HomeMy WebLinkAboutScreen Enclousure DetailsEmit 3' x 3' x 0230' MIN. 6063-T6 ALLOY PLATE OR STRONGER (ONE SIDE) WITH (3) - 012 x V' S.M.S, EACH SIDE AS SHOWN (%' MIN. PLATE EDGE DISTANCE L C-C FASTENER SPACING) 3' x 2' x 0.050' 14UL 6C63-T6 ALLOY PLATE,OR STRONGER (ONE SIDE) (3) - M12 iC '4 SN.S, EACH SIDE•1 AS SHOWN (W MIN. PLATE EDGE DISTANCE ;6 C=C FASTENER SPACWW FOUNDATION (5) /12x3/4' S.M.S. 1x2 O.B. ATU1CHED TO BEAM W/ (2)-/10X2- S.N.S. INTO SCREW BOSS W/�Y4/ NUT "AND WASHERBOLT // EACH SIDE OF BEAM 112x2" S.M.S. O 24' O.C. Ix2 O.B. TO SUPER GURER (1) /12x3/4- S.M.S. BEAM f OR SLOPED) --� CORNER POST CORNER POST K-BRACE V x 2' JSOLE PLATE V O CONCRETE ANCHOR C2 PLACES) IN LIEU OF TYP. Y4' O CONCRETE SCREWS FOR CORNER COLUMN (4) #12x3/4' S.M.S.— EACH LEG. 5' or 7' SUPER GUTTER MIN. 0.090' THICK E_ RAIL V x 2' O.B. PATIO SECTION (I1 TOTAL) - #12 x Y4 SJLS AS SHOWN 06' MIN. PLATE EDGE DISTANCE C-C FASTENER SPACING) 6' x 5' x 6063-T6 ALLOY PLATE (ONE SIDE) OR STRONGER K-BRACE —I 2x3xO.070 CHAIR RAIL K-BRACE K-BRACE LATERAL V- - BRACING CONNECTION`DETAILS Ix5x)fi' ANGLE 6' LONG CTYP, B EACH BEAM) -(2) Y4'Ox3' LG 8 EACH ANGLE ROOF BEAM TO SUPER GUTTER CONNECTION DETAIL NOTES PRIMARY ATTACHED TO H CONVENTIONAL i- FACIA TO BE 2x6 (MIN.) S.P.F. OVERHANG NO T OR WESTER RED CEDAR 11 NOTED IN PLAN STRUCTURAL GRADE 2 MIN, (1) %-0x2' LG LAG SCREW B 24' O.C. ENTIRE LENGTH OF GUTTER SECURE FASCIA TO EACH RAFTER TAIL W/ (1) LG10x4' LONG PAN HEAD LAG SCREWS BEFORE ATTACHING SUPER GUTTER (1) Y4'Ox2' LG. LAG SCREWS COO 1 CTYP. 2 EACH BEAM) I� / ci) M12x2' SJLS a 12' O.C. (MAX) BETWEEN BEAMS ANGLETHICK CONTINUOUS COLUMN GIRT CC HAIR RAIL) r SEE ELEVATION FOR 'K' BRACE SIZE , ,C _ ==BEAM 'STITCHING=SCREWS (SEE TABLE) @ 24' QC, SPLICE PLATE (EACH SIDE IIF BEAM) SPACE SCREWS A A 5052-H32 ALLOY OR EQUAL, 1/8' THICKNESS EQUALLY (TYP.) ,• = i A �' (^ �r y P� 114x%' SCREWS �p (r) 1 (am) COMM) (rrrr) ti LINE LINE SCREWS PLATE 1 vpD ,k*3I4 �jll BEAM 'A• •B'a'C' TOTAL WIDTH 2x4 3 2 24 12' y;Q vPD VN P tOSN (!2x5 "137 ^3-- "32 14' . 2x6 4 3 40 14' 2x7 5 4 56 16' 'MO 2x8 5 5 64 16' E9(H 5 6 72 19' ROOF BEAM 6 7 BB 1s' �����,' /CONNECTION DETAIL 7 7 96 18• ST. LUCIE couNTY BLIM`INC Dr% _ N RgVIEVVEU FOR v (3) �12x14' S.M.S., EACH LEG AND NUN. (4) /IOx3' LONG S.N.S. INTO SCREW BOSSES (TYP. ALTERNATIVE) �6) /12x1¢' S.M.S. CHANNEL TO BEAM 9) SCREW TOTAL I)Fkl __ - . ST BE IK EPT ON JQ� PLANS AND PE. GIR NO INVE,CTION WILL BE MADE. 1xIA' BY 2" LONG ANGLE, EACH SIDE (TYP.) 2x3x0.070 GIRT/CHNR RAI (SEE PLAN) t 1I�I MIN. (4) LONG 1 (45#R1444- S.M.S., IV �\ S.M.S. I SCREW BOSSES' Cr-. ALTERNATIVE) 2 EACH LEG (TYP.) S.N.B. POST HOLLOW POST PLANS AND ALL PROPOSED WOr- AFM SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT e, MAY BE NECESSARY IN ORDER TO CHAIR RAIL / GIIIL'f�LL APPLICABLE CODES. I CONNECTION DETAIL (2) /IOx4- S.M.S. THRU. 2x3 -_ SAVE RAIL INTO PURUN SCREW BOSSES USE 0100)6' S.M.S. O 24. O.C. - TO CONNECT TO ix2 O.B. TO 2x3. 1x2 O.B. FASTENED TO COLUMN/POS W/(2) 010x0j" S,(I.S. INTO SCREW BOSSE: (EACH END, TYP. SECURE FASCIA TO EACH RAFTER TAIL W/ (1) Yi Ox4' LOG PAN HEAD LAG SCREWS BEFORE ATTACHING SUPER GUTTER J110x3/4' S.N.S. Yi CONTINUOUS BEAD OF CONSTRUCTION O 2' O.C. ADHESIVE DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED A 41 BEAM STITCHING O 24 O.C. . CO) (IYP. TOP AND BOTTOM OF SMB J 2x3xO.070 PURUN,;�-� SEE TABLE FOR SIZES) Q W C 0 W U ixlxlif' BY 3' LONG rn O IED RECIENNG CHANNEL ANGLE, EACH SIDE M.) Cy J MATERWL THICKNESS) V ' x 2 1/a" x 1" x 3" LG. (3) F1242 S.M.S.. EACH LEG (6) TOTAL (TYP.) Z. fYP. ALIFRNJITIVE) to Li 1t7s � ),T' 2 z W 2x3xO.O45 EAVERAIL ATTACHED TO BEAMS WITH (3)-j10x2- S.M.S. •_�J, PURUN INTO SCREW BOSS. (NAY BE SLOPED OR -FLAT)----- 2x5x.125 WIDE WITH INTO#UPRIGHT. " INTO 0 BE(2)fMA & (2)-Ii4x1 USE /10x%-, S.M.S. O 24' O.C. TO CONNECT TO 1x2 O.B. TO 20. PURUN FASTENED TO COLUMN/POST (9) 1112xV4' S.M.S. EACH SIDE - WITH (4) /12x1- S.M.S. (EACH LEG) OF BEAM (TYP.) OR USING Va" THICK FIAT BAR BENT / [6) �12xYs' S.M.S. EACH SIDE TO FR (6D63-T6 ALLOY) / F FJJJ FOR 2x5 COLUMN TO 2x5 BEAM COLUMN/POST evx �iuu/w SIDEWALL_POST / COLUMN TO PURLIN CONNECTION DETAIL C Z R' a o � PURLIN TO BQQF.~ J TENEAS ON ATTACHMENTS CONNEC L w 0 AMC ME ESPONSIBIUTYOFTHE a J w CONTRACTOR OF RECORD d o �: DRAWN BY: DYK CHECKED BY: DYK 5' a S.N.B. BEAN SCALE: AS SHOWN - > MAY BE SLOPED OR FLAT Kt (SEE PLAN FOR SIZE) DATE 5111105 J 3 J MIN DO YEON KIM, P.E. 1 FLA. REG. NUMBER 49497 SPACING OF STENERS (TYP,) DISDGE TIANICC(TYP.) MAIN POST / COLUMN TO ROOF BEAM" ���� l A CONNECTION DETAIL DO KIAP.S ,LLC 33879 16 `f-17 ring No. - 060811 SHEET 1OF3 3' MIN. SEE PLAN FOR SIZE/ 1x2 O.B. FASTENED TO COR E SECTION WITH /14x0j" SIM.S.1 24' O.C. 2x2x%" ANGLE 2" LONG (EACH W/(Z) J14xY4" S.M.S. TO POS & 3/8 0 H.D. GALV. EXP. SOL W/ 2 1/2' MIN. EMBEDMENT PURUN SUPPORT COLUMN/POST )b' ANGLE, EACH SIDE (TYP.) 2x2x1/8" x 2' I.G. ANGLE W/ (4) /12x3/4" S.M.S (EACH SIDE) %'0 CONCRETE ANCHOR S.M.S. WITH MIN. ' EDGE DISTANCE � %'0 CONCRETE ANCHOR W/2%* EMBEDMENT INTO STRUCTURAL CONCRETE (TYP.. ��rr��••��ss��EE��F�F� NOTE 10) \. / 1"x2' O.B. SOLE PLATE W/2%" EMBEDMENT INTO STRUCTURAL CONCRETE (EACH SIDE) t� •a J Z 0eW Y4 0x2Y4 CONCRETE SCREW ANCHOR\O 24' O.C. z ORU AND 9' FROM POST (TYP.) D' 0,04 0 " . . .: . ■rs EDGE OF CONCRETE f-1' (TYPJ a W N PLAN VIEW LW' U i IdQ� cWz UOa ;TO CONCRETE_,-i CONNECTION -DETAIL Ya" ANGLE, EACH SIDE (TYP.) S.M,S. WITH MIN. ' EDGE DISTANCE %'0 CONCRETE ANCHOR W/2%" EMBEDMENT INTO ' STRUCTURAL CONCRETE (TYP., ^ L SEE NOTE 10) 1'z2' O.B. SOLE PLATE is CU5 f J 3" MIN. (TYP.) J zix W Ys Ox2Yi CONCRETE / T ai SCREW ANCHOR O 24" O.C. u c u Z AND 9" FROM POST (TYP.) BEAM SUPPORT COLUMN/POST 2x2x1/8' x 2' LG. ANGLE ,W/ (4) /12x3/4' S.M.S (EACH SIDE) �i / POST — 9, COLUMN/POSTaD I 1x2 O.B. SOLE PL ATE ---- O O o �— I' (TYP.) EDGE OF\CONCRETE N z a PLAN VIEW MAIN COLUMN TO CONCRETE CONNECTION DETAIL �aY 2"x PURUN BEAM MAY BE FLAT OR SLOPED O DIAGONAL ROOF ION 2x2z)b" ANGLE CUP, CUT AT I A 45' (+/-),,ANGLE AND ATTACHED TO THE SCREEN ROOF BEAM WITH ONEI(1) Y4 0 THRU- WITH /-� !i BOLT, FENDER WASHER. ATTACHED TO BEAM OR EAVE RAIL /( DIAGONAL BRACING SHALL NOT BE ATTACHED TO ROOF PURUNS. \� 2x2x0.093 BRACE (SEE PLAN) N � COLUMN 214" MAX. THICK BRICK PAVERS SET IN MORTAR ON TOP OF FOOTER a O.B. SOLE PLATE Z N Y' 0x5" CONCRETE SCREWS O 24" O.C. 2)(S' MIN. CONC. (TYP.), 1)¢' CONC. EMBEDMENT (MIN.) EMBEDMENT (TYP.) TYPCIAL FRONT VIEW OF POST TO FOUNDATION CONNECTION WITH PAVERS 4' NOMINAL CONCRETE SLAB (2500 PSI, MIN.) W/6x6x1O/IO W.W.M. OR FIBER REINFORCED (POLYPROPYLENE FIBER - 1.5 POUND (MIN.)PER C.Y,) • d' c . ♦ d 44 L A `UNDISTURBED SOIL OR COMPACTED _ CRUSHED UMEROCK (90S PROCTOR) MIN. (1)-/5 REBAR CONTINUOUS, SPLICE MUST OVERLAP 20' MIN. 3' COVER (TYP.) FOUNDATION/SLAB DETAIL v 1x3 0.6. FASTENED TO CORNER SECTION WITH /10x2" S.M.S. W/ %" DIA WASHER O 18' O.C. 2x5xW ANGLE (2' LONG) V/ (2)-N14 TEKS INTO TOP OF 2x3 EAVE RAIL AND (2)- N14 TEKS INTO THE FRONT OF THE CORNER POST �-1x2 O.B. TOP FRAME CORNER POST -Ix O.B. SIDE WALL CORNER UPRIGHT ELEVATION VIEW CORNER POST / COLUMN UPRIGHT DETAIL d 0 ' d APPROXIMATE q/ G a d a d O d. � a • e d PSI MIN. CONCRETE STRENGTH COMPACTED OR UNDISTURBED SOIL/SAND ,(1)—#5 REBAR, CONTINUOUS 3" MIN. CONC. COVER, 36" MIN. III �'�Ipl�l y�lr LAP SPLICE I� �1I2�"�—MMIN.* MIN. CONTINUOUS PERIMETER FOOTING (4) /12x314" 2'x PURUN BEAM MAY BE FLAT OR SLOPED (2) /104h (TYR EACH PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 RNATE (1) i' ANGLE E A- ANGLE (BRACE) W/ h 2xY4 S.M.S. O EACH ER INTERSECTION 6" ANGLE 2' LONG ON RSIDEW/(4) /12x-Y4' S.M.S. LEG (BEAM k BRACE) 3RACE PLAN) ALTERNATE (2) 20 BRACE DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 251 ISSUED 0 0 0 C 0 W Q' U N O r_ Q J Z V W Z C Z � o a c) Z U U W J W } U � � DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: a/11/06 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM & ASSOCIATES, LLC 2 87 Pf x OD39 T. F 33679 vw ue copy Drawing No. - 060811 SHEET 2 OF 3 Genera[ Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318, 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary, 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 7005-T53 Alloy, 6005-T5 Alloy; for secondary components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted, SMB shall be stitched with #100/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum (4)-#10x2" per connection unless shown otherwise. 8. Unless otherwise shown, screws shall have minimum edge distance and center -to -center distances as shown in this table. C-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 5/15' 1/2" #12 0.219 3/81"1 9/16 I #14 (1/4") 0.250 1/2" 5/8" 9. Structure has been designed to meet the 5rh Edition FBC (2014 FBC). Project is sited where the ultimate design wind speed, V'At, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure B. Design pressures are from Table 2002.4, 2014 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASO). 10. Concrete anchors may be "Large Diameter Tapcons" (LTOs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 IoI2m I ISSUED c 13 w o U O = J a>' U Z CO) w Lu c z W a O ~ J w C-) a U Lu DRAWN BY. DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: All1106 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM f OCIATES, LLC 87 ox 0039Ta, FL 33679 File, Cop I Drawing No. - 060811 I SHEET 3 OF 3