Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BRADLEY PERMIT
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 3/24/2022 Permit Number: 0 X. Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial Residential X 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 CBDG Funding PERMIT APPLICATION FOR: `P}30PbS>rT? I�P�OU�MENT�LOGA1L01x! � 3 �_ _ x _ Address: 867 S KINGS HWY property Tax ID #: 2311-800 0001-000-4 Lot No. Site Plan Name: Project Name: RICHARD BRAD LIKE FOR LIKE AC CHANGE OUT 14 SEER 2 TON 5 KW New Electrical Meter Second Electrical Meter Additionalworl<tobeperformed underthlspermit—checl<allthatapply: (Affidavit required) Block No. XMechanical _GasTanl< _Gas Piping _Shutters _Windows/Doors _Pond _ Electric . Plumbing _ Sprinklers _ Generator _ Roof Pitch Total Sq. Ft of Construction: Cost of Construction: $ 11,490.00 RICHARD BRADLEY Address: 867 S KINGS_HWY Sq. Ft, of First Floor: Utilities: _Sewer _Septic BuildingHelght: city: FT PIERCE state: FL Zip Code: 34945 Fax; Phone No. 772-595-6800 E- mail: Fill in fee simple Title Holder on next page (if different from the Owner listed above) Name: Christopher Langel Company:gaa Rna¢f A/C am 4h Pt t4afal Ins Address: 3108 INDUSTRIAL 31ST STREET CRy: FT PIERCE State: FL Zip Code: 34946 Fax: 772-448-4416 Phone No 772-466-2400 E-Mail INFO@SEACOASTAI R.COM Sta te or County License CMC03543_1 f value of construction Is 2500 or more,aRECORDED Notice of ICommencement Is requlred. If va1ue of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required, DESIGNER/ENGINEER: _Not Applicable Name; MORTGAGE COMPANY: — Not Applicable Name: Address: Address: City: Zip: Phone: State: City: State, _ Zip:_ Phone FEE SIMPLE TITLE HOLDER: _ Name; Not Applicable BONDING COMPANY: Name: Not Applicable Address: Address: . -.. City; City; Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application Is hereby made to obtain a permit to do the work and Installation as indicated. certify that no work or Installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which confilcts with anV applicable Homeowners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Homeowners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review; room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property. A Notice of Commencement must be recorded in the public records of St. Lucie County and posted on the jobsite before the first inspection, If you intend to obtain financing, consult e,I+l, lnnrloe nr an artnrnpv hpfnro rnlnmpnninP work or recordln2 vour Notice of Commencement, VVIU4 Signature of Contractor -or -Owner Builder as applicable STATE OF FLORIDA COUNTY OF ST LUCIE Sworn to (or affir rAi ubscribed before me of X Physical Presence or _ Online Notarization this 24 day of 2022 by CHRISTOPHER LANGEL Name of person making statement. Personally Known X_ OR Produced identification Type of Identification Produced, I L) hp N a C R mlLuy L l an YA o ( nature of Notary Public -state o Florida) )l0 I {rfi tit"••. JUSTINAL.HOPKINSCONNELLY Commission No eel ;:fl•_ .l`-riq��7. MYCOMMISSIONN0094066;EXPIRES;Decembr17, SAR"� 2023�• Bonded Thm NoleryPuLllcUnd¢nnitar¢ REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED _ Rev 1o/11/t1 AHRI Certified Reference Number: 9762639 Date:03-23-2022 AHRI Type : RCU-A-CB (Split System: Air -Cooled Condensing Unit, Coil with Blower) Series: 14 SEER W SERIES R410A AC Outdoor Unit Brand Name: GRANDAIRE Outdoor Unit Model Number (Condenser or Single Package) : WCA4244GKA** Indoor Unit Model Number (Evaporator and/or Air Handler) : WAPL244A* Lt�,rt.ct Model Status :Active Region : Southeast and North (AL, AR, DC, DE, FL, GA, Hi, KY, LA, MD, MS, NC, OK, SC, TN, TX, VA, AK, CO, CT, ID, IL, IA, IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SD, UT, VT, WA, WV, WI, WY, U.S. Territories) Region Nole : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. f"Active" Model Status are those Thal an AHRI Certification Program Participant Is currently producing AND selling or oNering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT Is still Ratinas that are acocomoanied by WAS indicate an involuntary re -rate. The new Published Patine is shown alone with the Previous (i.e. WAS) Patine. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, tIne protluct(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or pertormance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahrid Irectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information forthe model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life better^ and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which Is listed above, and the Certificate No., which is listed at bottom right. ©2022Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132925354694359931