Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
-�- wrightsoft® Project Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM For: McFARLANE CARPORT ENCLOSURE 7507 SEBASTIAN ROAD, FT. PIERCE,FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 3494 Btuh Ducts 890 Btuh Central vent (51 cfm) 1557 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 5942 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Area ft Heat22g Cool22g VolumeZ(ft3) 1760 176000 Air changes/hour 0.61 0.32 Equiv. AVF (cfm) 18 9 Heating Equipment Summary Make SENVILLE Trade Model SENA-09HF-OZ AHRI ref 8797149 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF Backup: 11.2 HSPF 9400 BFtuh @ 47°F 320 cfm 0.073 cfm/Btuh 0 in H2O Input = 2 kW, Output = 6526 Btuh, 100 AFUE Job: Date: Jan 29, 2018 By: Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 4119 Btuh Ducts 1391 Btuh Central vent (51 cfm) 834 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 6026 Btuh Latent Cooling Equipment Load Sizing Structure 992 Btuh Ducts 368 Btuh Central vent.(51 cfm) 2114 Btuh Outside air Equipment latent load 3475 Btuh Equipment total load 9501 Btuh Req. total capacity at 0.70 SHR 0.7 ton Cooling Equipment Summary Make SENVILLE Trade Cond SENA-09HF-OZ Coil SENA/09HF/IZ AHRI ref 8797149 Efficiency 14.5 EER, 25 SEER Sensible cooling 6300 Btuh Latent cooling 2700 Btuh Total cooling 9000 Btuh Actual air flow 320 cfm Air flow factor 0.058 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.65 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Jan-29 12:54:19 wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ... s\Quick Calcs\Documents\McFARLANE ENCUSURE.rup Calc = MJ8 Front Door faces: N - wrightsoft° Right-M Worksheet Job: Entire House Date: Jan 29, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,iOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 31.0 ft 8.0 ft d 220.0 ftz NEW BEDROOM 31.0 ft 8.0 ft heat/cool 11.0 x 20.0 ft 220.0 ftz Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 T !�- .P 12E-Osw _4A5.2ob_,.__ 12E-Osw 4A52ob__-- _ 12C-0sw — 0.068 0.560, 0.068 0.560 0.07 1f 0.043 n _n_ w w_. __ - 1.90 _ 15.68 1.90 15.68 __ 2.55 1.20 V 1.35 _ 16.16 1.35 —0.00 1.40 86 ___.12 160 40 � 248 220 220 76 ,______Q 120 3 248 220 _.___M 31; 145 188. 228 _627 632, 265 _ 858. 4 103 _. 194 162 __- 1678 __0 307 88 12 76 0 4 145 188. 228 627 _ _632 265 858 103 194. 162 1678- _ Q 160 40 120 3 248. 220 __220 220 _ 248 220 31.: C F 17A-20xd 224_4pl 307 ____Q 0 989 ____ _27.6.9 ^— 0-00. ___.___ 0 6 c) AED excursion 829 829 Envelope loss/gain 2944 32741 2944 3274 12 a) Infiltration b) Room ventilation 551 0 155 0 551 0 155 0 13 Internal gains: Occupants @ 230 Appliances/other 3 690 0 3 690 0 Subtotal (lines 6 to 13) 3494 4119 3494 4119 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 25% 34% 0 0 0 3494 890 0 0 0 4119 1391 25% 34% 0 0 0 3494 890 0 0 0 4119 1391 Total room load Air required (cfm) 4384 3201320 5509 4384 320 5509 320 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. y ' wrightsOft54 - Right-Sufte® Universal 2017 17.0.14 RSU08101 2018-Jan-29 12:Page ge 1 1 ACC*` ...s\Quick Calcs\Documents\McFARLANE ENCUSURE.rup Calc = MJS Front Door faces: N