Loading...
HomeMy WebLinkAboutProduct Approval MullionsFL # FL21648-R3 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers, FL 33912 (800)432-2204 Ext4305 easengineering@easternmetal.com Authorized Signature James Flesher easengineering@easternmetal,com Technical Representative Jim Flesher Address/Phone/Email 10030 Bavaria Rpad Fort Myers, FL 33913 (800) 432-2204 jflesher@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications, Inc, Validated By Keystone Certifications, Inc. Referenced Standard and Year (of Standard) Standard Year AAMA 450 2010 TAS201 1994 TAS202 1994 TAS203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted Date Validated 10/24/2020 02/23/2021 Date Pending FBC Approval Date Approved 02/28/2021 Summary of Products FL # Model, Number or Name Description 21648.1 176 HVHZ X-Mullion 176 HVHZ X-Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL21648 R3 C CAC 622-109 QRO-l.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/06/2023 Design Pressure: N/A Installation Instructions Other: See drawing charts for mullion size, configuration and FL21648 R3 II 08-02951A.pdf design pressure Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL21648 R3 AE 513791A.odf Created by Independent Third Party: Yes 21648.2 176 HVHZ T-Muilion 176 HVHZ T-Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL21648 R3 C CAC 622-108 QRO.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/06/2023 Design Pressure: N/A Installation Instructions Other: See drawing charts for mullion size, configuration and FL21648 R3 II 08-02950A.Ddf design pressure Verified By: Luis R. Lomas, RE, 62514 Created by Independent Third Party: Yes Evaluation Reports FL21648 R3 AE 513790A.pdf Created by Independent Third Party: Yes 21648.3 176 HVHZ Vertical/Horizontal Mullion 176 HVHZ Vertical/Horizontal Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL21648 R3 C CAC 622-107 QRO.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/06/2023 Design Pressure: N/A Installation Instructions Other: See drawing charts for mullion size, configuration and FL21648 R3 II 08-02952A.pdf design pressure Verified By: Luis R, Lomas, RE, 62514 Created by Independent Third Party: Yes Evaluation Reports FL21648 R3 AE 513792A.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S„ please click here Product Approval Accepts: M go of Credit Card Safe C6RTIFICpT10N5, INC ZZ . Document Title: Structural Performance (� V ertification Authorization Report Doc No: FIRM B1-02 Rev No: Page: 1 Of: 1 Required By: PRO B1.03 CAR &Product ID Number Issue Date: Revision Date: Expiration Date: Company Code: 622 - 107.0 12/29/2016 5/27/2020 2023 622 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components . This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. Licensee Information: Eastern Architectural Systems 16341 Domestic Ave Fort Myers, FL 33912 USA Product Information: Model: 176 HVHZ Vertical/Horizontal Mullion Operator Type: Mull Config: No Reinforcement Max Width Max Height: See Table See Table Referenced Standard: Product Rating: AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test Report JNNCTL-210-4032-1 Test Report Expirat6/6/2023 Authorized Signature: Keystone Certifications, Inc. 2020.05.27 145 Limekiln Rd. Suite 100B New Cumberland, Pennsylvania 17070 16#641:48-04'00' Phone: 717-932-8500 Fax: 717-932-8501 W W W.KEYSTONECERTS.COM CEYSToN, Appendix 1 CAR No: 622.107.0 �e��' !� �^�. ■ ■ Expiration Date: 06/06/2023 Eastern Architectural Systems 10030 Bavaria Road Fort Myers, FL 33913 Load Tables for the: 176 HVHZ Vertical/Horizontal Mullion DESIGN PRESSURE RATING (psf) (Design pressures are positive and negative) Mullion Tributary width (in) span (in) 24.00 30.00 36.00 42.00 48.00 54.00 60.00 66.00 72.00 36.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 42.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 48.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 54.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 " 60.00 150.0 150.0 150.0 137.7 128.1 122.7 120.9 120.9 120.9 66.00 150.0 143.1 123.3 110.0 101.1 95.3 92.0 90.9 90.9 72.00 145.4 118.9 101.8 90.2 82.2 76.6 72.9 70.7 70.0 78.00 123.2 100.4 85.6 75.4 68.2 63.1 59.4 57.0 55.5 84.00 105.7 85.9 73.0 64.1 57.7 53.0 49.6 47.1 45.4 90.00 91.8 74.4 63.1 55.2 49.5 45.2 42.1 39.7 38.0 96.00 80.4 65.1 55.1 48.1 42.9 39.1 36.2 34.0 32.3 102.00 71.1 57.5 48.5 42.2 37.7 34.2 31.5 29.5 27.9 108.00 63.3 51.1 43.1 37.4 33.3 30.2 27.7 25.8 24.3 114.00 54.2 43.8 36.9 32.1 28.6 25.9 23.9 22.2 21.0 120.00 46.4 37.4 31.5 27.4 1 24.3 22.0 20.2 18.8 17.7 Impact Ratings PA/TAS 201/203 - Large and Small Missile Impact Rated Up to Wind Zone 4 and HVHZ Keystone Certifications, Inc. 145 Limekiln Rd, Suite 100E New Cumberland, PA 17070 Phone; 717.932.8500 www.keystonecerts.com NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ, 2, WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE, FRAMING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3, ALLOWABLE STRESS INCREASE OF 6/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN, WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS, 4. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS, 5, DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULLION, WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL 6, SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. WINDOWS ATTACHED TO MULLION MUST HAVE SEPARATE APPROVAL, 7. DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW OR DOOR UNIT. B. UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 9, MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT, SHEET N0. 1 I NOTES TABLE OF CONTENTS DESCRIPTION 2 APPROVED CONFIGURATIONS AND CHART — 5 INSTALLATION DETAILS REVISIONS REV DESCRIPTION DATE APPROVED A REVISED CUP 08/20/19 R.L ANCHORING NOTES: 1. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS, 2. FOR ANCHORING INTO CONCRETE USE 3/16" TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/4" MINIMUM EMBEDMENT WITH 2 1/2" MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS. 3. FOR ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS, 4. FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL LOCATE SCREWS IN ACCORDANCE WITH WINDOW ANCHORING SCHEDULE AS SHOWN IN WINDOW SEPARATE APPROVAL, 5. ALL FASTENERS TO BE CORROSION RESISTANT, 6. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI, C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER). D. METAL STRUCTURE: STEEL 18GA, 33KS1 OR ALUMINUM 6063—T5 .058" THICK MINIMUM 7. TO ATTACH MULLION TO CLIP USE (4) #10 x 1 1/4" SELF DRILLING SCREWS PER CLIP. SCREWS MUST BE FIELD INSTALLED. =�� Eastern ���N ��NRSAULPPL51YlEMS w mFOuMYFR5OOMESTIA 1 RT . FL 1w,T 176 HVHZ VERTICAL/HORIZONTAL MULLION LARGE AND SMALL MISSILE IMPACT NOTES V.L. scALE NTS DATE 09/15/16 REV OS-02952 A SHEEi1 QF 6 L ROBERTO LOADS P. 7432 WOODFORD RO LEW/SVlLLE, NO 27023 4346B8-0609 AlomasC�lAomaspe.com SIGNED: OB/20/20 i9 C OV`/ v •��C+ENS�•q��;o VIVO �7 VIVO TAf(TE OF Luis R. Lomas P.E. FL No.: 62514 145 1/4" COMBINED WIDTH W1-jr--W2 10�/�/ WINDOW FRAME WINDOIA WINDO14 HEIGHT (MULLION SPAN) W1--�1-W2- 145 1/4" L::-COMBINED WIDTH 145 1/4" COMBINED WIDTH W1-j�W2 FRAME HEIGHT WINDOW WINDOW (MULLION SPAN) //� 145 1/4" COMBINED WIDTH W1 W2 WINDOW WINDOW WINDOW 145 1/4" COMBINED WIDTH W1---j - W2 /WINDOW l WINDOW / d� Design pressure rafing (pso positive and negative Mullion Tributary width (in) span (in) 24.00 30.00 36.00 42.00 48.00 154.00 60.00 66.00 72.00 36.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 4200 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 48.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 54.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 60.00 150.0 150.0 150.0 137.7 128.1 122.7 120.9 120.9 120.9 66.00 150.0 143.1 123.3 110.0 101.1 95.3 92.0 90.9 90.9 72.00 145.4 118.9 101.8 90.2 82.2 76.6 72.9 70.7 70.0 78.00 123.2 100.4 85.6 75.4 68.2 63.1 59.4 57.0 55.5 84.00 105.7 85.9 73.0 64.1 57.7 53.0 49.6 47.1 45.4 90.00 91.8 74.4 63.1 55.2 49.5 45.2 42.1 39.7 38.0 96.00 8057 65.1 55.1 48.1 42.9 39.1 36.2 34.0 32.3 102.00 71.1 57.5 48.5 42.2 37.7 34.2 31.5 29.5 27.9 108.00 63.3 51.1 43.1 37.4 33.3 30.2 27.7 25.8 24.3 114.00 542 43.8 36.9 32.1 28.6 25.9 23.9 22.2 21.0 120.00 46.4 37.4 31.5 27.4 24.3 22.0 20.2 1 18.8 17.7 W1-II-W2 145 1/4" COMBINED WIDTH 145 1/4" COMBINED WIDTH W1- II rW2 // p// WINDOW < 1'NDOW 145 1/4" COMBINED WIDTH W1 r-W2 WINDOW WINDOW g WINDOW APPROVED CONFIGURATIONS W1I-W2- 145 1/4" COMBINED WIDTH REVISIONS I REV I DESCRIPDON I DATE I APPROVED A I REVISED CUP 108/20/19 ( R.L. DESIGN PRESSURE TABLE INSTRUCTIONS: 1. DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2. DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3. LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLON RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH = W1 + W2 2 rEASTERNARCHRECRIRALSYS 1 Eastern EASTERN--AIsup- a iBJ41 DOMe ICAVZ FOU WERS, F-912 •...-rev w•n..a�a awn onaw. B00.492 ^�Y04 y 176 HVHZ VERTICAL/HORIZONTAL MULLION LARGE AND SMALL MISSILE IMPACT APPROVED CONFIGURATIONS AND CHART DRAWN: Dwc No. V.L. 08-02952 SCALE NTS °^TE 09/15/16 1SHEEf2 OF 6 L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC27023 434-688-0609 rllcmasL&Momaspe.com SIGNED: 0812012019 0\ 1R I I IL/Or�/ �;•'��GENSt�`q�'�: 0,,61251 5`0 T((,ATT�E OF ; REV :�•'cZO zmt-- A MONAl.1E�G`�� Luis R. Lomas P FL No.: 62514 :i3•l A (REVISED CLIP MULLION CLIP Q MULLION CLIP / WOOD SCREW REVISIONS DESCRIPitON MULLION DATE APPROVED OB/20/19 R.L ANGLE #10 WOOD SCREW WOOD FRAMING 1 3/6 WOOD FRAMING 1 3/8" OR 2X BUCK MIN OR 2X BUCK MIN BY OTHERS EMBEDMENT BY OTHERS EMBEDMENT VERTICAL MULLION WITH CLIP DETAIL VERTICAL MULLION WITH ANGLE DETAIL 1/2" MIN, WOOD FRAMING OR 2X BUCK INSTALLATION 1/2" MIN, 1/2" MIN. WOOD FRAMING OR 2X BUCK INSTALLATION 1/293 MIN. EDGE DISTANCE SILL SHOWN -HEAD SIMILAR EDGE DISTANCE EDGE DISTANCE SILL SHOWN -HEAD SIMILAR EDGE DISTANCE SIGNED: 0812012019 EASTERN ARCRRECRIRAL SYS,EMS \\IIII11 Eastern EASRNryOF TEAL SUPPLY \\\S R. [Q��//,/ 1Bb1 DOMESiiCAVE `N J� E ��-^� .•.a+vi.wnuww ...,, nuuw.. 9OWW432 5•FL YTB,3 %4 \v NO ,V' / eeee� 176 HVHZ VERTICAL/HORIZONTAL MULLION azr _ *• 0 51 LARGE AND SMALL MISSILE IMPACT �00 5 �` INSTALLATION DETAILS -'�1 • TAT OF eoeso DRAWN: DWG No. REV 'cFs'ciaRlaP SCALE NTS DATE 09/15/16 08 So�T32 OF 6 A //��%/�0NAL,SN\`� L ROBERTO LOMAS AE' LUIS R. Lomas 1432 WOODFORD RD LEWISVILLE, NO 27023 FL No.: as P.E.P 434-688-0609 lllomasOltiomasoe.com METAL STRUCTURE BY OTHERS CLIP \, • 0 `"I 14 0 0 MS OR )RILLING METAL STRUCTURE BY OTHERS REVISIONS REV DESCRIPTION DATE APPROVED A REVISED CLIP 03/20/19 R.L v1S OR )RILLING VERTIMETAL STRUCTTURINSTALLATION l DETAIL METAL STRUCTURE I INSTALLATION ETAIL 3/4" MIN. SILL SHOWN -HEAD SIMILAR 3/4" MIN. 3/4" MIN. SILL SHOWN -HEAD SIMILAR 3/4" MIN. EDGE DISTANCE EDGE DISTANCE EDGE DISTANCE EDGE DISTANCE SIGNED: 0812012019 EASTERN ARDIMONRAI SYSTEMS �ry Eastern EAS ERNME A SUPPLY \� R I IL p, 18 i DOME =AVE \\ _\� ' . •ry� �j FDRT MYERS,FLM912 V aowuun ` v,.��OENSF'(p y 176 HVHZ VERTICAL/HORIZONTAL MULLION _ *4TATt 0 51 LARGE AND SMALL MISSILE IMPACT INSTALLATION DETAILS �1oOF DRAWN: owD No. REV %�'cFs'c�pjt>OP Gee\�� SCALE NTS DATR 09/15/16 OS 50�42 OF 6 A //;is/ONAI,006 E�\\`� L ROBERTO LOMAS P.E L415 R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomas@lrlomaspe.com FL NO.: 62514 CLIP • loll SIN MULLION CLIP CONCRETE /MASONRY STRUCTURE BY OTHERS � a Q' VERTICAL MULLION WITH CLIP DETAIL CONCRETE/MASONRYINSTALLATION 2 1/2 pr MIN. SILL SHOWN - HEAD SIMILAR EDGE DISTANCE ANGLE 3/1 6" TAPCON CONCRETE /MASONRY STRUCTURE BY OTHERS 1 1/4 MIN ° " ' EMBEDMENT ° 2 1/2" MIN EDGE DISTANCE 2 1/2" MIN, EDGE DISTANCE REVISIONS REV DESCRIPTION DATE APPROVED A REVISED CLIP 08/20/19 R.L MULLION MULLION ANGLE - a a a a VERTICAL MULLION WITH ANGLE DETAIL CONCRETE/MASONRYZNSTALLATION SILL SHOWN -HEAD SIMILAR ElSTERN ARCHIiECNRHLSYSTEM3 �� Eastern EASTERN METAL surc�v .4 18 U WMES, I =1 F-0RT MYERS. FL 99912 �ur�e� weannMs �..n Hones ���� 176 HVHZ VERTICAL/HORIZONTAL MULLION LARGE AND SMALL MISSILE IMPACT INSTALLATION DETAILS DRAWN: DWG NO. REV V.L. 08-02952 A scA E NTS DATE 09/15/16 SHEET55 OF 6 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE NO 27023 434-688-0609 AlomasCa (rinmasDe.cam 3/16" TAPCON .. 1 1/4 pp MIN EMBEDMENT I. a 2 1/2" MIN EDGE DISTANCE SIGNED: OS/20/2019 1R I IC�O��i,,, v••N y *' 0,,61251 •• yt TAffTE OFmass N • �- ss�0NA�1O�G`�� Luis R. Lomas P.E. FL No.: 62514 n�u �r �aN i ewau REVISIONS INO.: PART NUMBER I DESCRIPTION I MANUFAcruRERI MATERIAL REV DEscPiPTIV DSTE APPROVED 1 56372 WCUP SAPA ALUMINUM6063-T6 a I REw-Ec CLIP 08j 20/i9 1 RL, 3 156371 X 3"TUBE MULLION 5/16" i 1/4'X3"TUBE MULLION ALUMINUM 6063-7`6.125" THICK EFFECTIVE MOMENT OF INERTIA: 3,050 IN"4 EFFECTIVE SECTION MODULUS: 1.008INA3 tG 7ji6` [(P[i�F�3ij ANGLE ALUMINUM 6063-T6.125"THICK CLIP ALUMINUM 6063-T6.125"THICK j}1G X 1" PH ELE DPILLIN S'�'REW Lr�ATE ANCHORS PER NINDOVV/DC)Or ANCHOR SCHEDULE WINDOW EP.AhAE REFEPENCE ONLY AdULLIOW SELP DRILLING SCREW LOCATE ANCHORS PER WIMI)OW/DOOF.ANCHOR SCHEDULE WINDOW TO MULLION INSTALLATION DETAIL WINDOW FRAME SHOWN FOR DETAIL PURPOSES ONLY MULLION IS NOT LIMITED TO THIS PRODUCT EnStEAt! AItCMm26NRA4 5Y5TpM9 �� Eastern ��5�a, A i0KMYR 5M=1 Fbk/MYEPS. FLYJBI2 eA .....u" .w,wnnr" awn nun.. BNWY1-}2W �176 HVHZ VERTICAL/HORIZONTAL MULLION LARGE AND SMALL MISSILE IMPACT COMPONENTS DRAwn: cwc w0. V.L. 08-02952 ' E NTS DATE 09/15/16 jHEET 6 OF 6 L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC27023 434-688-0609 rJ1bmasplr1cmaspa.mm WIhIDCti^/ FRAME REFERENCE ONLY INTERIOR EXTERIOR S/GNED: 08/20/20i9 RI IL 0�'/// �,•��GENS�9s0r o,.6¢5 T(ATrOF � REv �i�F`•��ORIOP•�'�'��� A Luis R. Lomas P.E. FL No.: 62514 L. Roberto Lomas P.E. 1432 Woodford Road Lewisville, NC 27023 434-68&0609 Rllomas@lrlomaspe, com Manufacturer: Eastern Architectural System 16341 Domestic Ave. Fort Myers, FL 33912 Engineering Evaluation Report Product Line: 176 HVHZ Vertical/Horizontal Mullion, Large and Small Missile Impact Report NO.: 513792A Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20w3.005 method 1(a). The product listed herein complies with requirements of the Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-02952 Revision A prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Test report No.: NCTL 2104032-01 signed and sealed by Gerard J. Ferrara, P.E. National Certified Testing Laboratories, York, PA TAS 201-94 Large Missile Impact Test, Level D, Wind Zone 4, Mullion impacted with #2 SYP 2x4, 96 1/2" long, 91bs at 50 ft/sec. TAS 202 -94 Uniform Static Air Pressure, ±48.Opsf design pressure, 16.5psf water penetration. TAS 203-94 Cyclic Pressure loading ±48.Opsf design pressure 3. Mullion analysis with Anchor calculations, report number 513792-1, per AAMA 450-10 option 1, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: Refer to charts in approval document • Maximum mullion height: 120" • Maximum single fenestration width: 72" • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions. • Mullion material to be extruded Aluminum 6063J6. • Clip material to be extruded Aluminum 6063-T6. • Fenestration units attached to mullion must have their own separate approval. • Vertical units may be mulled indefinitely as long as maximum unit size is not exceeded. • Design pressure of mulled units shall be controlled by the lesser design pressure of the assembly components; the mullion or the individual units. lnstallafion: Units must be installed in accordance with manufacturer's installation instructions and approval document, 08-02952, Revision A. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the products) for which this report is being issued, Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed \\ product(s). \\� S R . *L . \\\J\••CEN•'�q��i ' 0�51 • �k o TAT 4F •w; O.c+•. •+ i���t•�, :cZ 0 R\�t �� \� ONAL`����� Luis R. Lomas, P.E. FL No.: 62514 08/20/2019