Loading...
HomeMy WebLinkAboutSite Specific Floor Plana 0 SITE SPECIFIC FLOOR PLAN: SCALE: N.T.S. UNIT #305 BUILDING FOOTPRINT PLAN VIEW UNIT NEXT FLOOR PLAN AND UNIT LAYOUT )I ($ - DDsgj . _T N � 170.0' _ RIECEIVELP NOV 14 2017 DESIGN NOTES: FLORIDA BUILDING CODE FIFTH EDITION (2014) ASCE 7-10 ���11 I 1111 Vult=170 MPH / Vasd=131.7 MPH (3 SECOND GUST), EXPOSURE'D', ENCLOSED S* M. RISK CATEGORY=II, Kd=0.85, Kzt=1.0, KZ=TABLE 30.3-1, GCpi=+/-0.18 �, �� . LICE qh = 0.00256*Kz*Kzt*Kd*V*V P = qh ((GCp)-(GCpi)) C� .. MRH=140', ZONES) AS NOTED, ROOF TYPE 'MONOSLOPE', ROOF SLOPE 0.0° = * ; • NO PE8 PRESSURES: NOTED BELOW INSTALL ALL SYSTEMS PER VALID FLORIDA PRODUCT APPROVALS = -u GENERAL NOTES: O'� •'• STATE OF 1.. THIS ENGINEERED PLAN IS INTENDED TO PROVIDE SITE -SPECIFIC DESIGN PRESSURES FOR 11ER1 OF THE INSTALLATION OF AMFUq STRUCTURE FOR THE PURPOSE GLAZED/NON-GLAZED PRODUCTS A! ED•�W PROVIDED BY OTHERS. NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IS OFFERED AS OR APPLICABILITY OF ANY PROPOSED SYSTEM OR COMPONENT USED ALONG WITH THESE PRESSUI��S� PRODUCT AND APPROVAL INFORMATION IS SPECIFICALLY REFERENCED AND ADDRESSED HEREIN. / ! 1 1 I 1 11' 2. NO CERTIFICATION OR REVIEW IS OFFERED THAT THE PROPOSED UNITS MEET ANY EGRESS REQUIREMENTS. ALL EGRESS ISSUES ARE TO BE ADDRESSED BY THE PERMITTING CONTRACTOR AND THE LOCAL BUILDING OFFICIAL. 3. THE HOST STRUCTURE IS ASSUMED TO BE ADEQUATE TO WITHSTAND THE LOADS IMPOSED BY THIS DESIGN AS WORK REPLACES THE EXISTING FRAMING. IF ANY DEFICIENCIES ARE FOUND IN THE EXISTING HOST STRUCTURE, THIS ENGINEER SHALL BE NOTIFIED BEFORE CONTINUING CONSTRUCTION AND RESERVES THE RIGHT TO RE -INSPECT AND RE-EVALUATE DESIGN. NO WARRANTY, EITHER EXPRESSED OR IMPLIED, IS CONTAINED HEREIN. SINCE IT IS NOT PRUDENT TO PERFORM DESTRUCTIVE TESTING AT THIS TIME, THE CONTRACTOR SHALL VERIFY DURING CONSTRUCTION THAT THE SUBSTRATE IS OF THE TYPE AND CONSTRUCTION THAT IS IN CONFORMANCE WITH THE INTENT OF THE PRODUCT APPROVAL BEING UTILIZED WHICH MUST BE SOUND FOR INSTALLATION OF THIS SYSTEM AND SHALL NOTIFY THIS ENGINEER IF ANY DEFICIENCIES OR ABNORMALITIES ARE OBSERVED. USE OF THIS DOCUMENT CONSTITUTES ACCEPTANCE OF THESE TERMS. 4. SYSTEMS SHALL BE AS NOTED HEREIN. ALL REFERENCES TO EXTRUSIONS & INSTALLATION SHALL CONFORM TO THAT OF MANUFACTURER'S SPECIFICATIONS AS SUMMARIZED HEREIN. S. ANY JUNCTURE OF EXTERIOR PLASTER AND FENESTRATION PRODUCTS SHALL BE SEALED WITH A SEALANT COMPLYING WITH AAMA 800 AND ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, AND ASTM C1281 OR AAMA 812 FOR THE TYPE OF SEALANT TO BE SELECTED WHICH IS OUTSIDE THE SCOPE OF THIS CERTIFICATION. 6. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 7. ALL CONCRETE SHALL BE UNCRACKED ONLY WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI U.N.O. AND SHALL BE MINIMUM 1.5X THICKER THAN ANY MEMBER EMBEDMENT. ALL EPDXY AND GROUT SHALL MEET OR ., EXCEED COMPRESSIVE STRENGTH OF THE CONCRETE AND SHALL BE IRON -FREE, NON -SHRINK AND NON -REACTIVE. 8. FOR ALUMINUM ATTACHMENTS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND 2.5xDIAMETER MIN SPACING TO ADJACENT ANCHORS, UNLESS NOTED OTHERWISE. 9. ALL FASTENERS TO BE #12 X 3/4" OR GREATER 2024-T4, 18-8 SERIES 300 NON-MAGNETIC STAINLESS STEEL, OR CADMIUM PLATED OR OTHERWISE CORROSION RESISTANT MATERIAL AND SHALL COMPLY WITH 3.3.1, SPECIFICATIONS FOR ALUM. STRUCTURES -SECTION 1, THE ALUMINUM ASSOCIATION,INC., & APPLICABLE FEDERAL,STATE, AND LOCAL CODES. 10. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, TO THE EXTENT THAT THE OPENING AREA IS NOT SMALLER THAN 5% OF THE ENGINEERED DESIGN. CONTRACTOR IS TO VERIFY ALL FIELD DIMENSIONS PRIOR TO INSTALLATION. 11. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 12. ENGINEERING EXPRESS HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE UNIT OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY NEXT TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. 13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. �] OO R * ALTERATIONS, ADDITIONS, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION * DESIGN INFORMATION: MARK QTY W x H (in.) ZONE DESIGN PRODUCT PRODUCT MODEL PRESSURE (psf) APPROVAL # 1 (1) 71.00 x 95.00 4 +46.31 / -59.05 15-1210.02 SERIES 5470 VINYL SLIDING GLASS DOOR 2 (1) 180.00 x 95.00 4 +42.51./ -55.77 15-1210.02 SERIES 5470 VINYL SLIDING GLASS DOOR 3 (1) 53.00 x 64.00 4 +49.12 / -61.47 16-0714.04 SERIES 5400 PVC SINGLE HUNG WINDOW 4 (1) 53.00 x 64.00 4 +49.12 / -61.47 16-0714.04 SERIES 5400 PVC SINGLE HUNG WINDOW DRAWING NOTES: , • ALTERATIONS LEVEL: THIS SHEET IS INTENDED FOR USE IN PROJECTS WITH LEVEL OF ALTERA O L F OF AL DI R , THIS p ENGINEER CONTACTED FOR ADDflTONALCERTIFICATION. a l- "r =- ` • DOOR DESIGNATIONS: ANY DOOR PRODUCT SHALL EXIT ONLY TO EXISTING BALCONIES WITH EXISTING�.4?af}ICiHRPPROVED G ARDS WHICH SHALL NOT BE MODIFIED. • SILL HEIGHTS: WINDOWS MUST HAVE MINIMUM SILL HEIGHT OF 24 INCHES. OPERABLE WINDOWS WITH SILL HEIGHTS LOWER THAN 42 INCHES THAT DO NOT OPEN TOA BALCONY AREA WITH AN APPROVED GUARDRAIL SHALL BE EQUIPPED WITH A PERMANENT BLOCKER WHICH PROHIBITS THE WINDOW FROM OPENING TO WHICH A 4" SPHERE CAN PASS THROUGH AT ANY POINT BELOW 36" (EXCEPT FOR RESCUE WINDOWS WHICH IN THE EVENT OF AN EMERGENCY THE BLOCKER MUST BE REMOVABLE). WINDOWS WITH THIS CONFIGURATION SHALL ALSO HAVE SEPARATE CERTIFICATION CONFORMING TO FBC FOR SAFEGUARDS WHICH IS NOT INCLUDED IN THIS DOCUMENT. • WHEN APPLICABLE, WIND PRESSURE INFORMATION FOR LISTED SHUTTER PRODUCTS HAVE BEEN CALCULATED USING WIDTH - HEIGHT / 3 (EFFECTIVE AREA = H•H/3) FRANK L BENNARDO P.E. PE* PE00"549 i �017 rEa®i� ►f�rTEULseeaw 0 b , P.E. vj �L N Z •. d � V o ♦ W ('E1 ,•, LJ i in V � 1-4 OD LL W �a rn LL� N q6LU o ="d Z� UI IL F>QLLWWa haw Z�omm ZZo WW Onj_j,cnnLuWU CJ Wog LL N W �=w O UJ wo ri V z H J z J CA Lu a o Lu LL OQN OLu U) DC ^UI^ a N v U) M U) g c� W iEMS AN Hal COPYRIGHT ENGINEERING EXPRESS 17-5088 SCALE: N.T.S. OF N