HomeMy WebLinkAboutApproved, Reviewed by G SMYTH Gen-Pro Wire Cut sheetR
e
v
DATE CHANGE DETAIL Draka Engineered Solutions
One Tamaqua Blvd
Schuylkill Haven PA 17972
Phone: 570-385-4381 Fax: 570-385-1092
0 10/12/17 New Issue
1 10/18/17 Changed PN, Cable Weight
2 10/24/17 Added JP installation under ratings
3
Project Name: Generac Approvals: Engineering: Final:
Draka Cableteq USA Inc. reserves the right to modify this information without prior
notification and does not make a warranty or representation of any kind, whether implied or
expressed with respect to the information contained herein. Draka Cableteq assumes no
risks, and will not be liable for direct or indirect, special; incidental or consequential damages,
any defect or personal injury resulting from the use of this document.
EngDrawing-Rev01-April07
Part Number: 382924
Quote Number: Q04278-3
File Number: type tc thhn-pvc 3C1AL 1C6AL 6C18BC 382924
GENERAC
Page Number: Page 1 of 2
Cable Engineered by Draka
600 Volt, Tray Cable
PVC/Nylon Insulated Circuit Conductors
Overall PVC Jacket
A
B
E
C
D
Components
A: (3) - #1 AWG Class B stranded, 8000 series, aluminum conductors w/50 mils (1.27 mm) heat and moisture
resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 7 mils (0.18 mm) nylon applied directly to the
surface of the insulation.
B: (6) - #18 AWG Class K stranded, soft drawn, bare copper conductors w/15 mils (0.38 mm) heat and moisture
resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 4 mils (0.10 mm) nylon applied directly to the
surface of the insulation.
C:(1) - #6 AWG Class B stranded, 8000 series, aluminum conductor w/30 mils (0.76 mm) heat and moisture
resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 5 mils (0.13 mm) nylon applied directly to the
surface of the insulation
D: Mylar binder tape.
E: 80 mils (2.03 mm) of heat and moisture resistant, polyvinyl chloride (PVC) jacket.
Print Legend
(UL) E60544 POWER AND CONTROL TRAY CABLE TYPE TC-ER-JP 1 AWG AL (42,4 mm2) 3/C + 6 AWG AL (13,3
mm2) 1/C GROUND THWN CONDS & 18 AWG (0,82 mm2) 6/C TFFN CONDS 600V 75C DRY/75C WET OIL RES I
SUNLIGHT RESISTANCE DIRECT BURIAL JOIST PULL GENERAC P/N AL1622 "sequential footage print"
Physical Characteristics
Cable Weight: 664 lb/mft (988 kg/km)
Copper Weight: 31 lb/mft (46 kg/km)
Aluminum Weight: 267 lb/mft (397 kg/km)
Nominal Cable OD: 1.130 in (28.7 mm)
R
e
v
DATE CHANGE DETAIL Draka Engineered Solutions
One Tamaqua Blvd
Schuylkill Haven PA 17972
Phone: 570-385-4381 Fax: 570-385-1092
0 10/12/17 New Issue
1 10/18/17 Changed PN, Cable Weight
2 10/24/17 Added JP installation under ratings
3
Project Name: Generac Approvals: Engineering: Final:
Draka Cableteq USA Inc. reserves the right to modify this information without prior
notification and does not make a warranty or representation of any kind, whether implied or
expressed with respect to the information contained herein. Draka Cableteq assumes no
risks, and will not be liable for direct or indirect, special; incidental or consequential damages,
any defect or personal injury resulting from the use of this document.
EngDrawing-Rev01-April07
Part Number: 382924
Quote Number: Q04278-3
File Number: type tc thhn-pvc 3C1AL 1C6AL 6C18BC 382924
GENERAC
Page Number: Page 2 of 2
Physical Characteristics
Conductor Color Code: 1 AWG - Black, White and Red
6 AWG - Green
18 AWG - Black, Red, Yellow, Yellow/Black, Blue and White
Jacket Color: Orange
Electrical / Optical Characteristics
Voltage: 600V
Specifications
Conductors: ASTM B 3, ASTM B 174, ASTM B 801
Insulation: ICEA S-95-658 (NEMA WC 70), ICEA S-73-532 (NEMA WC 57), UL 83 for Type THWN wires
Jacket: ICEA S-95-658 (NEMA WC 70), ICEA S-73-532 (NEMA WC 57), UL 1277
Ratings
UL THWN 600V
UL Type TC-ER-JP 600V
The insulation is acceptable for use in locations at 75 °C dry and 75 °C wet.
The cable is suitable for use in cable trays, aerial or direct burial installations.
The cable is JP rated for installation in accordance with Part II of Article 334.
Packaging
Bulk reels