Loading...
HomeMy WebLinkAboutLetter- Manufacturer Certificationf pS ' l FLA 1Aanulactuied Swiding Program 1840 NoM•Monfoe$ueet Profess�nal Tallahassee, Florida 32399.0772 �CC]ll�cltiQil Pbone:850,487.1824• Fax. 850A14.8436 Ken Lawson, Secretary August 22, 2016 Robert Moore Lark Builders, Inc. P.O. Drawer 629 Vidalia, GA 30475 v RE: Manufacturer Certification, ID MFT-114; Expiration Date; August 22, 2019 Dear Robert Moore It is my pleasure to Inform you that Lark Builders, Inc., located at 409 DIXON STREET, P O DRAWER 629, VIDALIA, GA 30475, has been approved under the Manufactured Buildings Program, as provided for under Chapter 553, Part I, Florida Statutes, to manufacture Factory Built Schools, Storage Sheds, Manufactured Buildings for Installation In Florida. Construction or modification on a manufactured building cannot begin until the Third Party Agency has approved the plans in accordance with the current Florida Building Code. Your Third Party Agency is a contractor for the Department and has statutory authority and responsibilities that must be met to maintain approved status. You may expect and demand quality plans review and Inspections. Each Code change will make your plans obsolete until they have been reviewed, approved and Indicated [on the cover page of the plans] for compliance with the Code by your Third Party Agency for plans review. Please ensure that your plans are in compliance and are properly posted on our website. All site -related Installation Issues are subject to the local authority having jurisdiction. The Department's contractor will make unannounced monitoring visits at least once each year. You must grant complete access to your manufacturing facility and records to remain in compliance with the rules and regulations of this program. Your certification Is approved for three years from this date. You will receive a renewal notice by Email generated by the BCIS:f4+iuvtv:florl8afiulliiina','ora) for online renewal, If you have questions you may contact Robert Lorenzo at 850-717-1835 or our FAX at 850-414-8436. Please visit our website at www.floridabuilding,ora to see valuable Information on the Florida Manufactured Buildings Program. A copy of this letter must accompany applications for local building permits. Sincerely, ;,.(�'G { Robert Lorenzo Manufactured Buildings Program cc; Professional Service Industries Rick Scott, Covemor PSI APPROVAL 2015-05-24 160 mph - Metal Lapsider Box Eave shed Master Plan GENERAL NOTES: Lark Builders DE5IGN.PARAMETER5: (HIP -GABLE ROOF) [WIND DESIGN PER A5CE 7-10. SEISMIC DE51GN PER A15C 341-051 I . THIS STRUCTURE WA5 DESIGNED IN ACCORDANCE WITH THE 2009 IBC BUILDING CODE AND THE FLOM DA BUI LDI NG CODE. WI NO LOADING DESIGNED IN ACCORDANCE WITH THE ASCE - 7-10. 2. ALL MATERIALS AND LABOR SHALL BE IN ACCORDANCE -WITH THE ABOVE CODE AND ALL OTHER APPLICABLE LOCAL CODES AT THE TIME OF MANUFACTURE. 3. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER 5CALED DIMENSION. 4. OUTSIDE OVERALL DIMEN51ON5 CAN VARY BETWEEN LIMITS 5HOWN BUT MEMBER'5PACINGSHALL NOT EXCEED LIMITS AS INDICATED. 5. LUMBER USED FOR CONSTRUCTION SHALL BE AS FOLLOWS: FLOOR JOISTS- 2x45:Y.P-.#2-(12-15%.MOI5TURECONTENT) 2x6 5.Y.P.#2-(12-15% MOISTURE CONTENT) 2z8 5.Y.P.#2-(12- 15% MOISTURE CONTENT) G. ALL OF THE FOLLOWING LUMBER SHALL BE PRE95URE TREATED: SKIDS, FLOOR JOISTS AND 3/4' TCG FLOOR SHEATHING 7. TPU55 DESIGNED TO SUPPORT D_.L.+L.L.=30 P.5.F. 8. HANDICAP ACCE55TO BUILDING 15 FIELD INSTALLED BY OTHERS AND SUBJECT TO LOCAL JURISDICTION APPROVAL. 9. ALL ALUMINUM TO BE 3005-3105 ALLOY WITH 32,000 F51 MINIMUM YIELD STRENGTH. 10. ROOF 5LOPE:5HALL BE 3:12 WHEN SHINGLES ARE A.PFUED, SEE FBC 1507.2 FOR5HINGLE REQUIREMENTS. ROOF SLOPE FOR METAL ROOFS SMALL MEET MANUFACTURER'5'RE66tv1MENDATI6N5. 11. ROOF RAFTERS SHALL HAVE THE 5AME 5PACING A5 THB4VALL STUDS AND SHALL BE LOCATED DIRECTLY OVER THE WALL STUD. 12. ROOF SLOPE5 BETWEEN 2:12 AND 4:12 SHALL, HAVE A DOUBLE UNDERLAYMENT APPLICATION IN ACCORDANCE WITH`5ECLION 1507.2.8 OF THE F.B.C. 201 O 13. ANCHORS SHALL MEET THE REQUIREMENTS OF ALL APPLICABLE LOCAL CODES AND THI5 15 NOT A FOUNDATION DESIGN. 14. BUILDING 15 CLASSIFIED AS TYPE "5' (STORAGE). 15. ALUMINUM WINDOWS.- TYPE, SIZE, QUANTITY, AND LOCATION MAY VARY. I G. ALL FASTENERS INTO P.T. WOOD15HALL.BE HOT DIPPED GALVANIZED FASTENERS: 17. MANUFACTURER INSTALLATION.5TANDARD5 SHALL BE FOLLOWED IN ORDER FOR THESE DESIGN DRAWINGS TO ACCURATELY REFLECT FIELD PERFORMANCE CONDITIONS. 18. THESE STRUCTURES SHALL NOT BE USED FOR COMBUSTIBLE OR HAZARDOUS MATERIAL. 20. OPTIONAL•EXTEPIOR WALL COVERINGS INCLUDE CORRUGATED ALUMINUM, MA5A ALUMINUM, 4- LAP ALUMINUM, 5/8' P'.T.'TI-I I SIDING, VINYL. SIDING WITH ENERGY BRACE BACKER, HARD] BOARD, STEEL SIDING AND'PLEKO' STUCCO ON 5/8' DENSE GLA55 GOLD AND POLYCARBONATE GREENHOUSE PANELS 21. ALL DOORS SHALL BE ABLE TO BE OPENED FROM THE EGRE55 SIDE W]THOUT THE USE OF A KEY. Hane- Associates, Inc. Engineering & C-mistructicin -Planning iZ P.O.Itox]4S, Stc Lf04 S.G 29692 - Ph...M-646.7600 409 Dixon Street Vidalia, GA 30474 Sheet Index S1.0 Cover - General & Design Notes S1_1 Electrical & General Floor Plan S1.2 Skids & Floor Framing Plan S1.3 Skid and Floor Framing Details S1.4 Roof Framing & Schedule S1:5 Typical Frame Section Details S1.6 1 End Wall Frame Options GENERAL NOTES CONTINUED: 22. DOOR SHALL BE 2 I/4' x I I / I G- ALUMINUM EXTRUDED FRAME WITH AN -ALUMINUM PANEL INSERT. ALUMINUM TRIM. DOOR ATTACHED TO VERTICAL 2x4. 23. OPTIONAL DOOR5 INCLUDE DOUBLE ALUMINUM DOORS, GARAGE DOORS, GO" x 72' ALUMINUM DOOR, 32' AND 4S' 51NGU! DOORS, AND PRE HUNG STEEL DOOR5. TYPE. SIZE, QUANTITY, AND LOCATION MAY VARY. 24. PREMANUFACTURED DOORS THAT MEET APPLICABLE CODES MAY BE USED INSTEAD OF DOORS, LISTED ABOVE 25. MAXIMUM WALL HEIGHT TO BE 8'-O' 2G. ALL BRAND. MATERIALS SPECIFIED MAY BE 5U55TMJTED FOR EQUIVALENT OR GREATER PRODUCT. 27. ALL 5UILDING5'(EXCEPTTH05E IN USE. AS AN ACCESSORY BUILDING FOR ONE OR TWO FAMILY DWELLING UNDER 400sq.ft.) MUST HAVE ATLEA5T (I) 32'k80" (MIN.) DOOR. 25. ROOF FRAMING AND WALL FRAMING TO BE 3V METAL STUDS SPACED AT A MAXIMUM OF 24° O.C. Were desianed in accordance 2014 FBC, 511 Edition 2011 NEC 2014 Florida Fire Prevention Code For Wind Speed 160 mph, Exposure C WIND VELOCITY: I GOrriph WIND IMPORTANCE FACTOR: 1.0 WIND EXPOSURE: C INT. PRESSURE COEFFICIENT.- 0.1 & ENCLOSURE CLASSIFICATION: ENCL05_ED COMPONENTS AND CLADDING: -ROOF LOAD (ZONE.# ] ): +21.4/-43.875F -ROOF LOAD (ZONE #2): +21.4/-G 1.7 P5F -ROOF.LOAO (20NE #3): +21 .41-97.4 P5F -WALL .LOAD (20NE AM: +45.5/-49.6 F5F -WALL LOAD (ZONE k5): +4G.3/-58.5 P5F -WALL LOAD (ZONE #405): +45.9/-54.2 F5F 7. FLOOR DE51GN wE LOAD: 125 F5F 81 FLOOR' DESIGN DEAD LOAD: 1'2 P5F 9. ROOF DESIGN LIVE LOAD: 20 P5F 10. ROOF DESIGN DEAD -LOAD: SELF WEIGHT 11. WALL DESIGN, LOAD: 8 F5F 12. COMBINATION LOA05; AS PER•A5CE 7-10 13. 5E15M(C U5E GROUP: B 14. BUILDINGCATEGORY: I 15. BUILDING OCCUPANCY: . STORAGE - NON HABITABLE 1 G. CONSTRUCTION TYPE: V B 17. ALLOWABLE FLOORS: F 18. EXTERIOR WALL FIRE RATING: 0 19. DESIGN OVERHANG: 8 INCH 20. DESIGN MEETS INTERNATIONAL BUILDING CODE 2005 & FLORIDA BUILDING CODE 21. THE CONTRACTOR/MANUFACTURER MUST COMPLY WITH THE FOLLOWING CODES: 2014 FBC, 51h Edition 2011 NEC 2014 Florida Fire Prevention Code THESE BUILDINGS ARE EXEMPT FROM THE THE FBG ENERGY CODE IN ACCORDANCE WITH 101-5.2 SITE INSTALLED ITEMS: I . THE'COMP.LETE'FOUNDATION 5UPPORT AND TIE -DOWN SYSTEM. 2. RAMPS, 5TAIR5 AND GENERAL ACCE55 TO THE BUILDING. 3. ELECTRICAL SERVICE HOOKUP (INCLUDING FEEDERS) -TO THE BUILDING. 4. ROOF DRAINAGE SHALL. COMPLY WITH F'B.C. 1503 AND R318.G NOTE: THI5 L15T DOES NOT-NECE55ARILY LIMIT THE ITEMS OF WORK AND MATERIALS THAT MAY BE REQUIRED FORA COMPLETE INSTALLATION, ALL SITE RELATED ITEMS ARE SUBJECT TO. LOCAL JURISDICTION APPROVAL Single Wide Metal Master Plan Lark Builders 409 Dixon Street Vidalia, GA 30474 By:' Project No. 12EN224 Checked By: Date: CJLA. 04/09/12 }ate g��� 0fnmttrtlo➢g PJ� .ToBulld6N CODE REVIEW(' Tl Professional Sewl4jo' usnies 1748 ]]rd Street Orlando, flodda 328$� A Plan Reviexer. Willia ary, 111 Icc # 5185M LA#000406 ° FL SMI-79, SMP51 Haney Associates, Inc. CertificateofAuthorization No. 27124 XGy, R. y�4��''. c 0�� yy�sd�SF 4;�" - UNALt s:1 v0 PSI APPROVAL 2015-05-24 ELECTRICAL NOTE51 1. WHEN. AIR CONDITIONING'IS.INSTALI%D IN THIS BUILDING;:IT 5HALL BE' THE RESPONSIBILITY OF: THE HVAC CONTRACTOR AND ELECTRICAL CONTRACTOR TO VERIFY wiRE AND BREAKE(L 51Zf5 FOR ACTUAL HVAC UNIT(5) INSTALLED ALL WIRING TO BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE LATE5T EDITION. 2. FLEXIBLE CONDUIT POP LIGHT FIXTURE5. 3. EACH CIRCUIT 15 TO HAVE CONTINU0U5 SOLID COPPER IN51.JLATED GROUND WIRE CONNECTED TO EQUIPMENT GROUND BAR IN THE MAIN D15TRIBUTION PANEL 4. EQUIPMENT GROUND BAR IN MAIN 1)15TRI13UTION PANEL 1510 BE GROUNDED TO MINIMUM I O•-0" COPPER CLAD'EARTH DRIVEN ROD WITH GROUNDING CLAMP APPROVED FOR DIRECT BURIAL. - 5. ALL CONDUIT TERMINATION5 OF I' OR LARGER ARE TO HAVE PLA5TIC IN5ULATED 51,15HING5. 6. ALL ELECTRICAL WORK I5 TO BE IN, ACCORDANCE MTN THE NATIONAL ELECTRICAL CODE (NEC), LIFE SAFETY CODE (NFPA 10I ), LATE5T EDITION5. 7. HVAC EQUIPMENT 5HALL BE PROVIDED WITH READILY ACCE551BLE D15CONNEcT5 ADJACENT TO THE EQUIPMENT 5ERVED. A UNIT 5WITCH WITH A MARKED'OFF° P05rrioN THAT 15 PART'OF THE HVAC EQUIPMENT 5HALL BE PERMITTED A5 THE D15CONNECTING MEANS ONLY WHERE OTHER D15CONNECTING MEAN5ARE AL50 PROVIDED. BY A READILY ACCE551BLE CIRCUIT BREAKER. 8. PRIOR TO ENERGIZINGTHE ELECTRICAL 5Y5TEM THE INTERRUPTING' RATING OF THE MAIN BREAKER M115T BE DE5IGNED AND VERIF(Eo A5 BEING IN COMPLIANCE WITH 5EC. 1 10-9 OF THE NEC BY A LOCAL ELECTRICAL CON5ULTANT, 9. THE MAIN ELECTRICAL PANEL, FEEDER5, POWER HOOKUP TO BUILDING (INCLUDING ALL D15CONNECT5, OVER CURRENT DEVICE5,;PANEL5; GROUNDING, ETC.) 15 DE5IGNED BY OTHER5, 51 TE IN5TALLED, 5UBJECr TO LOCAL JURI5DICTION APPROVAL. 10. -ALL WIRE5 TO 5WITCME5 AND OUTLET5 TO BE # 12 AWG THHN AND WILL MEET THE COLOR CODE REQUIREM61'f5 5ET FORTH IN THE NFPA 70, NATIONAL ELECTRICAL CODE. 11. ALL ELECTRICAL OUTLETS SHALL BE GFCI IN ACCORDANCE WITH ARTICLE 12I0:8(A)(2) NEC-08. Electrical Symbol Key • GFCI Duplex Receptacle 120V 16 Incandescent Light w/ (1)-60w Bulb ❑J Junction Box $ Switch " Wp Weatherproof $R Switch w/ Receptacle Outlet 120v 10 H na v A sociNes, 3E neeiiag"BuConstiiietion;P.lanaing P.0SIrMt1e. S.G+•Phosc86C:616-7660 WINDOW HEIGHT, LOCATION AND QUANTITY MAY VARY 24" AND ARE OPTIONAL. 5' MAX. LMAX. "I "I .—. ` P.T. 3/4' T4G FLOOR 5HEATHING. SEE VARIOU5 END WALL FRAMING \ 5ECTION5 FOR WALL iY AND WINDOW FRAMING. � GO' MAX. WIDTH EIGHT DOOR, MAY VARY. r 24' MAX. 5EE VARIOU5 END WALL FRAMING 5ECTIONS FOR WALL AND'DOOR FRAMING. } OPTIONAL ELECTRIC TO- ` WO /4 32" MIN., 60' MAX. WIDTH EACH UNIT FIELD \. BY"G'-V HEIGHT Dom CONNECTED FROM LOCATION MAY VARY. EXI5TING POWER SOURCE TO UNIT 5C -& MAXIMUM BUILDING LENGTH NOTES: • ALL ELECTRICAL EQUIPMENT 5HOWN 15 OPTIONAL AND LOCATIONS "MAY VARY. These plans were designed in accordance With 2014 FBC, 51h Edition 2011 NEC 2014 Florida Fire Prevention Code For Wind Speed 160 rrph, Exposure C Typical Floor Flan 5CALE: 1/4'= V-0' Single Wide Metal Master Plan Lark Builders 409'Dixon Street Vidalia, GA 30474 Designed By. — Project No. O.R:H. 12BN224 Checked By: Date: C.L.A. 04/09/12 pa-, Infornwlion l oBuildOn CODE REVIEW Professional service Industries 1749 33rd street Orlando, Florida 32839 Plan Reviewer. William E. Neay, III ICC 9 5185040 LA IAJO0406 FL SMI-79, SMP51 Haney Associates, Inc. Certificate of Aufhonzation SIA _ PSI APPROVAL 2015-05-24 SKID LAYOUT AND FLOOR FRAMING SCHEDULE 125 psf Live- Load (2Skid) 125 psf Live Load (3 Skid) Width Joist Size&Spacing I A I B Widthl 40ist'Siie&Spacing A I g 6'-.0" 2x4's @ 16" O.C., Max. 15" 42" 6'-0" 2x4's @ 16F O'.C.,.Max. 12" •24" 8'-O" 2x6's @ 46" O.C., Max. 18" 60" 8'-0" -2x6's.@ 16" O.C., Max. 16" 32" 10'-0" 2x6's @ 16" O.C., Max. 24" 72" 10'-0" 2x6's @ 16" O.C., Max. 20" 40" 11`70" 2x6's @ 16" O.C., Max. 24" 84" 11'-011 2x6's @' 16" O.C., Max. 22" 44" 11'-8" aft @ 16" O.C., Max. 28" 84" 11'-8" 2x6's @ 16" O.C., Max. 24", 46" i31-o"I 2x8's @ 16" O.C., Max. 36" 84" 13'-0" I 2x8'S @ 16"`O.C., Max. 26" '52" 13'-8" I. 2x8's @ 16" O.C., Max. 40" ( 84" 13'-8" j 2x8's,@ 16" O.C., Max 28" 56" NUIC7: FA5TENER5 WILL MEET THE MINIMUM REQUIREMENT5 FOR ALL STRUCTURAL COMPONENT5 A5 5ET'FORTH UNDER FBC 2304.9.1 AND TABLE 2304;9.1 UNLE55 OTHEFW15E 5PEC(FIED. •ALL5KID5 ARE P.T.-4x6 S.Y.P:.12 OR (2)-P.T: 2xG-5.Y.P. R2 • G'-O' WIDE UNIT5 MAY U5E 2.4 5.Y.P. N3 J015T5 • AI -I _-011,T1, ARF TC) PF P T.-5_Y. P_ X9 Q f0 . st, 5EE 5CHEOULE F.OR J015T SIZE h •A• I. •B• I. 'A" 5EE 5CHEDULE FOR J015T 51ZE X XII 50'-0" MAXIMUM BUILDING LENGTH 50'=0" MAXIMUM BUILDING LENGTH Typical 2 Skid Floor Framing Flan Typical 3 Skid Floor Framing Plan 5CALE: 1/4"= P-O" 5CALE: 1/4•=1'-O' �y�,ctr ildOn /rtfomudion .ToB6 CODE REVIEW Professional Service Industries I 174833rd Street Orlando, Florida 32839 Q Plan Reviewer. William E Neary, III 5 ICC # 185040 LA #000400 FL SMI-79, SMP-51 ; I In Haney Associates, Inc. STATE NAL 't' 1111W10- I These plans were designed in accordance wit h: i Sheet Number: 1 2014 FBC 5te Edition Single. Wide Metal Master Plan DeaignedBy. ]?roectNo. Haney Associates, Inc. 2011 NEC Lark. Builders . O.F-H. 12EN224 Engineering & Construction Planning 2014 Florida Fire Prevention Code i S1.2 P.O.o:3g@,sanmasc;sssr-l? oan86444s-•tcao f 409 Dixon Street Chcckedgy IJate: -For Wind Speed 160 mph, Exposure C Vidalia, GA30474 Cl-A. 04/09/12 3of7 PSI APPROVAL 201'5-05-24 Approval Stam s: %' — 20621a., mETAL WALL STUDS ,SEE PLAN VIEW POP SPACING i t 5ND5 MAY BE PS;-4xG 5 Y:P. SEE FRAMING'SCHEDULE #2 2x6 S.Y.P..N2- FOR J015T 51ZE ! 'P E 1 ' - 2Qga. METAL 50LE PLATE, i CONTINOU5 W/ 5116'h4" LAGS ATTACH EACH 5TUD`TO'SOLE ! ( AT 16° O.C., Max.PLATE w WITH (2j #1 O SELFr—P1 .T, 3/4" TEG FLOOR DRILLING GRABBERSCREW5 ! ! SHEATHING (1) INTO EACH FLANGE. + { ! j SENCO K26 (OR EQU drCH•5ri IYz°x IYr NAILS AT I", O C ROW5 FOR EACH FLOORJOIST 5HALLBE 1.5 PROM EDGE, STAGGER ROWS G" FOR (2)-P.T.-5.Y.P-2xG5'SKID5.. START PATTERN WITHIN-G' OF EACH END OF5tJD ! tl. t iti :72.BLOCKING BETWEEN SKIDS, FASTEN TO END-1 2x4 BLOCKING BETWEEN 5KLD5, FASTEN W/ NAI1-5 AT 12° O.G EACH I. (2)10. l20"x3' NAILS AT 51DE,,STAGGERED. 12' O-C., STAGGERED.. I 1 . SKID6FLOOR FRAMING DETAIL �� / `? \END JOIST FRAMING DETAIL scALe:Is=ro i rniation jai-ToBu1 O r w� e..e1a ^Id On j CODEREVIEW 1 SKIDS totAY BE P.T,. 4x6 S:Y:P, #2 OR (2)-P;T.-2x6 S.Y.P--. #2 ^ e Professional Service Industries 1749 33rd Street Orlando, florid. 32839 Plan Reviewer. William E. Neary, III I. Icc a 5185M I LA auooeoa - FL SMI-79, SMPSI as . - 2' LAPIS LICE FASTENED "� - W/ (6)-511 GN4• LAGS i (� a P T 4xG 5.Y-P. (OUTER FACE)- (3)-w i'04" ATTACH J015T TO 5KID WITH 5/ I G x4" LAG 5CREN OF (2) _ 5]MPSON H-3 (OR EQUAL) AT EACH EACH END OF JOIST; SEE FRAMING SCHEDULE FOR 5LZE: #2 5KID5_ LA65 (INNER FAGE), (9) LAG 5CREW5:TOTAL YJ 3:x6° SPLICE PLATE'.ON 3. of 4 SIDES OF JOINT, FASTEN Haney Associates; Inc. € t Certificate ofAHtttorization IL —27124 NOTE: ATTACH END JOISTS TO SKID WITi (2}511 G°z4° LAG SCREW5 [OR,(4)-0.,131 x4' GUN NAILS] AND A 5IMP56N H-3 [OR EQUAL] AT EACH END OF JO15T. S Y2P P 2 SKIDS. K28 (O EQUAu r)iA�lIESNCO EACH SfDE. - �.�`1GK ,.R I y ` Q� q Q. ��C Ng6 l "0. ,G�/"k No. 6Y558 TYPICAL SKID TO 3' . O15T CONNECTION DETAIL I , SG4LE: r 4 TYPICAL. SKID,SPLICI G DETAIL SCALE: 3+4`-1'-0' . STATE OF i "'i ZONAL i Haaiey AssoeiateS, Inc. Engineering &c Construction Planning P.O. Hor348,Slz Maq S-C.396n PCaae:86Abi61608 I These plans were designed I accordance wit h: 2014 FBC, 511 Edition 1 2011 NEC 1 2014 Florida Fire Prevention Code i , i For Wind Speed 160 mph, Exposure C Single Wide Metal Master Plan Designed By: Project No O.R.H.I2EN224 f S Checked By: , Daze: ( C.L.A. 04109/12 Sheet-Ntunber: '! S 1 .3 4 of 7 Lark Builders 409 Dixon Street I Vidalia, GA`30474 PSI APPROVAL 2015-05-24 ROOF FRAMING.SCHEDULE Wall Framing at 24" o.c., Max.. Width Rafter and Brace Size and Spacing: 6'-0" ASIS SSMA S 35OS162-43 @ 24." O.C.:Max. 8'-0" ASIS SSMA S 35OS162-43 @ 24" O.C. Max. 'IT-0" ASIS SSMA S 35OS162-43 @ 24a O.C. Max. 11'-0" ASIS SSMA S 350S162-43 ,@ 24" O:C; Max. 11'-6" ASIS SSMA_S 350S162-43 @ 24" O.C.'Max. 131-0" ASIS SSMA S 35OS162-43 @ 24" O.C. Max. 13'-6" ASIS SSMA_S 35OS162-43 @ 24" O.C..Max. SCHEDULE AND ROOF FRAMING NOTES: • ROOF FRAMING SHALL BE SPACED TO UNE UP DIRECTLY OVER THE WALL STUDS FOR PROPER LOAD TRANSFER AND STRAPPING. • ROOF DRAINAGE SHALL COMPLY WITH F.B.C. 2010 1503 AND•R3I6.6 • FASTENERS WILL MEET THE -MINIMUM REQUIREMENTS FOR ALL STRUCTURAL COMPONENTS A55ET FORTH UNDER FBC 2304.9.1 AND TABLE 2304.9.1 UNLE55 OTHERWI5E SPECIFIED. • RIDGE MAY RUN IN THE SHORT DIRECTION 'TURNAROUND' OR'VAULTED" 5TYIF WITH A MAXIMUM GABLE END OF'30-0' AND SIDE WALLS THAT VARY 970' TO' l N-V OR THE LONG DiRECTION,'5TANDARD' WITH GABLE ENDS THAT VARY G-0' TO 13,-& WITH A MAXIMUW51DE WALL LENGTH OF 50'-0°. • ATTACH ROOF FRAMING TO'TOP PLATE OF WALL FRAMING W1TH BUILDEX 10-I Gx l TEK5 PANHEAD 5CREW5 WITH #3 DRILL POINT AT 6`.O.C. 20ga. METAL RAFTERS BRACING,.5PACED AT D.C., MAX. LINE UP ER5 TO LAND ON WALL 75 FOR LOAD TRANSFER 50'-O" MAXIMUM BUILDING LENGTH - 30'-0° MAXt FOR VAULTED ROOF , Typical Roof Framinq Plan SCALE: 1/4'=,I'-O' CODE REVIEW Professional Service lndustries 1748 33rd Street Orlando, Florida 32839 Plan Revie .. William E. Neary, III Icc a 5185= LA RU994e6 FL SMI-79, SMP-51 i Haney Associates, Inc. Certificate of'Authorization_ No.27124 .�`GK R. �ly, c pQ�\ No. 64558 ' = fit= — - .- = i1121111=1 1 These plans were designed in accordance with: t I aneeL ivumoer: - Single Wide Metal. Master an Designed By: Projec[iVo. 1 2014 FBG 5-Edition O.R:H. 12EN224 Haney Associates, Inc. 2011 NEC { Lark Builders Engineering 8c Construction Planning, 12014 Florida Fire Prevention Code jj 409 Dixon Street. q; g Date; S I A P.O:Hoz3ra S�hIDgSG39682-Phone:5646Cb7600 a For Wind Speed 160 mph, Exposure C _ -- Cj. A: y 04/09112- Vidalia,.GA 30474 5 of 7 PSI APPROVAL 2015-05-24 2 1 /2' x 1 /2" CORRUGATED ROOF PANEL5 FA5TENED WITH A /4'-14 x ,3/4' H WN TRAXX/ I AT G" O.C. 61 i SEE ROOF FRAMING 5CHEDULE FOR RAFTER5 -5EE ROOF:FRAMING 5CHEDUL€ FOR FASTENING REQUIREMENTS 5EE 51 .2-FOR 5= AND FLOOR FRAMING x VARIES. G'-O' to Typical Frame Section SCALE:. 1 /4'- 1'-O' M'/z'-20ga.;METAL COLLAR TIE, 4'-0' LONG, ATTACH kV/ (2) #.1 O 5EIF DRILLING GRABBER SCREW5 EACH 51DE x-F.- ga. METAL 5TUD5 5PACED AT 24' O.C. MAX. 31z _20ga. METAL BRACE AT 3'-O" ABOVE FINI5HED FLOOR, ATTACH TO EACH STUD W/'(2) #10 5ELF DRILLING GRABBER 5CREW5, (1) INTO EACH FLANGE —2.1/2'x 1/2' CORRUGATED PANEL5 (FA5TENED WI #&-x -IY2 WOOD SCREW AT G' O.C. (OR EQUAL) These plans were designed in accordance with: Haney Associates, Inc: t 2011 NEC fill Edition Engineering & Construction Planning: ; 2014 Florida Fire Prevention Code y° P.O.Bo:348,,sinttl�,&C29692-Ph-864446.76e6 1} For Wind Speed 160 mph, Exposure C ATTACH R TOP FIAT[ 5EE ROOF FRAMING j 5CHEDULEFOR, RAFTER AND ! BRACING 51ZE5 AND 5PACING I � tt M,'-20,3a. METAL 5TUD5 � t it I I '50ACED AT 24' O.C. MAX. I OVERHANG OPTION DETAIL L. 5CALf:.3/4.- r-o. . .ATTACH RI TOP PLATE WITH BUIU PANHI AD DRILL POII, 5EE ROOF FRAMING 5GHEDULE-FOR RAF1 [R AND BRACING 51ZE5 A14D 5PACING - ' i I t i ii c� 5l�'-20,3a. METAL 5TUD5 ! SPACED AT 24' O.C. MAX. 2 OVERHANGOFTION•DETAIL 1 . 5CN.E: 3/4-1•-O' Single Wide Metal Master Plan Lark Builders 409 Dixon Street Vidalia, 'GA 30474 Approval Stamps: , )OF FRAMING TO OF WALL.FRAMING )EX 10-.16x1 TEK5 iCREWS WITH #3 T AT.G' O.C. Irfomlalion At )OF FRAMING TO.•ild OF WALL FRAMING CODE REVIEW )EX 1o.I Gzi TEr5 professional Service industries iCREVd5 WITH#3 f74833rd Street r ATG' O.C. Orlando, Florida 32839 Plan Revie c William E Neary, III ICC # 6186M LA #000406 FL SMI-79, SAP-51 'Haney Associates, Inc: Certificate of Authorization ' No.27124 - 11111 LInn1tt1.Ir�r STATE OF FS cCOR49P. •(j=• .`S�OIVAL 001 rrr+ll It,, Sheet.Nmben Designed By: Pmject No.. O.R-.H. 12EN224 S1.5 Cheaked,By: Dater C.L.A. D4/09/12 ` 6,47 PSI APPROVAL 2015-05-24 Approsz115tamps: 2-1/2" x 1 /2' CORRUGATED ROOF PANEL5..FA5TENEDWITH 1/4°-14x — 3/4, HWH TRAXX/1 AT G" O.C: j 11 34 20ga (J'ETAL BRACING, If ATTACH EACH END TO STUDS W/ 3� METAL BRACE AT 3'-0° (2) # 10.5ECF DRILLING GRABBER `: 3/z METAL BRACE AT 3'-0' ABOVE FIN151HED FLOOR, ; \ AL90VE FIN15hf FLOOR, ATTACH TO EACH STUD 5CeEW5, (1) INTO' EACH FLANGE" gT EACH TO EACH STUD W1.(2) # 10-5ELF DRI WNG t (NOTE THAT THIS BRACING IB I W/ (2j,# 10 5ELF DRILLING I GRABBER 5CREW5, (1) j REQUIRED ON SIDEWALL.5 AS WELL GRABBER 5CREW5, (] ) INTO EACH FLANGE ) (BOTH 51DE5 OF EACH CORNER)j INTO EACH FLANGE —551.2 FOR 5KID ANE`FLOOR ! VARIES 6-O to ! 3' 8" EE FRAMING VARIE5,'6 0 to' 13'-5" End Wall Framing Option End Wall Framing O,ptlon_ SCALE: 1/4"= P-O" WALL OPENING FOR=5IDE WALLS ARE SCALE: 1/4°=1'-O' i TO BE FRAMED,SINIILAR TO THOSE SYIOWN HERE FOR,ENDINACLS �j�■ Ir�mtatidn ToBuilrlOn 2-NELS FA5TENED WITH I/4"'-14 z 1 /2' x 112' CORRUGATED ROOF CODEREV/EW 3/4" HWH TRAwI AT 6" O.G.. 1 Pr.1essionalS.MC9Jndus&ies PA f. 1748 33rd Street { Orlando, Florida 32839 l f S Plan Reviewer. William E. Nary, III LCC88185940 IC fR 18M FLSMI79 SMPS1 I 6-0" Max. 3%z 20ga METAL BRACING, Max. 1 ATTACH EACH END TO STUDS W1 -VZ METAL BRACE AT 3'-O' i A (2) AI 0 5ELF DRILLING GRABBER I 3�2 METAL,BRACEFL R. ABOVE FINISHED FLOOR, L ABOVE FINISHED FLOOR, Haney;Associates, Inc. SCREWS, (1) INTO EACH FLANGE I ATTACH .TO.'EACH STUD Cemficate ofAuthodzation ATTACH TO EACH STUD b l No.11124 W/ (2) # I 0 5ELF DRILLNG [NOTE THAT THIS BRACING W I W/ (2) # 1 O SELF 5. (J NG GRABBERSCREW5, (1) REQUIRED ON SIDE WALL5A5 WELL GRABBER:SC(ZEWS, (J) j INTO EACH FLANGE (BOTH.SIDES OF EACH CORNERtplJlllt )] i INTO EACH FLANGE j `t rr t 140TETHATTI115.13RACING 1 r. ,' IS,REOUIREb ON SIDE 5EE 51.2 FOR 5YJD AND FLOOR f WALL5 A5 WELL (BOTH t * No. 64558 ; VARIES, G-O' to 13'-&" FRAMING EACH CORNED i VARIES, 6'-O° to 13'-8° 5IbE5 OF End Wall Framing Option End Wall Foaming Optionp� STATE OF l 5CALE: 1/4°= 1'-0" � �C.` I 'rrl7tittt�� I hese plans were designed in accordance Wit ti: i .l Sheet Number: 1 �2014 FBC, 5th Edition $�rlgle �/Ifi@ @fiad �aStei'�Iall i Deslgtiedroject24 Haney Associates, Inc. II l I O.R.H. 12EN224 $ ,. 2011 NEC l Lark Builders p„ 'Engineering 8c Constructiion Planning I 2014 Florida Fire.Ftevention Code 1 V 409 Dixon Street Cbecie&By: na e: eo:soxaa&SIX Mik,scz96ez-en—sul-6ebidoo ( For Wind Speed 160 mph, Exposure C 1 C.L.A: 04/09/12 II Vidalia, GA"30474 _ �. j 7-of7 ilE-DOWN NOTES: I. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. Z. ALL ME1SUREMENIS ARE CENTETL-TO-CENTER. !. RE -DOWN STRAPS TO BE 1-1• : 0.035' GALVANIZED STEEL. FEDERAL - SPECIFICATIONS OGS-781-H, TYPE-1. FINISH-B. GRADE-1. TIE -DOWN STRAPS AND CONNECTING HARDWARE TO HAVE 4.725 LB. MINIMUM ULTIMATE CAPACITY 4. ALL EARTH ANCHORS SHALL HAVE A MINIMUM 4,300 LB. CAPA7. 5. FMDi-ANCHORS LOCATED AT EACH CORNER. MAXIMUM 16- FROM END (4 MINIMUM PER BUILDING). AND SPACED AS PER TABLE 2A.B.0 DEPENDING ON SHED WIDTH. WIND SPEED, AND EXPOSURE. ANCHORS NOT NEEDED ON ENDS. 5. CONCRETE ANCHORS TO BE SPACED AS PER TABLE 1AB.0 DEPENDING ON SHED WIDTH. WIND SPEED. AND EXPOSURE 7. CONCRETE ANCHORS TO HAVE A MINIMUM Of 4' COVER (DISTANCE FROM ANCHOR TO EDGE OF CONCRETE). B. MINIMUM SOIL BEARING CAPACITY IS 2.000 PSF (TP.) B. EARTH ANCHORS AND CONCRETE ANCHORS MAY BE USED IN CONJUNCTION PROVIDED THAT THE SAME MAXIMUM SPACING IS FOLLOWED FOR EACH ANCHOR TYPE 1R-OOwN S1RAP (SEE NO1ES) TIE-OOA'N STRAP BOLTED TO TYPE 3 ANCHOR WITH 1/2' GRADE 5 BOLT MWIWU WTM wAEHERs 1/2•.3' I400 IB.J CONCRETE WEDGE ANCHOR WITH U—N. (TYPE 3) WE -DOWN ViPAP BOL' DE -DOWN STRAP BOLM THRU FLOOR JOIST WWTRRH1 1/2' GRADE 5 BOLT WA, WITH WASHERS RDOR JGST WITH 1/2' DOLT N UM WITH TIE-OOMI SIPAWPRX80.TE0 1/2'.J' (400 lll) CONCRETE WEDGE ANCHOR WRH WASHER 3 00LµT WMMDM TI .. wEocE EJIGHOR WITH u- A- OONCREIE 1/2•.3• (4aa lB.) CONCRETE WEDGE ANCHOR WYM 2' WASHER hN SOLE PUIE (W.TUPNLY WItABIE WDOD OR P.T.) �A -_--____� TE-DOWN STRAP (SEE NOTES) A,__—___ __ _ 1/213' (4W 18.) N COCRETE a' CONCRETE �E MICNOR WITH 2' WASHER (1) 4.4 SYP /2 ON 5' WK OR LESS (2) — OR (1) 4.6 P.T. SYP /2 51®5 ALL ELSE(CAI BE SEf ON GRWNO), CONCRflE Ifpp pp _pp TYPE 1 C�iL;Irf��j TYPE 2 y 30• DRIVE ANCHOR 30' AUGER ANCHOR FOR RDGE/CORAL FOR BOIL/CLAY pp pp TYPE " T3 LVNYPE ANCHOR WITH EXPANSION BOLT TYPICAL ANCHOR TYPES (1) h4 SYP /2 ON B' wIOE OR LESS OR (1) 4.6 P.T. SYP /2 MDS ALL t2SE(CW BE SEE ON GRONG). WE -DOWN STRAP SECURED WITH (B) 10W15• NA115 5/8' . 30' DVIIN All — AUGER S1YfE MR SO6/C1AY DRNE SME FOR ROCX/CODA 4' CONORET _ TE-DOWN STPAP BOLTm — FLDOR J06T 1/Y GUDE 5 (1) a.4 SYP /2 ON B' WIDE OR lESS BOLT W WRN wA9aR5 (2) 2.6 oR (1) 4.6 P.T. SYP /2 SKOS ALL F15E(CAN BE SEf ON GI10WD). 5/5' . 10• EARTH ANCHOR WITH, EYE HOLE: AUGER -LE MR SOIL/OAY. DRNE STYLL FOfl ROCK/Oa- CONCRETE (1) a.a SYP W e' IEtiS �-DOWN STRAPSTRAP10 (]) .B OR (1)/2 4.6 P.TWIDE. SYP /OR2 (SEE NOTES) - ALL EISE(CAN BE SET ON GROLINDJ. NO RE-50W'N SRUP BOLTED TO OR GROUND ANCHOR VRM 1/2' GRADE' IDE 5 BOLT MNIUUu W0H WASHERS >R: I 5/B• . 30• EARTH ANCHOR: I ILLER SIRE TOR SGL/C1AY, GnvE G1YfE roR Roa/DDRAL a' NNCRETE TABLE 2A — 165D/170C TABLE 2B — 14 30" AUGER ANCHOR SPACING 30" AUGER ANCHOR SPA SHED WIDTH , MAXIMUM ANCHOR SHED WIDTH MAXIMUM AN SPACING SPACINC P_ T T6'_-(`i'4` 10'-0• UP TO 16'-0" 1(Y-0' 6-1" TO 20'-0' 8'-0' 16'-1 • TO 24 -0 e'-O- 0'-1" TO 247-0 s —o TABLE 1 A — 12 TABLE 2C — 120C ANCHORING TO CONCRI 30" AUGER ANCHOR SPACING SHED WIDTH MAXIMUM AN( MAXIMUM ANCHOR SPACING SHED WIDTH SPACING 24'-0" 6'-0• UP TO 24'-0" 10'—o• 20'-0" 7—o• 16'-0" 7-6" 14'-0" 8'-0• 12'-0" (I) 4a4 SYP /2 ON B' WTOE OR LESS (2) 2a8 OR (1) 4.8 P.T. SYP /2 )_ EL4(WI BE SET ON GRGMD). 10'-0" 10'-6• 6'-0" MONA. SUPPORT PAD (P.T. w000, CONCPEfE BLOCX OR PAO) SPAEFD AT 8'-0• MAIL /r(1) a.a SYP /2 ON W WIDE OR LESS I (A. LLSE(CAOR NI BE a5E7 ON GROUND). CONCRETE 4.4 SYP /2 ON B' WIDE OR L ?.6 OR (1) 46 P.T. SYP /2 SXDS ELSE(CAN BE SET ON Gi0UN0). iFA PE ON TYPE C1XX1 Rua LsaN SYSEM 1X4a �G�l NUUBER OF STOW6 SPEED V+-120/,45/165/O e/D OEUO6T0 REMUnE mEFF1aaT1r ./- a FACTGL LOAD LOUD LON LO10 OF WAuS, BDDR ROOF N/A ER BURDING PROIFDIYJN USEDE SHELTER USAGE MO DTAGE 711 SRAT. OR I E IT I.. AGO''' Z� 2:= S� 0 O i � : STATE OF U Z , A- •. FIORIDI �i (� •'•'•... CG Matthew T. Baldwin P.E. Florida Dcansa 64608 g [Sha6L AP-1 OF 1