Loading...
HomeMy WebLinkAboutDrawingInstall ne VAC System. It shall be minimum 16~ R Energy Star Rated } TRANE or equivalent brand, electric heating and air conditioning system 1 HVAC with service to all habitable rooms. Repair any leaky duct work and correctly support duct work above the insulation. Replace air handler, piping, electrical, new vents and all other items necessary for a complete system. • Replace exterior light fixtures with energy star fixtures. • Removal or disconnect electric wall mounted heater— refer to page 21 of the Property Inspection Report located on SLC Portal. • Replacement of existing smoke detectors and upgrade to installation in accordance with current standards and codes. • Replace the light fixture in the bathroom over the sink. • Replace any receptacle that has been painted over. • Cap off exposed electrical wiring at the West wall in the Kitchen — refer to page 27 of the Property Inspection Report located on the SLC Portal. • Preform a de -rating on the electrical cable/conductors running through 2 Electrical the conduit above the circuit breaker panel refer to pages 27 & 28 on the Property Inspection Report located on the SLC Portal. • Inspect the Circuit breaker panel and the electric service equipment panel cover. Repair/Replace if necessary — refer to page 28 of the Property Inspection Report on the SLC Portal. • Correctly protect "Romex" and electric cable -North side of the house from damage — refer to pages 29, 30, 31 & 32 of the Property Inspection Report located on the SLC Portal. • Install GFCI receptacle outlets in all wet areas, if not in place. • Correctly support low voltage electrical cable above the flat roof deck — refer to page 32 on the Property Inspection Report located on the SLC Portal. • Connect washer machine waste water to septic system - refer to pages 14 & 33 of the Property Inspection Report on SLC Portal. • Replace water heater with electric water heater — refer to Spec Book 3 Plumbing located on the SLC Portal. • Repair/replace the damaged plumbing supply shut off valve for the washing machine. • Replace toilet in full bathroom with an ADA toilet. Y.4=¢I C-1 Sfi• 6. 8 Z ' a Yell s } r- r • Replace faucet in the bathroom vanity sink in the full bathroom — refer to page 34 of the Property Inspection Report located on the SLC Portal. • Install new drain waste pipe in the lavatory sink in the half bath — refer to page 35 of the Property Inspection Report located on the SLC Portal. ! • Install a handle on the hose Bibb faucets on the exterior of the home. • Replace exposed cast iron plumbing drain waste piping to septic tank at s i the back of the house— refer to page 35 on the Property Inspection Report located on the SLC Portal. • Repair plumbing pipes under kitchen sink, leaking issue. • Replace kitchen sink faucet. 4 Painting Repair and paint, if needed, any areas that have been disturbed by your work. Match as closely as possible. Replace exterior doors with Hurricane impact approved doors. Deadbolt 5 Doors shall be keyed alike. Windows Replace windows with new Energy Star labeled regular windows. Owner 6 and has shutters. Verify homeowner has proper amount of shutter to cover all shutters openings. • Replace flat roof covering. Replace deteriorated roof decking and support members where needed — refer to page 5 of the Property I Inspection Report on SLC Portal. Figure 3 sheets of decking and PROVIDE A PER SHEET PRICE. • Install gutter only where required by the Health Department. • Replace soffits and replace screen attic vent openings where needed with either screen or wire mesh refer to page 11 of the Property 7 Roof Inspection Report on SLC Portal. • Repair/replace fascia board where needed— refer to page 6 and 10 of the Property Inspection Report on SLC Portal. • Add additional fasteners and seal the current ones on the roof attic ridge vent and seal exposed roof shingle fasteners/nails at sloped roof - refer to page 7 of the Property Inspection Report on SLC Portal. • Repair/Replace, remediate mold in utility room ceiling — refer to page 6 of the Property Inspection Report on SLC Portal. • Repair the damage to the finish at the ceiling in the kitchen, living room and wall under the window in the bathroom — refer to page 6 and 22 of the Property Inspection Report on SLC Portal. • Seal crack in masonry' block wall to the right of the front entryway door, 8 Misc. Northwest corner of the building and properly seal openings around all utility penetrations — refer to pages 9, 10 and 12 of the Property Inspection Report on the SLC Portal. • Repair dry wood damaged beam at the Northwest corner of the carport refer to page 13 of the Inspection Report on SL'C Portal. • Replace dryer vent at the dryer exhaust vent terminal. • Demo and remove shed. Shed presents a wind borne debris hazard during a storm. • Have home checked for termites and treat as necessary. • Repair the door that is sticking between the kitchen & utility room. • Repair the concrete driveway where it is a trip hazard — refer to page 25 of the Property Inspection Report located on the SLC Portal. z C • Replace tile surround of tub — refer to page 33 of the Property Inspection Report located on the SLC Portal. • Repair window opening where cut out for window installation — refer to page 37 of the Property Inspection Report on SLC Portal. • Repair the bottom of the cabinet under the sink due to leaking issues. • Install missing fence post and ensure the fence is securely fastened in place — refer to pages 38 & 39 of the Property Inspection Report located on the SLC Portal. • Property secure mailbox and stand into ground. • Have carpet cleaned and tack down any loose threshold areas. • Pump septic tank • Contractor to provide Uniform Wind Mitigation Jennifer Hance I Housing Program Specialist I Community Services 437 North 7t1i Street, Fort Pierce, FL 34950 1): 772-462-2376 1 F: 772-462-2855 1 E: hanccj@stlucieco.org facebook.com./StLucieGov I mutter..com/StI:..ucieGGov I voutube.co.ni./StLucieGov `i Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records 'available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. It ',�'6 Im GENERAL CONTRACTORS GENTII CORP. P, GG0 1 521 5'06 TO: REF: DATE: 0 kc ■■■ems �� WA, rAkl-,. =3 0 1 . m I Z.'/ I v t) PHONE: 954.520.054B 772.342.692E3 r.E:NTILELLC@r-om CAST. NET