HomeMy WebLinkAboutAPPROVED - Metal Approval.pdf31912Z 10:22 AM Florida Building Code Online
FLEWMA - Inv I tlf
Business & Professional Regulation
BCiS Home Log in User Registration Hot Topl>s submit surcharge Slats B Facts Publications Contact Us BCIS Site Map Links Search
dbpr��IProduct Approval
�w. USER: Public User
Product Approval Menu > Product or Apph[ation Search > Apph[ation List > AppnGtfon Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL29523-RI
Revision
2020
Approved
Metal Alliance Inc.
2120 SW Poma Dr.
Palm City, FL 34990
(844)638-2548
orders@metalalliance.com
Tara Faulkner
orders@metalalliance.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2030
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL295J.3 R1 C I 32AI 100SL plywood nonHVHZ.ndf
Standard Year
TAS 100 1995
TAS 125 2003
UL580 2006
hftps:iffloridabuilding.org/pr/pr app_dO,aspx?param=wGEVXQvADquDjJZOKCHOBeuJtRZVS4wAPLbCuLWfBsMqrM4sxtfrSA%3d%3d 1/3
319122, 10:22 AM Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
08/11/2020
08/13/2020
08/19/2020
10/13/2020
Model, Number or Name Description
FL #
2952.3.1 01: 100SL 1" Nailstrip 032 Aluminum 100SL 1" Nallstrip panel from nominal 0.032" aluminum or
thicker an 15/32" (min) plywood or 3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL29523 RI 11 32AI 1005L pjywood nonHVHZ pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: 168.5 psf @ 6" oc EL22523 RI AE t._A6 1Q ,Sj lywood nonHVHZ.W
Created by Independent Third Party: Yes
29523.2
02: 100SL 1" Nallstrip 24ga
100SL i" Nailstrip panel from 24ga (min) on 15/32" (min)
plywood or 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL29523 R1 II 24ga !00SL ywood noaHVHZ.pd
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Patty: Yes
Design Pressure: +N/A/-206
Evaluation Reports
Other. 206 psf @ 6 " oc
F1.29523 R1 AE 24ga 10051. plywood nonHVHZ.Qd
Created by Independent Third Party: Yes
29523.3
03: 100SL 1" Nailstrip 26ga HVHZ
100SL 1" Nallstrip panel from 26ga (min) on 15/32" (min)
plywood or 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL29523 RI II 26ga 100SL oiywoad.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design pressure: +N/A/-176
Evaluation Reports
Other: 176 psf @ 6" oc WITH sealant, 116 psf @ 6" oc without
FL29523 RI AE 26ga 1005L plywood.p�
sealant
Created by Independent Third Party: Yes
29523.4
04: 100SL 1" Nailstrip 032 Aluminum
100SL 1" Nallstrip panel from nominal 0.032" aluminum or
HVHZ
thicker on 15/32" (min) plywood or 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FIr79_525 R1 I1 32A) 1005L ply Q2_0 psf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-175
Evaluation Reports
Other: 175 psf @ 6" oc WITH sealant
FL29523 RI AE 32AI 10051- Ply mLiziff
Created by Independent Third Party: Yes
29523.5 05: 1505L 1.5" Nallstrip 24ga
150SL 1.5" Nallstrip panel from 24ga (min) on 15/32" (min)
plywood or 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL29523 R1 II 24ga 150SLgjywood nonHVHZ.odf
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-153.5
Evaluation Reports
Other: 153.5 psf @ 6" oc WITH sealant
FL29523 R1 AE 24gA---1.5OSL plywood nonHVHZ.odf
Created by Independent Third Party: Yes
29523.6
06: 150SL 1.5" Nailstrip 032
150SL 1.5" Nailstrip panel from nominal 0.032" aluminum or
Aluminum
thicker on 15/32" (min) plywood or 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-168.5
Other: 168,5 psf @ 6" oc WITH sealant
FL29523 R1 II 3ZAI 150SL plywood ronHVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL29523 R1 AE 32AI 150SL plywood nonHV p ff
Created by Independent Third Party: Yes
29523.7 07: 150SL 1.5" Nailstrip 032
150SL 1.5" Nailstrip panel from nominal 0.032" aluminum or
Aluminum HVHZ
thicker on 15/32" (rain) plywood or 3/4" (min) wood plank
19" coverage
Limits of Use
Installation Instructions
https:llfloridabuiiding.org/prlpr_app_dil.aspx?param=wGFVXQwtDquDjJZOKCHOBeuJtRZVS4wAPLbCuLWf8sMgrM4sxtfrSA%3d%3d 2/3
319122, 10:22 AM
Florida Building Code Online
Approved for use in HVHZ: Yes
FL29523 Rl 1I 32AI 1505L olylygglLRUf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.1
Evaluation Reports
other: 168.1 psf @ 6" oc WITH sealant
FL29523 R1 AE 32AI 1505L piywood.Ddf
Created by Independent Third Party: Yes
29523.8
08: 1505L 1.5" Nailstrip 24ga HVHZ
1505L 1.5' Nailstrip panel from 24ga (min) an 15/32' (min)
plywood or 3/4" (min) wood plank 1 19" coverage
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL29523 Rl 11 249a_150SL_plyly22CL f
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-112.5
Evaluation Reports
Other. 112.5 O 6" oc WITH sealant
FL29523 Rl AE 24ga 1505L plyyyggg,Rgf
Created by Independent Third Party: Yes
ead Heat
candid�
The State of Florida Is an AA/EEO employer
Under Monte law, email addresses arc public reconls. If you do not want your e-mail adores released in response to a public-recnrtls request, do not send electronic
mall to this entity. Instead, mntact the office by phone or by traditional mall. If you have any questions, please contact 950Aa7.1395. *Pursuant to Sector, 455.275(1),
Flomia Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address If trey have one. The emalls
provided may be used for official communication with Me tcensee. However email addresses are public record. it you do not wish to supply a personal address, please
provide One Department with an email address which can b , made avallabie M the public To determine if you are a Ikensee under chapter 455, ES., please dick hdaL.
Product Approval Accepts:
Credit Card
Safe
https://8oddabuilding.orglpr/pr_app_d8.aspx?param=wGEVXQvRDquDjJZOKCHOBeuJtRZVS4wAPLbCuLWfBsMgrM4sxtfrSA%3d%3d 3/3
Ak
METALALLIANCE
A Value Added Supplier of Metals
1" NailStrip 26ga Steel Panels
26ga (min) 1" Nail Strip over 15/32" (min) plywood
Metal Alliance, Inc
2120 SW Poma Dr I Palm City FL 34990
Produced by Metal Alliance's Network of Approved Regional Manufacturers
Product Description
Nailstrip, snaplock style panel with a 16" maximum panel width and a
nominal rib height of 1"
Product Material
26ga (min) steel
26ga is nominally 0-0185" with yield strength of at least 50ksi, and shall be corrosion
resistant per FBC 1507.4.3 where required.
Fastener
#10 1-inch pancake style fastener
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville F
FL PE 81377 1 FL CA 33344
www.TimberLakeCove.com
100SL�
1" NAILSTRIP 26GA
\fit k II III I , , / ,
\OPJ�D
vCENsj
No. 81377
0 STATE OF ((yam
ORkO
////`S'/0NhJ David E Eng
2020.08.12
07:12:16-04'00'
This item has been digitally signed and sealed
by 0 E Eng. PE. on the date indicated Printed
copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies
Underlayment: Comply with local building code or FBC 1507.1.1/1518.2 where required.
Slope: Comply with local building code or FBC 1507.4.2/FBC 1515.2 where required.
Re-ROOfing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511/1521, provided the existing roof meets the conditions required
by the applicable code.
Fire Barrier: Comply with FBC 1516.1 and 1516.2 where required.
Maximum Allowable Loads & Installation Requirements:
Method A: #10 x 1" fastener at 6" o_,c_along nail strip: 116 PSF
Method_B;_#10 x 1" fastener at 6" o.c. along nail strip WITH sealant: 176 PSF
A factor of safety of 2 has been applied.
Fasteners are installed through the metal flange, NOT through the pre -punched slots.
Technical Documentation:
This product has been tested to the TAS 125 / UL 580-06 standard by Intertek Testing (TST-1527),
report J6368.17-450-44 RO and to TAS 100 under report J6368.33-450-44 RO.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2
(non-HVHZ) and 1518.9.1/1523.6.5.2.4 (HVHZ), as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
• TAS 125 - Standard Requirements for Metal Roofing Systems
• TAS 100 - Wind and Wind -Driven Rain
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any
company manufacturing or distributing products under this evaluation. The some entities do
not have, nor will acquire, a financial interest in any other entity involved in the approval
process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be
completed by others. Fire classification and shear diaphragm design are outside the scope of
this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as
required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible
for any conclusions, interpretations, or designs made by others based on this evaluation
report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no
express or implied warranty regarding performance of this product.
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use
of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
AM
METALALLIANCE
A Value Added Supplier o1 Metals
Instructions:
Select the appropriate load table that applies to
the structure in question.
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
a
♦ 3 a 2 2 3
\
2 2
2
2 1 2 2 3 a
2 2 3
2 a
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone 2 1 1 2
concept. For the load tables below, the worst case
was taken for each zone and reported using the a 3.3 a
standard zones 1-2-3: t J f
Zone 1 includes zones 1 and 1' -a- HIPROOF GABLEROOF -'a—
Zone 2 includes zones 2e, 2r, and 2n
ix rc.�, IumR,u oua„mx, w i.. roiaA�en Is suu.ew mu, r.n
Zone 3 includes zones 3e and 3r ;Ls„~.„L,�L.,.aLF.F, ro„,:w,,.o„.L,,,„»,�, _•,�..,
n„ w auLwuuo u. w�„;„R..r„L„.eu,uxu <.wL
Combining these zones creates a clear, simple
scheme, at the expense of some design efficiency.
Contact Metal Alliance Inc for further information,
or consult a licensed design professional.
METHOD A
(0 `L WAI F I FG SNAPS
ONTO MALE LEG
ijgV1) �i10 FASTENER
AI vO11
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gable/hip roof with max slope of 45'
Have a mean Roof Height of 30 feet or less
ROOF ZONES FOR GENERIC BUILDING
[AAMWESIM
r 1 f.lgl l I L G SNAPS
ONTO ANLE LEG
SEALANT APPLIED TO
IIASf OI MAI I I I(]
a10 FASTENER
A' 1-111
Use this load table for structures which meet the following criteria'
Are located in 8, C, or D exposure area
Have either a flat roof, or gable/hip roof with max slope of 45°
Have a mean Roof Height of 30 feet or less
FL29523.03: 26ga 100SL 1" nail strip on 15/32" plywood FL29523.03: 26ga 100SL 1" nail strip on 15132" plywood
Wind
105
110
120
130
140
150
160
170
180
190
200
Wind
105
110
120
130
140
150
160
170 180 190 200
Zone 1:
A
A
A
A
A
A
A
A
A
A
A
Zone 1:
A
A
A
A
A
A
A
A A B B
Zone 2:
A
A
A
A
A
A
A
A
A
A
B
Zone 2:
A
A
A
A
A
A
B
B B B
Zone 3:
A
A
A
A
A
A
A
A
A
B
B
Zone 3:
A
A
A
A
A
B
B
B
Use this load table for structures which meet the following criteria:
Use this load table for structures which meet the following criteria.
Are located in Exposure 8 area
Are located in B, C, or D exposure area
Have either a flat roof less than 70, hip roof with
Have either a Flat roof less than 7°, hip roof with
max slope of 45°, or gable roof with slope between 20' and 45'
max slope of 45°, or gable roof with slope between 20' and 45'
Have a mean Roof Height of 30 feet or less
Have a mean Roof Height of 30 feet or less
FL29523.03: 26 a 100SL 1" nail strip on 15/32" plywood
d
FL29523.03: 26cia 100SL 1" nail strip on 15/32" pl:BB
Wind 105 110 120 130 140 150 160 170 180 190 200
Wind 105 110 120 130 140 150 160 170 18000
Zone 1: A A A A A A A A A A A
Zone 1: A A A A A A A A AB
Zone 2: A A A A A A A A A A A
Zone 2: A A A A A A A B B
Zone 3: A A A A A A A A A A B
Zone 3: A A A A A B B B B
METALALLIANCE
A Value Added Supplier of Metals