Loading...
HomeMy WebLinkAboutProject InformationProject Summary Date: Oct05,2017 . wrightsoft Entire House BY: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM For: GENTILE 3706 AVENUE M, FT. PIERCE,FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD 42 OF 70 OF 28 OF Heating Summary Structure 17142 Btuh Ducts 3856 Btuh Central vent (19 cfm) 582 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 21580 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) 1051 1051 Volume (ft3) 9459 9459 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 71 36 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.1 kW 17448 Btuh 50 OF 318 cfm 0.015 cfm/Btuh 0.50 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 14843 Btuh Ducts 6068 Btuh Central vent (19 cfm) 312 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipmenf sensible load 20162 Btuh Latent Cooling Equipment Load Sizing Structure 1515 Btuh Ducts 1633 Btuh Central vent (19 cfm) 790 Btuh Outside air Equipment latent load 3938 Btuh Equipment total load 24100 Btuh Req. total capacity at 0.70 SHR 2.4 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN; JANITROL; AMANA DISTI... Cond GSX160301 F Coil ASPT37C14A AHRI ref 8242117 Efficiency 13.0 EER, 16 SEER Sensible cooling 19600 Btuh Latent cooling 8400 Btuh Total cooling 28000 Btuh Actual air flow 933 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio � A 0 � Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� vtrrii ht50ft' 2017-Oct-05 10:43:e 1 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...ocuments\Wrightsoft HVACXGENTILE-3706 AVE M.rup Calc = MJ8 Front Door faces: E wrightsoft, Right-M Worksheet Job: Entire House Date: Oct Os, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House BED 2 2 Exposed wall 140.0 ft 22.0 It 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 11.0 x 11.0 ft 5 Room area 1051.0 ft' 121.0 ft' Ty Construction number U-value (Btuh/ft'-°F Or I HTM (Btuh/ft') I Area (ft') or perimeter (ft) I Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 - G -- --r- 13A-0ocs ' .1Ac1om' 1A clom ------ 0.143 1.270 1:270 - n - -n 'n —'- 4 OD' 35.56 35:56 2 55 3477 34 77 -- — 396 6 9 -- 366 0 ". 0 -- - 1465 213 320 - --,- 932 209 313 — 0 0-^ 0 0. 0 0 0 0 '. 0 0 0 0 11 JA-clom_._. 13A-4ocs 1.270 0.143 .n_. a . _ 35.56 4.00 „34.77. 2.55 _ . 15 234 _._0 173 __ __.533 693 . .: _ 522 440 .- _ _0 0 _ _ , .0 0 .; ,- .__0 0 .. 0: 0 1A-clom " 1Ac1am;, 1Ac1om -. 1A clom _ 13A-0ocs 1 A cl om _ 22A-tpl_ _ 1.270 0.390 0:143 1:270 1.270 ..4.270 0.143 1.270 - - 0.989 e _ _e-- s s s s_= w w_ '._ 35.56 10.92, 4.60 3556;. 35.56 -35.56. 4.00 35.56 1:37_ _._27.69- 91.12 11.31 "255 3477 34.77 _ 34.77 2.55 91,12 _2.57 _-,- 000 40 21 = "39fi 12 15 _ 20 234 24 __1051, _-- 1051 0 , 21 349 12 15 20 210 _ 0 ;...:. 1051 -- - --140 1422 ---•-- 229 1397 427 533 - .711 841 853 _ T_ :`1442 ----3877 3645 _ .__ 238 688 417 622 _ .... 696 535 _ 2187 ,: , _2709 _-- - _0 0 - 0 , 99 12 - 0 " , -. 0 99 _ - , - , 12 _ .._ .-._-121 ._--- 121 0 0 " 87 12 0. ._: _ _ ' 0 87 , 0 ', - - ..121' - - __-_-22 0 0 3'48 427 "'0 .. _ - 0 348 . - . 427 ,. , : _ _iss -_- 609 0 --- 0- 221' 417 0 , . ..0 221 - - - 1093 0 N13A-0ocs W L—G F 61 c) AED excursion 01 1 1 178 Envelope loss/gain 1 149591 14245 1 25 2443 12 a) Infiltration 2183 598 343 94 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 17142 14843 2668 2537 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 17142 0 0 14843 0 236 2905 0 139 2676 Duct loads 22% 41% 3856 6068 22% 41% 653 1094 I15 20318I 20911 I I 3554I 37701 l I Air requi d (� m) I I I 933 168 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .4C = ..! , _ Wri9htS®ft„ 2017-Oct-05 10:43:e I �`i� Right-Suite®Universal 2017 17.0.14 R SU 08101 Page 1 ocuments\Wrightsoft HVACIGENTILE3706 AVE M.rup Calc = MJ8 Front Door faces: E wrightsoft, Right-J@ Worksheet Job: Entire House Date: Oct 05, 2017 QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name BED 3 CLST 2 Exposed wall 23.0 ft 4.0 ft 3 Room height 9.0 It heat1cool 9.0 ft heat/cool 4 Room dimensions 11.0 x 12.0 ft 4.0 x 6.0 ft 5 Room area 132.0 ft' 24.0 ft' Ty Construction U-value Or HTM Area UP) Load Area ft' Load number (Bt u h/f?- Fj (Btuhlft� or perimeter (ft) (Btu h) or perimeter (ft) (Btu h) Heat Co.[ Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 V I �Aziocs: I 4� -.-n-- -4-.- '00 2.55 108 -99 396 0 '0 0 0 IA IA-clom 1:270 n 35.56 34.77 0 0 0 0 0 0 0 I A-cl om 1.270 - n 35. 56 .34.77 9 -0 -320 313 0 0 0 0 IA-clom, , I- ' 270 n., 35,56f .3�4.77, ._0 0 - 0 0 0 0• 0 6 11 Val 1 3AAocs 0.143 a 4.00 2.55 0 0 0 0 0 .0 0 0 ,A-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 11D0----- 13A j4qcs: I A -clom" 1A--clom - 0.390 -0,143 1.270 1.270 a-- s s s, 10.92 4 * 00 '3 666 - 35.5& 11,31 -2 55 `3� 77 3 0 b o 'D 0 0 6 .�o -0 0 - 0 0- 0 -0 :o 0 0 - 0 -0 0 -0 0 0 0 0 -0 0 1A-clom-- -A.270 s -35.56 34:77. 0 % -0 0 0 0 n -0 0 I 3AAocs 0.143 w 4.00 2.55 99 87 348 221 36 36 144 92 T-G. lA-cloTn- 1.270 w 35.56 91.12 12 0 427 109 0 0 0 0 c 16B-19ad,-. 0.049 1,-37 2.57 '132 132 ---181 340 24 24 i 33 , 62 F 22A-tpI 7 0.989 _7 27.69 0.00 132 23 637 7 0 24 -----.7 4 Ill 0 1 61 c) AED excursion 2651 1 1 10 10 Envelope loss/gain 1 23101 24841 1 1 2881 143 12 a) Infiltration 359 98 62 17 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2668 2583 350 161 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 322 220 -350 -161 14 Subtotal 2990 2803 0 0 15 Duct loads 221/6 41% 673 1146 221/6 41% 0 0 Total room load 36631 394 1 "1 1 Air required (cfm) 55 1791 6 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Oct-05 10:43:27 .Z= -pp- wright:50ft' Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 '44� ocumentsXWrightsoft HVACXGENTILE-3706 AVE M.rup Calc=MJ8 Front Door faces: E -► w ightsoft Right-J® Worksheet Job: .Entire House Date: Oct 05,2017 QUICK CALCS, INC. By. 317 ST. LUCIE LN., Ff. PIERCE, FL 34946 Phone:772-466-6799 Fax: 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDR 1 BATH 2 Exposed wall 10.0 ft 8.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/coot 4 Room dimensions 11.0 x 10.0 It 5.0 x 8.0 ft 5 Room area 110.0 ft2 40.0 ft2 Ty Construction U-value Or I HTM I Area (W) I Load Area (ft2) Load number (Btuh/ft2-°F (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross NIP/S Heat I Cool Gross NIP/S Heat Cool 6 13A-0ocs 1A-c1om 0 143 1.270 d n. 4 00 3556 2 55 3477, 0 D 0 0 0 0 0 0 72 D 72 0 _ 288 0 183: 0 1A-cldun :_ 1 A c1 om .. .._ .. 1.270 _ .. 1..270 n - n , 3556 ._ 35 56, 3477. 34 77 0 .. -0 -0 _ 0 0 _ _ ._ 0 0 . _ _ 0 0 _, _0 0, :_ 0, 0 .' _ _ 0 0 _.. _ 0 11 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 VL13A-4ocs 1A-clom 11DO 13A-flocs'; ;.. tAclom :' 1Aclom 1.270 0.390 "'0,143 1270 1,270 a _e_ -s s s, 35.66 10.92. 4.00' 3556 3556 91.12 11.31 255 3477 34.77 0 0 90 0 ' 0 0 0 - 70 0 0 0 _ 0 `'280 k: 0 0 0 _ 0 178 0 0 0 0 .: '. 0 0 0 0 _ _ 0 0,: 0 _ 0 0 _ _ 0 0 0 0 0 0_ `0. 0 " 0 1Ac1om. .1-.270 -.s,. _..35.56.: .34.77 _ 20 _. _ '20 711 :_.695 0.' 0'. _' . 0 0 W L_—G 13A-4ocs 1A-c1om, 0.143 1.270 w w_ 4.00 35.56 2.55 9112 0 0 0 0 0 0_ 0 0 0 _ 0 0 0 0 0 0 0 C, - 16B 19ad_. ,_ - 0:049 ... _ 1.37 l :.:.2.57 110 :.710 _151 _._._._ _283 ;_._. 40 :._ .. 40 55 103 F- 22A-tpl 77 - - 0.989 - 27.69 - 0-� - ,-110 - - 10 - - 277. — 0 .. ---- 40_____ - 8 222 .0 61 c) AED excursion 1 801 1 1 1 19 Envelope loss/gain 1 1419 1237 1 1 565 267 12 a) Infiltration 156 43 125 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliancesiother 0 0 0 0 0 0 Subtotal (lines 6 to 13) 1575 1280 689 302 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 22% 41% 0 0 122 1698 382 0 0 117 1396 ' 571 22°/ 41% 0 0 98 787 177 0 0 93 395 162 Total room load Air required (cfm) I I I 20801 31 19671 88 I I 965I 15 557] 25 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 27 z. -pp-Wrlghttsa'ft' 2017-Oct-0510:43:e 3 Right-Suite®Universa12017 17.0.14 RSU08101 Page ocuments\Wrightsoft HVAC\GENTI LE3706 AVE M. rup Calc = MJ8 Front Door faces: E -�} wrightsoft, Right-J® Worksheet Job: Entire House Date: Oct 05, 2017 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: QUICKCALCS(!40L.COM 1 Room name KITCHEN HALL 2 Exposed wall 34.0 ft 5.0 ft 3 Room height 9.0 ft heaUcool 9.0 ft heat/cool 4 Room dimensions 1.0 x 190.0 ft 1.0 x 194.0 ft 5 Room area 190.0 ft2 194.0 ft' Ty Construction U-value Or HTM Area UP) Load Area (ft') Load number (Btuh/ft'-'F (Btuh/ftq or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool j Gross N/P/S j Heat I Cool j Gross N/P/S j Heat Cool 6 13A-00cs. 1A clom -, 0.143 1:270 n n 4.00. 35.56: 2 55 3477 189 6 168 0 673 213 428 209 . 0 0 0 0 -. 0 ' 0 0 0, 1 A cl om 1270 n, 35.56 34 77 0 0 0 t) 0 0, 0 0 1A clom _. _ _ -1.27.0 : n _ 35.56; 34.7.7 .. ,. - 15 - 0 - - _ 533 522 _ .: ,' 0 - _ - _ 0 - . D . 0 Vil 11 13A-4ocs 0.143 a 4.00 2.55 90 70 280 178 45 24 96 61 IA-clom 1.270 a 35.56 91.12 20 0 711 1822 0 0 0 0 L-pC 1100- __ 13A-4ocs - 1A clom 1A clom 0.390 0.143 1:270 •1.270 __ e _ s s . s 10.92 -.4,00 35.56' 35.56 11.31 2.55 34.77 34.77- 0 27 '0 0 0 27 0 0 0 - 108 0 0 0 - 69 0 0 _ _ _ _ _21 0 0 0 21 0 -0 0 229 0 - 0 0 238 0 0 0 1A clom - - _ 1.270 s._' . 35.56:... 34.77 .,.- 0 0 ,.. -" 0 0 _.. .. 0. 0 _0 0 VII 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 G 1A-clom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 G .. - l6B:19ad--,. _ _: _ -. ' _ 0.049. ..._ 1.37: ,2.57: .._... _ 196.1 _ .. 190 ,261 .. , , 489 . _ -194 . 19-4, _ .266 A99. F _ 22A-tpI_ - _---- - -- _ _r 0.989 27.69 0.00 ,r190 _ -: -34 --_-- 942 _ __ ---- 194 ^ 5 - _,-- 138 0 61 c) AED excursion 1 1 -225 -48 Envelope loss/gain 1 3721 3491 1 1 730 750 12 a) Infiltration 530 145 78 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 4251 3636 808 771 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 199 212 -808 -771 14 Subtotal 4450 3848 0 0 15 Duct loads 22% 41% 1001 1573 221% 41% 0 0 loaded(cfm) I 51 5482I 542 I I ��aeQUom ! I I 242I OI OI Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �" WPightSOft' 2017-Oct-0S 10:43: �A Right -Su 17.0.14 RSU08101 Page 4 ocumentslWrightsoft HVAC\GENTILE-3706 AVE M.rup Calc = MJ8 Front Door faces: E - wrightsoft" Right-M Worksheet Job: Entire House Date: Oct 05, 2017 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name A/C LIVING 2 Exposed wall 0 ft 34.0 ft 3 Room height 9.0 ft heat/coot 9.0 ft heat/cool 4 Room dimensions 5.0 x 4.0 ft 11.0 x 20.0 ft 5 Room area 20.0 ft2 220.0 ft' Ty Construction U-value Or HTM I Area (ft') I Load I Area (ft') Load number (Btuh/ft'-'F (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 wj(r�� C 13A-flocs 4Ac1om--- 1Ac1om -1A c1 'm . ...... , 13A4ocs 0.743 1:270 1.270 1,270 0.143 n. n n ._. n __ a 4 00 3556 3556: - 35 56 4.00 2 55 3477 3477 .. 34 7Z 2.55 0 0 0 0 0 0 0 0 ._ .._ .. 0 0 0 0 0 _ ._ _ 0 0 0 0 0 .- .. . _ _0 0 27 0 0- 0 99 27 0 0 .._5._ 0 79 108 0 0 .._ .....:0 316 69 D 0 0 201 1A-clom 1.270 a 35.56 91.12 0 0 0 0 20 0 711 1822 11D0_ _ 13A-4ocs. ," 0.390 0A43 a 10.92 4.00 11.31 -2.55 _0 0 . _ 0 0 _ 0 0 0 0 _-_- 0 ' 180 - _ 0 165 ___ _ 0 661 0 420 1Ac1om 1.270 ,s- s 6 35.5 34.77 0 0 0 0 0 T5: .0 15 0 533 0 522 1A-clom 1.270 ,"s.- 35.56` 34.77.. 0. _0 _ 0 0 Vy 13A-0ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 L—G C .. .. _IA-clom_ -- - _766;19$tl- . _.. -- - 1 270 -0.049 ._ w - ,=_. - - 35.56 . ,. e 1.3Z -91.12 .. `..2.57 - •- ., _ . , 20 - 0 _ : _ 20 -- -- 0 „ _ .: ,' ._ 27 _0 , .. - .' 51 — r -- 0 _ _ '220 -- 0 ::...-_ MO - 0 __ . _: 302 - 0 ._.,_ . _ 566- F _ __ _ -22A tpl _ _ .0_989 T 27.69 0.00 _ 20 0 { _ 0 _ _ _ 0 _ _ 220 34 942 _0 61 c) AED excursion 1 -3 -219 Envelope losstgain 1 271 481 1 1 3573 3381 12 a) Infiltration 0 0 530 145 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 27 48 4103 3526 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -27 -48 208 199 14 Subtotal 0 0 4311 3725 15 Duct loads 22% 41% 0 0 22% 41% 970 1523 Total room load 0 0 I 5281 I 5248 Air required (cfm) I I I 0 OI 80I 234I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WYIg{t7tsofE' 2017-Oct-0510:43:27 Right -Su itee Universal 17.0.14 RSU08101 Page ..ocuments\Wrightsoft HVAC\GENTILE-3706 AVE M.rup Calc = MJ8 Front Doorfaces: E Duct System Summary Job: s wrightsoft° Date: Oct 05, 2017 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: QUICKCALCS ,AOL.COM For: GENTILE 3706 AVENUE M, FT. PIERCE,FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.376 in/100ft 318 cfm 133 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.376 in/100ft 933 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 557 15 25 0.496 4.0 Ox 0 VIFx 5.8 95.0 BED 2 c 3770 54 168 0.377 7.0 Ox 0 VIFx 17.5 115.0 st1 BED c 3949 55 176 0.378 7.0 Ox0 VIFx 17.4 115.0 st1 BEDR 1 c 1967 31 88 0.376 7.0 Ox 0 VIFx 18.1 115.0 st1 KITCHEN -A c 5421 82 242 0.395 8.0 Ox 0 VIFx 11.7 115.0 st2 LIVING -A c 5248 80 234 0.390 8.0 Ox 0 VIFx 13.0 115.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 162 476 0.390 873 10.0 0 x 0 VinlFlx st1 Peak AVF 141 432 0.376 792 10.0 0 x 0 VinlFlx 2017-Oct-05 10:43:28 R wirightSOft' Right -Suite® Universal 2017 17.0.14 RSU08101 Page i +� ...ocumentslWrightsoft HVACIGENTILE-3706 AVE M.rup Calc = MJ8 Front Door faces: E Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox 0 80 234 0 0 0 0 Ox 0 VIFx rb5 Ox 0 82 242 0 0 0 0 Ox 0 VIFx rb4 Ox 0 15 25 0 0 0 0 Ox 0 VIFx rb1 Ox 0 85 256 0 0 0 0 Ox 0 VIFx rb2 Ox 0 55 176 0 0 0 0 Ox 0 VIFx �� *wright5(3ft° Right -Suite® Universal 2017 17.0.14 RSU08101 /MN ...ccuments\Wrightsoft HVAC\GENTILE3706 AVE M.rup Calc = MJ8 Front Doorfaces: E 2017-Oct-05 10:43:28 Page 2 4,ob #:'- Pirfonned'idr -tOENTiLE', 3706 AVENUE M FT. PI,ERCE,FL QUICK CALLS,_ INC. 317 ST LUCIE LN. r . F PIERCE, r , FL 34946 Phone:, 172-466-099 Fa)'c-772-466-6796 QUICKcALCS@AOL.QqM Scal.w. 1 :63 Page 1 Right-Sultet Universal 2017 ,174.14. RS-UO61-01 2017-Od-05 10:3239 ...soft WAMGENTILE-3706 AVE