Loading...
HomeMy WebLinkAboutProduct Approvalr41412017 R � C � I V E D OCT .0 3 201Florida Building Code Online 6ins,us.r 1 a + aCIS Home Log In User Registration Ilol Tapka Submll Surcharge SWIs 6 Fac15 Publications r11C Staff ISC1S SRe hfap Links Searrn 1 Product Approval USER: Public User d ',b r 'rn t t : rmval Ftnnu > Product nr hnPlknikm Senirh > 811RII ,i ion iLl > Application Detail FL. # F1-5680-1117 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) GAF 1 Campus Drive Parisppany, NJ 07054 (800) 766-3411 mstieh@gaf.com Robert Nieminen lindarelth@trinityerd.com Beth McSorley (current) 1 Campus Drive Parsippany, NJ 07054 (973) 872-4421 bmcsorley@gaf.com Roofing Modified Bitumen Roof System Evaluation Report from a Florida Registered Arcl, rtectLicensed Florida Professional Engineer "* Evaluation Report - Hardcopy Received iSl Robert J.M. Nieminen PE-59166 UL LLC 04/22/2018 John W. Knezevich, PE ' Validation Checklist - Hardcopy Received FI5680 R17 GO 2W 01 C01 NiemineILM Standard ASTM D6162 ASTM D6163 ASTM D6164 ASTM D6222 FM 4470 FM 4474 TAS 114 2000 2000 2005 2008 1992 2004 2011 Equivalence of Product Standards hltpsJlwww.11oridabtilding.orgtpr/pr app dti.aspx?param=wGEVXQwtDgt45H1a2AP3lyZiwDnCBwg71Yk6HFX3SmiNtDs%2fyM8G6O%3d%3d 112 4/4/2017 Certified By Florida Building Code Online Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 12/14/2016 12/15/2016 12/19/2016 02/07/2017 Summry of P%ducts FL # Model, Number or Name-_� 5680.1 _GAF Modified Bitumen Roof Systems Descliptlon SBS and APP Modified Bitumen Roof Systems Limits of Use installation Instructions Approved for use in HVHZ: No FL5680 R17 II 2016 12 FINAL Al ER GAF MB F.L5680- Approved for use outside HVHZ: Yes Q1Z M i Impact Resistant: N/A Verified By: Robert Nleminen PE-59166 Design Pressure: +N/A/-465 Created by Independent Third Party: Yes 1 Other: 1.) The DP noted herein pertains to one specific Evaluation Reports I system. Refer to the ER Appendix for all systems and max. 5 D R17 AE 2016 12' FINAL FR t•1R FL{t ti✓ I1 design pressures. 2.) Refer to ER Section 5 for Limits of Use. 131L,1ist1 Created by Independent Third Party: Yes Contact us :: 7601 Bair Stmic! noad. Tallahassee Ft,J.2329 fP,yi t>t;: 1}50••tn7-tBz4 The Stdte of Florida is an AA/EEO employer. Convrnht 2007-7013 Stale of Ftmida.:: Privary Statement :: Accessibility Statement :: pnfund Sta1r_ment Under Florida law, email addresses are public remrds. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. 11 you have any questions, please contact 850.487.1395. 'Pursuant to Section 45S.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 45S, F.S. must pmvide the Department with an email address if they have one. The emarls provided may be used for official communication with the licensee. However email addresses are public record. If au do not wish to supply a personal address, please provide the Department with an email address whidi em be made available to the public. To determine ' ore a licensee under Chapter 455, F.S., please dick u•rp . Product Approval Accepts: o- Credit Card Safe hltpsllwww.Widalwilding.org/prlpr app d8.aspx7param=wGEVXQwtDgt45Hia2AP3lyZIwDnCBwg71Yk6HFX3SmiN(Ds%2fyM8G6Q%3d%3d 212 r�• TRINITY! ERD EVALUATION REPORT EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization N9503 353 Christian Street, Unit 13 Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 GAF Evaluation Report 01506.11.05-R17 1 Campus Drive FL5680-1117 Parsippany, N107054 Date of Issuance:11/07/2005 Revision 17:12/14/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the Sth Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: GAF Modified Bitumen Roof Systems LAeELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assura Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) cha a referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product ch . Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, t Ne product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a compl, fie eview of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'TRINITYI ERD Evaluated" may b + ' p d in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entiret INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manu its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 74-page Appendix. t� Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4ANE1983 CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity lERD does not have, nor does it intend to acquire or will it acqu any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, I.I.C. d/b/a TrinitylERD Is not owned, operated or controlled by any corn distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved In the product. S. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the De project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design t specifically for that purpose. e�A 5 OF The InClmllle trill ePpraring was authnrlrrd by gnhert Nlrminen, P E. at12/IA/101f.Ihisdor+nutscrveasmlrlectmnkallyliyncd dntumenl. 511plrrl, v!alyd kudcuplrs haw, Bern trantmmed to the f 1.ducl APumwl Adminlstralw and 1. the na—d client r r - , ` `f RINIT(' ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: GAF Modified Bitumen Roof Systems, as produced by GAF, have demonstrated compliance with the following sections of the 5'h Edition (2014) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Condition Use set forth herein. 2. STANDARDS: Section Propeft Standard Year :. 1504.3.1 Wind FM 4474 2004 1515.1.1 Wind TAS 114 2011 1504.7 Impact FM 4470 1992 1507,11.2 Physicals ASTM D6162 2000 1507.11.2 Physicals ASTM D6163 2000 1507.11.2 Physicals ASTM D6164 2005 1507.11-2 Physicals ASTM 06222 2008 3. REFERENCES: Enti Examination Reference Date EMU Examination ACRC (TST4671) TA5 114 ACRC 06 041 11/10/2006 FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 11 4 ACRC OG-042 11/14/2006 FM (TST1867) FM 4470/4474 ACRC (TST-1671) TAS 114 ACRC 06.043 11/m/mar, FM (TST1867) FM 4470/4474 ACRC (TST4671) TA5 114 ACRC (M-044 1111612.006 FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 06 0-18 12/21/2006 FM (TST 1867) FM 44 70/44 74 ACRC (TST4671) TAS 114 ACRC- 06 049 12/22/2006 FM (TST1867) FM 4470/4,374 ACRC(TST4671) TA5 114 ACRC OG-050 12/28/2006 FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 07.006 01/17/2007 FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 07.018 0.1/20/2007 FM (TST1867) FM 4470/4,174 ACRC(TST4671) TA5 114 ACRC07.028 05/08/2007 FM (TSTIBG7) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 07.030 05/09/I007 FM (TST1867) FM 4470/4474 ACRC (TST4671) TA5 114 ACRC 07.032 05/10/2007 FM (TST1867) FM 4470/4474 ACRC (TST4671) TA5114 ACRC07.033 05/10/2007 FM (TST1867) FM 4470/4474 ACRC (TST4671) TA5 I14 ACRC 07.041 011/31/2007 FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 07.044 09/05/2007 rM (TST1867) FM 4470/4474 ACRC (TST4671) TA5 114 ACRC 07.047 09/07/2007 FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 07.081 01/10/200H FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 07.082 01/11/2008 FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 08-024 04/18/2008 FM (TSTIBG7) FM 4470/4474 ACRC(TST4671) TAS 114 ACRC 08-034 05/19/2008 FM (TST18G7) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 08.044 07/01/2008 FM (TS71867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 11.043 08/08/2011 FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 11.046 08/09/2011 FM (TST1867) FM 4470/4474 ACRC(TST4671) TAS 114 ACRC 11.048 00/10/2011 FM (TST1067) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC I1.049 01111012011 FM (TST1RG7) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 11.050 06/11/2011 FM (TST-1110) FM 4470/4474 ACRC(TST4G71) TAS 114 ACRC 11.051 08/11/2011 rM (TST1867) FM 4470/4-174 ACHC(TST4671) TAS 114 ACRC 11.052 08/12/2011 FM (TST1867) FM 4470/4474 ACRC(TST4671) TAS 114 ACRC 11.053 08/17/2011 FM (TST1867) FM 4470/4474 ACRC(TST4671) TAS 114 ACRC 11-054 08/1.7/2011 FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 12.015 04/24/2012 FM (TST1867) FM 447014474 ACRC (TST4671) TAS 114 ACRC 12.026 05/10/2012 FM (TST1867) FM 4470/4474 AC11C (TST4671) TAS 114 ACRC 12.034 08/10/2012 FM (TST1867) FM 4470/4474 ACRC (TST4671) TAS 114 ACRC 12.035 08/13/2012 FM (TST1867) FM 4470/4474 ACRC(TST46711 TAS 114 ACRC 16-002 03/04/2016 FM (TST1867) FM 4470/4474 ERD (TST6049) rAS 114/FM4474 01880.09.03 09/10/2,003 FM ITST1867) FM 4470/4474 ERD (TST6049) TAS 114/FM4474 01516.04.06 04/20/2006 FM (TST1867) FM 4470/4474 ERO (TST6049) TAS 114/FM4474 4482.10.97-1 12/02/2006 FM (TST MR) FM 4470/4474 ERD (TST6049) TAS 114/FM4474 G4280LA6.10.06-111 12/06/2007 FM (1ST1867) FM 4470/4474 ERD (TST6049) Physical Properties G6850.08.08 08/0112008 FM (TST1867) FM 4470/4474 ERD (TST6049) Physical Properties G6850.08.08.1 03/29/2008 FM (TST1867) FM 447014474 ERD (TST6049) Physical Properties G6850.10.08 10/06/2008 FM (TST1867) FM 4476/4474 ERD (TST6049) Physical Properties GG850.11.08 11/05/2008 FM (TST1867) FM 4470/4474 ERD(TST60,19) Physical Properties G12210,06.09 08/03/2009 FM(T5T1867) FM 4470/4474 Exterior Research and Design, U.C. Certificate ojAathorlratton 99503 FSC NON-HVHZ EVALUATION Reference 3036225 3034978 797-05447.257 797.05487.267 797 05550 267 797.05538.267 797.05594.267 797.OS695-267 797-05683-267 797.05687.267 797.05748.267 3040738 3035960 797.06129.267 797.06177.267 797.06540.267 797.06800.267 797.07038.267 797-07073.267 3038128 3040738 3041535 3044688 797.07198.267 3044G88 (Ilc•Issuc) 3D44541 3044862 30439GO 3046280 3046388 3041769 3046403 3046054 3046081 797.0821 G7 797.082 ' 3047104 A 08/10/2009 09/17/2009 04/13/2010 OS/12/2010 05/25/2010 05/25/2010 06/01/2010 07/15/2010 07/21/2010 07/21/2010 08/10/2010 11/16/2010 11/30/2010 01/13/2011 03/16/2011 06/21/2011 09/29/2011 01/10/2012 01/19/2012 07/26/2010 11/16/2010 06/08/2011 03/01/2012 03/01/2012 03/16/2012 04/04/2012 05/11/2012 1/2012 1/2013 9/2013 797.0826 ' 67 05/23/2013 797.082 Y 05/23/I013 3047237 07/15/2013 797.086 6, 09/16/2013 797.08873-267 11/26/2013 3049871 12/11/2013 3048066 12/13/2013 Evaluation Renort 506.11.04-1117 r FL5680•R17 Revision 17:12/14/2016 Page 2 of 6 tl TRINITY ERD Entity Examination Reference Date Enti Examination Reference Date ERD (TST6049) Physical Properties G12210.01.10 01/00/2010 FM (T5T1867) FM 4470/4474 797.09016.267 12/17/2013 ERD (TST6049) PhysicalPropertles C31360.03.10 03/31/2010 FM (7ST1867) FM 4470/447A 3049496 12/19/2013 ERD (TST6049) Physical Properties G33470.01.11 01/13/2011 FM (T5T1867) FM 4470/4474 3049601 01/29/2014 ERDITST6049) TAS 114/FM4474 G3676D.07.11.1tl 107/19/2011 FM ITST1B67) FM 4470/4474 797-09984.267 10/28/2014 ERD (TST6049) Physical Properties G40620.07.12 2 07/17/2012 FM (TST1867) FM 4470/4474 797.09987-267 10/28/2014 ERD (TST6049) Physical Properties G43190.11.13.1 11/15/2013 FM (TST1867) FM 4470/4474 797-10017.267 11/06/2014 ERD (TST6049) Physical Properties G4063D.01.14-1 01/06/2014 FM (TST1867) FM 4470/4474 RR205568 06/15/2016 ERD (TST6049) Physical Properties G40630.01.14.2A 01/07/2014 FM (TST1867) FM 4470/4474 RR205474 08/31/2016 ERD(TST6049) Physical Properties G40630.01.14.2A•1 01/07/2014 FM (TST1867) FM 447014.174 3059483 12/09/2016 ERD(TSTG049) PhysicalPropertles G40630,01.14.28 01/07/2014 IRT(TST7408) TAS 124 00001 03/30/2000 LRD(TSTG049) Physical Properties G40630.01.14.2C 01/07/2014 IRT(TST7408) TAS 114 00002 03/30/200D ERD(TST6049) PhysicalPropertles G43180.01.14.1 01/10/2014 IRT(TST7408) TAS 114 01-039 01/24/2002 ERD(TST6049) TAS 114/FM4474 SC8580.11.15.3 11/09/2015 IRT(TST7408) TAS 114 02-005 01124/2002. ERD(TST6049) TAS 114/FM4474 SC8580.01.16.1 01/20/20IG IRT(TST7408) TAS 114 02.014 03/26/1..002, F-TEC(TST7393) TAS 114 08 050187 04/28/2008 IRT(TST7408) TAS 114 03.003 04/21/2003 F SEC (T'ST73931 TAS 114 08-050188 04/28/2008 IRT (TST7408) TAS 114 03.004 04/21/2003 F-TEC(TST7393) TAS 114 08-070077 07/25/2008 IRT(TST7408) TAS 114 D4.008 01/26/2004 F•TEC(TST7393) TAS 114 08.070084 07/25/2008 M-D (CER1592) Various Current NOAs Current F•TEC (TST7393) TAS 114 08.0501BIR 04/03/2009 MTI (TST2508) Physical Properties AXD4C9A 06/05/2009 F-TEC(TST7393) TAS 114 08-050186 10/14/2008 MlI(TST2508) Physical Properties Rx30C9C 07/09/2009 F•TEC(TST•7393) TAS 114 08.070226 10/14/20011 PHI(TST5878) Physical Properties GAF-027.02.01 03/26/2002 F•TCC(TST7393) TAS 114 08.070122 10/14/2008 PHI(TST5878) FM 4470/4.174 GAF•434-02.01 09/16/2013 F•TEC(TST7393) TAS 114 08.070127 10/14/2008 PRI(TST5878) FM 4470/4474 GAF-434.02.03 09/16/2013 F•TEC(TST7393) TAS 114 08-080077 11/17/2003 PHI(TST5878) FM 4470/4474 GAF-434.02.04 09/16/2013 FM (TST1867) FM 4470 109AS.AM 09/04/1997 PHI (TST5878) FM 4470/4474 GAF•436.02.02 03/06/2024 FM (TST1867) FM 4470 30075oo 06/15/2000 PHI(TSTSB78) FM 4470/4474 GAF•436-02.03 03/06/2014 FM (TST1867) FM 4470 3005640 11/09/2000 PHI(TST5878) FM 4476/4474 GAF-436.02.04 03/06/2014 FM (TST1867) FM 4470 3008178 12/27/2000 PHI(TST5878) FM 4470/4474 GAF-436.02.0 03/06/2014 FM (TST1867) F.Y.(TST1867) FM 4470 FM 4470 3010215 3009788 03/01/2001 03/28/2001 PHI(TST5878) PHI(TST5878) FM 4470/447-1 FM 4470/4474 GAF-436.02• 3/06/2014 GAF-436 02.09O�•�3/06/203A FM (TST1867) FN14470 30I1140 08/14/2001 PHI(TST5878) FtA 4470/4474 GAF•549.02.06 8/08/2014 FM (TST1867) FtJ14470 3013634 05/06/2002 PRI(T5T5878) FM 4470/4474 GAF•549.02-02 OR/ R/2014 FM (TST1867) FM 4470 30137BB 01/10/2003 PHI(TST5878) FM 4470/4474 GAF•559-02.01 fg 12014 FM (TSTI867) FM 4470 3014547 05/22/2003 Pill(TST5878) FM 4470/4474 GAF-559.02.05 W1 V�om FM (TST1867) FM 4470 3014692 08/05/2003 PHI(TST5878) FM 4470/4474 GAF-559-02-06 �y 10/16/201A FM ITST1867) FM 4470 30I4960 03/05/2004 PHIITST5678) FM 4470/4474 GAF•559.02.07 FM (TST1867) FM 4470/4474 3D17250 Q4/OS/2004 PRI(TSi5878) FM 4470/447A GAF-559.02.OB FM (TST1867) FM 4470/4474 3022139 05/26/2005 PRI(TST5878) FM 4470/4474 GAF•559.02.09 Collf64/21?% dS4 FM ITST1867) FM 4470/4474 3022508 07/20/2005 PHI(TST5878) FM 4470/4474 GAF-559.02.11 FM (TST1867) FM 4470/4474 3025023 12/14/2005 PHI(TST5878) FM 4470/4474 GAF-559.02-12 10/ 72014 FM ITST1867) FM 4470/4474 797.02095.267 04/26/2006 PRIITST5878) FM 4470/4474 GAF-559.02.13 10/ FM (TST1H67) FV14470/4474 3023458 07/18/2006 PRI(TST5878) FM 4470/4474 GAF•559.02.14 10/16/, FM (TST1867) FM 4470/4474 3028039 09/11/20OG PHI(TST58'7A) FM 4470/4474 GAF-559.02.15 30/1G/ OlA 'i FM (TST1867) FM 4470/4474 3024805 11/20/2006 PHI(TSTS876) FM 4470/4474 GAF-'559.02.16 10/16/2014 FM (TST1867) FM 4470/4474 3032388 10/30/2008 PHI(TST5878) FM 4470/4474 GAF-559.02.17 10/16/201 FM (T5T1867) FM 4470/4474 3032695 10/30/2008 PHI(TST5878) FM 4470/4474 GAF•559.02-1B 10/16/2014 FM (TST1867) FM 4470/4474 3D32943 11/06/2008 PHI(TST5878) FM 4470/4474 GAF-559.02.04•R1 03/04/2035 FM (TST1867) FM 4470/4474 3032811 22/11/2008 PHI(TST5878) FM 4470/4474 GAF-5S9.02.19 D4/17/2015 FM ITST1867) FM 4470/4474 3033719 01/iG/2009 UL(QUA9625) Quality Assurance Inspection(ALI 05/16/2016 FM(TST1867) FM 4470/4474 3035864 06/03/2009 UL(QUA9625) Quality Assurance Inspection (CAI) � f15/04/2o1G FM ITST1867) FM 4470/4474 3032172 06/12/2009 UL(QUA9625) Quality Assurance Inspection(CA2) r0K/05/2016 FM (TST1867) FM 4470/4474 3035140 08/20/2009 UL (QUA9625) Quallty Assurance Inspection (GA) 5/19/201G UL(QUA96251 Quality Assurance Inspection(IN) /22/2016 _j 4. PRODUCT DESCRIPTION: This Evaluation Report covers GAF Modified Bitumen Roof Systems installed in accordance i, j,G ` `published installation instructions and the Limitations / Conditions of Use herein. The following products e subject systems. Exterior Research and Design, U.C. Certificate of Authorirallon 09503 FBC NON-HVHZ EVALUATION r� Evaluation Report 01506.11.04-R17 FL5680•R17 Revision 17: 12/14/20IG Page 3 of 6 f TRINITY: ER® Ulm 1: ROLL -GOODS FOR GAF MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Type Grade GAFGLAS° H75 Base Sheet ASTM D4601 II N/A Tri-Ply" #75 Base Sheet ASTM D4601 II N/A GAFGLAS° 1180 Ultima'" Base Sheet A5TM D4601 II N/A Base Sheet StormSafe" Anchor Sheet Proprietary N/A N/A GAFGLAS* Stralavent° Nailable Venting Base Sheet ASTM D4897 II N/A GAFGLASO Stratavent" Perforated Venting Base Sheet ASTM D4897 II N/A Liberty" SBS Mechanically Attached Base Sheet Proprietary N/A N/A Ply Sheet GAFGLAS' Ply ASTM D2178 IV N/A Tri-Ply® Ply 4 ASTM D2178 IV N/A GAFGLAS" FlexPly"' 6 ASTM D2178 VI N/A Liberty'" SBS Self -Adhering Base/Ply Sheet ASTM D1970 N/A N/A UnderRoof"' 2 Polyester -Surfaced Leak Barrier ASTM D1970 N/A N/A UnderRoof " HT High Temperature Leak Barrier ASTM D1970 N/A N/A WeatherWatch" XT Mat Surfaced Leak Barrier ASTM D1970 N/A N/A Ruberoid' 20 Smooth ASTM D6163 I S Smooth Surfaced Ruberoid° HW 25 Smooth ASTM D6163 I S Membranes: Ruberoid' HW Smooth ASTM D6164 I S Ruberoid' Mop Smooth ASTM D6164 I S Ruberoid' Mop Smooth 1.5 ASTM D6164 I 5 Ruberoid® Mop Plus Smooth ASTM D6164 II S Ruberoid' Torch Smooth ASTM D6222 1 5 Tri-Ply° APP Smooth ASTM D6222 I S Ruberoid° 30 Granule ASTM D6163 I �G Ruberoid" 30 Granule FR ASTM D6163 I G Ruberoid' EnergyCap'" 30 Granule FR ASTM D6163 I G Liberty'" SBS Self -Adhering Cap Sheet ASTM D6164 I G Ruberoid" Mop Granule FR ASTM D6164 1 i —•G Ruberoid° Mop Granule ASTM D6164 I 1 G Intec Flex PRF ASTM D6164 I — 14 Tri-Ply° SBS Granule ASTM D6164 I &1111G Granule Surfaced Membranes: Ruberoid' HW Granule ASTM D6164 I Ruberoid® HW Granule FR ASTM D6164 Ip"i �� j G Ruberoid' Mop Plus Granule FR ASTM D6164 Il ; °" G Ruberoid" Mop Plus Granule ASTM D6164 II (t G Ruberoid' EnergyCapm Mop Plus Granule FR ASTM D6164 II I G Ruberoid' HW Plus Granule ASTM D6164 11 j G Ruberoid' HW Plus Granule FR ASTM D6164 II & G Ruberoid' EnergyCap'" HW Plus Granule FR ASTM D6164 II G Ruberoid' Torch Granule ASTM D6222 I `; G Tri-Ply' APP Granule ASTM D6222 I G Ruberoid" Torch Plus Granule FR ASTM D6222 II G Ruberoid' EnergyCap'" Torch Granule FR ASTM D6222 I G Ruberoid" EnergyCap'" Torch Plus Granule FR ASTM D6222 II G Exterior Research and Design, U.C. Evaluation Report 01506.11.04-R37 Cerd scare a/Autharization #9503 FBC NON-HVH2 EVALUATION F1.5680-R17 Revision 17:12/14/2016 Page 4 of 6 i TRINITY 1ERD S. LIMITATIONS: 5.1 This is a building' code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 2510. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD-1, RAS 117 and FM Loss Prevention Data Sheet 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zane 2/3 enhancements. 5.8 For fully -adhered insulation, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. t 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the e , ng roof system shall be capable of resisting project design pressures on its own merit to the satisfac' �n of the Authority Having Jurisdiction, as documented through field uplift testing in accordance w j�T 907, FM Loss Prevention Data Sheet 1-52 or TAS 124. �� 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind load.c once with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 1 ,J i � t the basic wind speed shall be determined from FBC Figure 1609. 5.13 All products In the roof assembly shall have quality assurance audit in accordance with t' F and F.A.C. Rule 611320-3. Exterior Research and Design, LLC. Certificate of Autbariratlon 119503 FBC NON-HVHZ EVALUATION Evaluation Report 01506.11.04•R17 FL5680-R17 Revision 17:12/14/2016 Page 5 of 6 t ' TRJNIT1 E D 6. INSTALLATION: 6.1 GAF Modified Bitumen Roof Systems shall be installed in accordance with GAF published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (847) 664-3281 - THE 74-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, I.I.C. Ccrtilltate olAutharlratlon #9503 FRC NON-HVH2 EVALUATION Evaluation Report 01506.21.04-R17 FLSGBD-R17 Revision 17: 12/14/2016 Page 6 of 6 QOTRINITYIERD APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND'UPLIFT.,RESISTANCE Table Deck Application Type * � tion Page 1A Wood New, Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 113-1 Wood New, Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 113-2 Wood New, Reroof (Tear -Off), Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 9 12 1C Wood New, Reroof (Tear -Off), Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 13 1D Wood New, Reroof (Tear -Off), Recover C Mech. Attached Insulation, Bonded Roof Cover 13 1E Wood New, Reroof (Tear -Off), Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 14 1F-1 Wood New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 14-15 SF-2 Wood New, Reroof (Tear -Off), Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16 2A-1 Steel or Structural concrete New, Reroof (Tear -Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 17-22 2A-2 Steel or Structural concrete New, Reroof (Tear -Off), Recover B-2 Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 23 2B-1A Steel or Structural concrete New, Reroof (Tear -Off), Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 24-32 2B-1B Steel or Structural concrete New, Reroof (Tear -Off), Recover C-1A Thermal Barrier with Vapor Barrier, Mech. Attached Insulation, Bonded Roof Cover 33 213-2 Steel or Structural concrete New, Reroof (Tear -Off), Recover C-2 Bonded and Mech. Attached Insulation, Bonded Roof Cover 33 2C Steel or Structural concrete New, Reroof (Tear -Off), Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 34-37 3A-1 Structural concrete New, Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 38-40 3A-2 Structural concrete New, Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 41-49 3B Structural concrete New, Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 49 4A LWIC New, Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 50-51 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52 4C LWIC New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 53-56 4D LWIC New, Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 56 5A CWF New, Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 57 5B CWF New, Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 58 5C CWF New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 59 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 60 6B Gypsum Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 60 6C Gypsum Reroof (Tear -Off) C Mech. Attached Insulation, Bonded Roof Cover 60 6D Gypsum Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 61 7A-1 Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 62-70 7A-2 Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 71-85 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation or base sheet attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood: Drill-Tec#12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3" Metal Plate. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report 01506.11.04-R18 for FL5680-R38 Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Revision 18: 04/12/2017 Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Appendix 1, Page 1 of 85 r 3. 4. 5. 6. 0i �v PY QOTRINITY ERD ➢ Steel: Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only); Drill-Tec ASAP 3S; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3" Metal Plate; Drill-Tec Extra Heavy Duty ASAP Roofing Fastener- Insulation. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural concrete: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3" Metal Plate. Minimum 1-inch embedment into pilot hole in accordance with the fastener manufacturer's published installation instructions. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral wool roof board that meets the OA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. VersaShield® Solo— Fire -Resistant Slip Sheet may be used as a non -load -bearing, fire -barrier slip -sheet component within any system outlined herein. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt: Full coverage at 25-30lbs/square ➢ OMG OlyBond 500 (OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. using PaceCart or SpotShot. Note: OlyBond Classic or OlyBond 500 Green may be used where OlyBond 500 is referenced. ➢ GAF LRF Adhesive M (LRF-M): Continuous 1-inch wide ribbons, 12-inch o.c ➢ Millennium One -Step Foamable Adhesive (M-OSFA): Continuous 1-inch wide ribbons, 12-inch o.c. ➢ GAF 2-Part Roofing Adhesive (GAF 2-Part): Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table. ➢ Hot asphalt: MDP -240.0 psf (Min. 0.5-inch thick) ➢ OlyBond 500 (OB500): MDP -292.5 psf (Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick EnergyGuard RH or RN) ➢ OMG OlyBond 500 (OB500): MDP -485.0 psf (Min. 0.5-inch thick EnergyGuard RA) ➢ GAF 2-Part Roofing Adhesive (GAF 2-Part): MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD-1. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is petmitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation, the existing roof surface shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or ANSI/SPRI IA-1. Exterior Research and Design, I.I.C. d/b/a Trinity)ERD Evaluation Report 01506.11.04-R18 for FL5680-R18 Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Revision 18: 04/12/2017 Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Appendix 1, Page 2 of 85 12. 13. - TRINITY I ERD Far Recover Applications using System Type D, the insulation is optional. Alternatively, min.fnc ergy �d Poly o Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN r I'a, Structodek High Density Fiberboard Roof Insulation, EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard NH HD Polyiso Insulation, EnergyGuard HD Plusoulation or EnergyGuard NH HD Plus Polyiso Insulation or min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board may be used as a separatof board prior to base sheet installation. The existing roof system shall be suitable for a recover application. The separator component shall be documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover in Recover applications. Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top- coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. 14. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. Reference Layer Material Application BP -AA Base: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet Hot asphalt at 25 Ibs/square. (Base/ Ply sheets, Asphalt -Applied) Ply: One or more plies GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6 Matrix- 102 SBS Membrane Adhesive BP -CA Base: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet (formerly known as TOPCOAT MATRIX 102 (Base/ Ply sheets, Cold -Applied) SBS Membrane Adhesive) at 1.5 gal/sq. B-LL Base: GAFGLAS Stratavent Perforated Venting Base Sheet Loose laid (Base sheet, Loose -Laid) Base or Ply: One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth SBS-AA Ruberoid 30 Granule, Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Smooth, Ruberoid Mop Hot asphalt at 25 Ibs/square. (SBS, Asphalt -Applied) Cap: Smooth 1.5, Ruberoid Mop Plus Smooth, Ruberoid Mop Granule FR, Ruberoid Mop Granule, Tri-Ply SBS Granule, Intec Flex PRF, Ruberoid Mop Plus Granule FR, Ruberoid Mop Plus Granule, Ruberoid EnergyCap Mop Plus Granule FR SBS-CA Ruberoid 20 Smooth Matrix- 102 SBS Membrane Adhesive (SBS, Cold -Applied, Matrix'" 102 SBS �!t Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Granule FR, Ruberoid Mop Plus Granule FR, know as T O C A (formerSBS Membrane Adhesive) Ruberoid EnergyCap Mop Plus Granule FR Membrane 1.5 gal/sq. Matrix- 101 Premium SBS Membrane Ruberoid 20 Smoothor Ruberoid Mop Smooth 1.5 Adhesive (formerly known as TOPCOAT SBS-CA-1 MATRIX Majorbond Modified Bitumen (SBS, Cold -Applied, Matrix— 101 Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop Membrane Adhesive) at 1.5-2.0 Premium SBS Membrane Adhesive) Cap: Plus Granule FR gal/square Base or Ply: One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth SBS-TA Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid (SBS, Torch -Applied) Cap: EnergyCap HW Plus Granule FR Torch applied Base or Ply: One or two plies Ruberoid Torch Smooth, Tri-Ply APP Smooth APP-TA Ruberoid Torch Granule, Tri-Ply APP Granule, Ruberoid Torch Plus Granule FR, Ruberoid EnergyCap Torch Granule FR, (APP, Torch -Applied) Cap: Ruberoid EnergyCap Torch Plus Granule FR Base or Ply: Liberty SBS Self -Adhering Base/Ply Sheet Self -adhered SBS-SA (self -adhering) Cap Liberty SBS Self -Adhering Cap Sheet Exterior Research and Design, LLC. d/b/a Trinity IERD Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Evaluation Report 01506.11.04-R18 for FL5680-1118 Revision 18: 04/12/2017 Appendix 1, Page 3 of 85 r- \J\TRINITYIERD 15. The following insulations are interchangeable within the scope of this Evaluation Repo ➢ EnergyGuard Polyiso Insulation b EnergyGuard NH Polyiso Insulation; ➢ EnergyGuard Ultra Polyiso Insulation b EnergyGuard NH Ultra Polyiso Insulation; ➢ EnergyGuard HD Polyiso Insulation b EnergyGuard NH HD Polyiso Insulation; ➢ EnergyGuard HD Plus Polyiso Insulation EnergyGuard NH HD Plus Polyiso Insulation. 16. Vapor barrier options for over structural concrete deck with adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A applies: VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A Option # Primer Vapor Barrier Insulation Adhesive MDP (psf) Type Attach VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch GR Torch -applied GAF 2-Part,12-inch o.c. -169.0 VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch -applied GAF 2-Part,12-inch o.c. -180.0 VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self -Adhering Cap Sheet Self -adhering GAF 2-Part, 12-inch o.c. -250.0 VB-4. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGGLAS FlexPly 6 Hot asphalt applied p pp GAF 2-Part, 12-inch D.C. -262.5 VB-5. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied GAF 2-Part, 12-inch o.c. -270.0 VB-6. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch -applied LRF-M, 12-inch o.c. -180.0 VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGGLAS FlexPly 6 Hot asphalt applied p LRF-M, 12-inch o.c. -495.0 VB-8. Matrix 307 Premium Asphalt Primer or ASTM D41 primer UnderRoof HT High Temperature Leak Barrier Self -adhering OlyBond 500, 12-inch o.c. -37.5 VB-9. Matrix 307 Premium Asphalt Primer or ASTM D41 primer UnderRoof 2 Polyester -Surfaced Leak Barrier Self -adhering OlyBond 500, 12-inch o.c. -127.5 VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch -applied OlyBond 500, 12-inch o.c. -165.0 VB-11. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth Torch -applied OlyBond 500, 12-inch o.c. -180.0 VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth Matrix 102 SBS Membrane Adhesive at 1.5 gal/square OlyBond 500, 12-inch o.c. y -202.5 VB-13. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch -applied OlyBond 500, 12-inch o.c. -232.5 VB-14. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGGLAS FlexPly 6 Hot as halt applied p pp OI Bond 500, 12-inch o.c. y -352.5 17. Vapor barrier options for over structural concrete deck followed by cellular lightweight insulating concrete carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Tables 4A through 4D applies: 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report 01506.11.04-R18 for FL5680-R18 Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Revision 18: 04/12/2017 Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Appendix 1, Page 4 of 85 QOTRINITYIERD TABLE 1A: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) - SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) y No. (Note 1) Type Attach Type Attach Base Ply Cap Min. 19/32-inch Min. 1.5-inch Min. 0.5-inch Structodek High (Optional) One or more SBS-AA, SBS TA or W-1. plywood or OSB at max. EnergyGuard RA, GAF 2-Part Density Fiberboard Roof GAF 2-Part BP -AA, SBS-AA BP -AA, SBS-AA, SBS-TA APP TA 52.5 24-inch span EnergyGuard RH, Insulation or APP-TA EnergyGuard RN Min. 19inch Min.1.5-inch EnergyGuard RA, Min. 0.25-inch Dens Deck, Dens Deck Prime or BP -AA, SBS-AA, SBS- (Optional) One or more SBS-AA, SBS-TA or 52.5 W-2. plywoodd or O56 at max. EnergyGuard RH, GAF 2-Part SECUROCK Gypsum Fiber GAF 2-Part TA or APP-TA BP -AA, SBS-AA, SBS-TA or APP-TA APP TA n 24-inch span EnergyGuard RN Roof Board Min. 19/32-inch Min. 1.5-inch EnergyGuard RA, Min. 0.25-inch Dens Deck, Dens Deck Prime or WeatherWatch XT Mat Surfaced Leak (Optional) SBS-TA, APP- SBS-TA, APP-TA -52.5 W-3. plywood or OSB at max. EnergyGuard RH, GAF 2-Part SECUROCK Gypsum -Fiber GAF 2-Part Barrier TA 24-inch span EnergyGuard RN Roof Board .TABLE 1B-1: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED D INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation777 Roof Cover (Note 14) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (Psf) 'CONVENTIONALS_YSTE_M5: Min. 1-inch Min. 0.5-inch 8-inch o.c. at EnergyGuard Polyiso Structodek High Min.-15/32- GAFGLAS #75 Base Sheet, 32 ga., 1- min. 4-inch laps Insulation, Density Fiberboard (Optional) inch Tri-Ply #75 Base Sheet, 5/8 inch dia. and 8-inch o.c. in EnergyGuard Ultra Hot Roof Insulation or Hot BP -AA, SBS- BP -AA, SBS-AA, W-4, plywood at GAFGLAS #80 Ultima Base tin caps with two, equally Polyiso Insulation or asphalt EnergyGuard Perlite asphalt AA SBS-AA, SBS-TA, -45.0 max. 24- Sheet, GAFGLAS Stratavent 11 ga. spaced, EnergyGuard RH Recover Board or Min. SBS-TA, APP-TA inch span Nailable Venting Base annular ring staggered center Polyiso or min. 1.5- 0.75-inch EnergyGuard APP-TA Sheet, Ruberoid 20 Smooth shank nails rows inch EnergyGuard RA Perlite Roof Insulation or EnergyGuard RN (homogeneous) Min. 1-inch 8-inch o.c. at EnergyGuard Polyiso Min.15/32- GAFGLAS #75 Base Sheet, 32 ga., 1- min. 4-inch laps Insulation, Min. 0.25-inch Dens (Optional) inch Tri-Ply #75 Base Sheet, 5/8-inch dia. and 8-inch o.c. in EnergyGuard Ultra Hot Deck Prime or Hot BP -AA SBS- BP -AA, SBS-AA, W-5. plywood at GAFGLAS #80 Ultima Base tin caps with two, equally q y Polyiso Insulation or y asphalt p SECUROCK Gypsum- yp asphalt p AA, SBS-TA, SBS-AA, SBS-TA, -45.0 max. 24- Sheet, GAFGLAS Stratavent 11 ga. spaced, EnergyGuard RH Fiber Roof Board APP-TA SBS-TA, APP-TA inch span Nailable Venting Base annular ring staggered center Polyiso or min. 1.5- APP-TA Sheet, Ruberoid 20 Smooth shank nails rows inch EnergyGuard RA or EnergyGuard RN Exterior Research and Design, LLC. d/b/a Trinity[ERD Evaluation Report 015Ub.11.U4-R18 for PLbbSu-K1b Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Revision 18: 04/12/2017 Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Appendix 1, Page 5 of 85 TABLE 16-1: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) System Deck Attach Base Ply Cap No. (Notes) Type GAFGLAS #80 Ultima Base Fasteners 32 ga., 1- Attach 9-inch o.c. at the Type Min. 1-inch EnergyGuard Polyiso Attach Type Min. 0.5-inch Structodek High Density Fiberboard (Optional) Min. 19/32- Sheet, GAFGLAS Stratavent 5/8-inch dia. min. 4-inch lap Insulation, Roof Insulation or BP -AA, SBS-AA, inch Eliminator Nailable Venting tin caps with and 12-inch o.c. EnergyGuard Ultra Hot EnergyGuard Perlite Hot BP -AA, SBS- SBS-AA, SBS-TA, W-6. plywood at Base Sheet, Ruberoid 20 11 a. B in two, equally Polyiso Insulation or asphalt Recover Board or Min. asphalt AA SBS-TA, APP-TA max. 24- Smooth, Ruberoid Mop annular ring spaced, EnergyGuard RH 0.75-inch EnergyGuard APP-TA inch span Smooth, Ruberoid Mop shank nails staggered center Polyiso or min. 1.5- RA Perlite Roof Insulation Smooth 1.5 GAFGLAS #80 Ultima Base 32 ga., 1 rows 9-inch o.c. at the inch EnergyGuard or EnergyGuard RN Min. 1-inch EnergyGuard Polyiso (homogeneous) (Optional) Min. 19/32- Sheet, GAFGLAS Stratavent 5/8-inch dia. min. 4-inch lap Insulation, Min. 0.25-inch Dens BP -AA, SBS- BP -AA, SBS-AA, inch Eliminator Nailable Venting tin caps with and 12-inch o.c. EnergyGuard Ultra Hot Deck Prime or Hot AA, SBS-TA, SBS-AA, SBS-TA, W-7, plywood at Base Sheet, Ruberoid 20 11 ga. in two, equally Polyiso Insulation or asphalt SECU ROCK Gypsum- asphalt APP-TA SBS-TA, APP-TA max. 24- Smooth, Ruberoid Mop annular ring spaced, EnergyGuard RH Fiber Roof Board APP-TA inch span Smooth, Ruberoid Mop shank nails staggered center Polyiso or min. 1.5- RA Min. 15/32- Smooth 1.5 GAFGLAS #75 Base Sheet, 32 ga., 1- 5/8-inch rows 6-inch o.c. at the inch EnergyGuard or EnergyGuard RN Min. 1-inch EnergyGuard Polyiso Insulation, Min. 0.5-inch Structodek High Density Fiberboard (Optional) inch Tri-Ply #77 5 Base Sheet, diameter tin 4-inch lap and 6- EnergyGuard Ultra Hot Roof Insulation or Hot BP -AA, SBS- SBS-AA, W-8, plywood at GAFGLAS #80 Ultima Base caps with 12 inch o.c. in two Polyiso Insulation or asphalt P EnergyGuard Perlite asphalt AA SBS-A, SBS-AA, SBS-TA, APP-TA max. 24- Sheet, GAFGLAS Stratavent ga. annular staggered center EnergyGuard RH Recover Board or Min. SBS-TA, inch span P Nailable Venting Base Sheet, Ruberoid 20 Smooth ring shank rows Polyiso or min. 1.5- RA 0.75-inch EnergyGuard Perlite Roof Insulation APP-TA Min. 15/32- GAFGLAS #75 Base Sheet, nails 32 ga., 1- 5/8-inch 6-inch o.c. at the inch EnergyGuard or EnergyGuard RN Min. 1-inch EnergyGuard Polyiso Insulation, (homogeneous) Min. 0.25-inch Dens (Optional) inch Tri-Ply #75 Base Sheet, diameter tin 4-inch lap and 6- EnergyGuard Ultra Hot Deck Prime or Hot BP -AA, SBS- SBS-AA, W-9. plywood at GAFGLAS #80 Ultima Base caps with 12 inch o.c. in two Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt AA SBS-TA, SBS-BP-AA, SBS-AA, SBS-TA, max. 24- Sheet, GAFGLAS Stratavent ga. annular staggered center EnergyGuard RH Fiber Roof Board APP-TA SBS-TA, APP-TA inch span Nailable Venting Base ring shank rows Polyiso or min. 1.5- APP-TA Sheet, Ruberoid 20 Smooth nails inch EnergyGuard RA or EnergyGuard RN Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report 01506.11.04-R18 for FL5680-R18 Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Revision 18: 04/12/2017 Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Appendix 1, Page 6 of 85 System I Deck o. N(Note 1) W-10. W-11. W-12. W-13 NVI �- Q0".1NITYIERD ,TABLE 16-1: WOOD DECKS �C I tfCrlO OR REROOF (TEAR -OFF) SYSTEM TYPE A-2: ,MECHANICALLY ATTACHED .,NCF[OR�EET, BONDED INSULATION, BONDED ROOF COVER , Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP Fasteners Attach Type Attach Type Attach Base I Ply I Cap (Psf) Min. 19/32- GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, inch GAFGLAS #80 Ultima Base plywood at Sheet, GAFGLAS Stratavent max. Nailable Venting Base inch span Sheet, Ruberoid 20 Smooth GAFGLAS #75 Base Sheet, /32- Tri-Ply #75 Base Sheet, inch inch GAFGLAS #80 Ultima Base plywood at Sheet, GAFGLAS Stratavent max. 24 Nailable Venting Base inch span Sheet, Ruberoid 20 Smooth GAFGLAS #80 Ultima Base Min. 19/32- Sheet, GAFGLAS Stratavent inch Eliminator Nailable Venting plywood at Base Sheet, Ruberoid 20 max. 24- Smooth, Ruberoid Mop inch span Smooth, Ruberoid Mop Smooth 1.5 GAFGLAS #80 Ultima Base Min. 19/32- Sheet, GAFGLAS Stratavent inch Eliminator Nailable Venting plywood at Base Sheet, Rubero)d 20 max. 24- Smooth, Ruberoid Mop inch span Smooth, Ruberoid Mop Smooth 1.5 BASE PLY: Exterior Research and Design, I.I.C. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Min. 1-inch Min. 0.5-inch 32 ga., 1- EnergyGuard Polyiso Structodek High 5/8-inch 8-inch o.c. at the Insulation, Density Fiberboard (Optional) diameter tin 4-inch lap and 8- EnergyGuard Ultra Hot Roof Insulation or Hot BP -AA, SBS- BP -AA, SBS-AA, caps with 12 inch o.c. in two Polyiso Insulation or asphalt EnergyGuard Perlite asphalt AA SBS-AA, SBS-TA, -52.5 ga. annular staggered center EnergyGuard RH Recover Board or Min. SBS-TA, APP-TA ring shank rows Polyiso or min. 1.5- 0.75-inch EnergyGuard APP-TA nails inch EnergyGuard RA Perlite Roof Insulation or EnergyGuard RN (homogeneous) Min. 1-inch 32 ga., 1- EnergyGuard Polyiso 5/8-inch 8-inch o.c. at the Insulation, Min. Dens BP -AA SBS- (Optional) BP -AA, SBS-AA, diameter tin caps with 12 4-inch lap and 8- inch o.c. in two EnergyGuard Ultra Polyiso Insulation or Hot Prime Deck Prime or SECUROCK Gypsum- Hot asphalt AA, SBS-TA, SBS-AA, SBS-TA, -52.5 ga. annular staggered center EnergyGuard RH asphalt Fiber Roof Board APP-TA SBS-TA, APP-TA ring shank rows Polyiso or min. 1.5 APP-TA nails inch EnergyGuard RA or EnergyGuard RN Min. 1-inch Min. 0.5-inch 9-inch o.c. at the EnergyGuard Polyiso Structodek High 32 ga., 1- min. 4-inch lap Insulation, Density Fiberboard 5/8-inch dia. and 9-inch o.c. in EnergyGuard Ultra Hot Roof Insulation or Hot BP -AA, SBS- BP-A(Optional) SBS-AA, tin caps with two, equally Polyiso Insulation or asphalt EnergyGuard Perlite asphalt AA SBS-A, SBS AA, SBS-TA, 60.0 11 ga. spaced, EnergyGuard RH Recover Board or Min. SBS-TA, APP-TA annular ring staggered center Polyiso or min. 1.5- 0.75-inch EnergyGuard APP-TA shank nails rows inch EnergyGuard RA Perlite Roof Insulation or EnergyGuard RN (homogeneous) Min. 1-inch 9-inch o.c. at the EnergyGuard Polyiso 32 ga., 1- 5/8-inch dia. min. 4-inch lap and 9-inch o.c. in Insulation, EnergyGuard Ultra Min. Dens BP -AA SBS- (Optional) BP -AA, SBS-AA, tin caps with two, equally Polyiso Insulation or Hot asphalt Deck Prime or Prime SECUROCK Gypsum- Hot asphalt AA, SBS-TA, SBS-AA, SBS-TA, -60.0 11 a. g spaced, EnergyGuard RH Fiber Roof Board APP-TA SBS-TA, APP-TA annular ring staggered center Polyiso or min. 1.5- APP-TA shank nails rows inch EnergyGuard RA or EnergyGuard RN FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems GAF; (800) 766-3411 Evaluation Report 01506.11.04-R18 for FLS680-R18 Revision 18: 04/12/2017 Appendix 1, Page 7 of 85 N �-� TRINITY I ERD TABLE 113-1: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation 7717 Roof Cover (Note 14) MDP f) No. (Noted Type Fasteners Attach Type Attach Type Attach Base Ply Cap (ps GAFGLAS #80 Ultima Base Min.19/32- Sheet, GAFGLAS Stratavent inch Eliminator Nailable Venting W-14. plywood at Base Sheet, Ruberoid 20 max. 24- Smooth, Ruberoid Mop inch span Smooth, Ruberoid Mop Smooth 1.5 GAFGLAS #80 Ultima Base Min.19/32- Sheet, GAFGLAS Stratavent inch Eliminator Nailable Venting W-15. plywood at Base Sheet, Ruberoid 20 max. 24- Smooth, Ruberoid Mop inch span Smooth, Ruberoid Mop Smooth 1.5 I VENTING SYSTEMS: W-16. inch /32- inch plywood at max. 24- inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth GAFGLAS #80 Ultima Base Min. 19/32- Sheet, GAFGLAS Stratavent inch Eliminator Nailable Venting W-17. plywood at Base Sheet, Ruberoid 20 max. 24- Smooth, Ruberoid Mop inch span Smooth, Ruberoid Mop Smooth 1.5 GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, inch/32- inch GAFGLAS #80 Ultima Base W-18. plywood at Sheet, GAFGLAS Stratavent max. 24- Nailable Venting Base inch span Sheet, Ruberoid 20 Smooth Exterior Research and Design, LLC. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Min. 1-Inch 9-inch o.c. at the EnergyGuard Polyiso 32 ga., 1- min. 2-inch lap Insulation, 5/8-inch dia. and 12-inch o.c. EnergyGuard Ultra tin caps with in two, equally Polyiso Insulation or 11 ga. spaced, EnergyGuard RH annular ring staggered center Polyiso or min. 1.5- shank nails rows inch EnergyGuard RA or EnergyGuard RN Min. 1-inch 9-inch o.c. at the EnergyGuard Polyiso 32 ga., 1- min. 2-inch lap Insulation, 5/8-inch dia. and 12-inch o.c. EnergyGuard Ultra tin caps with in two, equally Polyiso Insulation or 11 ga. spaced, EnergyGuard RH annular ring staggered center Polyiso or min. 1.5- shank nails rows inch EnergyGuard RA or EnergyGuard RN 8-inch o.c. at Min. 1-inch 32 ga., 1- min. 4-inch laps EnergyGuard Polyiso 5/8-inch dia. and 8-inch o.c. in Insulation, tin caps with two, equally EnergyGuard Ultra 11 ga. spaced, Polyiso Insulation or annular ring staggered center EnergyGuard RH shank nails rows Polyiso 9-inch o.c. at the Min. 1-inch 32 ga., 1- min. 4-inch lap EnergyGuard Polyiso 5/8-inch dia. and 12-inch o.c. Insulation, tin caps with in two, equally EnergyGuard Ultra 11 ga. spaced, Polyiso Insulation or annular ring staggered center EnergyGuard RH shank nails rows Polyiso 6-inch o.c. at Min. 1-inch 32 ga., 1- min. 4-inch laps EnergyGuard Polyiso 5/8-inch dia. and 6-inch o.c. in Insulation, tin caps with two, equally EnergyGuard Ultra 11 ga. spaced, Polyiso Insulation or annular ring staggered center EnergyGuard RH shank nails rows Polyiso Hot asphalt Hot asphalt Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum - Fiber Roof Board Min. 0.25-inch Dens Deck Prime or SECU ROCK Gypsum - Fiber Roof Board (Optional) I SBS-SA, Hot I SBS-SA I SBS-TA I TA APP TA asphalt BS TA or or APP- Weather (Optional) Hot WatchXT -SBS-TA, Mat Surfaced SBS-TA, APP-TA asphalt APP-TA Leak Barrier Hot (Optional) Additional s layer(s) base asphalt B-LL asphalt insulation p Hot (Optional) Additional Hot layer(s) base B-LL asphalt insulation asphalt Hot I (Optional) Additional asphalt layer(s) base insulation FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems GAF; (800) 766-3411 Hot B-LL asphalt (Optional) BP -AA, SBS-AA (Optional) BP -AA, SBS-AA (Optional) BP -AA, SBS-AA -45.0 -45.0 SBS-AA 1 -45.0 SBS-AA 1 -45.0 SBS-AA 1 -52.5 Evaluation Report 01506.11.04-R18 for FL5680-R38 Revision 18: 04/12/2017 Appendix 1, Page 8 of 85 4 ` J TRINITY f ERD TABLE 1B-1:.WOOD DECKS —NEW CONSTRUCTION ORREROOF (TEAR -OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP No. (Notes) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (Psfl 32 ga.,1- Min. 1-inch Min. 19/32- GAFGLAS #75 Base Sheet, 5/8-inch 8-inch o.c. at the EnergyGuard Polyiso inch Tri-Ply #75 Base Sheet, diameter tin 4-inch lap and 8- Insulation, Hot (Optional) Additional Hot (Optional) W-19. plywood at GAFGLAS #80 Ultima Base caps with 12 P inch o.c. in two EnergyGuard Ultra asphalt layer(s) base asphalt B-LL BP -AA, SBS-AA 52.5 max. 24- Sheet, GAFGLAS Stratavent g a annular staggered center gg Polyiso Insulation or y insulation SBS-AA inch span Nailable Venting Base ring shank rows EnergyGuard RH Sheet, Ruberoid 20 Smooth nails Polyiso GAFGLAS #80 Ultima Base 32 ga., 1- 9-inch o.c. at the Min. 1-inch Min. 19/32- inch Sheet, GAFGLAS Stratavent Eliminator Nailable Venting dia. min. 4-inch lap and 9-inch o.c. in EnergyGuard Polyiso Insulation, (Optional) Additional (Optional) W-20. plywood at Base Sheet, Ruberoid 20 t5/8-inch n caps with i two, equally EnergyGuard Ultra Hot asphalt layers) base Hot asphalt B-LL BP -AA, SBS-AA -60.0 max. 24- Smooth, Ruberoid Mop 11 a. g annular ring spaced, Polyiso Insulation or insulation SBS-AA inch span Smooth, Ruberoid Mop shank nails staggered center EnergyGuard RH Smooth 1.5 rows Polyiso TABLE 113-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR-OFF)OR RECOVER TYPE A=2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER .''SYSTEM System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (Psf) CONVENTIONAL SYSTEMS: - - Min. 0.5-inch Min. 1-inch Structodek High Density GAFGLAS #75 Base Sheet, 12-inch o.c. at the EnergyGuard Polyiso Fiberboard Roof (Optional) (Optic Min. 19/32- Tri-Ply #75 Base Sheet, min. 4-inch lap Insulation, EnergyGuard Insulation or SBS AA, inch GAFGLAS #80 Ultima Base Note 2 and 12-inch o.c. in Ultra Polyiso Insulation Hot EnergyGuard Perlite Hot BP -AA, SBS-AA, SBS-TA, -45.0 W-21. plywood at Sheet, GAFGLAS Stratavent two, equally or EnergyGuard RH asphalt Recover Board or Min. asphalt SBS-AA SBS-TA, APP TA max. 24- Nailable Venting Base spaced, staggered Polyiso or min. 0.75-inch EnergyGuard APP-TA inch span Sheet, Ruberoid 20 Smooth center rows EnergyGuard RA or Perlite Roof Insulation EnergyGuard RN (homogeneous) Min. 1-inch GAFGLAS #75 Base Sheet, 12-inch o.c. at the EnergyGuard Polyiso (Optional) Min. 19/32- Tri-PI #75 Base Sheet, y min. 4-inch lap Insulation, EnergyGuard Min. 0.25-inch Dens BP -AA, BP -AA, SBS-AA, inch GAFGLAS #80 Ultima Base and 12-inch o.c. in Ultra Polyiso Insulation Hot Deck Prime or Hot SBS-AA, SBS-AA, SBS-TA, -45.0 W-22. plywood at Sheet, GAFGLAS Stratavent Note 2 two, equally or EnergyGuard RH asphalt SECUROCK Gypsum- asphalt SBS-TA, SBS-TA, APP-TA max. 24- Nailable Venting Base spaced, staggered Polyiso or min. 1.5-inch Fiber Roof Board APP-TA APP-TA inch span Sheet, Ruberoid 20 Smooth center rows EnergyGuard RA or EnergyGuard RN Exterior Research and Design, L-C. d/b/a Trinity)ERD Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Evaluation Report 01506.11.04-R38 for FL5680-1118 Revision 18: 04/12/2017 Appendix 1, Page 9 of 85 TRINITY I ERD TABLE 16-2: WOOD DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (Psf) Min. 0.5-inch Min. 1-inch Structodek High Density Min. 15/32- GAFGLAS #75 Base Sheet, 16-inch o.c. at the EnergyGuard Polyiso Fiberboard Roof (Optional) inch Tri-Ply #75 Base Sheet, Note 2 min. 4-inch lap Insulation, EnergyGuard Insulation or BP -AA, SBS-AA, GAFGLAS #80 Ultima Base (#14 and 16-inch o.c. in Ultra Polyiso Insulation Hot EnergyGuard Perlite Hot BP -AA, SBS-AA, SBS-TA, -52.5 W-23. plywood at Sheet, GAFGLAS Stratavent ONLY ) two, equally or EnergyGuard RH asphalt Recover Board or Min. asphalt SBS-AA SBS-TA, APP-TA Nailable Venting Base spaced, staggered Polyiso or min. 1.5-inch 0.75-inch EnergyGuard APP-TA inch span Sheet, Ruberoid 20 Smooth center rows EnergyGuard RA or Perlite Roof Insulation EnergyGuard RN (homogeneous) Min. 1-inch GAFGLAS #75 Base Sheet, 16-inch o.c. at the EnergyGuard Polyiso (Optional) Min.15/32- Tri-Ply #75 Base Sheet, min. 4-inch lap Insulation, EnergyGuard Min. 0.25-inch Dens BP -AA, BP -AA SBS-AA, inch GAFGLAS #80 Ultima Base Note 2 and 16-inch o.c. in Ultra Polyiso Insulation Hot Deck Prime or Hot SBS-AA, SBS-AA, SBS-TA, -52.5 W-24. plywood at Sheet, GAFGLAS Stratavent ONLY) ONLY) two, equally or EnergyGuard RH asphalt SECUROCK Gypsum- asphalt SBS TA, SBS-TA, APP-TA max. 24- Nailable Venting Base spaced, staggered Polyiso or min. 1.5-inch Fiber Roof Board APP-TA APP-TA inch span Sheet, Ruberoid 20 Smooth center rows EnergyGuard RA or EnergyGuard RN Min. 0.5-inch Min. 1-inch Structodek High Density Min. 15/32- GAFGLAS #75 Base Sheet, 12-inch o.c. atthe EnergyGuard Polyiso Fiberboard Roof (Optional) Tri-Ply #75 Base Sheet, Note 2 min. 4-inch lap Insulation, EnergyGuard Insulation or BP -AA, SBS-AA, inch GAFGLAS #80 Ultima Base (#14 and 12-inch o.c. in Ultra Polyiso Insulation Hot EnergyGuard Perlite Hot BP -AA, SBS-AA, SBS-TA, -60.0 W-25. plywood at Sheet, GAFGLAS Stratavent ONLY ) two, equally or EnergyGuard RH asphalt Recover Board or Min. asphalt SBS-AA SBS-TA, APP-TA Nailable Venting Base spaced, staggered Polyiso or min. 1.5-inch 0.75-inch EnergyGuard APP-TA inch span Sheet, Ruberoid 20 Smooth center rows EnergyGuard RA or Perlite Roof Insulation EnergyGuard RN (homogeneous) Min. 1-inch GAFGLAS #75 Base Sheet, 12-inch o.c. at the EnergyGuard Polyiso (Optional) Min. 15/32- Tri-Ply #75 Base Sheet, min. 4-inch lap Insulation, EnergyGuard Min. 0.25-inch Dens BP -AA, BP -AA, SBS-AA, inch GAFGLAS #80 Ultima Base Note 2 and 12-inch o.c. in Ultra Polyiso Insulation Hot Deck Prime or Hot SBS-AA, SBS-AA, SBS-TA, -60.0 W-26. plywood at Sheet, GAFGLAS Stratavent two, equally or EnergyGuard RH asphalt SECUROCK Gypsum- asphalt SBS-TA, SBS-TA, APP-TA Nailable Venting Base ONLY) ONLY) spaced, staggered Polyiso or min.1.5-inch Fiber Roof Board APP-TA APP TA inch span Sheet, Ruberoid 20 Smooth center rows EnergyGuard RA or EnergyGuard RN Exterior Research and Design, LLC. d/b/a Trinity IERD Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Evaluation Report 01506.11.04-R38 for FL5680-R18 Revision 18: 04/12/2017 Appendix 1, Page 10 of 85 w;At'A �: np'�7.4'91 no 7fv 6\Q TRINITY ERD TABLE 113-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation I Top Insulation Roof Cover (Note 14) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (psf) Min. 0.5-inch Min. 1-inch Structodek High Density GAFGLAS #75 Base Sheet, 12-inch o.c. at the EnergyGuard Polyiso Fiberboard Roof (Optional) (Optic Min. 19/32- Tri-Ply #75 Base Sheet, min. 2-inch lap Insulation, EnergyGuard Insulation or SBS-AA, inch GAFGLAS #80 Ultima Base Note 2 and 12-inch o.c. in Ultra Polyiso Insulation Hot EnergyGuard Perlite Hot BP -AA, SBS-AA, SBS-TA, -60.0 W-27. plywood at Sheet, GAFGLAS Stratavent three, equally or EnergyGuard RH asphalt Recover Board or Min. asphalt SBS-AA SBS-TA, APP-TA max. 24 Nailable Venting Base spaced, staggered Polyiso or min. 1.5-inch 0.75-inch EnergyGuard APP-TA inch span Sheet, Ruberoid 20 Smooth center rows EnergyGuard RA or Perlite Roof Insulation EnergyGuard RN (homogeneous) Min. 1-inch GAFGLAS #75 Base Sheet, 12-inch o.c. at the EnergyGuard Polyiso (Optional) Tri-Ply #75 Base Sheet, min. 2-inch lap Insulation, EnergyGuard Min. 0.25-inch Dens AA, BP -AA, SBS-AA, inch/32- inch GAFGLAS #80 Ultima Base and 12-inch o.c. in Ultra Polyiso Insulation Hot Deck Prime or Hot SB SBS-AA, SBS-AA, SBS-TA, -60.0 W-28. plywood at Sheet, GAFGLAS Stratavent Note 2 three, equally or EnergyGuard RH asphalt SECUROCK Gypsum- asphalt SBS TA, SBS-TA, APP TA max. 24- Nailable Venting Base spaced, staggered Polyiso or min. 1.5-inch Fiber Roof Board APP-TA APP-TA inch span Sheet, Ruberoid 20 Smooth center rows EnergyGuard RA or EnergyGuard RN Drill-Tec Min. 1-inch GAFGLAS #75 Base Sheet, 3" Ribbed 12-inch o.c. at the EnergyGuard Polyiso Min. 15/32- Tri-Ply #75 Base Sheet, Galvalum min. 4-inch lap Insulation, EnergyGuard Min. 0.75-inch (Optional) inch GAFGLAS #80 Ultima Base a Plate and 12-inch o.c. in Ultra Polyiso Insulation Hot EnergyGuard Perlite Hot BP -AA SBS-AA -67.5' W-29. plywood at Sheet, GAFGLAS Stratavent (Flat) with two (2), equally or EnergyGuard RH asphalt Insulation asphalt SBS-BP-AA. SBS-AA SBS-AA max. 24- Nailable Venting Base Drill-Tec spaced, staggered Polyiso or min. 1.5-inch inch span Sheet, Ruberoid 20 Smooth #14 center rows EnergyGuard RA or Fasteners EnergyGuard RN Min. 0.5-inch Min. 1-inch Structodek High Density Min. 15/32- GAFGLAS #75 Base Sheet, 8-inch o.c. at the EnergyGuard Polyiso Fiberboard Roof (Optional) inch Tri-Ply #75 Base Sheet, Note 2 4-inch lap and 8- Insulation, EnergyGuard gy i Ultra Polyiso Insulation Hot Insulation or Hot BP -AA, BP -AA, SBS-AA, : W-30. plywood at GAFGLAS #80 Ultima Base (#14 inch o.c. in three y or EnergyGuard RH asphalt EnergyGuard gYGuard Perlite asphalt SBS-AA SBS-AA, SBS-TA, -75.0 max. 24 Sheet, GAFGLAS Stratavent ONLY) staggered center Polyisomin.RA inch Recover Board or Min. SBS-TA, APP-TA inch span Nailable Venting Base Sheet, Ruberoid 20 Smooth rows EnergyGuard RA orc 0.75-inch EnergyGuard Perlite Roof Insulation APP TA EnergyGuard RN (homogeneous) Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report 01506.11.04-R18 for FL5680-R18 Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Revision 18: 04/12/2017 Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Appendix 1, Page 11 of 85 �TRINITYJERD TABLE 1B-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR-OFF)OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (Psi Min. 1-inch Min. 15/32- GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, 8-inch o.c. the EnergyGuard Polyiso Insulation, EnergyGuard gY Min. 0.25-inch Dens BP -AA, (Optional) BP -AA, SBS-AA, inch GAFGLAS #80 Ultima Base Note 2 (#14 n 4-inch lap and 8- inch o.c. in three Ultra Polyiso Insulation Y Hot Deck Prime or Hot SBS-AA, SBS-AA, SBS-TA, -82.5 W-31. plywood at Sheet, GAFGLAS Stratavent ONLY) staggered center Guard RH or EnergyGuard gY halt asphalt SECUROCK Gypsum- asphalt SBS-TA, SBS-TA, APP-TA max. 24- Nailable Venting Base Polyiso or min. 1.5 inch Fiber Roof Board APP-TA APP-TA inch span Sheet, Ruberoid 20 Smooth rows EnergyGuard RA or EnergyGuard RN VENTING SYSTEMS: - GAFGLAS #75 Base Sheet, 16-inch o.c. at the Min. 1-inch Min. 15/32- Tri-Ply #75 Base Sheet, min. 4-inch lap EnergyGuard Polyiso One or SBS-AA, inch GAFGLAS #80 Ultima Base Note 2 and 16-inch o.c. in Insulation, EnergyGuard Hot (Optional) Additional Hot B-LL more BP - SBS-TA, 52.5 W-32. plywood at Sheet, GAFGLAS Stratavent (#14 two, equally Ultra Polyiso Insulation asphalt layer(s) base insulation asphalt AA, SBS- APP-TA max. 24- Nailable Venting Base ONLY ) spaced, staggered or EnergyGuard RH AA inch span Sheet, Ruberoid 20 Smooth center rows Polyiso GAFGLAS #75 Base Sheet, 12-inch o.c. at the Min. 1-inch Min. 15/32- Tri-Ply #75 Base Sheet, Note 2 min. 4-inch lap EnergyGuard Polyiso One or SBS-AA, inch GAFGLAS #80 Ultima Base and 12-inch o.c. in Insulation, EnergyGuard Hot (Optional) Additional Hot B-LL more BP- SBS-TA, 60.0 W-33. plywood at Sheet, GAFGLAS Stratavent (#14 two, equally Ultra Polyiso Insulation asphalt layer(s) base insulation asphalt AA, SBS- APP-TA max. 24- Nailable Venting Base ONLY ) spaced, staggered or EnergyGuard RH AA inch span Sheet, Ruberoid 20 Smooth center rows Polyiso Min. 15/32- GAFGLAS #75 Base Sheet, 8-inch o.c. the Min. 1-inch EnergyGuard Polyiso gY Y One or inch Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Note 2 n lap and 8- Insulation, EnergyGuard Hot (Optional) Additional Hot B-LL more BP- SBS-AA, SBS-TA, 82.5* W-34. plywood at Sheet, GAFGLAS Stratavent (#14 inch o.c. in three inch Ultra Polyiso Insulation asphalt layer(s) base insulation asphalt AA, SBS- APP-TA max. 24- Nailable Venting Base ONLY) staggered center or EnergyGuard RH � AA inch span Sheet, Ruberoid 20 Smooth rows Polyiso Exterior Research and Design, LLC. d/b/a Trinity ) ERD Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Evaluation Report 01506.11.04-R18 for FL5680-1118 Revision 18: 04/12/2017 Appendix 1, Page 12 of 85 Q0 - TRINITY I ERD r TABLE 1C: WOOD DECKS --NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP System No. (Note 1) Type Fasteners Attach Type Attach Base Ply Cap (Psf) Drill-Tec #12 Fastener with (Optional) Min. 19/32-inch plywood Min. 1-inch Drill-Tec AccuTrac Flat 1 per 1.78 Min. 0.25-inch SECUROCK SBS-TA, W-35. OB500 SBS-SA SBS-TA, APP-TA -52.5 at max. 24-inch span EnergyGuard RN Plate or AccuTrac ft2 Gypsum -Fiber Roof Board APP-TA Recessed Plate Drill-Tec #12 Fastener with WeatherWatch XT (Optional) Min. 19/32-inch plywood Min. 1-inch Drill-Tec AccuTrac Flat 1 per 1.78 Min. 0.25-inch SECUROCK SBS TA, W-36. OB500 Mat Surfaced Leak SBS-TA, APP TA -52.5 at max. 24-inch span EnergyGuard RN Plate or AccuTrac ft2 Gypsum -Fiber Roof Board Barrier APP-TA Recessed Plate TABLE 11): WOOD DECKS - NEW CONSTRUCTION, REROOF (TEaR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED_ ROOF COVER System Deck Top Insulation Layer Roof Cover (Note 14) MDP No. ( Note 1 ) Base Insulation Layer Type Fasteners Attach Base Ply Cap Ps CONVENTIONAL SYSTEMS: - Min. 0.75-inch, one or more BP AA SBS (Optional) BP- SBS-AA, Min.19/32-inch plywood at Min. 1.5-inch EnergyGuard Composite or Note 2 1 per 3 ft2 AA, SBS-AA, SBS-TA, -45.0 W_37, layers, any combination, loose Ener Guard RA Composite max. 24-inch span laid � p SBS-TA, APP-TA APP TA Min. 0.75-inch, one or more Min. 1-inch Structodek High Density Min(Optional) BP- SBS-AA, 19/32-inch at Fiberboard Roof Insulation or min. 0.75- BP-AASB . plywood S- W_38, layers, any combination, loose inch-EnergyGuard Guard Perlite Roof Insulation Note 2 1 per 2 ft2 AA AA, SBS-AA, SBS-TA, 45.0 max. 24-inch span gy SBS-TA, APP-TA APP-TA laid (homogeneous) BP -AA, SBS- (Optional) BP- SBS-AA, W-39 Min. 19/32-inch plywood at (Optional) One or more layers, Min. 0.25-inch SECUROCK Gypsum Fiber Note 2 (#14 only) 1 per 1.78 ft2 AA, SBS-TA, AA, SBS-AA, SBS-TA, -60.0 max. 24-inch span any combination, loose laid Roof Board APP-TA SBS-TA, APP-TA APP TA SELF-AoNERING BASE PLY:., rW-4O. Min.15/32-inch plywood at (Optional) One or more layers, Min. 1.5-inch EnergyGuard RA, Note 2 (HD 1 per 2 ft2 SBS-SA (Optional) SBS-SBS-SA -45.0 max. 24-inch span any combination, loose laid EnergyGuard RH, EnergyGuard RN Fasteners only) SA Drill-Tec#12 O tlonal SBS- SBS-TA, Min.15/32-inch plywood at (Optional) One or more layers, Min.1.5-inch EnergyGuard Polyiso 2( P )Fasteners and Drill- 1 per 1.78 ftSBS-SA TA, APP-TA APP-TA-52.5 max. 24-inch span any combination, loose laid Insulation, EnergyGuard Ultra Tec 3" Steel PlatesDrill-Tec #12 SBS- SBS-TA,Min.15/32-inch plywood at (Optional) One or more layers, Min. 1.5-inch EnergyGuard Polyiso Fasteners and Drill- 1 per 1.6 ftZ SBS-SA (Optional) -60.0 max. 24-inch span any combination, loose laid Insulation, EnergyGuard Ultra TA, APP-TA APP-TA Tec 3" Steel Plates Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report 01506.11.04-R18 for FL5680-R18 Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Revision 18: 04/12/2017 Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Appendix 1, Page 13 of 85 \� I TRINITY I ERD TABLE 10-1: WOOD DECKS - NEW CONSTRUCTION oR REROOF (TEAR -OFF) SYSTEM TYPE E: "NON -INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER Base Sheet Roof Cover (Note 14) MDP System Deck (Note 1) Type Faster Attachment Ply Cap (Psfl No. LONVENTIONALWbIM13: - Min. 15/32-inch W-46. plywood at max. 24-inch span Min. 19/32-inch W-47, plywood at max. 24-inch span Min.19/32-inch W-48. plywood at max. 24-inch span Min.15/32-inch W-49. plywood at max. 24-inch span Min. 19/32-inch W-50. plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 32 ga., 1-5/8-inch dia. tin Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base caps with 11 ga. annular Sheet, Ruberoid 20 Smooth ring shank nails GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent 32 ga., 1-5/8-inch dia. tin Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, caps with 12 ga. annular Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 ring shank nails GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 32 ga., 1-5/8-inch dia. tin Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base caps with 11 ga. annular Sheet, Ruberoid 20 Smooth ring shank nails 32 ga., 1-5/8-inch dia. tin GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base caps with 11 ga. annular Sheet, Ruberoid 20 Smooth ring shank nails GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 32 ga, 1-5/8-inch dia. tin Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base caps with it ga. annular Sheet, Ruberoid 20 Smooth ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch (Optional) o.c. in two, equally spaced, staggered BP -AA, SBS- SBS-AA -45.0 center rows AA 9-inch o.c. at min. 4-inch laps and 9-inch (Optional) o.c. at two, equally spaced, staggered BP -AA, SBS- SBS-AA -45.0 center rows AA SBS-AA, 9-inch o.c. at min. 4-inch laps and 12-inch BP -AA, SBS- SBS-TA, O.C. in two, equally spaced, staggered AA SBS-CA, -45.0 center rows APP-TA 6-inch o.c. at min. 4-inch laps and 6-inch (Optional) o.c. in two, equally spaced, staggered BP -AA, SBS- SBS-AA -52.5 center rows AA SBS-AA, 9-inch o.c. at min. 4-inch laps and 9-inch BP -AA SBS- SBS-TA, o.c. in two, equally spaced, staggered AA SBS CA, -52.5 center rows APP-TA Exterior Research and Design, I.I.C. d/b/a TrinityjERD FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Certificate of Authorization #9503 GAF; (800) 766 3411 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R18 for FL5680-1118 Revision 18: 04/12/2017 Appendix 1, Page 14 of 85 TABLE 1F-1: WQOD DECKS SYSTEM TYPE E: ' NON -INSULATED, ME( System o Deck (Note 1) Min. 19/32-inch Type GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent W-51. plywood at max. Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, 24-inch span Min. 19/32-inch Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent W-52. plywood at max. Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, 24-inch span Min.19/32-inch Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent OEM. plywood at max. Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, 24-inch span BASE PLY: Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 u SELF -ADHERING Min.19/32-inch W-54. plywood at max. Liberty SBS Mechanically Attached Base Sheet 24-inch span Min.15/32-inch W-55. plywood at max. Liberty SBS Mechanically Attached Base Sheet 24-inch span �A9f.' r: TRINITY ERD - NEW CONSTRUCTION oR REROOF,(TEAR-OFF) .HANICALY FASTEDED BASE SHEET, BONDED ROOF COVER, Base Sheet Roof Cover (Note 14) MDP Faster Attachment Ply Cap (psf) 32 ga., 1-5/8-inch dia. tin 9-inch o.c. at min. 4-inch laps and 9-inch (Optional) caps with 11 ga. annular o.c. in two, equally spaced, staggered APP-TA APP-TA -60.0 ring shank nails center rows 32 ga., 1-5/8-inch dia. tin 8-inch o.c. at min. 4-inch laps and 8-inch (Optional) caps with 12 ga. annular o.c. at three, equally spaced, staggered BP -AA, SBS- SBS-AA -75.0 ring shank nails center rows AA SBS-AA, 32 ga., 1-5/8-inch dia. tin 7-inch o.c. at min. 4-inch laps and 7-inch BP -AA SBS- SBS-TA, caps with 11 ga. annular o.c. in three, equally spaced, staggered AA SBS-CA, t 82.5 ring shank nails center rows APP-TA 32 ga., 1-5/8-inch dia. tin 9-inch o.c. at min. 4-inch laps and 9-inch (Optional) SBS-SA, caps with 11 ga. annular o.c. in two, equally spaced, staggered SBS SA SBS-TA or -37.5 ring shank nails center rows APP-TA 32 ga., 1-5/8-inch dia. tin 8-inch o.c. at min. 3-inch laps and 8-inch SBS-SA, (Optional) caps with 11 ga. annular o.c. in three, equally spaced, staggered SBS-SA SBS-TA or -45.0 tine shank nails center rows I APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity JERD Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION; GAF Modified Bitumen Roof Systems Prepared by: Robert Nieminen, PE-59166 GAF; (800) 766-3411 Evaluation Report 01506.11.04-R18 for FI-5680-1118 Revision 18: 04/12/2017 Appendix 1, Page 15 of 85