HomeMy WebLinkAboutProduct Approval Windows Single HungBCIS Home I Log In User Registration I Hot Topics ( submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search
bProduct
Approval
USER: Public User
Product Approval Menu > Product or Aooifeation Search > Application list > Application Detail
FL #
FL16412-R6
Application Type
Revision
Code Version
2020
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Eastern Architectural Systems
Address/Phone/Email 16341 Domestic Ave.
Ft, Myers, FL 33912
(800)432-2204 Ext4305
easengineering@easternmetal.com
Authorized Signature James Flesher
easengineering@easternmetal.com
Technical Representative Jim Flesher
Address/Phone/Email 10030 Bavaria Rpad
Fort Myers, FL 33913
(800)432-2204
jflesher@easternmetal.com
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
Referenced Standard and Year (of Standard) Standard Year
AAMA/WDMA/CSA 101/I,S.2/A440 2008
ASTM E 1886 2012
ASTM E 1996 2012
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL16412 R6 Eauiv FL16412 ASTM EQ,pdf
Product Approval Method Method 1 Option A
Date Submitted 02/25/2021
Date Validated 02/26/2021
Date Pending FBC Approval
Date Approved 03/02/2021
Summary of Products
FL #
Model, Number or Name
Description
16412.1
176 Vinyl Impact Single Hung
176 Vinyl Impact Single Hung
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL16412 R6 C CAC NI012195-Rl.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2024
Design Pressure: N/A
Installation Instructions
Other: Design Pressures are as follows: Fin Window
FL16412 R6 II 08-02538B .pdf
+70.0/-85.Opsf, Flange Window+70.0/-85.Opsf. Maximum Size:
Verified By: Louis R. Lomas, P.E. 62514
54" x 77". Frame Material to be Rigid PVC From Deceuninck
Created by Independent Third Party: Yes
North America AAMA Certified (DEP-1). GLASS INTERLAYER
Evaluation Reports
COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA
FL16412 R6 AE 513311C.pdf
BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY
Created by Independent Third Party: Yes
INTERLAYERS
16412.2
Series 176 SH Oriel PVB
Series 176 SH Oriel PVB Vinyl single Hung Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL16412 R6 C CAC NI015128 pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
11/30/2024
Design Pressure: +60/-60
Installation Instructions
Other: Frame Material to be Rigid PVC From Deceuninck North
FL16412 R6 II 08-03660.pdf
America AAMA Certified (DEP-1). GLASS INTERLAYER
Verified By: Luis Roberto Lomas 62514
COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA
Created by Independent Third Party: Yes
BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY
Evaluation Reports
INTERLAYERS
FL16412 R6 AE 514776.pdf
Created by Independent Third Party: Yes
16412.3
Series 176 SH PVB
Series 176 SH PVB Vinyl single Hung Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL16412 R6 C CAC NI015128.O1.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
11/30/2024
Design Pressure: +60/-60
Installation Instructions
Other: Frame Material to be Rigid PVC From Deceuninck North
FL16412 R6 II 08-03662.pdf
America AAMA Certified (DEP-1). GLASS INTERLAYER
Verified By: Luis Roberto Lomas 62514
COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA
Created by Independent Third Party: Yes
BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY
Evaluation Reports
INTERLAYERS
FL16412 R6 AE 514778.pdf
Created by Independent Third Party: Yes
116412.4 1 Series HD 2451/2461 1 Series HD 2451/2461 Vinyl single Hung Window Non -Impact
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL16412 R6 C CAC NIO11536.Ol.pdf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 11/30/2024
Design Pressure: +65/-65 Installation Instructions
Other: FL16412 R6 II 08-03686.pdf
Verified By: Luis Roberto Lomas 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL16412 R6 AE 514811.pdf
Created by Independent Third Party: Yes
16412.5 Series HD2451/Series HD2461 Single Series HD2451/Series HD2461 Vinyl Impact Single Hung
Hung
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +65.O/-65.0
Other: Maximum Size: 44" x 84", Nailing Fin or Flange Frame.
Frame Material to be Rigid PVC From Deceuninck North America
AAMA Certified (DEP-1)
Certification Agency Certificate
FL16412 R6 C CAC NI011536-R2.pdf
Quality Assurance Contract Expiration Date
09/30/2024
Installation Instructions
FL16412 R6 II 08-01933A.pdf
Verified By: Luis R. Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL16412 R6 AE 512641B,pdf
Created by Independent Third Party: Yes
tsack f L
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mall address released (n response to a public -records request, do not send electronic
all to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(i),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, FS, must provide the Department with an email address if they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click here .
Product Approval Accepts:
F Mr
Credit Card
Safe
NOTICE OF PRODUCT CERTIFICATION
CERTIFICATION NO:
DATE:
CERTIFICATION PROGRAM:
CODE:
REVISION DATE:
NI012195-R1
11/20/2014
Structural
Eastern
17834
04/29/2018
To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS
PRODUCT DESCRIPTION
Eastern Architectural Systems
Series '1176.043"
16341 Domestic Avenue
Vinyl Single Hung Window
Ft. Myers, FL 33912
w/Fin or Flange Frame
Configuration: O/X
Glazing: IG-Ext-3/16" Annealed Glass/Laminate4/8"
Annealed Glass/0.090" SGP Interlayer by
DUPont/1/8"Annealed Glass
Frame: W4372mm(54") H4956mm(77")
Panel: W4334mm(50.37") H-940mm(37.75")
SPECIFICATION
PRODUCT RATING
AAMA 506-08
Design Pressure: ±3351 Pa (70 pst)
AAMA/WDMA/CSA 101/I.S.2/A44041
Class LC-PG701372 x 1956 (54 x 77)-H
AAMA/WDMA/CSA 101/LS.2/A440-08
H-LC70 1372 x 1956 (54 x 77)
AAMA/WDMA/CSA 101/LS.2/A440-05
Positive Design Pressure: 3351 Pa (70 pst)
ASTM E1886-05/E1996-09
Negative Design Pressure: 4069 Pa (85 ps f)
TAS 201/202/203-94
Wind Zone 4-Missile Level D
Large Missile Impact Rated
Water Penetration Resistance Test Pressure: 502 Pa(10.50 pst)
Product Tested By;
Report No:
Expiration Date:
Certified Testing Laboratories, Inc.
CTLA-3 005 WA/CTLA-3 005 WD
June 30, 2024
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD,
3, 1 X BUCK OVER MASONRY/CONCRETE IS OPTIONAL,
4, WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS, ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL.
5, WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS,
6, WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
THE ARCHITECT OR ENGINEER OF RECORD.
7, BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED,
8, FOR FIN INSTALLATION SHIM AS NEEDED, FOR FRAME INSTALLATION SHIM AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR
GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS,
10, WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL: EXTRUDED RIGID PVC.
12, UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 2 FOR GLASS DETAILS,
13. APPROVED IMPACT PROTECTIVE SYSTEM i_S NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOR FIN INSTALLATION INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE, LOCATE
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
TABLE OF CONTENTS
SHEET N0. DESCRIPTION
1 I NOTES
2 — 3 ELEVATIONS
4 — 7 I INSTALLATION DETAILS
REVISIONS
ftEV ( 06CRIPTION ( DATE
8 REVISED GLAZING DETAILS D1/DB/16
15. FOR FRAME ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE, LOCATE
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS,
16. FOR FRAME ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT
LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2" MINIMUM
EDGE DISTANCE, LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
17. FOR FRAME ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR
WALL, LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS,
18. ALL FASTENERS TO BE CORROSION RESISTANT,
19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI,
C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER).
D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 .048" THICK MINIMUM
20. UNITS MAY BE INSTALLED WITH OR WITHOUT FLANGE, OUTSIDE THE HVHZ.
® EASTERN AR o RECRIPPL SYSTEMS
-��- Eastern � M��nPP�Y
.•. tONO RAVMy ROAD
,.....ram w...nn... �..n freer.. FOflT MYERS, FtARIDA SSStJ
800.iSt-"JBl
SERIES 176 SH VINYL SINGLE HUNG WINDOW
Month
IMPACT 54" X 77"Motto
NOTES
DRAWN: DWG N0.
N.G.
scALE NTS DATE 11/17/14
OS-02538 B
sREEr 1 OF 7
L. ROBERTO LOAAS P.E.
1432 WODDFORD RD LEWiSVILLE, NC 27023
434-688.0609 A/omasiB lAamaspe.crom
APPROVED
R.L.
SIGNED: 0 i/18/2018
�••� rJEN`Q6`q�'���
T(�A(T;rE dF ;
��
ONAL1E���`\
Luis R. Lomas P.E.
FL No.: 62514
54 FRAME WIDTH
6" MAX 14 6" MAX
MAX O.C.
13"
MAX O.C.
I �-
77"
FRAME
HEIGHT
6" MAX
ill4
y
SERIES i76 SH VINYL SINGLE HUNG WINDOW
EXTERIOR VIEW
FIN INSTALLATION
DESIGN PRESSURE RATING
IMPACT RATING
+70.01-85.OPSF
LARGE
MISSILE IMPACT
MISSILE LEVEL D, WIND ZONE 4 AND HVHZ
54"X 77' UNIT SHOWN. OTHER SIZES APPROVED AS LONG AS
FRAME AREA DOES NOT EXCEED 28.87 FT
m
B I REVISED GLAZING DETAILS
NOTES:
1.
MAXIMUM SASH SIZE: 50 3/8" X
37 3/4",
2.
MAXIMUM D.LO.:
49 1/8" X 34
3/4".
3.
(2) WEEPS
WITH COVER (97-03)
AT SILL FACE 2" FROM EACH CORNER.
4.
(2) 1 1/2"
X 1/4" WEEP SLOT
AT SILL FACE 2" FROM EACH CORNER_
5.
(2) 1/2" X
1/8" WEEP SLOT AT
SILL BEHIND GLAZING LEG,
1"
1 /8" ANN.
.090" SENTRY GLAS BY KURARAY
3/16" ANN, 1/8" ANN.
INTERIOR
EXTERIOR DURASEAL
SPACER STEM
QUANEX BY
GLAZING BEAD I I ili STRUCTURAL SEALANT
SIKAFLEX 552
SETTING BLOCK (30096)
1/2" BTE 85 DUROMETER
�I III BY CENTRAL RUBBER
EXTRUSIONS
GLAZING DETAIL
WHEN USED OUTSIDE THE HVHZ
3/16" TEMP
EXTERIOR
GLAZING BEAD
1 /2" BITE
REVISIONS
OATS APPROVED
01/OB/1BI R.L
1"
ANN.
090" SENTRY GLAS BY KURARAY
1/8" ANN.
INTERIOR
DURASEAL
SPACER SYSTEM
BY QUANEX
GLAZING DETAIL
WHEN USED /N THE HVHZ
STRUCTURAL SEALANT
SIKAFLEX 552
SETTING BLOCK (30095)
85 DUROMETER
BY CENTRAL RUBBER
EXTRUSIONS
� EASTERN MdIREONRAI SYSTEMS
�� Eastern �° MEroANL�1'PRIY
w tro�a eAVARw ROAD
.. ...... .rr..n+ w...nnwft ...n nanw" FORTMYERS,F RIOAM913
SERIES 176 SH VINYL SINGLE HUNG WINDOW
IMPACT 54" X 77"
ELEVATION
DRAWN: DWG N0,
N.G. 08-02538
'GALE NTS DATE 1 I/17/14 s EEr2 OF 7
L ROBERTO LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
434-688-0609 rilomas@lAomaspe.com
SIGNED: Oi/i8/20i8
r-
lAqTAn'��TiJr'O
REv 'PF•;czzo
IORIOP•
e �Fei��NALiE�G`N
Ss
Luis R. Lomas P.E.
FL No.: 62514
54" FRAME WIDTH
6" MAX 14 6" MAX
MAX O.C.
6" MAX
1_
loll
MAX
O.C.
77"
FRAME
HEIGHT
j
6" MAX
SERIES 176 SH VINYL SINGLE HUNG WINDOW
EXTERIOR VIEW
THROUGH FRAME INSTALLATION
FOR MASONRYAND METAL STRUCTURE
54" FRAME WIDTH
6" MAX 12" MAX O.C. {-- 6" MAX
6" MAX
8"
MAX O.C.
77"
FRAME
HEIGHT
i
5" MAX
SERIES 176 SH VINYL SINGLE HUNG WINDOW
EXTERIOR VIEW
THROUGH FRAME INSTALLATION
FOR WOOD FRAMING
DESIGN PRESSURE RATING
IMPACT RATING
+70.01-85.OPSF
LARGE
MISSILE IMPACT
MISSILE LEVEL D, WIND ZONE 4 AND HVHZ
54" X 77" UNIT SHOWN. OTHER SIZES APPROVED AS LONG AS
FRAME AREA DOES NOT EXCEED 28.87 FT`
REVISIONS
REV I DESCRIPTION DATE I APPROVED
B I REVISED GLAZING DETAILS Ol/08/18 I R.L
EnSTENNAA M SIOIRAL5Y5tEMS
'at� Eastern°�Nn
ioow envnRURoao
ORT MYERS, FLORIOn�JBt�
SERIES 176 SH VINYL SINGLE HUNG WINDOW
IMPACT 54" X 77"
ELEVATIONS
DRAWN: DWG NO. REV
N.G. 03-02538 B
scALE NTS JDATE 11/17/14 1SHEET OF 7
L ROBERTO LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, NO 27023
434-688-0609 Momas@lrlomaspe.com
SIGNED: 0111812018
v •��GENS,. tp %
TAT E OF
0R1OP
/MAL O1E�\�`�
Luis R. Lomas P.E.
FL No.: 62514
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
FYTFRlnR
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
1/2" MIN.
EDGE DISTANCE
1 1/4" MIN.
EMBEDMENT
1 /4't MAX.
SHIM SPACE
#10 WOOD SCREW
INTERIOR
ILL TO BE SET
!ABED OF
PPROVED SEALANT
1 /4" MAX.
SHIM SPACE
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
REVISIONS
REV
D6CRIPTION
DATE
APPROVED
B
REVISED GLAZING DEAILS
1 01/08/18
1 R.L
1 1/4° MIN. 1/4" MAX.
EMBEDMENT r SHIM SPACE
INTERIOR
1/2"
N. �0�
EDGE D�
DISTANCE II
#10 WOOD
SCREW
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER ROD EXTERIOR
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
��- � Eastern EASiFRN� o �,o o s
EASTERN METAL SYPPLY
W FORT AVAS,A RO
FORT MYERS, FIARIOASIBt3
80��"
SERIES 176 SH VINYL SINGLE HUNG WINDOW
IMPACT 54" X 77"
INSTALLATION DETAILS
DRAWN: DWG NO. REV
N.G. 08-02538 B
scALE NTS DATE 11/17/14 SHEET4 OF 7
L ROBERTO LOMAS PE
1432 WOODFORD RD LEWISVILLE, NC 27023
434.688-0609 ,ilomas[dl�lomaspe.com
SIGNED: Oi/i8/20i8Re
Luis
R.
Lomas
P.E.
FL
No.:
62514
METAL
STRUCTURE
BY OTHERS
APPROVED
SEALANT
rY-rr=alna
BACKER ROD
& APPROVED
SEALANT
M ETF
STRUCTUF
BY OTHEF
VERTICAL CROSS SECTION
METAL STRUCTUREWSTALLATfON
MIN
FnrF nnTANC.F
MAX.
SHIM SPACE
iMS OR
DRILLING
V
INTERIOR
TO BE SET
� BED OF
ROVED SEALANT
SHIM SPACE
3/4"
IN.
EDGE
DISTANCE
#10 SMS OR
SELF DRILLING
SCREWS
METAL
STRUCTURE
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
REVISIONS
REV
D6CRIP710N
DATE
APPROVER
B
REVISED GLAZING DETAILS
1 01/08/18
1 R.L
SHIM SPACE
INTERIOR
D7=C'
IyVrlNr.7-i
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
� EASTERNAR OHRECNRAL SYSTEMS
�� Eastern E�TER� �Er�nPPLY
P.
toms MVARK ROAD
FDRTWERS,FLORM10913
SERIES 176 SH VINYL SINGLE HUNG WINDOW
IMPACT 54" X 77"
INSTALLATION DETAILS
N.G. 08-02538 B
scALE NTS DATE 11/17/14 sHEFr5 OF 7
L R09ERT0 LOMAS P.E
1432 WOODFORD RD LEWISVILLE, NO 27023
434-688-0609 rllDmas@ITlomaspe.com
SIGNED: O1/18/2018
L1O���,''
= * 0,,61961 •• A =
O; ST((�ATT�rrE OF
04obd OQ: • �iL��
ONA1.,E�G`�\
Luis R. Lomas P.E.
FL No.: 62514
L R09ERT0 LOMAS P.E
1432 WOODFORD RD LEWISVILLE, NO 27023
434-688-0609 rllDmas@ITlomaspe.com
SIGNED: O1/18/2018
L1O���,''
= * 0,,61961 •• A =
O; ST((�ATT�rrE OF
04obd OQ: • �iL��
ONA1.,E�G`�\
Luis R. Lomas P.E.
FL No.: 62514
J 2" MIN.
EDGE DISTANCE
OPTIONAL 1X BUCK
SEE NOTES 3 - 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
EXTERIOR
•
OPTIONAL 1 X BUCK
SEENOTE3-7
SHEET 1
CONCRETE/MASONRY
BY OTHERS
SHIM SPACE
3/16" TAPCON
INTERIOR
REVISIONS
1 1/4" MIN. 1 1/4" MIN.
EMBEDMENT EMBEDMENT
CONCRETE/MASONRY
BY OTHERS w
OPTIONAL 1X BUCK v
SEE NOTES 3 — 7 0
SHEET 1
3/16" TAPCONN.
e..o.
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
1/4 yr
MAX.
SHIM SPACE
< G
Q•" n. .
a d
a-...
� CONCRETE/MASONRY
VERTICAL CROSS SECTION BY OTHERS
CONCRETE/MASONRYZNSTALLATION
2.. Q
MIN.
EDGE a >
DISTANCE
BACKER ROD
& APPROVED
SEALANT
SHIM SPACE
REV ' DESORIPTION
B REVISED GLAZING DETAILS
INTERIOR
D7=�C
EXTERIOR
JAMB INSTALLATION DETAIL
CONCRETE/MASONRY INSTALLATION
NOTES:
1. INTER/ORAND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
��-
Eastern
EwSTERNwRCNRECl11RAL SYSTEMS
EASTEFN ETRLS'PP�Y
.4 L
10o]00wVnRiw ROnO
FORT MYERS, FLORIOw]]St]
80W]Z-Y2M
SERIES 176 SH VINYL SINGLE
HUNG WINDOW
IMPACT 54"
X 77"
INSTALLATION
DETAILS
DRAWN:
DWG NO,
REV
N.G.
08-02538
B
scALE NTS
DATE 11/17/14
SHM6 OF 7
L. ROBERTO LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
434-688-0609 AlomasCdlAomaspe.com
DAiE APPROVED
Ot/OS/18 R.L.
SIGNED: O1/18/20Y8
/��:
qAT
goes0474*741
ORVO go
o e s Get'\\
Luis R. Lomas P.E.
FL No.: 62514
APPROVED
SEALANT
BEHIND FIN
#10 WOOD
SCREW
EDGE DISTR
1/2" MIN
EDGE DISTANCE
#10 WOOD
SCREW
APPROVED
SEALANT
BEHIND FIN
� � /Am 1AIAI
IAlTCOI/10
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
WOOD
FRAMING
BY OTHERS
1/4 to MAX.
SHIM SPACE
WOOD FRAMING
BY OTHERS
IN,
EMBEDMENT
#10 WOOD
SCREW
APPROVED
SEALANT
BEHIND FIN
1/4" MAX
SHIM SPACE
EDGE DISTANCE
REVISIONS
REV
OESCRIPDON
DATE
APPROVED
8
REVISED GLAZING DETAILS
01/OB/18
ft.L
EXTERIOR
JAMB INSTALLATION DETAIL
WOOD FRAMING OR ZX BUCKlNSTALLAT/ON
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
1 /4" MAX 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
SHIM SPACE DESIGNED IN ACCORDANCE WITHASTM E2112
SIGNED: Ol/18/2018
EASTERNAADIV41NOFL SYSTEMS
•`� Eastern 100308AVgRy.gOND�A�PPLY \`\\�\��.I C10����,'I
WOOD ..�mr w,,.un... �..x n.+nm.. FORTMYERS,FLORIDA3301S v 'aGEN3Fgs
W 800. 2-=4
FRAMING w wuM «o ,� • ,�'
BY OTHERS SERIES 176 SH VINYL SINGLE HUNG WINDOW *• 0 51
IMPACT 54" X 77
TAI TAT OF
=,o � .`
INSTALLATION DETAILS "� ,
DRAWN: DWG NO. REV fOR10 0!
SCALE NTS DATE 11/17/14 08 SoEET7g OF 7 B j`/jONA1.1a\\��
L ROBERTO LOMAS RE LUIS R. Lomas P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
434-688-0609 rllomasLaIrlomaspe.com FL No.: 62514
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville, NC 27023
434-688 0609
rllomas@lrlomaspe.com
Manufacturer: Eastern Architectural Systems
16341 Domestic Ave.
FT Myers, FL 33912
Product Line: Series 176 SH Vinyl Single Hung Window
Engineering Evaluation Report
Report NO.: 513311 C
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(a). The product listed
herein complies with requirements of the Florida Building Code,
Supporting Technical Documentation:
1. Approval document: drawing number 08-02538 Revision B, prepared, signed and sealed by Luis Roberto Lomas
P.E.
2. Test report No.: CTLA 3005WA signed and sealed by Ramesh Patel P.E.
Certified Testing Laboratories, Orlando, FL
AAMA/WDMA/CSA 101/I.S.2/A440
Design pressure: +70.0/-85.Opsf
Water penetration resistance 10.5psf
ASTM E1886/ E1996 Large Missile Impact, Level D, Wind Zone 4
Cyclic Load Test, +70.0/-85.Opsf design pressure
3, Test report No.: CTLA 3005WD signed and sealed by Ramesh Patel P.E.
Certified Testing Laboratories, Orlando, FL
TAS 202
Design pressure: +70.0/-85.Opsf
Water penetration resistance 10.5psf
TAS 201/TAS203 Large Missile Impact, Level D, Wind Zone 4
Cyclic Load Test, +70.0/-85.Opsf design pressure
4. Anchor calculations, report number 513311-1A, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: +70.0/-85.Opsf
• Maximum unit size: 54"
• Units must be glazed per ASTM El300 according to glazing details in approval drawing.
• This product is rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind borne debris regions.
• Frame material to be extruded vinyl.
Installation:
Units must be installed in accordance with manufacturer's installation instructions and approval document 08--02538
Revision B.
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
products) for which this report is being issued. Also, I on have nor will acquire a
financial interest in any other entity involved in the approval process of the listed
product(s). \\�
v • •y�C E N s�•gcr �%
* - 0 • �t
TAT OF ; w
\\
/;Ij ONAL,E����
Luis R. Lomas, P.E.
FL No.: 62514
10/22/2020