Loading...
HomeMy WebLinkAboutSwimming Pool Specificationsn. RA A r9h �'4'1`080RA-ITACHMEjI ARE THS00NSIBUTY OF THE CON tpl-1 .,4 0 TOR OF psconD / �A_ rn. . I , Wiz. . TDH BEAM (-1 91) BRANCH: 3". T DIG + HAUL RUNK: 2.5" RETURN:2" 33+ THESE PLANS NS AND ALL PROPOSED WORK ARE SI&EM"TO ANNY E, 0 U I A rl 0 F) l F I E. L 0 1 NO PE (,rCdg TW MAY 13E NXESSARYIN C00EN TO COMPLY WITH ALL APPLICAULE 00004, OWNER TO REMOVE -TREE... -40 ...... IF ;a . . . . . . . sl ECOSYSTEM 3 WALL 6'D SPA 87 RETURNS 13 -2' RISERS 1/2" WHITE JETS U rBUB6BLER 4 �-29181?' z . . BR U U '4" SLEEVE LA�.M V C LEE E XD SIP ST L.U­E COUNTY YAC rvo BUILL)!NG DIVISION n. E v i p: w E,: 5, DIV ISION CO UNTY N T 0 Y N 17012 COAPPL lor. 7 7 REVIEWED'E.Y• jrz= DATE OR PERMIT IT lrND PERMIT joa OWNER TO INSTALL BARRIER FENCE AND MUST �---�ZXCPT ON J08 OF1 NO 1 N 81 ti 7 1; JILL Be M�� 0- -N WILL- DEVADS ATTACH APPLICATION TO A —PS PERMITT :'SEPTIC:. HO-ROS=l 7153'.wE POOL SPECS POOL PERIMETER: POOL AREA: POOL STEPS: TOTAL P/D AREA: DECK PERIMETER: TOTAL DECK AREA: COPING: PAVER AREA: DECK DRAIN: AMERICAN POOLS &. SPAS . 7320 Narcobssee Rd. Orlando, FL 32822 Office: 40.7-847-9322 Fax: 407--847-9342 82.5 LF 397 SF 42 LF 880 SF 124 LF 483SF 82.5LF 56SF_ SCALE: 1/87 = 1 -0" JOB HISTORY JOB# HO-ROS-17153-E ORIG DRAW DATE: 08,09,2017 CREATED: BOBBY W E.: - BINInfreeRomerican-pooNscom REVISION 01 DATE: 0943-2017 CREATEMBOBBYIN CHANGES: ADDED PI REVISION #2 DATE: CREATED: CHANGES: REVISION #3 DATE: CREATEM. CHANGES: REVISION 04 DATE: CREATED: - CHANGES: REVISION 95 DATE: CREATED: CHANGES: SALES CONSULTANT: KATHLEEN TEL'407-847-8322' E.-- CONSTRUCTION SUPER: CRAIG' TEL: E... POOL POOL SHAPE: CUSTOM. POOL TYPE: GUNITE POOL GAL: 13,400 POOL SIZE: 14'X29'8'. POOL DEPTH: 3'--6' TILE TYPE: 6" X 617 PUMP ONE: PEkTAIRSUPERVLOVS PUMP TWO: NIA FILTER ONE: PENTAIRC+C150SF FILTER TWO: NIA SANITIZER ONE: IC-40 SANITIZER TWO: 'NIA POOL HEATER: NIA VAC LINE: Yes MAIN DRAINS: PENTAIRSTARGUARD' SKIMMER: ISE RETURN LINES: ECO: POOL CLEANER: NIA. - EXTRA SUCTION' NIA CONTROLS: PE35300 POOL LIGHT: COLOR LED EXTRA STEPS: NIA EXTRA BENCH: YES SUNSHELF: YES TERMITE BOND COMPANY: WA PHONE NUMBER: 000-000-0000 DECK, doPlING. I FOOTE . R TYPE ACRYLIC: NIA PAVER: YES- I ACRYLIC: NA PAVER: YES DESCRIPTION: NIA DESCRIPTION: CARMEL MALT "T" DESCRIPTION; CAMEL MALT PATTERN' -BARRIERS CHILD FENCE: - NIA EXISTINGFENCE(Meets Code): NIA ALARMS -BATTERY: NIA OWNER TO INSTALL'FENCING: YES ALARMS -HARD WIRED: 91A APS TO INSTALL FENCING: NIA NO SCREEN COLOR SELECTIONS POOL INTERIOR: BLUE TILE SELECTION: SILVER STONE AQUA MARINE SPA INTERIOR: NIA TILE GROUT: EARTH DECK COLOR: CARMEL MALT STERTILE: SANDSTONE AQUA MARINE' DECK PATTERN: "T" PATTERN SKIMMER COLOR: -WHITE : CAMEL MALT COPING: SKIMMER LID: WHITE COPING GROUT: NIA DRAIN AND FITTINGS: WHITE - SPECIAL: NIA SPECIAL: NIA OPTIONS OPTION: (1) 112"WHITE SUNSHELF BUBBLER OPTION: 1 HP BLOWER OPTION: (2)SPAJETS IN SWIMOUT' OPTION: OPTION: UMBRELLA SLEEVE IN SUNSHELF '' OPTION: OPTION: RlDECK JETS OPTION: 1911- , 0 BUYER NAME(S): DAVID &.CRIiTINA-ROSKO 9-VPAIL' CROSKO-341 @-YAHOO.COM ADDRESS: 5212 PINETREE DRIVE CITY: FORT PIERCE STATE: FL ZIP CODE: 34982 TEL: 772.631.3595 CELL: 000-000-0000 SUBDIVISION: NDiAN RIVER ESTATES - .LOT-#:15&16 PLAT.BOOK:0294 . PAGES 2201 COUNTY: SAINT LUCIE Ul Swimming Pool Energy EMQI-ncy Compliance Information ` Note: These Requirements apply ONLY to the Filtration Pump ANSI / ASPC ! ICC-15 2011 Flow Calculations: Pool water volume 13400 1360 = 37 gpm - this is the calculated flow rate Note: for pools under 13,000 gals. the calculated flow rate or 36 gpm whichever is greater = the filtration flow rate Note: Is there an Auxiliary load on the filtration pump? Fx]Yes a No If so, what is the calculated auxilliary flow rate 36 gpm Flow rate (low speed) 35 gpm @ 1725 rpm Minimum suction side pipe size @ 6 fps 1.5 in. Minimum suction side branch pipe size @ 6 fps 1.5 , in. Minimum return side pipe size @ 8 fps 1.5 in. Minimum return side branch pipe size @ 6 fps 1.5 in. Determine Filter Size: Filter Factors (GPMISF): Fx I Cartridge (0.375) 1-1 D E (2.0) F-1 Sand (15) Filter Size: (F31aw`,Rate) / S ter Fed) _ (�3ime) PENTAIR C+C 150SF (Filer Make and Mode ) Pump Controls: Filtration pump has no auxiliary load- standard time clock F Filtration pump with auxiliary load -Control model for low speed default within 24 hrs Heater Model: )Q( (MBke,Model and S¢e) Gas Heater Efficiency Rating XX (No Pilot Light) Heater Pump Efficiency C.O.P XX ANSI 5 & ANSI 7 Compliance Work Sheet PENT. SUPERFLO VS Determine Simplified TDH: Distance from pool to pump in feet: 20 2. Friction loss (in suction pipe) in 2.5 inch pipe per 1 fL @ 103 gpm = 3' Friction loss (in return pipe) in 2 inch pipe per 1 ft. @ 103 gpm = Determine Simplified TDH (CONTINUED): 4. 20 x .09 = 1.8 (Length or SucL Pipe) (Ft of headrl 8 of Pipe) (TDH suct. Pipe) 5. 20 x .16 = 3.2 (Length of Retum Pipe) (Ft or headll fl of Pipe) (TDH Return Pipe) .09 (from pipe flowlfriction loss chart) • 16 (from pipe flowlfriction loss chart) TDH in Piping: 5 Filter I Heater loss in TDH 7 All other losses 21 Determine Pipe Saes: Branch Piping to be 3 inch to keep velocity@ Trunk, Skimmer & Suction Piping to be 2.5 inch to keep velocity @ Return Piping to be 2 inch to keep velocity @ Pump Selection: as Listed on Curve A or C (circle one) gpm System Flow Rate. 6 fpsimax. at 16 8 fps max. at 103 gpm System Flow Rate. 10 fps max. at 1 103 1 gpm System Flow Rate. Filtration Pump PENT. SUPERFLO VS Maximum Flow Rate 103 gpm Main Drain Cover Determine the Number and Tvpe of Required In -Floor Suction Outlets: t- Check all that apply. ® OO X-08 O 2 PENTAIR SG suction outlets @ O O O 3 suction outlets @ O channel drain @ Total Head In Feet Conversion Chart Inches Mercury (Vacuum Gauge) O 1 2 1 4 6 1 8 10 1 12 1 14 16 1 18 0 0.0 2.3 4.5 6.8 9.0 11.3 13.6 15.8 18.1 20.3 1 2.3 4.6 6.8 &1 11A 13.6. 15.9 18.1 20.4 27-7 2 4.6 6.9 9.1 11A 13.7 15.9 18.2 20.4 22.7 25.0 3 6.9 92 11.5 13J 16.0 182 20.5 22.B 25.0 27.3 4 92 11.5 13.8 16.0 18.3 20.5 22.8 2&1 273 29.6 5 11.5 13.8 1&1 18.3 20.6 22.8 25.1 -27A 29.6 31A 6 13.9 16.1 18.4 20.6 22S 25.2 27A 29.7 31.9 342 7 16.2 18.4 20J 23.0 252 27.5 29.7 32.0 34.3 35.5 8 1&5 20.7 23.0 253 275 29.8 37-0 343 36.6 38A 9 20.8. 23.1 253 27.6 29.B 32.1 34.3 36.6 38.9 41.1 10 23.1 25A 27.6 299 32.1 34A 36.7 38.9 412 43.4 11 25A 27.7 29.9 345 36.7 39.0 412 435 45.8 12 27.7 30.0 32.2 36.8 39.0 41.3 _ 43.5 45.8 48.1 a� 13 30.0 323 34.6 JIA 39.1 413 43.6 452 48.1 50A 14 32.3 34.6 3&9. 41A 43.6 45.9 48.2 56.4 527 �II 15 C9 34.6 36.9 392 43.7 45.9 48.2 50.5 52.7 55.0 y 18 37.0 392 41.5 . 46.0 48.3 50.5 52.8 55.0 573 y 17 39.3 41.5 43.8 4631 48.3 50.6 52.8 55.1 67.4 59.6 18 41.6 43.8 46.1 48.4 50.6 52.9 55.1 57.4 59.7. 612 d 19 43.9 462 48A 50.7 52.9 552 57A 1 59.7 670 1 642 V5 20 462 46.5 50.7 53.0 552 575 59.8 1 67-0 843 1 66.5 IL 21 48.5 50.8 53.0 55.3 57.6 599 62.1 643 66.6 68.9 22 50.8 53.1 553 57.6 59.9 62.1 64A 66.6 68.9 712 23 53.1 55A 57.7 599 622 64.4 66.7 69.0 712 73.5 24 55.4 57.7 60.0 622 64.5 66.7 69.0 71.3 735 75.8 25 57.8 60.0 62.3 64.5 66.8 69.1 713 73.6 75.8 78.1 26 60.1 623 64.6 66.8 1 69.1 71A 73.6 75.9 78.1 BOA 27 624 64.6 66.9 692 1 71.4 73.7 752 7&2 805 82.7 28 64.7 66.9 692 71.5 1 73.7 76.0 782 80.5 82.8 85.0 29 67.0 1 69.3 71.5 73.8 1 76.0 78.3 80.5 B2.8 a5.1 873 30 69.3 1 71.6 73.8 76.1 78.3 80.6 82.9 85.1 87A 89.6 31 71.6 1 73.9 76.1 7&4 80.7 82.9 85.2 87A 89.7 92.0 32 73.9 762 78A 80.7 83.0 852 97.5 89.7 92.0 943 33 762 78.5 80.7 83.0 B53 87.5 89.8 92.0 943 96.6 34 78.5 B0.8 83.1 85.3 87.6 89b 92.1 94.4 96.6 98.9 35 80.9 83.1 BSA 87A 89.9 922 94.4 96.7 982 101.2 PENTAIR STARGUARD (Make end Model) 144 gpm max. flow gpm max. flow gpm w! ports Flow and Friction Loss Per Foot Schedule 40 PVC Pipe VOW*- Feet Per Second I Pipe Sae 6 fps 6 fps 10 fps 1• 16 9prn 0.14' 21 9pm 0.23' 26gpm am 1.61 37 gpm 0.08' 50 gpmnm m 021' 7 62gpm OW 82gpmpm a1v 2.5' B8 pm 0.05, 117 gpmm 0.13' 31 136 gpm 0.04' 181 gpmm 0.10, 4- 234 gpm 013' 313 gpmpm 0.07' 6• 534 am 0.02' 712 gpm TDH Calculation Options or eac 1 pump Check one. SimplifiedTotal Dynamic Head (STDH) Complete STDH Worksheet - Fill In all blanks. Total Dynamic Head (TDH) Complete Program or other calcs. Fill in required blanks on worksheet & attach calculations. Maximum Flow Capacity of the new or replacement pump. tractors Signature contractors Cent. No. o er Total Dynamic Head (TDH): 33.} "NOTE: FIELD TDH MUST BE EQUAL TO OR HIGHER THAN THE CALCULATED TDH. nlractors Telephone No. Scale: None 1. ��. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. GENERAL NOTES For pool plan, size, deck, and special details, see Contractors Pool Plan. Pool Walls shall be 5" thick and Floors shall be 6" thick and shall be pneumatically applied Concrete with a Compressive Strength of 3,000 psi in 28 days. Concrete Decks shall be 2,500 psi. Concrete construction will conform to ACI Standard 318. All Pool design, construction and workmanship shall be in conformity with the requirements of Florida Building Code, 5th Edition, 2014 (FBC) Accessibility; FBC Building; FBC Residential, and; ANSI/NSPI-3, ANSI/APSP/ICC-4, ANSI/APSP/ICC-5;ANSI/APSP/ICC-6 and ANSI/APSP-7; ANSI/APSP-15 and the Adopted National Electric Code 2011 (NEC) and Chapter 42 and Chapter 45 of the 5th Edition of the FBC, Residential. All Pool Piping to be Schedule 40 PVC, bearing the mark of NSF Approval unless otherwise noted. All Reinforcing Steel to conform to ASTM 615, Grade 40. Reinforcing shall be #3 bars at 12" on center in each direction, w/ 15" lap joints in walls and floors up to 6'. Where the pool depth is over 6ft (measured vertically down from the Waterline), use #3 bars at 6" on center in each direction in the areas that exceed 6ft in depth. LENGTH 6" WATER COPING WATER LINE TILES -POOL LINE ,�, 5„ DRAIN COVER/GRATE MUST CONFORM TO STEPS o POOL THE LATEST EDITION m LIGHT OF ANSI/ASME 112.19.8 POOL STEPS: '' RISERS: 12" MAX. SUCTION OUTLET AND APPROVED GRATE DUAL TREAD: 10 MIN. (240 SQ. IN. MIN.) WITH 3'-0" OF SEPARATION CENTER LINE TO CENTER LINE OR APPROVED CHANNEL DRAIN POOL SECTION SET INTO CENTER OF POOLS DEEPEST POINT EEL GRID AT THE (LONGITUDINAL) CONCRETE DECK (OPTIONAL) W/ SLIP RESISTANT TOPPING ON COMPACTED GROUND W/ ALL ORGANIC MATERIAL REMOVED. 4" NOM. THK. W/ FIBER MESH OR 5" NOM. THK. W/ #3 REBARS. If Concrete is cast against Bare Earth without a Separation Barrier, the minimum 1-#3 BAR CONT. IN 5" THK WALL. 4.-0 JUNCTION BOX cover shall be 3". With a Barrier (Steeltex) between Concrete and Earth, the (USE 2-#3 BARS CONT. IN 8"x8"� j (BY OTHERS) minimum cover shall be %". BOND BEAMS) All Metallic Pool Fittings within 5' of the inside wall and deck reinforcing steel to be WATER bonded to the Pool Reinforcing Steel with #8 AWG Copper Wire. The #8 Copper Wire to be run internally and externally with the NEC approved PVC Light Conduit LINE100 z C)z form the Light Niche to the Junction Box. Completion of the pool grounding to the ~ `� Electrical Panel Ground to be by Electrician. Bond all Sheathed Cables Raceways Metal Piping and all Fixed Metal Parts not 00 WATER LINE 14" MIN. N 18" MAX. CO TO TRANSFORMER (BY OTHERS) 2-#3 BARS CONT. IN 8"X8" BOND separated by a permanent barrier, if within 5'-0" Horizontally from Water and MARBLE ; "" `---U.L. APPROVED 120 VAC/300W POOL 12'-0" Vertically of Maximum Water Level. PLASTER LIGHT W/ GFI OR 12V/400W MAX. POOL Equipotential Bonding to be accomplished in accordance with Article 680 of the FINISH LIGHT W/ LOW WATER CUT-OFF IN U.L Adopted National Electrical Code 2011 (NEC). APPROVED GREY PLASTIC FORMING SHELL Pool or Patio shall bear only on Rock or Clean Sand, which shall be compacted to OR APPROVED EQUAL W/ #8 AWG BOND provide a Structurally Safe Bearing Capacity. Any Unsuitable Material encountered in WIRE PER N.E.C. excavation shall be removed in its entirety and the area shall be backfilled with STEELTEX (OPTIONAL) #3 BARS 12" O.C. EACH WAY acceptable material and properly compacted. Where unsuitable Material cannot be ( removed, the pool must be redesigned. POOL STRUCTURAL DETAILS V:.: ` \--UNDISTURBED SOILS `'_ (NO VOIDS) SWIM —OUT DETAIL DECK OVER POUR OR 8 --I BRICK COPING 6" OF-' "-1-#3 BAR WATER CONT. IN 5" LINE THICK BOND TILES BEAM BEAM MIN. 1Y" COVER OVER ALL BARS (SEE NOTE #5) AL TERNA TE BEAM FINISH DETAIL The Contractor must protect Existing Structures from failure by acceptable methods DISTANCE LESS NEW OR if required. The Engineer accepts no responsibility for the safety of Existing THAN 1 ON 1 + 1r/////EXISTINC- VARIES 18 Structures. COPING STRUCTL The Des! n En ineer assumes no res onsibility for ool construction in Easements or SEE SEAT 9 9 P P PLAN Required Setback areas. Pool Contractor and/or Owner shall verify the layout and WATER all dimesions shown prior to construction. LINE Contractor shall determine the location of all Utilities in relation to the Pool and its ° Equipment and ensure minimum clearances in accordance with Local Regulations 5" THERAPY and Ordinances. LINES Contractor shall provide adequate Temporary Fencing around the construction area ° o0 4 to prevent unauthorized entry into the Pool Area. RETURN If a water supply is provided, a minimum 3" Atmospheric Break will be provided. LINES All Structural, Filtration and Electrical details outlined in these drawings also relate GUNTTE to Spa Construction. #3 BARS ® REBOUND 16. All Pool and Spa Heaters shall be equipped with an On/Off Switch mounted for 12" O.C.E.W. (2) 8"0 ANTI -VORTEX easy access to allow the Heater to be Shut Off without adjusting the Thermostat DRAINS SEPARATED BY 3' settings and to allow restarting without relighting the Pilot Light. 17. WARNING! To empty the Pool for any reason, the Hydrostatic Uplift Pressure must SPA STRUCTURAL DETAILS be eliminated. The Owner must consult a Contractor experienced in eliminating Uplift Pressure. 1 MAIN DRAIN LINE 2 SKIMMER LINE 3 WASTE LINE D 3 4 RETURN LINE 5 PRESSURE CLEANING C VE4 LINE (OPTIONAL) A HAIR & LINT STRAINER 5 B B RECIRCULATION PUMP C FILTER A D IN-UNE CHLORINATOR (OPTIONAL) 2 E HEATER (OPTIONAL) FILTER SYSTEM #3 BARS ® 6" O.C. EACH WAY 6" WALL - THICKNESS MARBLE PLASTER FINISH TYPICAL WALL AND FLOOR WITHIN SPILLWAY PER 66 GLASS -BLOCK ANGLE OF REPOSE CONTRACTORS POOL[LCEMEN IN 2,500 psi NG�(IF SPECIFIED) `WATERLINE TILES POOL FINISH _--1-#3 REBAR @ 12" O.C.E.W. RAISED SPA DETAIL CONTRACTOR MUST PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN 6" ON CENTER IN BOTH DIRECTIONS IN THIS CRITICAL AREA. ALSO THE POOL SHELL WALL SHALL BE CONSTRUCTED TO 6" THICKNE THE STEEL MAT AND THICKER SHELL WALL SHALL EXTEND ALONG THE CRITICAL AREA AND TO A POINT WHICH IS GREATER THAN THE MINIMUM REQUIRED AS DETERMINED BY THE 1 ON 1 + 1 METHOD. PLAN EXPIRES 1 YEAR FROM THE SIGNATURE DATE OR THE EFFECTIVE DATE OF A MAJOR FLORIDA BUILDING CODE CHANGE WHICHEVER IS SOONER AUG 17 2017 Date Y• `�fr ` Skilo Engineering Services, Inc. Larry S. Schnaper, P.E. FL PE NO..32046 2431 Aloma Ave., Ste. 124 Winter Park, FL 32792 (407) 275-1099 ;ERS ARE TO BE ,,.SS BRACED PER ESCUTCHEON MANUFACTURERS SPECS PLATE S.S. LADDER POOL 1 -]/,,--DECK LEVEL `EXPANSION SLIP RESISTANT JOINTS AS WEDGE REQUIRED TREAD SURFACE ANCHOR ADDITIONAL CONCRETE AS REQUIRED FOR 3" MIN. TO 6" MAX ' ` STURDY INSTALLATION BETWEEN TREAD AND POOL WALL RUBBER_ #8 BARE, SOLID, COPPER CONDUCTOR TO SHELL BUMPER REINFORCING TYPICAL LADDER DETAIL f#8 AWG COPPER WIRE TIME TO SERVICE CLOCK SPST TOGGLES I ' P. SWITCH `� DISC. 4'-0� JUNCTION 12V POOL BOX TRANS. DECK ALL ELECTRICAL WORK SHALL CONFORM WITH ART. 680 OF THE 3 #12 IN Yz" LATEST ADAPTED NEC. CONDUIT i__-12V/40OW MAX. POOL LIGHT W/ LOW WATER CUT-OFF OR 120 V.A.C. W/ GFI PER NEC. ELECTRICAL DIAGRAM 1.11 AMERICAN POOLS & SPAS 7320 Narcolasee Rd Orlando FL 32822 PA �407) 847-9322 CPCO57251 Swimming Pool Specification For: 5212 PINE TREE DR FORT PIERCE FL Scale: None Rev 10 — 06/30/15 T n �_ 1—#3 BAR CONTINUOUS { J 1—#3 BAR CONTINUOUS BRICK"CONCRETE 1—#5 BAR VERTICALLY COMPACTED PAVRER POOL DECK1—#5 BAR VERTICALLY POOL DECKR TURNDOWN NOTES COMPACTED POOL DECK SUBGRADE 1. Detail is based on NO surcharge behind the Turndown and the Ground away from AT 36 BASE MATERIAL ON CENTER AT 36 ON CENTER the Turndown is Level (>4 to 1). Turndown may abut Ribbon Footer and be tied A = 6" to 24" into Footer if Appropriate, with #3 Rebar. ' ` •N j ` PAVER ' SECURED TO TOP �, PROPOSED FINISHED °'• ' ¢ B = - x A (4.5" to 18'� OF TURNDOWN BY PAVER 2. Turndown shall bear on Rock, Clean Sand or StructurallySound Soils >1,500 PSF GRADE (COMPACTED) ( ) : PROPOSED FINISHED INDUSTRY STANDARDS that shall be compacted to provide Optimum Bearing Capacity and prevent Settling 1—#5 BAR CONTINUOUS 4 MIN. COMPACTED SUBGRADE 'p•:: GRADE (COMPACTED) or Shifting. --,1 1—#5 BAR CONTINOUS m 4 MIN. SEE PAVER DECK 3. Al ReinforcingSteel is to Conform to ASTM 615, Grade 40. TURNDOWN DETAIL 8" —� 1 4"0 CONCRETE PILASTER FOR INFORMATION 0 8^ NOT SHOWN 4. Concrete shall contain Fiber Mesh and have a 28 Day Compressive Strength of AT 5 —0 ON CENTER WITH I EXISTING 2,500 PSI. 1—#3 BAR VERTICALLY I N rGRADE 4"0 CONCRETE PILASTER # _ __ NIA AT 5'-0" ON CENTER WITH EXISTING 9 T—I IT=III e • I I� I' III— 1—#3 BAR VERTICALLY NI GRADE 5. All Construction to Conform to Florida Building Code, 5th Edition, 2014, FBC - Tj�r Building and FBC Residential. —III=1 I LT i t T— z l l=1 I I '—I 1=� I I— 4" II,�,I�I—ICI e . I� �c � -LIL 6. Refer to Contractor's Plan on file with the Building Department for Details on Turndown Location. " 7. If the Base of the Turndown does not extend into the Old (Existing) Ground, a 4"0 CONCRETE DECK TURNDOWN ALTERNATE PAVER ON TURNDOWN Pilaster will be required every 5'-0" that will be either 2'-0" into the Ground or PA VER DECK TURNDOWN to 6" into the Indigenous Material, Whichever is Deeper. The Pilaster will have a CONCRETE CONCRETE DRAINAGE SWALE� 1—#3 BAR CONTINUOUS #3 Rebar tied into the #5 Rebar in the base of the Vertical Pour. PROPOSED POOL DECK PROPOSED POOL DECK FINISHED FINISHED 1—#5 BAR VERTICALLY 8. A Deck Turndown is NOT intended to be a substatute for a Retaining Wall. If the GRADE GRADE " mio ,D' AT 36" ON CENTER Vertical Dimension from the Top of the Concrete Deck to the Old (Existing) Ground �. d reaches 36" for a 6" Turndown, 42" for a 12" Turndown, 48" for a 18" turndown, ' 1=1 I I=1 11= "'—� I=1 I 1=- —I I 1=1 11= Q 1—#5 BAR CONTINUOUS 54" for a 24" Turndown, for more than 20% of the Turndown Length or the Finished Grade Slope exceeds (steeper than) 4' Horizontally and 1' Vertically, a I g" I 1—#5 BAR A = 6" to 24" BRICK PAVER " °i .' POOL DECK Turndown should not be used.CONTINUOUS B = x A (4.5 to 181 p NO FOOTER 8" x 8" FOOTER 9.• For a Paver Deck, if the Vertical Dimension from the To of the Deck to the Old ••'' (Existing) Ground reaches 24" for a 6" Turndown, 30" for a 12" Turndown, 36" for a 18" Turndown, 42" for a 24" Turndown, for more than 20% of the Turndown m e' Length or the Finished Grade Slope exceeds (steeper than) 4' Horizontally and 1' CONCRETE CONCRETE COMPACTED PAVER Vertically, a Turndown shall not be used. PROPOSED POOL DECK PROPOSED POOL DECK ° ' • BASE MATERIAL FINISHED FINISHED 8„ COMPACTED SUBGRADE 10, If a Screen Enclosure is to be installed, the Swimming Pool Contractor must GRADE • ,., : • •.: • °; e: ••° GRADE 0"i coordinate Design and Construction of the Turndown Requirements with the Screen Contractor to Ensure it meets their Requirements. —I I °... I=1 11= ALTERNATE PAVER LOCATION 12" 2—#5 BARS p. 2—#5 BARS CONTINUOUS 12" CONTINUOUS FOOTER NOTES 1. If a Screen Enclosure is to be installed, the Swimming Pool Contractor must Coordinate Design and Construction of any required Footer with the Screen Contractor. 2. Footer shall bear on Rock, Sand or Structurally Sound Soils (>1,500 PSF) that shall be compacted to provide Optimum Bearing Capacity and prevent Settling or Shifting. 3. Concrete shall have a 28 Day Compressive Strength of 2,500 PSI with Fiber Mesh or 6x6-10x10 W.W. Mesh. 4. (3) #3 Rebars is Equivalent to (1) #5 Rebar. 5. A Footer may be installed with a Brick Paver Pool Deck if required by the Jurisdiction or at the Option of the Contractor and may be placed over the Top of the Footer or Abutting the Side of the Footer. BRICK PAVER PROPOSED POOL DECK FINISHED GRADE 1=1 11=1 11= "'LI —F11=11- 1 11= CONCRETE PAVERS ON CONCRETE DECK CONCRETE DECK MAY BE CONSTRUCTED WITH A FOOTER OR WITHOUT A FOOTER 8" x 12" FOOTE BRICK PAVER PROPOSED POOL DECK FINISHED GRADE • 2—#5 BARS 12" CONTINUOUS 12" x 12" FOOTER W/ PA VER DECK R 12" x '—"'FOOTER BRICK PAVER PROPOSED POOL DECK FINISHED GRADE r, kl I�8" 1—#5 BAR F'—'1 CONTINUOUS OPTIONAL EDGE RESTRAINT PROPOSED FINISHED BRICK PAVER PROPOSED GRADE - POOL DECK FINISHED GRADE COMPACTED COMPACTED SUBGRADE PAVER BASE PAVER DECK WITHOUT FOOTER OPTIONAL: CONCRETE OR PLASTIC EDGE RESTRAINT MAY BE )ED TO THE DECK PERIMETER AS NEEDED TO SECURE PAVERS - 8" x 8" FOOTER Wf PA VER DECK BRICK PAVER POOL DECK 12" 245 BARS CONTINUOUS At x 12"_ FOOTER V/ PA VER DECK AUG 17 2017 Skilo Engineering Services, Inc. Larry, 9.) Schnaper, P.E. FL, PE # 32046 2431 Aloma Ave. Ste 124 Winter Park, FL 32792 Office: (407) 275-1099 '1� A ERICAN POOLS & SPAS 7320 .Narcoosee Rd Orlando FL 32822 (407) 547-9322 CPCO57251 Swimming Pool Specification For: 5212 PINE TREE DR FORT PIERCE FL Scale: None Rev 11 — 06/16/17 T