28 or Ventsulation simultaneously fastened to the dcckJawed 4" and fastened with approved roofing nails and tin s .c. at the lap and two rows s aggere m t e center " o.c. (Option #2) Minimum two plies of PermaPly 28 or Ventsulation simultaneously fastened to the deck with Ultrafast Fasteners and Metal Plates spaced 9" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. Ply Sheet: p �o or more plies of JM APP Banc or a iea we ed to base sheet while maintaining 4" side laps and 6" end laps. Membrane: One or more plies of APPeX 4.5M or.APPeX 4.5M FR heat welded while maintaining 4" side laps and 6" end laps. Surfacing: (Optional) Install one of the following for all systems that do not achieve acceptable fire ratings through the use of FR membrane sheets. Any coating, listed below, used as a surfacing, must be listed within a current NOA. 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at a rate of 60 lb./sq. 2. Karnak 97, Karnak 97 AF, Monsey Premium Long Life Aluminum Roof Coating Asbestos Free or Monsey Prograde Aluminum, Grundy AL MB aluminum coating at a rate of 1-1/2 gal./sq. Monsey Aquabrite, Gardner asphalt emulsion, APOC Sunbright 400 or Henry 229 Aluminum Emulsion at 2'/2 gal./sq. or APOC 212 Aluminum Roof Coating at 3 gal./sq. 3. Grundy 20 F asphalt emulsion, Endure Asphalti Emulsion, APOC 302 or 302 AF applied at 2'/2 gal./sq. with optional. 60 lbs./sq. of roofing granules embedded in wet coating. Maximum Design Pressure: —52.5 psf. (See General Limitation #7.) NOA No.: 16-0413.06 Expiration Date: 06/14/21 Approval Date: 06/02/16 Page 14 of 15 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of. 2040 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. if no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one'at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 ibf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the .fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application. Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced. uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 16-0413.06 MIAMI•DADECOUMY Expiration Date: 06/14/21 Approval Date: 06/02/16 Page 1.5 of 15 MIAMNGADE MIAMI-DADS COUNTY UNUM PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE: ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www,miamidade.eov/cconomv Johns Manville Corporation 717 17th Street Denver, CO 80202 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of constriction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Johns Manville APP Modified Bitumen Roofing Systems Over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: ".Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The.NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A. copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 13-0529.02 and consists of pages 1 through 15. The submitted documentation was reviewed by Jorge L. Acebo. APPR4YED NOA No.: 16-0413.06 Expiration Date: 06/14/21 Approval Date: 06102/1.6 Page 1 of 15 ROOFING SYSTEM APPROVAL Category:, Roofing Sub -Category: Modified Bitumen Materials: APP/SBS Deck Type: Wood Maximum Design Pressure: -82.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLET Product JM APP Base APPeX 4S APPeX 4.5M APPeX 4.5M FR Tricor M FR Tricor M FR CR Tricor S PeimaPly 28 Ventsulation G1asBase Plus DynaFast 180 S DynaFast 180 HW DynaFast 250 HW Test Dimensions Specification 39-3/8" x 48' 10" ASTM D6509 39-3/8" x 32' 10" ' ASTM D6222 Type I Grade S 39-3/8" x 32' 10" ASTM D6222 Type I Grade G 39-3/8" x 32' 10" ASTM D6222 Type I Grade G 39-3/8" x 34' l" ASTM D6223 39-3/8" x 34' 1" ASTM D6223 39-3/8" x 32' 10" ASTM..D6223 36" x 106' ASTM D4601 36" x 36' ASTM D4897 Type II 36" x 106' ASTM D4601 39-3/8" x 49'2" ASTM D6164 39-3/8" x 49'2" ASTM D6164 39-3/8" x 32' 10" ASTM D6164 Product Description APP modified asphalt, fiberglass reinforced, smooth surfaced base sheet. APP modified asphalt, polyester reinforced, smooth surfaced membrane for use as a Base and/or Ply Sheet only. APP modified asphalt, polyester reinforced, mineral surfaced membrane. APP modified asphalt, polyester reinforced, fire -retardant, mineral surfaced membrane. APP modified asphalt, polyester / glass reinforced, granule surfaced membrane. APP modified asphalt, polyester / glass reinforced, coated granule surfaced membrane. APP modified asphalt, polyester / glass reinforced, smooth surfaced membrane for use as a Base and/or Ply Sheet only. Type II asphalt impregnated and coated glass fiber base sheet. Heavy duty fiber glass base sheet impregnated and coated on both sides with asphalt with or without fine mineral stabilizer. Type If SBS and asphalt blend impregnated and coated glass fiber base sheet with fine mineral stabilizer. SBS modified asphalt, polyester reinforced, smooth surfaced sheet. SBS modified asphalt, polyester reinforced, smooth surfaced sheet. SBS modified asphalt, polyester reinforced, smooth surfaced base sheet. NOA No.: 16-0413.06 Expiration Date: 06/14/21 Approval Date: 06/02/16 Page 2 of 15 Test Product Product Dimensions Specification Description DynaWeld 250 S 39-3/8" x 32' 10" . ASTM D6164 SBS modified asphalt, polyester reinforced, Type lI Grade S smooth surfaced sheet. APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer ('With Current NOA) ENRGY 3, ENRGY 3 25 PSI, Polyisocyanurate Insulation. Johns Manville ValuTherm, ValuTherm 25 PSI, R-Panel, R-Panel 25 PSI ENRGY 3 AGF, Polyisocyanurate Insulation with glass Johns Manville ENRGY 3 AGF 25 PSI, reinforced facers. ENRGY 3 CGF, ENRGY 3 CGF 25 PSI, ValuTherm AGF, ValuTherm AGF 25 PSI, ValuTherm CGF, ValuTherm CGF 25 PSI ENRGY 3 FR, Polyisocyanurate Insulation with inorganic Johns Manville ENRGY 3 FR 25 PSI coated glass reinforced facers; bottom face is premium coated for combustible decks. Fesco Foam, DuraFoam Polyisocyanurate Insulation with perlite Johns Manville facer. .Retro-Fit Board, DuraBoard High -density perlite roof insulation. Johns Manville Fesco Board Rigid perlite roof insulation board. Johns Manville Structodek" High Density Fiber High Density Fiber Board. Blue Ridge Fiberboard, Board Roof Insulation Inc. NOA No.: 16-0413.06 ta"i•waae COUNTY Expiration Date: 06/14/21 Approval Date: 06/02/16 Page 3 of 15 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. UltraFast Fasteners Insulation fastener for wood 412 x 8" max. Johns Manville and steel. Length, #3 Phillips head 2. U1traFast 3" Round Metal Galvalume AZ55 steel plate 3" round & Johns Manville Plate or Square Recessed 3" square Metal Plate 3. All Purpose Fastener Insulation fastener for #14 x 24" max. Johns Manville wood, concrete and steel. #3Phillips head 4. High Load Fastener Membrane fastener #15 x 14" max. Johns Manville #3Phillips head 5. High Load Plates Seam plate with reinforcing 2-3/8" round Johns Manville ribs and eyehooks steel plate 6. Polymer Membrane Batten Plastic membrane batten 1" x 250' OMG, Inc. strips. 7. High Load LH 4.15 Large Head fastener for #15 x 14" max. OMG, Inc. steel, wood, or concrete Oversize #3Phillips head 8. APB Plates Steel Seam plate with 2" round Johns Manville reinforcing ribs and barbs. 9. Trufast. Deep Well Coiled Galvalume coated steel 1" x 100' coil Altenloh, Brink & Batten Bar membrane batten. Co. U.S., Inc. NOA No.: 16-0413.06 Expiration Date: 06/14/21 Approval Date: 06/02/16 Page 4 of 15 EVIDENCE SUBMITTED: Test A2encv Test Identifier Description Date Factory Mutual Research Corp. J.I.OXOA9.AM 4470 03/25/94 J.1. OW6A2.AM 4470 02/05/93 J.I.OX7A4.AM 4470 08/26/93 J.1.3001482 4470 08/11/98 J.I.3002823 4470 04/01 /99 J.1.3003468 4450 02/02/00 J.1. 3007148 4470 04/19/00 3009499 4470 04/04/01 3011248 4450 11/01/02 3012974 4470 06/03/02 3037540 4450 10/20/10 UL, LLC. R10167 UL 790 05/27/13 Exterior Research & Design, LLC #4361-2.04.97-1 TAS 114(J) 04/15/97 10390A.12.97-1 TAS 114(J) 12/15/97 10390A.1.0.97-1 TAS 1.1.4(J) 10/15/97 10391.01.03 TAS 114(J) 01/29/03 Trinity ( ERD J45020.05.13-1 TAS 114(C) 05/16/.13 PRI. Construction Materials, LLC JMC-053-02-01 ASTM. D5147/136222 05/01/13 JMC-054-02-01 ASTM D5147/136223 06/04/12 JMC-055-02-01 ASTM D6509 05/29/12 JMC-070-02-01 ASTM D2178 TYPE IV 04/17/12 JMC-071-02-01 ASTM D2178 TYPE VI 04/17/12 JMC-072-02-02 ASTM D4601 06/04/12 J.MC-074-02-01 ASTM D4897 04/17/12 JMC-075-02-04.2 ASTM D6164 12/27/ 13 JMC-093-02-01 ASTM D4601 08/02/12 JMC-113-02-01 ASTM D6164 04/19/13 JMC-106-02-01 ASTM D6164 04/15/13 JMC-107-02-01. Rev 4 ASTM D903/D1876/D5147 1.1/01/13 TAS 117(B) & 117(A) TAS 114(C) JMC-118-02-02 TAS 114(J) 04/19/13 JMC-126-02-01 TAS 114(J) 04/17/13 JM.C-141-02-01 TAS 114(J) 04/18/13 JMC-167-02-01 TAS 114(C) 08/05/13 NOA No.: 16-0413.06 CMLAM�I-DADEC Expiration Date: 06/14/21 Approval Date: 06/02/16 Page 5 of 15 6/16/2016 TGFU.R10167- Roofing Systems 3 Deck: C-15/32 Incline: 1/2 Insulation (Optional): — One or more layers 1/2 in. "Petro -Fit", "Fesco" or "DuraBoard", "Fesco-Foam", "Fiber -Glass Roof Insulation" or 2 in. min thickness of "ENRGY 30" insulation, mechanically fastened or adhered with "MBR Cold Application Adhesive". All insulation joints offset from plywood deck joints, 6 in. min. Base Sheet: — Two plies Type G2, "PermaPly 28", "GlasBase" or "DibiGlass Base", mechanically fastened or hot mopped. Membrane: — "APPex 4.5M FR", "Dibiten Poly 4.5 FR", (modified bitumen), heat welded. 39. Deck: NC Incline: 1/2 Insulation: — "ENRGY 30" insulation, 2.3 in. thick, mechanically fastened. Insulation: — 1/2 in. "Retro-Fit Board", mechanically fastened. Ply Sheet: — Two or more plies "GlasPly 4IV", hot mopped. Membrane: — One or more plies "APPex 4.5 M", heat applied. Coating: — Karnak "#97", 1-1/2 gal/sq. 40. Deck: NC Incline: 1/2 Base Sheet: — One ply "Ventsulation", hot mopped. Insulation: — "ENRGY 30" insulation, 3 in. thick, mechanically fastened. Insulation: — 1/2 in. "Retro-Fit Board", mechanically fastened. Ply Sheet: — Two or more plies "GlasPly 4IV", hot mopped. Base Sheet: — " JM APP Base", heat applied. Membrane: — One or more plies "APPex 4.5M FR", "Dibiten Poly 4.5 FR", heat applied, 41. Deck: C-15/32 Incline: 1/2 Insulation: — One or more layers 3/4 in. min. "DuraBoard", over (optional) "Fesco", any thickness, mechanically fastened. All insulation joints offset from plywood deck joints, 6 in. min. Base Sheet: — One or more plies "APPeX 4S", heat welded, or Type G2, "PermaPly 28", "GlasBase" or "DibiGlass Base", mechanically fastened or hot mopped. Membrane: — "APPex 4.5M FIR", "Dibiten. Poly 4,5 FR", (modified bitumen), heat welded. 42. Deck: C-15/32 Incline: 1/2 Base Sheet: — One or more plies "JM BaseGrip SD/SA", self -adhered, or Type G2, "PermaPly 28", mechanically fastened. Insulation (Optional): — One or more layers, any thickness, "Fesco" or "Duraboard", "Fesco-Foam", "ENRGY 30" or any UL Classified polyisocyanurate insulation, in combination (optional) with 1/2 in. "Retro-Fit" cover board, mechanically fastened or hot mopped. Base Sheet: — "DynaGrip Base SD/SA", "JM CleanBond SD/SA" or "JM BaseGrip SD/SA", self -adhered. Membrane: — "APPeX 4.5M FR", "Dibiten Poly 4.5 FR", (modified bitumen), heat welded. 43. Deck: C-15/32 Incline: 1/2 Barrier Board: — Min. 1/4 in. thick United Stated Gypsum Co. SECUROCKO Gypsum -Fiber Roof Board (Type FRX-G), mechanically fastened or fully adhered. Insulation (Optional): — One or more layers, any thickness, "Fesco" or "Duraboard", "Fesco-Foam", "ENRGY 30" or any UL Classified polyisocyanurate insulation, in combination (optional) with 1/2 in. "Retro-Fit" cover board, mechanically fastened or hot mopped. Base Sheet: — "DynaGrip Base SD/SA", "JM CleanBond SD/SA" or "JM BaseGrip SD/SA", self -adhered. Membrane: — "APPeX 4.5M FR", "Dibiten Poly 4.5 FR", (modified bitumen), heat welded. 44. Deck: NC Incline: 1/2 Base Sheet: — "JM APP Base Plus", mechanically fastened. Insulation: — One or more layers, any thickness, "Fesco" or "Duraboard", "Fesco-Foam", "ENRGY 30" or any UL Classified polyisocyanurate insulation, in combination (optional) with 1/2 in. "Retro-Fit" cover board, mechanically fastened or hot mopped. Barrier Board: — Min. 1/4 in. thick United Stated Gypsum Co. SECUROCKO Gypsum -Fiber Roof Board (Type FRX-G), mechanically fastened or fully adhered. Base Sheet: — "Tricor S", heat welded. Membrane: — "Tricor M FR", heat welded. 45. Deck: NC Incline: 1/2 Insulation (Optional): — One or more layers, any thickness, "Fesco" or "Duraboard", "Fesco-Foam", "ENRGY 30" or any UL Classified polyisocyanurate insulation, in combination (optional) with 1/2 in. "Retro-Fit" cover board, mechanically fastened or hot mopped. Base Sheet: — "DynaGrip Base SD/SA", "JM CleanBond SD/SA" or "JM BaseGrip SD/SA", self -adhered. Membrane: — "APPeX 4.5M FR", "Dibiten Poly 4.5 FIR", (modified bitumen), heat welded. 1. Deck: C-15/32 Class B Incline: 1/4 Insulation: — "Fiber Glass Roof Insulation", 1-1/2 in. or any UL Classified glass fiber, 1-1/2 in. Base Sheet: — Type G2, "GlasBase". Membrane: — "APPeX 4S", "APPeX 4.5M", "Roof Defender APP Cap Sheet", "APPeX 4.5M FR", "Bicor S", "Tricor S", "APPex 55", "APPeX 180", "Dibiten Poly/4", "Dibiten Poly/5", "Dibiten Poly/4.5 Granular", "Dibiten Poly 4.5 FR". Surfacing: — Karnak "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" or "Karnak No. 97 AF Aluminum Roof Coating" at 2 gal/sq. http://database.ui.com/cgi-bin/XYI//templatelUSEXTI1FRAM Elshowpage.html?name=TGFU.R 10167&ccnshorttitie=Roofing+Systems&objid=1074352094&c... 33159 � MIAMi-DADECOtiNTY MIA1"'tl' PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC; RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION • T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.utiamid.tde.sov/ccononry GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AIIJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or nktterial within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane lone of the Florida Building Code. DESCRIPTION: GAF Timberline HY11, Timberline Natural Shadow', Timberline' American Harvest'', and FortitudCm Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL, of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically tenninatc this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, .Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA # 14-1022.20 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. MIAMIDADE APPROVER NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 1 of 6 r—� ROOFING ASSEMBLY APPROVAL Category: hoofing Sub -Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE ']'his approves GAF Timberline I:LD`"', Timberlines Natural Shadow', Timberline American' Harvest'', and Fortitude''" Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT .DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HD* 13 '14"x 39'/8" TAS 110 Fiberglass reinforced heavy weight asphalt lWanaafcacturing roof shingle, with a laminate profile Locations #1, 2, 3, 4, 5, 6, 7 GAF Timberline Natural 13 '/.i' x 39 Yx" TAS 110 Fiberglass reinforced heavy weight asphalt Shadow* roof shingle, with a laminate profile Manufacturing Locations #1, 2, 3, 4, 5, 6, 7 GAF Timberline'k� American 13 '/a " x 39 ;/s TAS 110 Fiberglass reinforced heavy weight asphalt Harvest') roof shingle, with a laminate profile MantrfactIIring- Locations #2, 4, 5, 6 GAF Fortitude's"' 13 '/4" x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Alanuf teturing roof shingle, with a laminate profile Locations #1, 4 MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City. IN 3. Baltimore, MD 4. Myerstowli, PA 5. I.nnis, 'I'X 6. "Tuscaloosa, Al. 7. Dallas, TX NOA No.: 16-0811.11 MIAMI-DADE COUNITYM Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 2 of 6 EVIDENCE SUBMITTED Test Aeency Test Identifier Test Name/Report Date Underwriters Lahoratories,LLC ASTM D3462 4787344101 07/25/16 Underwriters Laboratories, inc. ASTM D3462 I ICA48924 10/24/11 Underwriters Laboratories, Inc ASTM D3462 IOCA21994 04/22/11 Underwriters Laboratories, inc ASTM D3462 1OCA28717 07/26/1 1 Underwriters Laboratories, inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories, :Inc. ASTM D3462 06CA31580 1.1/30/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 11/021/05 Underwriters Laboratories, Inc. ASTM D3462 06NK05.159 08/09/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41.809 08/11/02 Underwriters Laboratories, Inc. ASTM. D3462 03NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories. inc. TAS 107 OINK.45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories, Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories, Inc. TAS 107 02NK41811 11/I 1/02 Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories, Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRi Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies, Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies, inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 GAF -I 16-02-02 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/ 15/02 F,L.K-085-02-01 10/ 14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21 /02 EL,K-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAMI•DADE COUNTY NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 3 of 6 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 1.15. 2. Plashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail'B', attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. QMIAMIDADE=OUN ENOA No.: 16-0811.11 • •e Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 4 of 6 DETAIL A COIJ.RSE LAYOUT NOA No.: 16-0811.11 MIAMI-DADECouNTY Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 5 of 6 DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-3/811 (1 m) 14-1/2"-17-1/2" 14-1/2"-17-1/2" --► (368-445rmn) (368-445mm) 6-1/2" - 9-1/2" 6-1/2" - 9-1/2" ail guide line (337r 13 n,; (146mm - 159mm) 1a -2-a — � — — "— from bottom of shingle —7�— ru-s4 Self seal adhesive on back ENHANCED NAILING PATTERN - six nails per shingle* required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm) from bottom of of shingle, above the out outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE NOA No.: 16-0811.11 MIAMI-DADE COUNTY Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 6 of 6 fu�.C�J p l A I FWZ,R21 - F'rcpGrred Roof -covering Materials Pp eQm 4FWZ.R2i Prepared Roof -covering Materials Prepared Roof -covering Materials �:,e�,G%nc_,raf„[nform<�kign ter ('repare(1 Rrnf-rnuc�rin hakt:rials GAF 1 'AMPUS DR PAf SIPPANY, NJ 07054 USA RZI Asphalt glass fiber mat shingles - "Royal Sovereign@', "Sentinel µ, ASTM D3462", "Trmbedme,� HD", "Timberline@ Natural 5h xiow" "1 nrhe_rllne!p: Ulm+ tID'" "Tirnbedlne:lO Cool Series", "I imberlint i tr Majestic_`, "Timberline,�O Majestic 30" „TiTnberlineO American Harve' t " "Fortitude''"" . rimborbnr=0 ArmorShleld"! 11", "Grand Timberllne<W" "MarqutsO WeatherMa:i+r@" "Grand Canyon'"" "Grand Sequora(r ", "Grant) Sequoia(.r, IR", "Camelotrg), 'Camelatrg; 11" Tapstone;&`, "Country Mansioni-D,", „Country Mansion(! 11", "Grand Slate'"" . Grand Slate"' it" "SlatelinerRh" "Wood lond(p) ", "Monaco —I!, "Srehn +�)" and 'Glenwood""' lot• installation as Class A prepared roof covering. Suitable. tor" installation on minimum 3/e-in. thick plywood roof decks in combination with minimum one ply "Shingle -Mate" or type 15 or Type 30 underlayment. Also Classified in accordance with AS1M D3161, Class F. Also Classified in accurdance with ASTM o3462/03462M. Also Classified in accordance with [CC ES AC438. Asphalt glass fiber mat shingles - "WeatIrer5lorker Starter Strip Shingles", and "Pro -Start'" Starter Strip Shingles" for installation as Class A roof covering. Suitable for installation on minitnurn 3/8-in. thick plywood in combination with minimum one ply "Shingle -Mate" or Type 15 or Type„ 30 ulid rlayrrient. Also Classified rn accordance with AFTM D3161/G3161M, Class A. Also Classified in accordance with ASTM D3462/D3462M, Asphalt glass fiber mat shingles- "Royal 5overeign(q�", "Sentinetta}", "Timberlinev)3 HD" "Ttmberlinegi Natural Shadow", "TimberhneC?7 Ultra HD" "Tintberlineeiv Cool Series" "American harvest", "Fortitude—", "MarqulsGa WeatherMax(t4", "Grand Canyon"", 'Grand SequolaCk" "Grand Segtwia(g) IR", and "Camelot0" for installation as Class A prepared roof covering when used with minimum Type 30 underlayment over existing wood Shingle roof. Asphalt glass mat hip and ridge shingles- "Timbeartex Hip and Ridge" for installation as Class A prepared roof covering. Also been evaluated ;n accordance with ASTM 113161/03161M, Class F" when Henkel "PL Roofing and Flashing Sealant" or Sorneborn "NP1 Gun -Gracie Polyurethane Sealant" is; applied as specified in manufact:urer's application Instructions." Also Classified in accordance with ASTM 03462/D3462M. Ridge" for installation as Class A prepared roof coverings. "Seal-A«Ridge@ ArrnorShieid"" and "Seal-A-RrdgeC) iR" for installation as Class A prepared roof coverings. Also been evaluated In accordance with ASTM 03161/O3161M, Class A. Also Classified in accordance with ASTM D3462/03462M. "Seal-A-RrdgioQ0" for installation as Class A prepared root coverings. Also been evaluated in accordance with ASTM D3161/D316.1M, Class F when Henkel Corp. "Loctite Pl- S30 Roof & Flashing Sealant" is applied as specified in manufacturer's application instructions. Also Classified in accordance with ASTM D3462/D3462M. isi t Updated on 2016-05-18 rts ions? Print this ocaoe 'terms of USpPage T612 (D2016ULLLC The appearance of a company's name or product. in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product., 01, permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide information, Assemblies, Constructions, oesigns, Systems, and/or Certification,, (files) must be presented in their entirety and in a non- ni*leadmg manner, without any manipulation of the data (ol' drawings). 21. The statement "Reprinted from the Online Certifications Directory with permission from UI," must appear adjacent to the extracted material. In addition, the reprinted material must include a Copyright notice in the following format: "(c,� 2016 UL LI,C,". hltpt!datal ase.ut.coxniagi-birrrXYVfterrtpiateli,ISFXT11FRAMEistirwpage.htmi?name=,rFW ,R2.1&crrrstuartbtlr,--Prep, reds-Roof-ravering+Material$&objid=10.,- 1/1