Loading...
HomeMy WebLinkAboutEvaluation Reports RECEIVED OCT o a 7017. ST,LUCIE COUNTY EXTERIOR RESEARCH & DESIGN, LLC. BUILDING DIVISION Certificate of Authorization#9503 � F�N�.TY ERD •�'•,. 353 CHRISTIAN STREET, UNIT #13 l FOR O® �0E OXFORD, CT 06478 REVIEWED BY � PHONE: (203) 262-9245 DATE 1i —) 1) FAX: (203) 262-9243 EVALUATION REPORT 'PLANS AND PERMIT GAF MUST BE KI2PT ON JOB OR Evaluation Report 01506.01.08-1121 NO INSPEOTION WILL D5 MADE FL10124-R19 1 Campus Drive _ , ,, �...,w ,. 4 - Parsippany, NJ 07054 _ r Date of Issuance: 01/03/2008 Revision 21: 08/26/2016 SCOPE: This Evaluation Report is issued under Rule 61620-3 and'the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the, Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5ch Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluatio�eport consists of pages 1 through 6. I hl aNt S AND ALL PROPOSED WORK Prepared ME 1 gAu fir► ^a�{ Rua,S c,ro na THAT �A;a CO��P,LY FP�IGRobert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 Py The facsimile seal appearing was authorized by Robert N leminen, P.E. on 08/26/2016. This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. CONCEALED FASTENERS OR MACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD i TRINITY 1 ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, R905.2.3 Physical Properties ASTM D1970 2009 1507.2.5, R905.2.4 Physical Properties ASTM D3462 . 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2008 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entit Examination Reference Date GAF (PDM 1915) Letter of Equivalency Seal -A -Ridge Impact Resistant IR 01/13/2012 PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL (TST 1740) ASTM D3462 93NK6295 11/29/1993 UL (TST 1740) ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL (TST 1740) ASTM D3462 01NK06632 02/02/2001 UL (TST 1740) ASTM D3161, TAS 107 01NK9226 05/21/2001 UL (TST 1740) ASTM D3161 01NK37122 12/18/2001 UL (TST 1740) ASTM D3462 01NK37122 12/19/2001 UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002 UL (TST 1740) ASTM D3161 03CA5367 03/11/2003 UL (TST 1740). ASTM D3462 03NK26444 10/17/2003 UL (TST 1740) ASTM D3462 04NK13850 06/07/2004 UL (TST 1740) ASTM D3161 04N1(13850 06/23/2004 UL (TST 1740) ASTM D3161 04NK30546 03/10/2005 UL (TST 1740) ASTM D3462 04NK22009 05/06/2005 UL (TST 1740) ASTM D3161 04NK22009 05/09/2005 UL (TST 1740) ASTM D3462 05NK27924 02/10/2006 UL (TST 1740) ASTM D3161 05NK27924 02/11/2006 UL (TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL (TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL (TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL (TST 1740) ASTM D3462 06CA31603 12/01/2006 UL (TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL (TST 1740) ASTM D3161 07NK05228 03/13/2007 UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL (TST 1740) ASTM D3161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008 UL (TST 1740) ASTM D3161,D3462 07CASS908 04/01/2008 Exterior Research and Design, I.I.C. Evaluation Report 01506.01.08-R21 Certificate of Authorization #9503 F1.10124-1119 Revision 21: 08/26/2016 Page 2 of 6 �~ �TRINITYIRD Entity Examination Reference Date UL (TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL (TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010 UL (TST 1740) ASTM D3161, D7158, D3462 IOCA13686 05/15/2010 UL (TST 1740) ASTM D3462 10CA07264 05/27/2010 UL (TST 1740) ASTM D3462 10CA11953 10/29/2010 UL (TST 1740) ASTM D3161,D7158,D3462 IONK11951 10/30/2010 UL (TST 1740) ASTM D3161,D7158,D3462 IONK12070 11/04/2010 UL (TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL (TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL (TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011 UL (TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011 UL, LLC. (TST 9628) ASTM D3462 12CA34891 10/12/2012 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 12CA58151 02/15/2013 UL, LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013 UL, LLC. (TST 9628) ASTM D3161 13CA32332 06/18/2013 UL, LLC. (TST 9628) ASTM D3161 13CA37934 08/02/2013 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786875675 07/27/2015 UL, LLC. (TST 9628) ASTM D3161,D7158,D3462 4787434542 OS/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mobile, AL 12/28/2015 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Myerstown, PA 02/23/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tuscaloosa, AL 02/26/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Michigan Cty, IN 03/02/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Shafter, CA 02/18/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Savannah, GA 02/24/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Minneapolis, MN 02/09/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mt. Vernon, IN 02/09/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Baltimore, MD 03/01/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tampa, FL 02/29/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Dallas, TX 02/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Ennis, TX 02/03/2016 UL, I.I.C. (QUA 9625) Quality Control Inspection Report, R21, Fontana, CA 03/03/2016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelot® II, FortitudeT", Glenwood'"", Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShieldT1, Monaco°, Sienna®, Timberline® American Harvest®, Timberline® ArmorShieldT" II, Timberline® Natural Shadow®, Timberline HD®, Timberline® Cool Series®, Timberline Ultra HD® and Woodland® are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 Slateline® is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip & Ridge Shingles: 4.2.1 Seal -A -Ridge® Ridge Cap Shingles, Seal -A -Ridge° IR Impact -Resistant Ridge Cap Shingles, Seal -A -Ridge® ArmorShieldT°" Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Exterior Research and Design, I.I.C. Evaluation Report 01506.01.08-1121 Certificate of Authorization #9503 FL10124-R19 Revision 21: 08/26/2016 Page 3 of 6 JTRINITY!ERD I 4.3 Accessory Starter Strips: 4.3.1 Pro -Start® Eave/Rake Starter Strip Shingles and WeatherBlocker"" Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 StarterMatch'" Sharter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatchTm are installed as the second starter for Grand Canyon19 and Grand Sequoia'9series installations. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings•ofthis product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to V,,d =150 mph (V,,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vmd = 150 mph (V„ it =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.' 6.2 Starter Shingles or Starter Strip: 6.2.1 Installation of Pro -Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five (5) nails per shingle. ➢ Slateline requires minimum six (6) nails per shingle. Exterior Research and Design, I.I.C. Evaluation Report 01606.01.08-R21 Certificate of Authorization #9503 F1.10124-1119 Revision 21: 09/26/2016 Page 4 of 6 J TRINITY I ERD 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Seal -A -Ridge Ridge Cap Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and Seal - A -Ridge ArmorShield Ridge Cap Shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel "Loctite PL S30 Roof & Flashing Sealant". 11.5" Sealant 1. (292 mm) 1" / Sellante (25 mm) (221—TT.), Enduit d'etanch6it6 12" (305 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. 1• 1 % a" (2M Seatatrl (25 rnm) Sollonlo (25 rnm} z:riduit d'ttanchkb d�a�l i:�uar (305 turn) 9' (2n MM) it (&35 rrul.) 6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design, I.I.C. Evaluation Report 01506.01.08-R21 Certificate of Authorization #9503 FL10124-R19 Revision 21: D8/26/2016 Page 5 of 6 7. 8. 9. 10. (T-�RINITYIERD LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. QUALITY ASSURANCE ENTITY: UL LLC — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report 01506.01.08-1121 Certificate of Authorization #9503 F1.10124-1119 Revision 21: 08/26/2016 Page 6 of 6 RECEP!7D OCT 0 3 7017 QOTRINITYIERD EVALUATION REPORT GAF 1 Campus Drive Parsippany, NJ 07054 (800)766-3411 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report 01506.02.06-1112 FL6267-R12 Date of Issuance: 02/28/2006 Revision 12: 02/14/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections referenced herein. DESCRIPTION: GAF Roof Ventilation Products LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4ANE1983 c (% The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 02/14/2017. This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest In any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. \l TRINITY I ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance. Statement: GAF Roof Ventilation Products, as produced by GAF, have demonstrated compliance with the following sections of the Sth Edition (2014) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3 Wind ASTM E330 2002 1506.5 / 1517.5.1 Corrosion Resistance (of nails) TAS 114, Appendix E 1995 1523.6.5.2.13 Wind Driven Rain TAS 100(A) 1995 1523.6.5.2.13.1 Physical Properties TAS 110 2000 2614.2 Weatherometer ASTM G155 2005 3. REFERENCES: Entity Examination Reference Date ATI (TST 1558) Physical Properties 01-49035.01 03/02/2004 ATI (TST 1558) Wind Driven Rain 01-44964.01 01/15/2004 ATI (TST 1558) Wind Driven Rain 60172.01-122-18 10/07/2005 ATI (TST 1558) Physical Properties 59665.02-106-31 09/16/2005 ATI (TST 1558) Wind Driven Rain 84608.01-106-18 11/12/2008 ATI (TST 1558) Wind Driven Rain A5250.01-109-18 02/18/2011 ATI (TST 1558) Wind Uplift 87074.01-109-44 12/03/2008 ATI (TST 1558) Wind Uplift C2396.01-109-44 11/05/2012 ATI (TST 1558) Wind Uplift D1957.01-109-44 03/04/2014 ATI (TST 1558) Wind Uplift E0818.01-109-44 09/23/2014 ATI (TST 1558) Physical Properties D2702.01-106-18 06/30/2014 ATI (TST 1558) Wind Uplift E6744.01-109-44 04/30/2015 ATI (TST 1558) Wind Driven Rain G2331.01-309-44 01/10/2017 PRI (TST 5878) Weatherometer HBP-007-02-01 06/24/2004 PRI (TST 5878) Physical Properties HBP-002-02-01 06/06/2001 PRI (TST 5878) Wind Driven Rain HBP-01-02-01 11/02/2000 PRI (TST 5878) Wind Driven Rain BRY-021-02-01 12/31/2003 PRI (TST 5878) Physical Properties BRY-025-02-01 09/17/2004 PRI (TST 5878) Physical Properties GAF-138-02-06 02/09/2007 PRI (TST 5878) Wind Driven Rain GAF-138-02-04 02/09/2007 PRI (TST 5878) Wind Driven Rain GAF-310-02-01 07/07/2011 ETC Labs (TST 2411) Physical Properties ETC-01-718-10379.0 01/16/2000 ETC Labs (TST 2411) Physical Properties ETC-03-718-14602.0 01/20/2004 ETC Labs (TST 2411) Physical Properties ETC-07-718-19959.0 09/27/2007 Miami -Dade (CER 1592) Various Various NOAs Current Miami -Dade (CER 1592) Corrosion Resistance (of nails) Certification L 12-0614.08 06/26/2012 Miami -Dade (CER 1592) Corrosion Resistance (of nails) Certification L 12-0601.24 06/29/2012 Miami -Dade (CER 1592) Corrosion Resistance (of nails) Certification L 15-0421.09 05/07/2015 UL, LLC. (QUA 9625) Quality Control Inspection Report, R15072, GA1 03/23/2016 UL, I.I.C. (QUA 9625) Quality Control Inspection Report, R15072, GA2 04/15/2016 Exterior Research and Design, I.I.C. Evaluation Report 01506.02.06-1112 Certlflcate ojAuthorhation #9503 FBC NON-HVHZ EVALUATION 171.6267-1112 GAF Revision 12: 02/14/2017 Page 2 of 10 ��TRINITYJERD 4. PRODUCT DESCRIPTION: 4.1 Cobra® Exhaust Vent is a low -profile attic ridge vent of mesh -construction for use in shingle roof systems. The product measures 10Y2-inch wide supplied in 20 and 50 ft long rolls, and is supplied with corrosion resistant 1%-inch coil nails (nail gun version) or 2'/:-inch Smart NailS'"" (hand nail version). Cobra® Exhaust Vent has a published net free ventilation area (NFVA) of 14.1 inZ / lineal foot for nail gun version and 16.9 inZ / lineal foot for hand nail version. 4.2 Cobra® Rigid Vent 3'"' is a plastic, low -profile attic ridge vent for use in shingle roof systems with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and is supplied with 3-inch corrosion resistant ring shank nails. Cobra® Rigid Vent 311" has a published net free ventilation area (NFVA) of 18 in"/ lineal foot. 4.3 Cobra® Rigid Vent 31 - 9" is a plastic, low -profile attic ridge vent for use in shingle roof systems with 10- inch width ridge caps. The product measures 11Y2-inch wide supplied in 48-inch long sections, and is supplied with 3-inch corrosion resistant ring shank nails. Cobra® Rigid Vent 37"' - 9" has a published net free ventilation area (NFVA) of 18 inZ / lineal foot. 4.4 Cobra® Snow Country"' is a plastic, low -profile attic ridge vent with filter for use in shingle roof systems. The product measures 13-13/16-inch wide supplied in 48-inch long sections. Cobra® Snow Country'"' has a published net free ventilation area (NFVA) of 18 inZ / lineal foot. 4.5 Cobra" Snow Country Advanced'" is a plastic, low -profile attic ridge vent with filter for use in shingle roof systems with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and is supplied with 3-inch corrosion resistant ring shank nails. Cobra® Snow Country Advanced"' has a published net free ventilation area (NFVA) of 18 inZ / lineal foot. 4.6 Cobra® Snow Country Advanced"" - 9" is a plastic, low -profile attic ridge vent with filter for use in shingle roof systems with 10-inch width ridge caps. The product measures 11'/:-inch wide supplied in 48-inch long sections, and is supplied with 3-inch corrosion resistant ring shank nails. Cobra® Snow Country Advanced'"' - 9" has a published net free ventilation area (NFVA) of 18 inZ / lineal foot. 4.7 Cobra® Ridge Runner® is a polypropylene plastic, low -profile attic ridge vent for use in shingle roof systems. The product measures 11Y2-inch wide supplied in 20 ft long rolls, and is supplied with corrosion resistant 1%-inch coil nails. Cobra® Ridge Runner® has a published net free ventilation area (NFVA) of 12.5 inZ / lineal foot. 4.8 TruSlatem Ridge Vent is a plastic, low -profile attic ridge vent for use in TruSlate® roof systems. The product measures 11.4-inch wide supplied in 48-inch long sections. TruSlate® Ridge Vent has a published net free ventilation area (NFVA) of 20 inZ / lineal foot. 4.9 Cobra® Hip Vent is a plastic, low -profile attic hip vent with filter for use in shingle roof systems. The product, only for use on hips, measures nominal 11.4-inch wide supplied in 48-inch long sections, and is supplied with corrosion resistant 1%-inch coil nails. Cobra® Hip Vent has a published net free ventilation area (NFVA) of 9 in'/ lineal foot. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. Exterior Research and Design, U.C. Evaluation Report 01506.02.06-1112 Certiftate ojAuthari:ation H9503 FBC NON-HVHZ EVALUATION FL6267-R12 GAF Revision 12: 02/14/2017 Page 3 of 10 5.3 `�, TRINI7Y I ERD Minimum Roof Slopes: Product j Minimum Slope Cobra® Exhaust Vent 2:12 Cobra" Rigid Vent P1 3:12 Cobra® Rigid Vent 3'11 - 9" 3:12 Cobra® Snow CountryT"^ 3:12 Cobra" Snow Country Advanced TM 3:12 Cobra" Snow Country Advanced'"" - 9" 3:12 Cobra® Ridge Runner® 3:12- ' TruSlate® Ridge Vent 5:12 Cobra® Hip Vent Min. 3:12 to max. 12:12 5.4 Unless otherwise determined through use of performance levels in Section 5.5, the maximum mean roof height for Cobra® Exhaust Vent, Cobra® Rigid Vent 3, Cobra° Rigid Vent 3 — 9", Cobra® Snow CountryT"", Cobra® Snow Country Advanced'"", Cobra® Snow Country Advanced'"" — 9", Cobra® Ridge Runner®, TruSlate® Ridge Vent and Cobra® Hip Vent shall be 33 ft. 5.5 Maximum Allowable Design Pressures: The following performance levels may be utilized for projects where the maximum mean roof height exceeds 33 ft. The Allowable Design Pressure shall meet or exceed critical design pressure determined by a qualified design professional in accordance with FBC Chapter 16. No rational analysis is permitted. Allowable Design: Substrates Product Pressure (psf) Min. 7/16-inch plywood Cobra" Exhaust Vent (nail gun version) -150 Min. 7/16-inch plywood Cobra® Exhaust Vent (hand nail version) -180 Min. 7/16-inch plywood Cobra" Rigid Vent 3111, Rigid Vent 3` - 9", Snow -215 CountryTM, Snow Country Advanced'" and Snow Country AdvancedTM - 9" Min. 7/16-inch--OSB.—or_--Co.b.ra®g Rid a Runner®l I ,,,plywood - Min. 7/16-inch plywood TruSlate® Ridge Vent -190 Min. 7/16-inch plywood Cobra" Hip Vent -205 5.5.1 Allowable Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.6 Installation shall result in minimum net free ventilation area requirements set forth in FBC Sections 1203.2. When more than one level of roof ridge existing over a single attic space, use ridge vents only at the high ridge. Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R32 Certificate afAuthoriration #9503 FBC NON-HVHZ EVALUATION FL6267-1112 GAF Revision 12: 02/14/2017 Page 4 of 10 QCTRINITYIERD 6. ,INSTALLATION: 6.1 GAF Roof Ventilation Products shall be installed in accordance with GAF published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 COBRA® EXHAUST VENT: I 6.2.1 Chalk a cut -line 1-inch off each side of the ridge and cut a slot along the apex of the roof measuring 2-inch (for truss construction) or 3Y2-inch (for ridge pole construction). The slot should terminate 6-inches from each end and 12-inches from hip intersections or chimneys. Cut only the sheathing; do not cut trusses. Figure A. 6.2.2 Unroll the vent along the entire length of the ridge, covering uncut 6-inch sheathing area on both ends. Shorter lengths can be joined by caulking and butting the ends. Figure B. 6.2.3 Apply a bead of polyurethane roof sealant to the underside of the entire perimeter of the vent and nail with min. 2Y.-inch galvanized roofing nails, at each corner and 10-inch o.c. Do not use excessive roof cement, as it may result in shingle blistering. 6.2.4 Apply a bead of polyurethane roof sealant in the shape of a "C" to the underside of the entire perimeter of the cap shingles, and install cap shingles directly over the vent using Smart Nails'"' or 1%-inch corrosion resistant coil nails (supplied with the vent). Figure C. Do not use excessive roof cement, as it may result in shingle blistering. 6.2.5 Cobra® Exhaust Vent (hand nail version) and Cobra® Exhaust Vent (nail gun version) have a %-inch or 5/8-inch nominal thickness, respectively, to facilitate ventilation. Care shall be taken not to crush or compact the product during installation. Figure D. Hand -Nail Version Nail Gun Version Exterior Research and Design, LLC. Evaluation Report 01506.02.06-1112 Certyicate oJAuthorkation #9503 FBC NON-HVHZ EVALUATION FL6267-R12 GAF Revision 12: 02/14/2017 Page 5 of 10 �\J\TRININ ERD 6.3 COBRA® RIGID VENT 37m,, RIGID VENT 3TM = 9", SNOW COUNTRY*"', SNOW COUNTRY ADVANCEDT"'.AND SNOW COUNTRY ADVANCEDTM'- 9": 6.3.1 Mark-ott and cut the slot opening as follows, ensuring that the ends of the opening stop at least 6-inch from any end walls and at least 12-inch from hip and ridge intersections or chimneys. ➢ No Ridge Board: Cut a 7/8-inch opening on each side of the ridge (Figure A). ➢ With Ridge Board: Cut a 1-5/8-inch opening on each side of the ridge (Figure B). 15/e ilk' _11><. i I I _"� 31/4" With Ridge Board 6.3.2 Sealant: Apply a bead of silicone caulking or roof cement to the underside of the outer baffle along both edges and at exposed ends, ensuring the outside edges where the vent meets the shingles are sealed with the caulk or flashing cement. 6.3.3 Vent Placement: Starting at one end of the slot, place, center and conform the Cobra® rigid vent over the slot with the vent firmly against the roof surface, ensuring the vent extends past the slot opening by at least 6-inch. 6.3.4 Fasteners: For Cobra® Rigid Vent 3T1, Cobra® Rigid Vent 3TM - 9", Cobra" Snow Country AdvancedTm and Cobra® Snow Country AdvancedTm - 9" only, use the 3-inch corrosion resistant ring shank nails (included). For Cobras Snow Country1m, use corrosion resistant nails at least 3-inch or longer. Nails must always penetrate through plywood decks or at least %-inch into wood planks. NOTE: GAF recommends 3-inch corrosion resistant ring shank nails for increased uplift resistance. 6.3.5 Spacing: Attach the vent section through the pre -molded nailing holes located at 3, 12, 24, 36 and 45-inch from the start of each 48-inch vent piece. 6.3.6 Joints: Apply the subsequent Cobra® rigid vent sections over the length of the ridge using the overlap/underlap tabs. 6.3.7 Ridge Shingles: Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using corrosion resistant nails detailed in 6.3.4. A nail line is inscribed on top of the Cobra® rigid vent to serve as a guide. Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R32 Certijkate oJAuthorization #9503 FBC NON-HVHZ EVALUATION F1.6267-1112 GAF Revision 12: 02/14/2017 Page 6 of 10 `JrTRINITY I ERD 6A COBRA®'RIDGE'RUNNER® ' 6.4.1 Cut slot per 6.3.1. 6.4.2 Tear a 1-foot section to be used as a template for laying the vent out (Figure E-G) and center the template/ locator over the ridge cap shingles at the beginning of the vent slot. Note the location of the baffle (Figure H). Make sure to do this at both ends of the installation. �_!f7 1 6.4.3 Measure the distance from the edge of the roof slot to the exterior baffle (D). Establish a chalk line along one side of the ridge (Figure 1). Unroll the vent and use the included 1-3/4-inch pneumatic corrosion resistant roofing nails to attach the first side of the ridge vent with the exterior of the baffle aligned with the chalk line (Figure 1). Proceed with using the 1' interval EasyTearlm system to custom size the vent to the appropriate length. If the EasyTear- system can not be utilized, use a utility knife to size the vent. Nail gun targets are embossed on the part as a guide for property attaching vent to the roof. The vent should be fastened on 6-inch centers (Figure K). Exterior Research and Design, I.I.C. Evaluation Report 01506.02.06-R12 Certi tcate olAuthoriiation #9503 FBC NON-HVHZ EVALUATION FL6267-R12 GAF Revision 12: 02/14/2017 Page 7 of 10 �I TRINITY I ERD 6.4.4 NOTE: When fastening the vent and cap shingles, be sure that the included 13/4-inch corrosion resistant coil nails completely penetrate plywood or provide at least 3/4-inch penetration into wood planks. In the case they do not, you must use alternate corrosion resistant nails that provide the required penetration. Proceed with attaching the other side of the vent. When beginning to nail down the second side, do NOT begin at the end; begin between the first and second one -foot sections and then return to fasten the first one -foot section. This will allow for proper fit. 6.4.5 Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using the nail -lines on top of the ridge vent for proper lapping. 6.5 TRUSLATE® RIDGE VENT: 6.5.1 DO NOT use on hips. 6.5.2 Intall TruSlate® Ridge Vent before installing the field slates. 6.5.3 After determining the total length of TruSlate® Ridge Vent required (for proper ventilation), determine the necessary slot opening. Mark -off and cut the slot opening, ensuring the ends of the opening stop at least 6-inch from any end walls and at least 12-inch from hip and ridge intersections or chimneys. Roofs without a ridge board: Cut a 7/8-inch opening along the ridge on each side (Figure A). Roofs with a ridge board: Cut a 1-5/8-inch opening along the ridge on each side (Figure B). Fig. A Fig. B (41 mm)1%' (41 mm) (22 mm)1/g" %" (22 mm) 394 (s2 mm) Wfth Ridge Board 1114" (44 mm) No Ridge Board 6.5.4 Install an 18-inch wide section of ASTM D1970 self -adhering leak barrier (holding Florida Statewide Product Approval or Approved on a Local Basis) from the edge of the ridge slot extending down towards the roof deck on both side of the slot. 6.5.5 Place the TruSlate® Ridge Vent over the ridge slot, "peaked" and centered over the ridge slot, and attach using minimum 3-inch long corrosion resistant ring -shank nails through the pre -molded nail holes on the vent, located 3-inch from the ends and 9-inch o.c. Fasteners shall penetrate through plywood decks or embed minimum %-inch into wood plank decks. 6.5.6 Continue over the length of the ridge, utilizing the male/female connectors to connect units. Ensure the finished ends include the pre -molded end caps. Cover all exposed nail heads on the vent with silicone caulk. Intall a bead of exterior grade silicone sealant at the downslope leading edges of the ridge vent, at the junction of the leading edge and the leak -barrier below. 6.5.7 Install the top course of TruSlate® field slates, UnderBlock'" UV & Moisture Barrier and TruSlate® trim slates in accordance with GAF published installation instructions. Intall TruSlate® trim slates with 10-inch exposure using minimum 1-5/8-inch long deck screws through pre -drilled holes, through the ridge vent to engage the wood deck. Exterior Research and Design, I.I.C. Evaluation Report 01506.02.06-1112 Certijlcate of Authorization #9503 FBC NON-HVHZ EVALUATION FL6267-R12 GAF Revision 12: 02/14/2017 Page 8 of 10 Roof Dedc Pralocthn i Wealhor Watcho or StarmGuard@) Leak Bartior 10.. 257 mm �l I KINITY I ERD 6.61. COBRA® HIP VENT 6.6.1 The roof deck shall consist of minimum of 7/16 inch thick plywood or OSB wood structural panels. Use only on roofs with slopes between 3:12 and 12:12. Install only on hips. Do not install Cobra" Hip Vent on ridges. 6.6.2 Sequencing: If ridge ventilation will be installed, always install the ridge vent to the end of the ridge before installing Cobra" Hip Vent. 6.6.3 Hip Air Slot: Determine the number of Cobra' Hip Vent sections needed for proper ventilation and the location for cuts in the roof hip. Cobra' Hip Vent is installed over a 2% inch wide slot opening centered on the hip beginning at 12 inches below the top of the hip and extending 36 inches down the hip for every 4 foot section of Cobra' Hip Vent needed. Leave 12 inches of the hip uncut after each 36 inch opening, and the lowest opening must stop at the mid -point of the hip and more than 24 inches in from the exterior warm wall. Wider openings and slots below the midpoint of the hip will not improve ventilation and must be avoided. Cut away the shingles first with a roofing knife, and then cut the deck with a circular saw. The saw should be adjusted so that the rafters or trusses are not cut. Note: The roof decking must be re -nailed to the rafter at the edge closest to the hip to compensate for the nails removed when the hip slot was cut. Ridge Air Slots Hip Midpoint I I I I I F�00 I Slot length nearest midpoint may vary I pc� \off I v pae I 0 Deck I I Eave I �I I Must be at least 24" (610 mm) from the warm wall Exterior Research and Design, LLC. Evaluation Report 01506.02.06-1132 Certificate ofAuthoriration #9503 FBC NON-HVHZ EVALUATION FL6267-R12 GAF Revision 12: 02/14/2017 Page 9 of 10 TRINITY i ERD 6.6.4 Sealant: Seal all cut -edges of the asphalt shingles to the roof sheathing along all sides of the hip air slot openings, using a bead of ASTM C920 polyurethane sealant, to prevent water infiltration. 6.6.5 Orientation: Always install Cobra® Hip Vent with the "Towards Peak" arrows on the top surface of the vent pointing up towards the peak of the roof. 6.6.6 Attachment: Cobra® Hip Vent is fastened to the deck starting at the bottom of the hip and then up along the entire length of the hip (this includes un-cut portions of the hip). Fasten Cobra' Hip Vent to the deck with the included 1%-inch inch long collated galvanized steel roofing nails, or longer corrosion resistant roofing fasteners, to achieve penetration through plywood or OSB decks or minimum 3/4-inch embedment into wood planks. Attach the Cobra® Hip Vent section through the pre -marked 6-inch increment nail targets. 6.6.7 Joints & Terminations: Apply the subsequent Cobra® Hip Vent sections over the length of the hip using the overlap/underlap tabs. For roofs with ridge vents, lengths of the hip vent must be butted tightly to sections of ridge vents and install a 3 inch by 12-inch strip of self -adhering leak barrier over all junctions. For roofs without ridge vents, sections of hip vent from adjacent hip runs must be mitered together tightly where they intersect and install a 3 inch by,12-inch strip of self -adhering leak barrier over all junctions. Refer to GAF published installation instruction for details. 6.6.8 Ridge Shingles: Cobrao Hip Vent is then covered with ridge cap shingles and this entire assembly is nailed to the sheathing with the included 1%-inch inch long collated galvanized steel roofing nails. Depending on the field and ridge cap shingles used, longer length corrosion resistant fasteners may be necessary. The ridge cap shingles are installed per the shingle manufacturer's instructions and Florida Product Approval, with a minimum of two nails per shingle and a shingle to shingle nail spacing of 8 inches on center or less. Refer to the shingle manufacturer's Florida Product Approval for ridge cap shingle fastening and sealing requirements. Do not overdrive the nails or crush/compact the product during installation. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA requirements. 9. QUALITY AssuRANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 01506.02.06-1112 Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL6267-R12 GAF Revision 12: 02/14/2017 Page 10 of 10