HomeMy WebLinkAboutApproved Revision Letter - 54 Villas Del NorteBRADEN & BRADEN, A.I.A. P.A.
417 COCONUT AVENUE, STUART, FLORIDA 34996
TELEPHONE: (772) 287-8258 FAX: (772) 287-8283
March 4, 2022
St. Lucie County Building Department
Permit #: 2106-0732
RE: 54 Villa Del Norte
To whom it may concern,
Please note, the mullion to be used on this project is PGT mullion 1" x 2.75" x 0.375" tube mull attached per sheet 2 of
product approval FL# 261.1 through 1"x buck into solid filled concrete block walls and lintels using %" tapcons with 2" edge
distance and 2" embedment into solid filled CMU per Chart 3B in approval.
If you have any questions, please feel free to call me at (772) 287-8258.
Thank you,
Daniel R.
Braden
Digitally signed by
Daniel R. Braden
Date: 2022.03.04
13:25:40-05'00'
Daniel R. Braden
Braden & Braden AIA PA