HomeMy WebLinkAboutLetter - Concrete Restoration Exterior Balconies.II
2431 SE Dixie Highway
Stuart, FL 34996
Phone: (772) 287-0525
MATHERS ENGINEERING EB#0004456
CORPORATION
Post -Building Permit Addendum Engineer's Field Observation Report #1
Date: April 28, 2021
To: Plan Reviewer
St. Lucie County Building Department RECE�vEo
2300 Virginia Avenue MAR 2 ZU1
Fort Pierce, FL 34982
6s, �W.OfM10tlrign�Y
Contractor: DFM Construction
312 S. Old Dixie Hwy.
Jupiter, Florida 33458
Referenced Project: Concrete Restoration for Exterior Balconies
For Oceanrise Condominium
Located at 10310 S. Ocean drive, Jensen Beach, FL 34957
Permit # SLC 2003-0510
.For Stack 2 mi t - UMMI ers (102, 202, 302, 402, 502, 602 and 702)
Mathers Engineering Corporation visited the job site and made the following observations of the
ongoing concrete restoration and repairs of exterior balconies:
Site Observations thru 04/27/2021:
Stack #2:
• Unit 102: Shutters removed.
• Unit 202: Shutters remove.
• Unit 302:
Shutters and guardrail removed.
• Unit 402:
Shutters and tile removed.
• Unit 502:
Shutters, guardrail and tile removed.
• Unit 602:
Shutters and tile removed.
• Unit 702:
Shutters and guardrail removed.
Limitations:
Our professional services have been performed, our findings obtained, and our opinions prepared, in
accordance with general accepted engineering principles and practices. This company is not
responsible for the conclusions, opinions or recommendations made by others based on our findings.
Approved MJ - A T /�
cEN
Ao
William J. t�
Florida License
Florida SI #155
A1�
2431 SE Dixie Highway
Stuart, FL 34996
Phone: (772) 287-0525
MATHERS ENGINEERING EB#0004456
CORPORATION
Post -Building Permit Addendum Engineer's Field Observation Report #2
Date: May 13, 2021
To: Plan Reviewer
St. Lucie County Building a��
ding Department ����o
2300 VirginiaAvenue
Fort Pierce, FL 34982 �� ti��'
MPS cp,
Contractor: DFM Construction
312 S. Old Dixie Hwy.
Jupiter, Florida 33458
Referenced Project: Concrete Restoration for Exterior Balconies
For Oceanrise Condominium
Located at 10310 S. Ocean drive, Jensen Beach, FL 34957
Permit # SLC 2003-0510
For Stack 2 Unit Numbers (102, 202, 302, 402, 502, 602 and 702)
Mathers Engineering Corporation visited the job site and made the following observations of the
ongoing concrete restoration and repairs of exterior balconies:
Site Observations thru 05/11/2021:
Stack #2:
• Unit 102: Shutters removed.
• Unit 202: Shutters remove.
• Unit 302: Shutters and guardrail removed. Chipping is underway for concrete deck.
• Unit 402: Shutters and tile removed.
• Unit 502: Shutters, guardrail and tile removed. Chipping is underway for concrete deck.
• Unit 602: Shutters and tile removed.
• Unit 702: Shutters and guardrail removed. Chipping is underway for concrete deck.
Limitations:
Our professional services have been performed, our findings obtained, and our opinions prepared in
accordance with general accepted engineering principles and practices. This company is not
responsible for the conclusions, opinions or recommendations made by others based on our findings.
\��\�11111111//����
Approved by: � �P -3 ' MA
,4_
TAT OF - FI�� C®�
pp <C/
William J. Mathers,�lSi IFS NPLE\�����
Florida License PE #19CiS811111111 \��
Florida SI #155
2431 SE Dixie Highway
Stuart, FL 34996
Phone: (772) 287-0525
MATHERS ENGINEERING EB#0004456
CORPORATION
Post -Building Permit Addendum Engineer's Field Observation Report #3
Date: October 20, 2021
To: Plan Reviewer
St. Lucie County Building Department
2300 Virginia Avenue Fort Pierce, FL 4982 �\y�o Otiti
Contractor: DFM Construction
312 S. Old Dixie Hwy.
Jupiter, Florida 33458
Referenced Project: Concrete Restoration for Exterior Balconies
For Oceanrise Condominium
Located at 10310 S. Ocean drive, Jensen Beach, FL 34957
Permit # SLC 2003-0510
For Stack 2 Unit Numbers (102, 202, 302, 402, 502, 602 and 702)
Mathers Engineering Corporation visited the job site and made the following observations of the
ongoing concrete restoration and repairs of exterior balconies:
Site Observations thru 09/15/2021:
Stack #2:
• Unit 102:
Concrete restoration has been completed.
• Unit 202:
Concrete restoration has been completed.
• Unit 302:
Concrete restoration has been completed.
• Unit 402:
Concrete restoration has been completed.
• Unit 502:
Concrete restoration has been completed.
• Unit 602:
Concrete restoration has been completed.
• Unit 702:
Concrete restoration has been completed.
Limitations:
Our professional services have been performed, our findings obtained, and our opinions prepared in
accordance with general accepted engineering principles and practices. This company is not
responsible for the conclusions, opinions or recommendations made by others based on our findings.
Approved by: \�\\\\111I I//////�
3. M.
NS
19658
S
William J. N1 hers '•..�9 .• G�� ���
Florida License PE #�A3o/ONA������
Florida SI #155 ���/11 I IIII\\\
2431 SE Dixie Highway
Stuart, FL34996
MATHERS ENGINEERING Phone: (772) 287-0525
CORPORATION EB#0004456
FINAL CLOSE-OUT ON RESTORATION WORK
Date: October 20, 2021 REVIEWED FOR
To: St. Lucie County Building Department CODE COMPLIANCE
2300 Virginia Avenue St, LUCIE O
Fort Pierce, FL 34982 COUNTY
SOCC
Referenced Project: Concrete Restoration for Common Walkways and Exterior Balconies
(decks, beam & columns)
For Stack 2 Unit Numbers (102, 202, 302, 402, 502, 602, and 702) for
Oceanrise Condominium
Located at 10310 S. Ocean Drive, Jensen Beach, FL 34957
Contractor: DMF Construction
312 S. Old Dixie Hwy., Jupiter, FL 33458
Permit No. 2003-0510
The completed concrete restoration did not reduce the structural integrity of the remaining existing
structural systems and, therefore, a requirement to upgrade them by this permit was not warranted.
Existing building's components and elements outside the renovation area of this permit do not have their
current wind load resistant capacity or gravity load capacity compromised by the completed concret
restoration.
Mathers Engineering Corporation performed onsite inspections as the job progressed. Repairs did not
require shoring.
As the demolition exposed areas of exterior concrete deterioration and steel corrosion of the exterior
balcony deck, we initiated and inspected restoration work such as concrete preparation, steel
reinforcement restoration, and application of bonding agents, and finished concrete applications. The
enclosed Record Drawing (Sheet 1) shows the areas of repair for Stack 1 and is made part of this final
close-out document approval under Permit Number 2003-0510.
Materials used and work performed to date has been substantially completed in conformance with the
specifications outlined in the IRCI Guideline No. 03730, as well as the applicable 2017 Florida Building
Codes, 6t' Edition (and updat , other industry guidelines, or standard engineering practices.
Approved by, -. Arti
�� � DENS •,� �i
�0
William J. Mathers,� S/ At- ������\ FILE C®pV7
Florida License #19658 /1/ 1 II111��
Special Inspector FL License #SI-155