DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
GAF
I Campus Drive
Parsippany, NJ 07054
SCOPE:
MIAMI-I 11111- COUNTY
PRODUCT CONT :OL SECTION
11805 SW 26 : !.rent Room 208
Miami, Flc ida..:3175-2474
T (786) 315-25901 (780) 315-2599
AWN-miamida 'Wi Occonomv
This NOA is being issued under the applicable rules and regulations governing the use of construction mal rial S. The
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control ect:on to be
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product .on trol
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the igh t to
have this product or material tested for quality assurance purposes. If this product or material fails to pet brn t in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may irnm. dial ely
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the igh t to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this prc luct or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building C ide
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD*, Timberlines Natural Shadow`, Timberline' American Hari :ssf , and
FortitudeTM Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and 1 4la ving
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been: o c; Lange
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration, date or if there has been a revision or change .a tl e
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any rod uct;,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with f .iy , ecti.on
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and follo !red by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it sh ill t e done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distribute rs a nd
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA # 14-1022.20 and consists of pages 1 throu 6Co
The submitted documentation was reviewed by Alex Tigera.
MIAMbDADE COUNTY NOA No.: 6-0 411.,11
' ' Expiration Dat :: 01 /21� 22
APPRApproval Dat : 01 109i 17
'ag;e 1 of 6
ROOFING ASSEMBLY APPROVAL
Category:
Sub -Category:
Materials.• 4
Deck Tyne:
SCOPE
Roofing
Asphalt Shingles
Laminate
Wood
This approves GAF Timberline HD®, Timberline' Natural Shadow, Timberline American' Harvest '', a zd
FortitudeTM Shingles as manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product
GAF Timberline HD®
Manufacturing
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline Natural
Shadow'
Manufacturing
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline' American
Harvest®
Manufacturing
Locations #2, 4, 5, 6
GAF FortitudeTM
Manufacturing
Locations #1, 4
Dimensions Test Product Descrintioi
Specifications
13 '/4" x 39 3/8" TAS 110 Fiberglass reinforced heavy weigl t as Shalt
roof shingle, with a laminate prof le
13 1/4" x 39 3/8"
13 '14" x 39 3/s''
13 '/4" x 39 3/8"
MANUFACTURING LOCATION
1.
Tampa, FL
2.
Michigan City, IN
3.
Baltimore, MD
4.
Myerstown, PA
5.
Ennis, TX
6.
Tuscaloosa, AL
7.
Dallas, TX
TAS 11.0 Fiberglass reinforced heavy weigl as; )halt
roof shingle, with a laminate profi e
TAS 110 Fiberglass reinforced heavy weigh . asl shalt
roof shingle, with a laminate profi
TAS 110 Fiberglass reinforced heavy weigh as1 halt
roof shingle, with a laminate profi:.;
NOA No.: [641811.11
Expiration Da it: 0 1/21./22
Approval Da �D t/091/17
!'av 2 of 6
ENIDENcE SUBMITTED
Test ALvency
Test Identifier
Test Name/Report
Underwriters Laboratories,LLC
ASTM. D3462
4787344101
;Date
Underwriters Laboratories, Inc.
ASTM D3462
0 i /25,11.6
Underwriters Laboratories, Inc
ASTM D3462
I1CA48924
10124,/11
Underwriters Laboratories, Inc
ASTM D3462
lOCA21994
026/'1.1
Underwriters Laboratories, ,Inc.
ASTM D3462
1 OCA28717
05CA47541
07'2i 11
Underwriters Laboratories, Inc.
ASTM D3462
06CA31580
I Ul0106
11 30/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF-101-02-02
11, 02/05
Underwriters Laboratories, Inc.
ASTM D3462
06NK05159
08/ 09/06
PRI Asphalt Technologies, Inc.
Underwriters Laboratories, Inc.
ASTM D3462
GAF-098-02-02
1.1/ 08/05
Underwriters Laboratories, Inc.
ASTM D3462
ASTM D3462
02NK41809
08/ 11/02
Center for Applied Engineering
ASTM D3462
03NK26444
257989
10/ 17/03
Underwriters Laboratories, Inc.
TAS 107
OINK45803
05/ 13/97
04/13/94
Underwriters Laboratories, Inc.
TAS 107
06NK05159
08,/ )9/06
Underwriters Laboratories, Inc.
TAS 107
04NK04273
02./ >-0/04
Underwriters Laboratories, Inc.
TAS 107
05CA42840
11111105
Underwriters Laboratories, Inc.
TAS 107
02NK41811
11/ 11/02
Underwriters Laboratories, Inc.
TAS 107
03CA35209
10/ 17/03
Underwriters Laboratories, Inc.
TAS 107
04CA13850
08/30/04
Center for Applied. Engineering
TAS 100
257989
04/01/97
PRI Asphalt Technologies, Inc.
TAS 100
GAF-044-02-01
:)1/'.3/04
PRI Asphalt Technologies, Inc.
TAS 100
GAF-098-02-01
11./08/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-101-02-01
11,109/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-116-02-02
')3,/,.3/06
PRI Asphalt Technologies, Inc.
TAS-100
ELK-083-02-01
!.0/1 6/02
ELK-084-02-01
0/15/02
ELK-085-02-01
.01] 4/02
ELK-086-02-01
1.0/2 4/02
ELK-087-02-01
:. 0/2-1/02
ELK-088-02-01
0/16/02
ELK-107-02-01
OX 9/03
ELK-108-02-01
.0/0 9/03
ELK-109-02-01
0/0 9/0:3
,IMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials I: irec tort' for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Bu Air g Code
and Rule 61G20-3 of the Florida Administrative Code.
MIAMMADE COUNTY NOA No. 16- )81:1.11
Expiration Da .e: U 2/21122
Approval Da :e: U 2/09/17
Pag e 3 of 6
.7
INSTALLATION
I. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city uj�d state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Mi. uni••Dade
County Product Control Seal as shown below.
MIAMI•DADE COUNTY
...leyl
p
BUILDING PERMIT REQUIREMENTS
L Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to ' pro;perly
evaluate the installation of this system.
MIAMI•DADE COUNTY
NOA No.: i.6-d 811.11
Expiration Dai 01/21/22
Approval Dal 0;:/09./17
'ago - 4 of 6
DETAIL A
COURSE LAYOUT
a
ADE COUNTY
NOA No.: 1 -o;B 11.11
Expiration Date: 02/: il/22
Approval Date: 02A 19/17
P, ,ge ! of 6
.DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
�- 39-3/811
141/2 - 17-1/2"
(366 - g45mm)
6-1/2" - 9-1/2"
(165-2aFir-2 T/2—
tmm)
14-1/2"-17-1/2" —
�(366 - 445mm)
(tss _ 2aimm)
ENHANCED NAILING PATTERN - six nails per shingle*
" required by some focal codes and required for enhanced wind coverage on certain products.
See Limited warranty for details.
These shingles MUST be nailed a nominal 6" (152mm) from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
aMIAM=WryMADECOUNTy
Nail gu :le li ie
5-3/4" - 6 i/4"
(146mm j59rr m)
from bott( 'n of, hin&
zoea sez
adhesiv
on back
NOA No.: 16. 11811.11
Expiration Date: (P,/21 /22
Approval Date: b /Og 11 7
Pag--6Cf6