HomeMy WebLinkAboutAPPROVED- Underlayment Approval.pdf319122, 10:25 AM Florida Building Code Online
-40
. r . i�`
t rt r v �.�.,.r�,
1305 Home Log In User Registration Hot Topics submit Surcharge Stats & Facts Publications Contact us SCIS Site dlap Links Sedreh
dbpr
Product Apprpval
USER: Public User
Procluj _AgRril"i Menu 5 Pratluu or ARbhCatlon Search n &Rlicaticin Llsl > Application Detail
FL # FL21895-R4
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Sentry Building Innovations
Address/Phone/Email 1209 Orange Street Wilmington
New Castle, DE 19801
(604) 612-5289
mseth@sentrybuilding.com
Authorized Signature Marsha Hollandsworth
M h o l landsworth@sentrybu i Id i ng. co m
Technical Representative Marsha Hollandsworth
Address/Phone/Email 1209 Orange Street Wilmington
New Castle, DE 19801
(843) 735-1773
Mhollandsworth@sentrybuilding.com
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Vnderlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
QAI Laboratories
Quality Assurance Contract Expiration Date
12/31/2025
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
FL21895 R4 C01 2021 01 COI NIEMINEN.pgf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D1970
2015
ASTM D4533
2015
ASTM D4798
2011
ASTM D4869
2016
ASTM D5035
2011
FRSA/TRI, Sixth Edition
2018
UL1897
2015
Equivalence of Product Standards
Certified By
https:llfloridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDqufjjgQzTt6YQnnxswE3xiGMTtl uPIXPB3FkJfAoT5OL3Q%3d%3d
1/2
319122, 10:25 AM
Florida Building Code Online
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending F6C Approval
Date Approved
Summary of Products
FL #
21895.1
Model, Number or Name
Roofnado Synthetic Roofing
Underayments
Method 1 Option D
12/17/2021
12/20/2021
12/23/2021
02/08/2022
Limits of Use
Approved for use in NVN2: No
Approved for use outside NVN2: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-97.5
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
design pressure herein pertains to one underlayment assembly
for use in tile mof systems. Refer to ER Section 5.8.3.
Description
Synthetic roofing underlayments
Installation Instructions
FL21895 R4 II 2021 12 17 FINAL SENTRY FL21895-R4 odf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL21895 R4 AE 2021 12 17 FINAL SENTRY FL21895-
FA,Qdf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road Tallahassee, FL 32399 Phone: 850187-11124
The State of Parts Is an AA7EE0 employer. Coovdoht 200A8113 Smfe of Florida.:: Privacy, Statement :: AccGsa1b111N Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public-repurds request, do not send electronic
mall to Nis entity. Instead, contact the Office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(I),
Florida Statutes, enedive October I, 2012, licensees licensed under chapter 455, F.S. must provide me Department with an email address If they have one. The entails
provided may be used for offoal communleamen with me licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine It you are a IImmuse under chapter 455, F.S., please dick bee.
pra4YQ approval Accepts:
® EE
Credit Card
Safe
https:ltforidabuilding.org/pr/pr_app_d8.aspx?param=wGEVXQwtDquflj9QzTt6YOnnxswE3x!GMTtluPIXPB3FkJfAoT5OL3Q%a3d%3d 212
0
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
1N RFYr1
Sentry Building Innovations Evaluation Report 13925.02.17-1-R4
1209 Orange Street, Wilmington, FL21895-R4
New Castle, DE 19801 Date of Issuance: 02/16/2017
(843) 735-1773 Revision 4:12/17/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance
with the 7th Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Roofnadoiaa Synthetic Roofing Underlaymertts
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes
to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review
of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Evaluated" may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6
Prepared by:
Robert J.M. Nieminen, P.E.
=ta The facsimile sea I appearing was authorized by Robert
�0•.E$�;i_r•y, Thi5does
E: ,; Merriman. P.E. on 12/17/2021. not serreasan
Florida Registration No. 59166, Florida DEA ANE1983.'+.,,`,�.^"
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products It evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have norwill acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
®2018, NEMO ETC, LLC
ONEMO etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roofnad6m Synthetic Roofing Underlayments, as produced by Sentry Building
Innovations, have demonstrated compliance with the following sections of the 7* Edition (2020) Florida Building
Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to
the Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
1504.3.1
1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1,
R905.2.8.2
1507.1.1.1(2&3, Exception), 1507.1.1.1(5) /
R905.1.1.1(2&3, Exception), R905.1.1.1(5)
1507.1.1.1(2&3, Exception), 1507.1.1.1(5) /
R905.1.1.1(2&3, Exception), R905.1.1.1(5)
1507.1.1.1(5) / R905.1.1.1(5)
1507.3.3 / R905.3.3
TA5110
Properties
Wind resistance
Material standard
Tear strength
Tensile strength
Liquid water transmission
Material standard
Accelerated Weathering
Standard Year
UL1897 2015
ASTM D1970 2015
r_c1lIriaoil M
ASTM D5035 2011
ASTM D4869 2016
FRSA/TRI, Sixth Edition 2018
ASTM D4798 2011
3. REFERENCES:
Entity
Examination
Reference
Date
NEMO
Evaluation Report
lm-ACT-I9-FBCER.08.19-2-R2
11/19/2020
NEMO (TST6049)
UL 1897
4L-ACT-18-002.07.18-2
07/05/2018
NEMO (TST6049)
AC152
4S-ACT-18-001.10.18-10
10/08/2018
NEMO (TST6049)
FRSA/TRI Manual
45-ACT-18-001.11.18-26
11/12/2018
QAI(TST9808)
ASTM D1970
RJ5365P-3
04/26/2017
QAI(TST9808)
ASTM D1970 (adhesion)
RJ5365P-4
06/29/2017
QAI(TST9808)
ASTM D1970
RJ7717-3
06/11/2020
QAI(TST9808)
ASTM D1970 (adhesion)
RJ7717-4
06/11/2020
QAI (QUA7628)
Traceability/Inspections
Service Confirmation
08/12/2019
QAI (QUA7628)
Quality Assurance
Florida 8CIS
Current
4.
PRODUCT DESCRIPTION:
PRODUCT
MATERIAL STANDARD
PLANT(S)
DESCRIPTION
4.1
Roofnado—
1507.1.1.1(2&3, Exception),
India
Synthetic polymer -based scrim -reinforced underlayment,
AnchorDeck'"
1507.1.1.1(5) /
consisting of woven polyolefin base with a layer of
R905.1.1.1(2&3, Exception),
nonwoven polyolefin sheet and a polymer coating on the
R905.1.1.1(5)
back side, with a nominal unit weight of 2.25 Ibs/square.
4.2
Roofnado—
1507.1.1.1(2&3, Exception),
India
Synthetic polymer -based scrim -reinforced underlayment,
StormTread"
/
consisting of woven polyolefin base with a layer of
R905.1.1.1(2&3, Exception),
nonwoven polyolefin sheet and a polymer coating on the
R905.1.1.1(5)
back side, with a nominal unit weight of 3.80 lbs/square.
4.3
Roofnado'"
1507.1.1.1(2&3, Exception),
India
Synthetic polymer -based scrim -reinforced underlayment,
ShingleLock'
1507.1.1.1(5) /
consisting of woven polyolefin base with a layer of
R905.1.1.1(2&3, Exception),
nonwoven polyolefin sheet and a polymer coating on the
R905.1.1.1(5)
back side, with a nominal unit weight of 3.80 Ibs/square.
NEMO ETC, LLC Evaluation Report 13925.02.17-1.R4
Certificate ofAuthoraotion p32455 7" EDITION (2020) FBC NON-HVH2 EVALUATION FL11895-R4
Roofnado" Synthetic Roofing Undedayments Revision 4: 12/17/2021
Page 2 of 6
4.4
4.5
ONEIVIO etc.
PRODUCT
MATERIAL STANDARD
PLANT(s) I
DESCRIPTION
RoofnadoTM
ASTM D1970 (Table 1)1 &
United
Self -adhering underlayment consisting of a synthetic top-
LapLock'" PSU
FRSA/TRI 09-18
Arab
facer, polymer modified bitumen and a release liner,
Emirates
available in rolls 36-inch x 67-ft with a nominal 60-mil
thickness.
Roofnado"'
ASTM D1970 (Table 1)1
United
Self -adhering underlayment consisting of a synthetic top-
AnchorDeck'"
Arab
facer, rubberized adhesive and release liner, available in
PSU
Emirates
rolls 36-inch x 67-ft with a nominal 40-mil thickness.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Roofnadom Synthetic Roofing Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority
Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.6 Allowable roof covers:
TABLE 1: ROOF COVER OPTIONS
FBC NON-HVNZ:
15072
1507.3
1507.4 A1507.5
1507.7
1507.8 A 1507.9
Clay and Concrete Tile
Metal
Slate or
wood
Underlaymerlt
Asphalt
Shingles
Slate -Type
Mechanical
Adhesive-
Panels
Shingles
Shingles
Shakes
Attach
Set
Shingles
Roofnado—
Yes
No
No
Yes
Yes
Yes
No
AnchorDeckT
(residential)
(residential)
Roofnado"
Yes
No
No
Yes
Yes
Yes
No
StormTreadT"
Roofnado'"
Yes
No
No
Yes
Yes
Yes
No
Shinglel-ock'"
Roofnado"'
Yes
Yes
Yes
Yes
Yes
yes
Yes
Qointstdps, 15071.1.3/
LapLock'" PSU
(see 5.6.1)
R905.1.1.3)
Yes
RoofnadoTM
Yes
rNo
No
Yes
Yes
Yes
0oint wipe, 1507.1.1.3/
AnchorDeck— PSU
R905.1.1.3)
1 Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip
resistance for Roofnado"' LapLock- PSU and Roofnodo"' AnchorDeck"' PSU.
NEMO ETC, LLC Evaluation Report 139ZS.02.17-1-R4
Certificate ofAuthorizaoan 832455 71" EDITION (2020) FBC NON-HVHZ EVALUATION FL21895-R4
Roofnado-synthetic Roofing Underlayments Revision 4: 1Z/17/2021
Page 3 of 6
ONEIVIOletc.
5.6.1 Adhesive -set tile is limited to use of following underlayment /tile adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE ADHESIVE COMBINATIONS2
Underlayment
Adhesive
Florida Product Approval
Roofnadom LapLock' PSU
ICP Adhesives "Polysete AH-160"
FL6332
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads for project)
Underlayment
Application
Type
Primer
Material(s)
Deck / sheathing
(Optional) ASTM D41
plywood or OSB
Roofnado— Lapi ockT PSU
self -adhering
Base sheet
None
ASTM D226, Type II felt
Roofnado— AnchorDeck T'
self -adhering
Deck / sheathing
None
plywood or OSB
PSU
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be In accordance with the manufacturer's installation
instructions, but not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Gay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
q1 Maximum Design Pressure =-97.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41
Underlayment: Roofnado' LapLockT PSU, self -adhered and back -nailed 12-inch D.C.
I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report 13925.02.17-1-R4
Certificate of Authorization a32455 77' EDITION (2020) FBC NON-HVHZ EVALUATION FL21895-R4
Roofnado- Synthetic Roofing Underlayments Revision 4:12/17/2021
Page 4 of 6
ONEMOJetc.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover Installation Type
Maximum Exposure (days(
Roofnado"" AnchorDeck"', Roofnado"
StormTreadTM, RoofnadoTM ShingleLock"'
Mechanically attached
30
or Roofnado`" AnchorDeckTM PSU
Adhesive -set tile
90
Roofnado'" Laplock"' PSU
Mechanically attached
90
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlaymem
Tile Profile
Staging Method
Maximum slope
Roofnado"' LapLockTM PSU
Flat or Lugged
Max. 10-tile stack
4:12
6.1 RoofnadoTM Synthetic Roofing Underlayments shall be installed in accordance with the manufacturer's published
installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application.
6.3 Roofnado"' AnchorDeck^', Roofnado"StormTreacl " or Roofnado"' ShingleLock":
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception),
1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception)
or R90S.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturers installation instructions.
6.3.2 Fasteners:
Minimum fasteners shall be corrosion resistant, ring -shank cap nails shall be as set forth in FBC 1507.1.1.1 or
1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3.
6.4 Roofnado'" LapLock" PSU:
6.4.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type 11 felt, the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.2 Tile Applications:
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturers installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
NEMO ETC, LLC Evaluation Report 13925.02.17-1-R4
Cerxfimte o)Avthor2060n A32455 7"EDITION 12020)FBC NON-HVHZ EVALUATION FL21895-R4
Roofnado'" Synthetic Roofing Underlayments Revision 4: 12/17/2022
Page 5 of 6
ONEMOletc.
6.5 Roofnado" AnchorDeck^ PSU:
6.5.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTNf D1970) in
FBC 1507.1.1.1 or 1SO7.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 OA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QAI Laboratories—QUA7628; (604) 527-8378, mlansdowneq.
END OF EVALUATION REPORT -
NEW ETC, LLC Evaluation Report 13925.02.17-1-R4
Certificate of Authorization 432455 7T" EDITION (2020) FeC NON-HVHZ EVALUATION FL21895-R4
Roofnado- Synthetic Roofing Underlayments Revision 4: 22/27/2022
Page 6 of 6