HomeMy WebLinkAboutNOAM I® DAUE REVI,EWED FOR MIAMI-DADE COUNTY ,,��aa ��ee PRODUCT CONTROL SECTION `BODE COMPLANCE 11805 SW 26 Street, Room208 DEPARTMENT OF REGULATORY AND ECONOMI -SOU II� �® Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION �+ ° ®� ®f"bO U N p lfl' (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA Karnak Corporation 330 Central Avenue Clark, NJ 07066 www.miamidade.gov/economy CEIVED MAR 0 9 2022 SCOPE: ST. Lucie County, Permitting This NOA is being issued under the applicable rules and regulations governing the use of construc ion materials. The documentation submitted has been reviewed and accepted by Miami -Dade County. RER - Product .Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revolve, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:: Karnak Coatings and Cements LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 19-0925.01 and consists of pages 1 through 9. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 21-0706.03 Expiration Date: 09/13/26 Approval Date: 09/02/21 Page 1 of 9 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Cements and Coatings Materials: Asphalt SCOPE: . This approves Karnak Coatings and Cements, for use on existing roof assemblies, as described in this Notice of. Acceptance, designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. EVIDENCE SUBMITTED: Test Ageney Test Identifier Test Name/Reyort Date UL LLC R12199 UL 790 06/09/21 PRI Construction Materials KAR-033-02-61 ASTM D 4586 02/09/12 Technologies,. LLC KAR-034-02-01 ASTM D 4586 02/09/12 KAR-035-02-01 ASTM D 4586 02/09/12 KAR-036-02=01 ASTMD 4586 02/09/12 KAR-037-02-01 ASTM D 4586 02/09/12 KAR-038-02-01 ASTM D 4586. 02/09/12 KAR-039-02-01 ASTM D 3019 02/15/12 KAR-040-02-01 ASTM D 4479 02/15/12 KAR-041-02-01 ASTM D 4479 02/15/12 KAR=042-02-01 ASTM D 1227 02/15/12 KAR-046-02-01 ASTM D 1227 02/15/12 KAR-048-02-01 ASTM D 1227 02/15/12 KAR-049-02-01 ASTM D 3019 02/15/12 KAR-050-02-01 ASTM D 3019 02/15/12 KAR-051-02-01 ASTM D 3019 02/15/12 KAR-052-02-01 ASTM D 3019 02/15/12 KAR-055-02-01 ASTM D 2824 04/18/12 KAR-057-02-01 ASTM D 4479 05/02/12 KAR-058-02-01 ASTM D 4586 05/02/12 KAR-070-02-01 ASTM D 4479 05/28/13 KAR-072-02=01 ASTM D 41 05/28/13 KAR-073-02-01 ASTM D 2824 08/08/13 KAR-076-02-01 ASTM D 5895 11/06/13 KAR-077-02-01 ASTM D 2824 08/21/14 512T0002 ASTM D 1227 01/09/20 512T0003 ASTM D 1227 01/09/20 MANUFACTURING LOCATIONS: 1. Clark, NJ 2. Ft. Lauderdale, FL 3. Wickliffe, OH NOA No.: 21-0706.03 MIAMI-DADE COUNTY Expiration Date: 09/13/26 " • Approval Date: 09/02/21 Page 2 of 9 INSTALLATION: Karnak Roof Cements and Coating shall be applied in accordance with manufacturer's Product Data Sheet. For use in roof system approvals, refer to the specific Roofing System's, Product Control Notice of Acceptance for the proper application specifications. PHYSICAL PROPERTIES OF COMPONENTS Tradename: (916 AF) Double Coverage Cement Application Rate: This material is applied by brush, broom or squeegee at an approximate rate of 2 to 3 gal./sq.ft. Specifications: ASTM D 3019 type III Description: An asbestos free blend of selected asphalts, mineral fillers and refined solvents. For use as lap cement, rolled adhesive, blind nailing cement slab insulation adhesive. Container size: 1, 5, 55, and 275 gallons. Note all precautions on, container. Manufacturing Location #2 Tradename: (#18 AF) Perfect Seal and (#13) Plastic Cement Application Rate: This material is applied by trowel and spread to an average thickness of 1/8", approximately 8 gal./sq. Specifications: ASTM D 4586 type I Description: A general purpose plastic cement for repairing leaks in shingles, concrete, metal or asphalt roofs. Container Size: 1, 3, 5 gallons and 10.3 oz. tube. Notice all precautions on container. Manufacturing Location #2 Tradename: (#19 AF) Flashing Cement Application Rate: This material is applied by trowel spread to an average thicknes of 1/8", approximately 8 gal./sq. Specifications: ASTM D D 4586 type I Description: An asbestos free, general purpose flashing cement for repairing leaks in shingles, concrete, metal or aspahlt roofs. Container Size: 1, 3, 5 gallons and 10.3 oz. tube. Notice all precautions on container. Manufacturing Location #2 Tradename: (#19 Ultra) Flashing Cement Appplication Rate: This material is applied by trowel to an average thickness of 1/8", approximately 8 gal./sq.ft. Specifications: ASTM D 4586 type I Description: Rubber reinforced asbesto-free, wet/dry flashing cement for repairing of leaks in shingles, concrete, metal or asphalt roofs, flashings on walls, chimneys, flues skylight flashings, downspouts and cornices. Container Sizes: 1, 3, 5 gallons and 10.3 oz. tube. Notice all precautions on container. Manufacturing Location #2 NOA No.: 21-0706.03 MIAMI•DADE COUNTY Expiration Date: 09/13/26 Approval Date: 09/02/21 Page 3 of 9 Tradename: (#66) & (#29 Perfectseal) Modified Bitumen Adhesive (Brush and Trowel) Application Rate: This material is applied by squeegee, roller, brush or trowel at a rate of 1 gal./100 sq.ft. On porous or irregular surfaces consult manufacturer for application rates, Specifictions: ASTM D 3019 type III and ASTM D 3409 Description: A cold applied, SBS polymer modified asphalt ashesive. Used to make repairs on existing modified application and flashing on vertical surfaces and to adhere SBS modified bitumen membranes. Container Size: 5, 55 gallons. Note all precautions on container. Manufacturing Location #2 Tradename: (#71 AF) Fibrated hoof Coating Application Rate: This material is applied by brush, broom or squeegee at an approximate rate of 4 gal./sq.ft. Specifictions: ASTM D 4479 type I Description: An asbestos free, fibrated, roof coating consisting of selected asphalts, mineral fibers and mineral spirits. Container Size: 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location #2 Tradename: (#78 AF) Cold Process Cement Application Rate: Applied by brush at a rate of 2 gal./100sq.ft. Specifictions: ASTM D 3019 type III and D 4479 type I Description: An asbestos free, multi -purpose asphalt cement. For use as a nail or lap cement with prepared rolled roofing. Container Size: 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location #2 Tradename: (#81 AF) Modified Bitumen Adhesive (Brush Grade) Application Rate: This material is applied by brush at an approximate rate of 1 gal./100sq.ft. On porous or irregular surfaces, consult manufacturer for application rates. Specifictions: ASTM D3019 type III Description: A cold applied, SBS polymer modified asphalt adhesive. Used to adhere SBS modified bitumen membranes, base and ply sheets, BUR ply sheets or fully granulated cap sheets. Container Size: 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location 92 NOA No.: 21-0706.03 MIAMI•DADE COUNTY Expiration Date: 09/13/26 F-11NU1011411 Approval Date: 09/02/21 Page 4 of 9 Tradename: (#81 AF) Modified Bitumen Adhesive (Trowel .Grade) Application Rate: This material is applied by trowel at an approximate rate of 1 galJ100sgJ1. On porous or irregular surfaces, consult manufacturer for application rates. . Specifictions: ASTM D3019 type III Description: A cold applied, SBS polymer modified asphalt adhesive. Used to make repairs on existing modified applications and flashings on vertical surfaces. Container Size: 5 gallons and 10.3 oz. tube. Note all precautions on container. Manufacturing Location #2 Tradename: (#83 AF) Fibrated Dampproofing Application Rate: This material is applied by brush, spray or roller at an approximate rate of 4 gal./100sq.ft. Specifictions: ASTM D 4479 Type I Description: An asbestos free, cold applied, multi -purpose, dampproofing compound designed to dampproof masonry and concrete exterior surfaces below grade and interior surfaces above grade. Container Size: 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location #2 Tradename: (#86 AF) Fibrated Trowel Mastic Application Rate: Applied with a trowel at an approximate rate of 5 to 6.ga1./100sq.ft. Specifictions: ASTM D 4586 type I Description: A protective coating for exterior masonry walls below grade. For use as a dampproofmg for retaining walls, bridge abutments and steel panels. Also used for coating of interior faces of exterior masonry walls above grade, and stone, brick or concrete. For use as a waterproofing when used in a multi -membrane application. Container Size: 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location #2 Tradename: (#89) Sta-Tack Primer Application Rate: Applied by brush, roller or hand sprayer at a rate of 1 gallon per 500 square feet. Specifictions: ASTM D 41 Description: A waterbased polymer modified primer for self -adhering membranes. Suitable for use over asphalt, wood, plywood, gypsum board and concrete surfaces Container Size: 1 and 5 gallon pails. Manufacturing Location #1 NOA No.: 21-0706.03 Expiration Date: 09/13/26 Approval Date: 09/02/21 Page 5 of 9 Tradename: (#97 AF) & (Perfectseal #27 AF). Fibrated Aluminum Roof Coating Application Rate: Applied by brush, squeegee, roller or spray at an approximate rate of 1 to 1 %z gal/100sq. ft. Specifictions: ASTM D 2824 Type III Description: An asbestos free fibrated aluminum roof coating consisting.of asphalts, pigment flakes of aluminum, solvents and reinforcing fibers. For use on modified bitumen membranes, metal corrugated decks and steep asphalt which has aged for 90 days. Container Size: 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location #1 Tradename: (#98AF) Fibrated Aluminum Roof Coating Application Rate: Applied by brush, roller or spray at an approximate rate of 1 to 1 %z gal/100sq. ft. Specifictions: ASTM D 2824 Type .III Description: An asbestos free fibrated aluminum roof coating consisting of asphalts, pigment flakes of aluminum, solvents and reinforcing ..fibers. For use on modified bitumen membranes, metal corrugated decksand steep asphalt which has aged for 180 days. Container Size: 5 and 55gallons. Note all precautions on container. Manufacturing Location #1 Tradename: (#100) Non-Fibrated Emulsion Application Rate: Applied by brush, roller or spray at an approximate rate of 2 to 3 gal/100sq. ft. Specifictions: ASTM D 1227 type III, Class I Description: A general purpose non-fibrated emulsion roof coating. Container Size: 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location #1 and #3 Tradename: (#108) Primer & (#112) Foundation & Roof Coating Application Rate: Applied by brush or spray at an approximate rate of 1 to 2 gal/100sq. ft. Specifictions: ASTM D-41 Description: A general purpose asphalt primer. For use in the preperation of all types of surfaces previous to the application of hot or cold asphalt coatings. Used to coat all types of flat asphalt roof surfaces and to dampproof concrete, concrete block and masonary surfaces. Container Size: 5, 55 and 275 gallons and 14 oz. spray can. Notice all precautions on container. Manufacturing Location #1 NOA No.: 11-0706.03 MIAMI•DADE COUNTYM Expiration Date: 09/13/26 Approval Date: 09/02/21 Page 6 of 9 Tradename: (#155 AF) Amphibikote Application Rate: Applied by trowel to an average thickness of 1/8", approximately 8 gaU100sq. ft. Specifictions: ASTM D 4586 type I Description: Asbestos free, cold process, trowel applied emergency roof cement. For use in repairing leaks in asphalt and built-up roofs, flashing on walls, chimneys, skylights and vents, down -spouts and gutters. Container Size: 5 gallons and 10.3 oz. tube. Notice all precautions on container. Manufacturing Location #2 Tradename: (#169) & (Perfectseal #28 NF) Non-Fibrated Aluminum Coating Application Rate: Applied by brush, roller or spray at an approximate rate of 1 gal/200sq. ft. Specifictions: ASTM D 2824 type I Description: A non-fibrated aluminum roof coating consisting of asphalt, solvents and fine aluminum flakes. Container Size: 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location #1 Tradename: (#198 AF) Asphalt Resaturant Application Rate: Apply by brush or spray at an approximate rate of 7 to 8 gaU100sq. ft. Specifictions: ASTM D 4479 type I Description: A blend of asphalt, mineral fillers and penetrating oils. Container Size: 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location #1 Tradename: (#220 AF) Fibered Emulsion Application Rate: Apply by brush or spray at an approximate rate of 4 gaU100sq.ft. Specifictions: ASTM D 1227 type II Class I Description: An asbestos free emulsion roof coating manufactured with refined asphalt, bentonite clay, emulsifiersand fibers. Container Size: 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location #1 and #3 NOA No.: 21-0706.03 MIAMI•DADE COUNTY Expiration Date: 09/13/26 9 91 Approval Date: 09/02/21 Page 7 of 9 Tradename: (#229) AR Elastomeric Trowel Grade Application Rate: Applied by trowel at an approximate rate of 2 to 4 gal/100sq. ft. Specifictions: ASTM D 4586 Description: 'An SBS rubber reinforced asphalt which forms an elastomeric roof coating. For use as a flashing, edging, expansion joints, pitch pockets and other areas where extreme movement is anticipated. Container Size: 3, 5, and 55 gallons. Note all precautions on container. Manufacturing Location #1 Tradename: #229) rAt ElastomericBrush Grde A 'phcah-�Rater----� pplied by brush, spray, squeegee or roller at an approximate rate of 2 to 4 gal/100sq. ft._ Specifictions ASTM D 4479 type I An SBS rubber reinforced asphalt which forms an elastomeric roof coating. For use as a roof coating on BUR, metal or granulated roofing. Container Size: 3, 5, 55, and 275 gallons. Note all precautions on container. Manufacturing Location #1 Tradename: (#920) Fibrated Emulsions Mastic Application Rate: Applied by trowel at an approximate rate of 4 to 6 gal/100sq. ft. Specifictions: ASTM D 1227 type IV Description: A protective coating manufactured with refined asphalt, emulsifiers, non -asbestos fibers and organic clay fillers. For use against dampness on interior above grade, and exterior surfaces of concrete, metal and wood above or below grade. Container Size: 5, 55 gallons. Note all precautions on container. Manufacturing Location #1 Tradename: (#15) MUCK Application Rate: This material is applied by trowel and spread to an average thickness of 1/8", approximately 8 gal/sq. Specifictions: ASTM D 4586 type I Description: A general purpose flashing cement for repairing in shingles, concrete, metal or asphalt roofs. Container Size: 3, 5 gallons. Note all precautions on container. Manufacturing Location #2 NOA No.: 21-0706.03 MIAMI-DADE COUNTY Expiration Date: 09/13/26 Approval Date: 09/02/21 Page 8 of 9 LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this products. 2. Karnak Coatings and Cements shall not be applied in inclement weather conditions. 3. The products listed Herein are components of roof assemblies and are approved for use with roof assemblies that list the products. listed herein as part of their Roof Assembly Notice of . Acceptance. 4. All products listed herein shall, have an unannounced follow-up quality control program from an approved listing agency. Follow up test result shall be made available to Miami -Dade Product Control upon request. 5. Change in materials, use or manufacture of any of the products listed herein shall be cause for termination of this Notice of Acceptance. 6. These roof coatings -shall not be applied over, prepared roofing; i.e., fibercement shingles, quarry slate, cement or clay roof tile, metal shingles, wood shingles or shakes. 7. Karnak Roof Cements and Coatings shall be used as components within approved roofing systems in accordance with applicable building code. Karnak Coatings and Cements are not approved to be used as repair or recover roof systems. 8. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade :County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. 9. All products listed herein shall have an unannounced follow-up quality control program from an approved listing agency, and shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61620-3 of the Florida Administrative Code. Follow up test results shall be made available to Miami -Dade Product Control upon request. MIAMI•DADE COUNTY END OF THIS ACCEPTANCE NOA No.: 21-0706.03 MIAMI•DADE COUNTY Expiration Date: 09/13/26 " • Approval Date: 09/02/21 Page 9 of 9 n i Lot N ? t�, �• Ig �tn jrPjfi •1 C n r� 0 C \ 2. w r� 'CAFE' etsco �.O V Q r t ����© ��'sikJ1 1 a i-r i _ 13.I;�—i�CC19t o n 1JCni olnvi 3 t(b c S z) , 7 L.S?o c o Ar E: p �` _ r �•�iYr.,e-ft t ! < �;1 ` i '!:I\.Ji_ ���_l.l �`� ;C r0+1 Y 0 }, YI } ' — — ' i`f✓ .. i. '• ..t 'vf:eirr: y�Mre •L^et�. +t: s2♦ iw ] 7±�_,llll�!,1:;ir l-��.1-�- IO I� C C 0 f 1 .� y r� I i i�IZ )A.1�s3Lfal JiFli�tr111 ''�i?Otid©i'�:f"•q rr System Deck l�`BoTL'T_a LW C(Note14)trj_5rito�" 1 No. (Note 1) Temp Roof / vB Roof Cover (Note 15)' Type Surface Treatment Primer Base MDP :ELCORE(NOA18-0717.05): Ply Cap LWC-135. Structural Note 19 Celcore MF Cellular Concrete with Celcore FIS Rheology Celcore PVA (Optional)AS M Concrete Modifying P Ifyin Admixture, Min. 300 psi, or Celcore Cellular Concrete, Min. 380 psi, min. 2-inch Curing D41, ELASTOCOL SBS-CA2, 12-inch (Optional) SBS-CA4, SBS-CA3, SBS-CA4, SBS-AA, thicic. Compound 500, ELASTOCOL SBS-SA1 or SBS-AA, SBS-SA1 or -60.0 LWC-136. Structural None Celcore MF Cellular Concrete with Celcore Stick O.C. SBS-TAF SBS-TAF Concrete HS Rheology Modifying Admixture, Min. 330 psi, min. 2-inch thick Celcore PVA None SOS-CA2, (Optional) SBS-CA3, ( 'Structural r Concrelw' 5D5•TAF (sanded top Celcore Curing Compound 6-Inch o.c. SBS-CA4, SBS-AA or SBS-CA3, SBS-CA4, SBS TAF SBS-AA or SBS TAF -180.0 "(primed) surface) - MF Ce)lutaz; Concrete rvtlli Celcore H5 ftliaDlogY I Mfldtfying-Admixture M1n.330,psi, [ekore PVA SflS SA2 i _ ' (D�p9ma1)SD3 CA3- LWC-138. Structural None min.2 irtch.thicli Celcore MF Cellular Concrete Curin� CornpDurid - `„ 'PJooe Branch ¢c. SBS CA4-S85-AA o � SDS-CA4, 1$ � Concrete with Celcore HS Rheology gy Celcore PVA SAyTAF-y ;5BS-AA or SOS- AF Structural Modifying Admixture, Min. 330 psi, min. 2-inch thick Curing Compound None SBS-CA3 SBS-CA4 LWC-139. Concrete SBS-TAF (sanded top Celcore MF Cellular Concrete with Celcore HS Rheology(Optional) SBS-CA4 :382.S (primed) surface) Modifying Admixture, Min. 330 psi, min. 2-inch thicic Celcore PVA None LWC-140. Structural None Celcore MF Cellular Concrete with Celcore Curing Compound SBS-CA3 (Optional) SBS-CA4 ( P ) SBS-CA4 -382.5 Concrete Structural HS Rheology ModifyingAdmixture, Min. 330 psi, min. 2-inch thicic Celcore PVA Curing Compound None SBS-CA3 (Optional) S85-CA3, S85-CA3, SBS-AA or LWC-141. Concrete SBS-TAF (sanded top surface) Celcore MF Cellular Concrete with Celcore IiS Rheology Celcore SBS-AA orS85-TAF 585 TAF -445.0 CONCRECEL(NOA18-0207.03): (primed) Modifying Admixture, Min. 330 psi, min. 2-inch thick PVA Curing Compound None SBS-CA3 (Optional) 585-CA3, SBS-CA3, SBS-AA or SBS-AAorSBS-TAF SBSTAF •445.0 Structural (Optional) Asphaltic LWC-142: plies with asphalt Concrecel Bonding Agent followed by Concrecel Concrete Concrete, Min. 300 sr min. 2-inch thicic flood coat Psi, LWC-143. I structural concrete None ELASTIZELL (NOA 18-n2na_nai. LWC-144. Structural Concrete Note 19 PRE-EXISTENT CELLULAR LWC (NOTE 1A \IEMO ETC, LLC =ertificate of Authorization H324.55 CD2019 MEMO ETC, LLC Concrecel Concrete, Min.340 psi, min. 2-inch thick Elastizell, Min. 300 psi, min. 2-inch thick. (Optional) ASTM Concrecel Curing D41, ELASTOCOL SBS-CA2, (Optional) SBS-CA4, SBS-CA3, SBS-CA4, Comp 500, ELASTOCOL 12-inch SBS-AA, SBS-SA1 or SBS-AA, SBS-SAI or -60.0 Stick O.C. SBS-TAF SBS-TAF None None (Optional) SBS-CA3, SBS-CA3 SBS-CA4, SBS-AA or SBS-CA3, SBS-CA4, SBS-TAF SBS-AAor58S-TAF -127.5 (Optional) ASTM None D41, ELASTOCOL SBS-CA2, (Optional) SBS-CA4, S13S-CA3, SBS-CA4, 500, ELASTOCOL 12-inch SBS-AA, SBS-SA2 or SBS-AA, SBS-SA1 or -G0.0 Stick O.C.SBS-TAF SBS-TAF 7" EDITION (2020) FBC HVHZ EVALUATION Soprema Modified Bitumen Roof Systems; (800) 356-3S21 Evaluation Report 15920.09.17-118 for FL23301-RS Revision 8: 12/15/2021 Appendix 1, Page 121 of 148 1/13/22, 8:28 AM TGFU.R11436 -Roofing Systems I UL Product iQ I GFU.R11436 - Roofing Systems (Vote: We are enhancing our systems and you may notice duplicate entries/missing/outdated data. During this interim period, please contact our Customer Service at httPA.&www.ul.cam %about/locations. Roofing Systems SOPREMA UNC R11436 310 QUADRAL DR WADSWORTH, OH 44281-9571 United States Any roof covering system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification. Uniform thickness or tapered insulation may be used in the following systems provided they do not exceed the indicated incline or thickness. "Sopra-ISO" insulation may be used wherever polyisocyanurate insulation is specified. Unless otherwise.indicated, "Sopra-ISO r", "Sopra-ISO r Tapered", "Sopra=ISO+ r", "Sopra-ISO+ r Tapered", "Sopra-ISO F r", "Sopra-ISO F r Tapered", "Sopra-ISO H r", "Sopra-ISO H+ r", "Sopra-ISO Premier+ r", "Sopra-I50 FB r", "Sopra-ISO FS r Tapered", "Sopra-ISO B r", maybe substituted for polyisocyanurate in any of the systems listed below. "Sopra-ISO r" or "Sopra-ISO r Tapered", may be perforated on one side for use as the contact side for BUR or modified bitumen membrane. "Sopra-ISO H r" may be used over any polyisocyanurate insulation product in any of the following Classifications. "Sopra-ISO FB r", "Sopra-ISO FB r Tapered", may be substituted for "Sopra-ISO r". "Sopra-ISO+ r" may be substituted for "Sopra-ISO r" polyisocyanurate insulation in any of the following Classifications. "Sopra-ISO H s" or Atlas "ACFoam HS Cover Board" may be used over polyisocyanurate insulation product in any of the following Classifications. "Sopra-ISO H r" or Hunter "H-Shield HD" (minimum 1/2 in. thick) or "Sopra-ISO H+ r" or Hunter "HShield HD Composite CG" may be used over any UL Classified polyisocyanurate or polystyrene on non-combustible roof decks. Maximum incline shall be in accordance with the Classification established for the insulation/membrane roof covering system, but cannot exceed 2:12. Unless otherwise indicated, the insulation and barrier board adhesives designated "Duotacic", "Duotacic 365", "Duotacic Neo" and "DUOTACK SPF" may be used to adhere insulation or barrier boards to the roof deck, to adhere insulation and barrier boards together or to adhere layers of insulation together, in any roof covering system Classification. "Sopra 4897" is an acceptable alternate to Type G1, Type G2 and "Sopra G" in all applicable Classifications. Unless otherwise specified, minimum insulation thickness shall be: 1. 1.0 in. for "Sopra-ISO Tapered x" 2. 1.3 in. for "Sopra-ISO + x" "Ultra -Max Plus" may be used in lieu of "Sopra-ISO + x" and "Tapered Ultra -Max Plus" may be used in lieu of " Sopra-ISO + Tapered x". National Gypsum Co. "DEXcell Glass Mat Roof Board" or "DEXcell FA Glass Mat Roof Board" may be used in any UL Classified roof covering system assembly that incorporates the use of minimum 1/4-in. thick Georgia-Pacifc Gypsum LLC "DensDecic® Roofboard" or "DensDecic Prime@ Roofboard" or "DensDecic DuraGuardTM' Roofboard" or United States Gypsum Co. SecuRockO Glass -Mat Roof Board. References to "SENTINEL PI SO and "SENTINEL P200" include 50 mil and 60 mil product, unless otherwise noted. https://Iq.ulpr6spector.com/en/profile?e=148925 11120 1/13/22, 8:28 AM TGFU.R11436 - Roofing Systems i UL Product iQ Georgia-Pacific Gypsum LLC "DensDecic Prime @S T ORMX.TmRoofboard" may be used as an alternate to Georgia-Pacific Gypsum LLC'DensDeck Prime® Roofboard" in all applicable Classifications. 3/4 (20-mm) to 2-1/4 in. (60-mm) thick "Kingspan Optim RI Vacuum Insulation Panel (VIP)" adhered with any UL Classified insulation adhesive may be used under a Barrier Board in all'applicable Classifications when minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDecic 0 Roofboard" or "DensDecic Prime® Roofboard" or "DensDecic Prime 2Tm Roofboard" or "DensDecic DuraGuard® Roofboard" or "DensDecic Prime® STORM)('' Roofboard" or United States Gypsum Co. SECUROCI(® Glass -Mat Roof Board (Type SGMR)Q" or (National Gypsum Co. "DEXcell Glass Mat Roof Board" or "DEXcell FA Glass Mat Roof Board" is used as a Barrier Board. DETEC SYSTEMS LLC. "TruGround1m Conductive Primer", applied at 1/3 gal/100 ftz may be used as an alternate to "Elastocol 500", "Elastocol 600c", "Elastocol Stick H2O", "Elastocol Stick WB Primer", "Alsan RS 222 Primer" and "Alsan RS 276 Primer" in all applicable Classifications. For Combustible (Roof Decks - Class A: 1. A minimum 3-in. thick layer or a minimum two layers of 1.5-in. thick " Sopra-ISO+ r" or "Sopra-ISO H+ r" is placed directly over a combustible roof deck and is covered with any UL Classified roof covering membrane used in any UL Class A roof covering assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, maybe used below the 3-in. minimum. total thickness of "Sopra-ISO+ r" or "Sopra-ISO H+ r". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the foof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly; however the incline cannot exceed 1/2:12. 2. A minimum 1/2 in. thick layer of "Sopra-ISO H r" over a minimum 2.5-in. thick layer of any Soprema. Inc Classified polyisocyanurate insulation is placed directly over a combustible roof deck and is covered with any UL Classified roof covering membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 3-in. minimum total thickness. The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the roof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 3. A minimum 1-in. thick layer of "Sopra-ISO Premier+ r" is placed directly over a combustible roof deck and is covered with any UL Classified roof covering membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified. insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1-in. minimum thickness of "Sopra-ISO Premier+ r". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used rbelow the insulation. All insulation joints must be staggered a minimum of 6-in. from the roof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membranefinsulation roof covering assembly; however the incline cannot exceed 1/2:12. For Combustible P:oof Decks - class S: 1. A minimum 1.9-in. thick layer of "Sopra-ISO+ r" or "Sopra-ISO H+ r" is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class B roofing assembly to achieve a Class B fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-im minimum thickness layer of Soprema Inc "Sopra-ISO+ r" or "Sopra-ISO H+ r". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6- in. from the roof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 2. A minimum 1/2 in. thick layer of "Sopra-ISO H r" over a minimum of 1.4-in. thick layer of any Soprema Inc Classified polyisocyanurate insulation is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class B roofing assembly to achieve a Class B fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-in. minimum thickness layer. The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 64n. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly; however the incline cannot exceed 1/2:12. Unless otherwise indicated, when referring to gypsum board in the following classifications, the following will be referenced: United States Gypsum Co. "SECUROCK'' Roof Board (type FRX-G)" or "SECUROCK® Glass -Mat Roof Board (Type SGMRX)" or 1/2 or 5/8-in. thick "Type DCB", or minimum 1/4-in. thick Georgia-Pacifc Gypsum LLC "DensDecic© Roofboard" or "DensDecic Prime® Roofboard" or "DensDecic DuraGuard- Roofboard" or "DensDecic Prime 21"'", Regular gypsum board (not Classified) laid with staggeredjoints (6-in. offset) measuring 0.5-in. thick minimum and weighing 184-Ibs/100-ft.2 minimum or Georgia Pacific "Sound Deadening" Board, measuring 0.208-in. thick minimum and weighing 109-Ibs/10o-ft.2 minimum, mechanically fastened with all butt joints staggered a minimum of 6-in. from the insulation and plywood deck joints, hot mopped or adhered with any UL Classified insulation adhesive. hftps:/fiq.ulprospector.com/en/profile7e=148925 21120 1/13/22, 8:28 AM TGFU.R11436 - Rooting Systems I UL Product iQ NOTE: Polystyrene insulation must be covered with minimum 1/4-In. thick Georgia-Pacific Gypsum LLC "DensDecic @ Roofboard" or "DensDecic Prime@ Roofboard" or "DensDecic Prime 21 Roofboard" or "DensDecic DuraGuard@ Roofboard" or Certainteed Gypsum Inc.. "GlasRoc°or United States Gypsum Co. SECUROCK@ Glass -Mat Roof Board (Type SGMR)Q" or National Gypsum Company "DEXcell Glas Mat Roof Board" or DEXcell FA Glas Mat Roof Board". Barrier Board (Optional): — "Sopraboard" (min 1/8 in.), perlite (min 1/2 in.), gypsum or gypsum fiber (min 1/4 in.) or wood fiberboard (min 1/2 in.) mechanically fastened, hot mopped or adhered with any UL Classified insulation adhesive. (Base Sheet (OptionW): — One or more plies Type G1 or Type G2; "Sopra IV", "Sopra VI", "Sopraglass 40", "Sopraglass 100", "Sopra G" or "Modified Sopra G", any combination mechanically fastened or adhered with hot asphalt. Ply Sheet (Optional): — One or more plies "Elastophene Sanded", "Elastophene HD", "Elastophene HR 2.2", "Elastophene HS FR", "Elastophene HP", "Elastophene 180 Sanded", "Sopralene 180 Sanded 2.2", "Sopralene 180 Sanded", "Sopralene 250 Sanded", "Elastophene PS 2.2", "Elastophene 180 PS", "Sopralene 180 PS 2.2", "Sopralene 180 PS 3.0", "Sopralene 250 PS", "Elastophene HS", "Elastophene HS 62"or "Soprabase S" adhered with hot asphalt or mechanically fastened; or "Elastophene Flam", "Elastophene Flam 2.2", "Elastophene Flam HD", "Elastophene Flam HR", "Elastophene Flam HS FR", "Elastophene Flam HP", "Sopralene Flam 180", "Sopralene Flam 250", "Elastophene Flam HS," "Elastophene Flam HS HD," "Colvent TG" or "Soprabase TG" heat welded or mechanically fastened; or "Soprafix", "Soprafix)(" or "Soprafix E" mechanically fastened; or "ELASTOPHENE Stick", "ELASTOPHENE Flam Stick", "ELASTOPHENE SURE -STICK", "ELASTOPHENE ULTRA -STICK", "SOPRALENE ULTRA -STICK", "SOPRALENE Stick", "SOPRALENE Flam Stick", "SOPRALENE SURE -STICK", "Colvent SA" or "EPS Flam Stick self -adhered; or "Soprasmart Board", "Soprasmart Board 180", "Soprasmart ISO HD", "Soprasmart ISO HD 180", "Soprasmart Board Sanded", "Soprasmart Board 180 Sanded", "Soprasmart ISO HD Sanded", or "Soprasmart ISO HD 180 Sanded" adhered with "Duotacic" or "Duotacic 365" adhesive or hot asphalt or mechanically fastened. Cap Sheet: — "Elastophene FR GR", "Elastophene HD FR GR", "Elastophene HR FR GR", "Elastophene HS FR GR", "Elastophene HP FR GR", "Elastophene LS FR GR", "Sopralene 180 FR GR", "Sopralene 180 FR GR 3.5" or "Sopralene 250 FR GR" adhered with hot asphalt, or "Elastophene Flam FR GR", "Elastophene Flam HD FR GR", "Elastophene Flam HR FR GR", "Elastophene Flam HS FR GR", "Elastophene Flam HP FR GR", "Elastophene Flam LS FR GR", "Sopralene Flam 180 FR GR", "Sopralene Flam 180 FR GR 3.5" or "Sopralene Flam 250 FR GR" heat welded; or "Colphene FR GR", "Elastophene Stick FR GR", "ELASTOPHENE SURE -STICK FR GR" or "ELASTOPHENE ULTRA -STICK FR GR", self -adhered. 89. Deck: NC Incline: 1 Primer (Optional): —AQUAFIN "VAPORTIGHT COAT-SG3" (not UL Classified), applied at 1 gal/100 ft2. Thermal Carrier (Optional): — Gypsum or gypsum fiber (min 1/4 in.), perlite or mineral wool (min 3/4 in.), cement board (min 1/4- in.) or wood fiberboard (min 1/2 in.) mechanically fastened or adhered with any UL Classified insulation adhesive. Vaporr Retarder (Optional): — Any UL Classified or Soprema base sheet, ply sheet or Sopravap'r; mechanically -fastened or adhered. Case Sheet (Optional): — One or more plies Type G1 or Type G2; "Sopra IV", "Sopra VI", "Sopraglass 40", "Sopraglass 100", "Sopra G", "Modified Sopra G", or "SURESTICK" Nail Base", any combination mechanically -fastened or adhered with hot asphalt. Insulation (Optional): — Polyisocyanurate, polystyrene (EPS, XPS), glass giber, mineral wool, perlite, wood fiber or cellular glass insulation, any thickness, any combination, mechanically fastened, loose laid or adhered with hot asphalt or insulation adhesive. NOTE: Polystyrene insulation must be covered with minimum 1/4-in. thick Georgia-Pacifc Gypsum LLC "DensDecic @ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDecic Prime 21 Roofboard" or "DensDecic DuraGuard0 Roofboard" or Certainteed Gypsum Inc. "GlasRoc" or United States Gypsum Co. SECUROCKO Glass -Mat Roof Board (type SGMR)Q". Carrier Carol (Optional): — "Sopraboard" (min 1/8 in.), perlite (min 1/2 in.), gypsum or gypsum fiber (min 1/4 in.) or wood fiberboard (min 1/2 in.) mechanically fastened, hot mopped or adhered with any UL Classified insulation adhesive. Case Sheet (Optional): — One or more plies Type G1 or Type G2, "Sopra IV", "Sopra VI", "Sopraglass 40", "Sopraglass 100", "Sopra G" or "Modified Sopra G", any combination mechanically fastened or adhered with hot asphalt. Ply Sheet (Optional): — One or more plies "Elastophene Sanded", "Elastophene HD", "Elastophene HR 2.2", "Elastophene HS FR", "Elastophene HP", "Elastophene 180 Sanded", "Sopralene 180 Sanded 2.2% "Sopralene 180 Sanded", "Elastophene PS 2.2", "Elastophene 180 PS", "Sopralene 180 PS 2.2", "Sopralene 180 PS 3.0", "Sopralene 250 PS", "Elastophene HS", "Elastophene HS 62" or "Soprabase S" adhered with hot asphalt or mechanically fastened; or "Elastophene Flam", "Elastophene Flam 2.2", "Elastophene Flam HD", "Elastophene Flam HR", "Elastophene Flam HS FR", "Elastophene Flam HP", "Sopralene Flam 180", "Elastophene Flam HS", "Elastophene Flam HS HD", "Colvent TG" or "Soprabase TG" heat welded or mechanically fastened; or "Soprafix", "Soprafix X" or "Soprafix E" mechanically fastened; or "ELASTOPHENE Stick", "ELASTOPHENE Flam Stick", "ELASTOPHENE SURE -STICK', "ELASTOPHENE ULTRA -STICK", SOPRALENE ULTRA -STICK", "SOPRALENE Stick", "SOPRALENE Flam Stick", "SOPRALENE SURE -STICK', "Colvent SA" or "EPS Flam Stick self -adhered; or "Soprasmart Board", "Soprasmart Board 180", "Soprasmart ISO HD", "Soprasmart ISO HD 180", "Soprasmart Board Sanded", "Soprasmart Board 180 Sanded", "Soprasmart ISO HD Sanded", or "Soprasmart ISO HD 180 Sanded" adhered with "Duotacic" or "Duotack 365" adhesive or hot asphalt or mechanically fastened. Cale Sheet: — "Sopralene 180 FR GR", "Sopralene 180 FR GR 3.5" or "Sopralene 250 FR GR" adhered with hot asphalt; or "Sopralene Flam 180 FR GR", "Sopralene Flam 180 FR GR 3.5 or "Sopralene Flam 250 FR GR" heat welded; or Unilay FR mechanically fastened. hfps:/riq.ulprospector.com/en/profile?e=148925 65/120 3/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ UL Product iQTM TGFU.R12199 - Roofing Systems Note: We are enhancing our systems and you may notice duplicate entries/missing/outdated data. During this interim period, please refer to the Certificate of Compliance or contact our Customer Service athttps://www.uLcom/about/locations. Roofing Systems See General Information for Roofing Systems KARNAK CORP 330 CENTRAL AVE CLARK, NJ 07066-1108 USA " 66 Brush" and "66 Trowel" adhesive may be used as an alternate to the " 16AF", "81 Brush", "81 Trowel" or "78AF" cold process adhesives. "670LS Karna-Sil" and "670HS Karna-Sil Ultra" may incorporate suffix letters after the numeric designation to identify color (i.e. 'DG' for dark grey, TG' for light grey, 'WH' for white). 1. Deck: NC FLUID APPLIED COATING SYSTEMS Class.A Incline: Unlimited Primer: — "No. 96" Primer, applied at 1/2 gal/sq. Sealer/Mat (Optional): — "ElastoBrite-M Seam Sealer", applied 1/8 in. into which polyester mat (1.8 oz/sq yd) is embedded. Base Coat: — "Elasto-Brite 501 EC" at 1 gal/sq. Finish Coat: — "Elasto-Brite 501 EC" at 1 gal/sq. 2. Deck: NC Incline: Unlimited Primer: - "No. 447TD-1" Primer A & B, applied at 125 sq ft/gal. Base Coat: — "No. 401TD-1 Base Coat", applied at 50 sq ft/gal. TopCoat: — "No. 403TD-1 Top Coat", applied at 100 sq ft/gal. Aggregate: — 35-65 mesh silica sand at a rate of 8-10 Ibs/sq back rolled into the wet coating. 3. Deck: NC Incline: Unlimited Primer: — "No. 447TD-1 Primer" A & B, applied at 125 sq ft/gal. Base Coat: — "No. 401TD-1 Base Coat", applied at 50 sq. ft/gal. Intermediate Coat: — "No. 402TD-1 Intermediate Coat", applied at 100 sq. ft/gal. R12199 https://iq.ulprospector.com/en/profile?e=148945 1/13 3/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ Top Coat: — "No. 403TD-1 Top Coat", applied at 100 sq ft/gal. Aggregate: — 20-30 mesh silica sand at a rate of 10-12 Ibs/sq back rolled into the wet coating. 4. Deck: NC Incline: 2 Insulation: — Johns Manville "ENRGY II," any thickness. Ply Sheet: — One or more plies polyester ply sheets embedded into primer. Coating: — "670LS Karna-Sil series applied 2 to 3-gal/100-ft2. SINGLE PLY MEMBRANE SYSTEMS Class A 1. Deck: NC Incline:1/2 Insulation: — Dyplast Products LLC "Pyrox White Line" glass fiber, perlite or wood fiber, any thickness. Membrane: — Any UL Classified hypalon, mechanically fastened. Surfacing: — "670LS Karna-Sil" series applied at 11/2-gal/100-ft2. SINGLE PLY MEMBRANE ROOFING SYSTEMS Unless otherwise indicated, the roof insulation is mechanically fastened or adhered withhot roofing asphalt. The membrane is heat fused in place. 1. Deck: NC Class A - Fully Adhered Incline: 1/4 Insulation: — Glass fiber, perlite, wood fiber, 2 in. max. Base Sheet: — Type 15 or G2. Membrane: — U.S. Intec "Brai 4", "64", "BSP-4" or "Brai SP-4" (modified bitumen). Surfacing: — "97AF or "98AF", 1 to 2 gal/sq. 2. Deck: NC Incline: 1/4 Membrane: — U.S. Intec "Brai 4" or "64" (modified bitumen). Surfacing: — "97AF' or "98AF", 1 to 2 gal/sq. 3. Deck: NC Incline: 1/4 Insulation: — Glass fiber, perlite, wood fiber, 2 in. max. Base Sheet: — Type 15, G2. Membrane: — U.S. Intec "Brai 4", "134", 'Brai SP-4", "BSP-4" (modified bitumen). Surfacing: — "97AF' or "98AF", 1 to 2 gal/sq. 4. Deck: NC Incline: 1/2. Insulation: — Glass fiber, perlite, wood fiber, 1-1/2 in. max. Base Sheet: — Type G2. Membrane: — Nord Bitumi US "Nord Poly 46" or "Nord Poly 56" (modified bitumen). Surfacing: — "97AF' or "98AF', 1 to 2 gal/sq. https:/riq.ulprospector.com/en/profile?e=148945 2/13 3/10/2021 5. Deck: NC Insulation: — Glass fiber, perlite, wood fiber, 1-112 in. max. Base Sheet: — Type G2. Membrane: — Nord Bitumi US "Nordflex S" (modified bitumen). Surfacing: — "97AF" or "98AF", at 1 to 2 gal/sq. 6. Deck: NC TGFU.R12199 - Roofing Systems I UL Product iQ Incline: 1/4 Incline:1 Insulation: — Polyisocyanurate, urethane, glass fiber, perlite, wood fiber, 6 in. max. Base Sheet: — Type G3 (inverted). Membrane: — Firestone Building Products "APP-160", "APP-170" or "Monoply Plus" (modified bitumen). Surfacing: — "169", "97AF" or "98AF", 1 gal/sq and optional roofing gravel at 400 Ib/sq (loosely laid). 7. Deck: NC Incline: 1 Insulation: — Po lyisocya nu rate, urethane, glass fiber, perlite, wood fiber, 6 in. max. Base Sheet (Optional): — Type G1, G2, G3. Membrane: — Firestone Building Products "APP-160",."APP-170" or "Monoply Plus" (one or more layers - modified bitumen). Surfacing: — "169 " or " 97AF" or "98AF"., at 1 gal/sq. 8. Deck: NC Incline: 1/2 Insulation: — Polyisocyanurate, urethane, glass fiber, perlite, wood fiber, 4 in. max. Base Sheet: — Type G1, G2, one or more layers. Membrane: — Performance Building Products "Derbigum" (modified bitumen). Surfacing: — "97AF" or "98AF", at 1-1/2 gal/sq. 9. Deleted. 10. Deck: NC Incline: 1/4 Insulation: —1-1/2 to 2-1/2 in. polyisocyanu rate insulation board. Ply Sheets: — Three layers Type G1 Tamko Asphalt Products "Tam Ply IV" hot mopped. Membrane: — One layer Tamko Asphalt Products "Awaplan Smooth" (modified bitumen), hot mopped or heat fused. Surfacing: "97AF" or "98AF", at 1-1/2 gal/sq. 11. Deck: NC Incline: 1 Insulation: — Polyisocyanurate, polyisocyanurate/perlite, phenolic or urethane, any thickness, hot mopped or mechanically fastened in place. Ply Sheet: — Three or more layers Type G1 or G2 hot mopped in place. Surfacing: — "97AF" or "98AF", at 1-1/2 gal/sq. 12. Deck: NC Incline: 3 Insulation: — Glass fiber, perlite, wood fiber, any thickness, hot mopped in place. Ply Sheet: — Three or more layers Type G1 or G2 hot mopped in place. Surfacing: — "220 AF Fibered Asphalt Emulsion", applied at 3 gal/sq. 13. Deck: NC Incline: 1/4 https://iq.ulprospector.com/en/profile?e=148945 3/13 3/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ Base Sheet: — One or more layers of the following: "Tam -Ply IV", Type G2 "Glass -Base", "Vent -Ply" or "Tam -Glass Premium", hot mopped or adhered with "81 Brush" and "81 Trowel", applied at 1-1/2 gal/sq or "Vapor -Chan" venting base sheet, spot attached. Base Sheet (Optional): — Type 15 asphalt organic felt or "43 lb Base", hot mopped. Membrane: — "Awaplan, granule surface - regular" (modified bitumen), hot mopped or "Awaplan, granule surface - heat welded" (modified bitumen), heat fused or adhered with "81 Brush" and "81 Trowel", applied at 1-1/2 gal/sq. Surfacing: — "97AF" or "98AF", at 1-1/2 gal sq or gravel. 14. Deck: NC Incline: 2 Insulation: — Polyisocyanurate, glass fiber or wood fiber, any thickness. Membrane: — Any UL Classified APP smooth or granule surfaced membrane. Base Coat: — "220AF Fibered Asphalt Emulsion", 2 gal/sq. Top Coat: — "97AF" or "98AF", at 1-1/2 gal sq. 15. Deck: NC Incline: 2 Insulation: — Polyisocyanurate, glass fiber or wood fiber, any thickness. Base Sheet: — One or more layers Type G1 or G2, hot mopped or mechanically fastened. Base Coat:— "220AF Fibered Asphalt Emulsion", 2 gal/sq. Top Coat: — "97AF" or "98AF", at 1-1/2 gal. sq. 16. Deck: NC Incline: 1/4 Insulation: — Polyisocyanurate, glass fiber, wood fiber or perlite, any thickness, mechanically fastened. Base Sheet: — One or more layers Type G1 or G2, hot mopped in place. Membrane: — Firestone Building Products "APP 160", "APP170" or "Monoply Plus", heat fused. Surfacing: — , 98-AF(s ^'a't�1t1F/r2 • aI;sq 17. Deck: NC Incline: 3/4 Insulation: — Polyisocyanurate, glass fiber, wood fiber or perlite, any thickness, mechanically fastened . Base Sheet:— One or more layers Type G1 or G2, hot mopped in place. Membrane: — GAF "Ruberoid 20" covered with "Ruberoid 30", hot mopped in place. Surfacing: S 18. Deck: NC Incline: 1/4 Insulation: — Polyisocyanurate, glass fiber, wood fiber or perlite; any thickness, mechanically fastened . Base Sheet: — One or more layers Type G1 or G2, hot mopped in place. Membrane: — Any UL Classified SBS or APP modified bitumen membrane, hot mopped or heat fused. Surfacing '298AFg�, a117/C2gal sg Class B - Fully Adhered 1. Deck: C-15/32 Incline: 1/4 Insulation: — Glass fiber, 1-1/2 in. Base Sheet: — Type G2 (Celotex "Vaporbar G-B"). https://iq.ulprospector.com/en/profile?e=148945 4/13 3/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ Membrane: — Nord Bitumi US "Nord Poly 4B" (modified bitumen). Surfacing: — "97AF" or "98AF", at 1 to 2 gal/sq. 2. Deck: C-15/32 Incline: 1/4 Insulation: — Polyisocyanurate, urethane, glass fiber, perlite, wood fiber, 1 in. min, 6 in. max. Base Sheet: — Type G2 (OCF "Perms Ply No. 28") or Manville "No. 28", two layers. Membrane: — Firestone Building Products "APP-160", "APP-170" or "Monoply Plus" (one or more layers). Surfacing: — "97AF" or "98AF", at 1 gal/sq. 3. Deck: C-15/32 Incline: 112 Insulation: — Gypsum board,1/2 in. min, glass fiber, 1-1/2 in. min, plastic coated steel foil, 2 mil. Base Sheet: — Type G1 (Owens-Corning Fiberglas "Perma Ply"). Membrane: — Performance Building Products "Derbigum" (modified bitumen). Surfacing: — "97AF" or "98AF", at 1-112 gal/sq. 4. Deck: C-15/32 Incline: 1/4 Insulation: — Perlite, wood fiber, glass fiber, min 1 in. thick, hot.mopped in place. Base Sheet (Optional): — One or more layers "Glass -Base", hot mopped or adhered with "81 Brush" or "81 Trowel", applied at 1-1/2 gal/sq. Base Sheet: — One or more layers "Versa Base FW, hot mopped in place or adhered with "81 Brush" or "81 Trowel", applied at 1-1/2 gal/sq. Membrane: — "Awaplan Premium FR", "Awaplan 170 FR" or "Versa Cap FR", hot mopped in place or adhered with "81 Brush" or "81 Trowel", applied at 1-112 gal/sq. SPRAY APPLIED FOAM AND COATING SYSTEMS Class A 1 Deck: NC Incline: 3 Foam: — BASF Polyurethane Foam Enterprises LLC "FE 303" any thickness. Base Coat (Optional): — "670LS Karna-Sil" series applied at 11/2-gal/100-ft2. Top Coat: — "670LS Karna-Sil" series applied at 11/2-gal/100-ft2. 2 Deck: NC Incline: 1 Foam: — Coating & Foam Solutions L L C "RT-2716" 2.5 to 3.0-lb/ft3-Ib/ft3, 11/2- to 2-in. thick. Surfacing: — "670LS Karna-Sil" series applied at 21/4-gal/100-ft2. 3 Deck: NC Incline: 3/4 -Foam: — Coating & Foam Solutions L L C "RT-2717," 2.5 to 3.0-lb/ft3-Ib/ft3,11/2- to 2-in. thick. Surfacing: — "670LS Karna-Sil" series applied at 21/4-gal/100-ft2. Any of the following Class A noncombustible roof deck Classifications may be used as Maintenance and Repair Systems when applied over an existing roof covering system and maintain the existing Class A, B or C Classification, providing a minimum 1-1/2 in. thickness of spray applied foamed plastic is utilized. A barrier board consisting of minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeckO Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuarcl ' Roofboard" or United States Gypsum Co. "SECUROCKO Glass -Mat Roof Board (Type SGMRX)" or CertainTeed Gypsum "GlasRoc", mechanically fastened, may used in any existing noncombustible roof deck Classification. When this is done, the resulting roof covering system is acceptable for use over minimum 15/32-in.thick plywood roof decks. The buttjoints in the barrier hftps:/fiq.ulprospector.com/en/profile?e=148945 5/13 31/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ board must be off -set a minimum of 6-in. from buttjoints in the roof deck. The following foam systems are interchangeable with each other in all roofing system: "NRG Foam 340E", "NRG Foam 360E", "NRG Foam 37013" Class A 4. Deck: NC Incline: 1 Foam: —"NRG Foam 340E", "NRG Foam 360E", or "NRG Foam 370E", any thickness Base Coat: — Carlisle Roof Foam and Coatings "Acry-Tek 9000" applied at 1-1/2 gal/100-ft 2. Top Coat: — Carlisle Roof Foam and Coatings "Acry-Tek 9000" applied at 1-1/2 gal/100-ft.2. Surfacing (Optional): — Broadcast application of No.11 ceramic coated granules applied at a rate of 25-Ib/100-ft.2. 5. Deck: NC Incline: 2 Foam: — "NRG Foam 340B", "NRG Foam 360B", or "NRG Foam 370B", any thickness Base Coat: — "670HS Karna-Sil Ultra" applied at 1-1/2 gal/100-ft.2. Top Coat: — "670HS Karna-Sil Ultra" applied at 1-1/2 gal/100-ft 2. Surfacing: — Broadcast application of No.11 ceramic coated granules applied at a rate of 25-Ib/100-ft.2. 6. Deck: NC Incline: 1 Foam: — "NRG Foam 340B", "NRG Foam 360E", or "NRG Foam 370E", any thickness. Surfacing: — Two applications Neogard "Elastocryl 7251" applied at 3-1/2 gal/100-ft2 total. 7. Deck: NC Incline: 1 Foam:— "NRG Foam 340E", "NRG Foam 360B", or "NRG Foam POW% any thickness Surfacing: — BaySystems North America "Caplon" coating applied at 3-gal/100-ft2 8. Deck: NC Incline: 1 Foam: — "NRG Foam 340E", "NRG Foam 360E", or "NRG Foam 370E", any thickness. Base Coat: — BaySystems North America "Evercoat 510" applied at 1-1/2 gal/100-ft2 Surfacing: — BaySystems North America "Evercoat 500," applied at 1-1/2 gal/100-ft2 9. Deck: NC Incline: 1 Foam: — "NRG Foam 340E", "NRG Foam 360B", or "NRG Foam 370B", any thickness. Base Coat: — BaySystems. North America "Evercoat FR521" applied at 1-1/2 gal/100-ft2 Surfacing: — BaySystems North America "Evercoat FR520" applied at 1-1/2 gal/100-ft2 10. Deck: NC Incline: 1 Foam: — "NRG .Foam 340E", "NRG Foam 360B", or "NRG Foam 370E", any thickness. Base Coat: — BaySystems North America "Evercoat 5410" applied at 1-1/2 gal/100-ft2 Surfacing: — BaySystems North America "Evercoat 5400" applied at 1-1/2 gal/100-ft2 11. Deck: NC Incline: I Foam: — "NRG Foam 340E", "NRG Foam 360B", or "NRG Foam 370E", any thickness. https://Iq.61prospector.com/en/profile?e=148945 6/13 3/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ Base Coat: — Conklin Co. Inc. "Polymate" applied at 1-1/2 gal/100-ft2. Surfacing: — Conklin Co. Inc. "Polymate" applied at 1-1/2 gal/100-ft2. 12. Deck: NC Incline: 1 Foam:— "NRG Foam 340E", "NRG Foam 360B", or"NRG Foam 370E", any thickness. Surfacing: — Carlisle Roof Foam and Coatings "Acry-Tek 4200" applied as two applications at 1-1/2 gal/100-ft2/application. 13. Deck: NC Incline: 1 Foam: — "NRG Foam 340B", "NRG Foam 360B", or "NRG Foam 370E", any thickness. Surfacing: — National Coatings Corp. "Acryshield" applied in two or more applications, for a total of 2 to 4-gal/100-ft2. 14. Deck: NC Incline: 1 Foam: — "NRG Foam 340B", "NRG Foam 360B", or "NRG Foam 370B", any thickness. Surfacing: — BASF Corp. "4500 Series" or National Coatings Corp. "Acryshield" applied at 3-gal/100-ft2. 15. Deck: NC Incline: 1 Foam: — "NRG Foam 340E", "NRG Foam 360B", or "NRG Foam 370B", any thickness. Base Coat: — Hydro Seal Coatings "Hydro Seal" applied at 1-1/2 gal/100-ft2. Surfacing: — Hydro Seal Coatings "Hydro Seal" applied at 1-1/2 gal/100-ft2. 16. Deck: NC Incline: 1 Foam: — "NRG Foam 340B", "NRG Foam 360E", or "NRG Foam 370B", any thickness. Base Coat: — GAF "United CoatingsT"' Elastuff@ 101 Base Roof Coating" or BASF Corp. "FE Coat 2000 Series Base Coat" applied at 2=gal/100-ft2/application Surfacing: — BASF Corp. "FE Coat 2000 Series Top Coat" applied at 2-gal/100-ft2/application 17. Deck: NC Incline: 1 Foam: — "NRG Foam 340B "NRG Foam 360E", or "NRG Foam 370E", any thickness. Base Coat: — LaPolla Industries Inc. "TF1000" applied at 1-1/2 gal/100-ft2. Surfacing: — LaPolla Industries Inc. "TF1000" applied at 1-1/2 gal/100-ft2. 18. Deck: NC Incline: 1 Foam: — "NRG Foam 340B", "NRG Foam 360B", or "NRG Foam 370B", any thickness. Surfacing: — "670HS Karna-Sil Ultra" or "670LS Karna-Sil" applied at 2-1/4-gal/100-ft2 19. Deck: NC Incline: 1 Foam: — "NRG Foam 340B", "NRG Foam 360B", or "NRG Foam 370E", any thickness. Surfacing: — Two applications Momentive Performance Materials "SCM 3300 Series" or "BASF Corp. 3-5000" or "BPFE 3-5000" or Dow Corning "3-5000 Construction Coating" applied at 1-1/4-gal/100-ftz/application. 20. Deck: NC Incline: 2-1/2 Foam: — "NRG Foam 340B", "NRG Foam 360B", or "NRG Foam 370B", any thickness. https://iq.ulprospector.com/en/profile?e=148945 7/13 3/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ Surfacing: — Momentive Performance Materials "SCM3400 Series" applied at 3-gal/100-ft2. 21. Deck: NC Incline• 1 Foam: — "NRG Foam 340E", "NRG Foam 360B", or "NRG Foam 370E", any thickness. Surfacing: — Dow Corning Corp. "3-5000 Silicone Roof Coating" at a total of 2-gal/100-ft2, Momentive Performance Materials "SCM-3300" at a total of 3-gal/100-ft2 or Neogard "7850" at a total of 3-gal/100-ft2. 22. Deck: NC Incline: 3 Foam: — "NRG Foam 340E", "NRG Foam 360E", or "NRG Foam 370B", any thickness. Coating: — Momentive Performance Materials "SCM3400 Series" applied at 3-gal/100-ft2. Surfacing: — Broadcast application of No. 11 ceramic coated granules applied at a rate of 30-Ib/100-ft.2. 23. Deck: NC Incline: 3 Foam: "NRG Foam 340B", "NRG Foam 360B", or "NRG Foam 370B", any thickness. Base Coat: — "670HS Karna-Sil Ultra" or "670LS Karna-Sil" applied at 1-1/2 gal/100-ft2. Top Coat: — "670HS Karna-Sil Ultra" or "670LS Karna-Sil" applied at 1-1/2 gal/100-ft2. 24. Deck: NC Incline: 1 Foam: — "NRG Foam 340B", "NRG Foam 360E", or "NRG Foam 370E", any thickness. Base Coat: — Carlisle Roof Foam and Coatings "Acry-Tek 4200" series applied at 1-1/2 gal/100-ft2. Surfacing Carlisle Roof Foam and Coatings "Acry-Tek 4200" series applied at 1-1/2 gal/100-ft2. 25. Deck: NC Incline: 1/2 Foam: — "NRG Foam 340B", "NRG Foam 360E", or "NRG Foam 370B", any thickness. Surfacing: — Carlisle Roof Foam and Coatings "Acry-Tek 9000" applied at 3-gal/100-ft2. 26. Deck: NC Incline: 3 Foam: — "NRG Foam 340E", "NRG Foam 360B", or "NRG Foam 370E", any thickness. Base Coat: — "670HS Karna-Sil Ultra" silicone roof coating applied at 1-1/2 gal/100-ft2. Top Coat: — "670HS Karna-Sil Ultra" silicone roof coating applied at 1-1/2 gal/100-ft2. Surfacing: — Broadcast application of No. 11 ceramic coated roof granules applied at 30-Ib/100-ft2. 27. Deck: C-15/32 Incline: Unlimited Insulation: — (Optional) Any UL Classified polyisocyanurate insulation, any thickness. Foam: — Minimum 1-in. thick "NRG Foam 340B", "NRG Foam 360E", or "NRG Foam 370B". Base Coat: — Carlisle Roof Foam and Coatings "Acry-Tek 4300" or BASF Corp. "ARC Series" or National Coatings Corp.. "Acryshield" applied at 1-1/2 gal/100-ft.2. Top Coat: — Carlisle Roof Foam and Coatings "Acry-Tek 4300" or BASF Corp. "ARC Series" or National Coatings Corp. "Acryshield" at 1-1/2 gal/100-ft.2. Surfacing: — No. 6 crushed limestone at 64-lbs/ 100-ft.2 embedded into wet coating. Followed by a 40-lb mix of dry mix 4-1/2 gal water and 1/2-gal of coating acrylic resin with 3/4-oz. of "Colloid 60" applied at 100-ft.2100-ft.2/batch. 28. Deck: NC Incline:1-112 Foam: — "NRG Foam 340B", "NRG Foam 360B", or "NRG Foam 370E", any thickness. https://iq.ulprospector.com/en/profile?e=148945 8/13 3/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ Base Coat: — Carlisle Roof Foam and Coatings "Premicote 1500" or "SeamlesSeal HT Acrylic Coating" applied at 1-1/2 gal/100-ft2. Top Coat: — Carlisle Roof Foam and Coatings "Premicote 1500" or "SeamlesSeal HT Acrylic Coating" applied at 171/2 gal/100-ft2. 29. Deck: NC Incline: 1 Foam: — "NRG Foam 340B", "NRG Foam 360B", or "NRG Foam 370B", any thickness. Base Coat: — Carlisle Roof Foam and Coatings "Premicote 1400", "SeamlesSeal Acrylic Coating", or "Premicote 1400DS", applied at 1-1/2 gal/100-ft2. Top Coat: — Carlisle Roof Foam and Coatings "Premicote 1400", "SeamlesSeal Acrylic Coating", or "Premicote 1400DS", applied at 1-1/2 gal/100-ft2. 30. Deck: NC Incline• 3-1/2 Foam: — "NRG Foam 340E", "NRG Foam 360E", or "NRG Foam 370B", any thickness. Base Coat: — Carlisle Roof Foam and Coatings "Poly Sil 2400" or Progressive Materials LLC "LS 2200 series" applied at 1-114 gal/100-ft.2. Top Coat: — Carlisle Roof Foam and Coatings "Poly Sil 2400" or Progressive Materials LLC %S 2200 series" applied at 1-1/4 gal/100-ft2. 31. Deck: NC Incline: Unlimited Foam: — "NRG Foam 340E", "NRG Foam 360E", or "NRG Foam 370B", any thickness. Base Coat: — Carlisle Roof Foam and Coatings "Poly Sil 2400" or Progressive Materials LLC "LS 2200 series" applied at 1-1/4 gal/100-ft z. Top Coat: — Carlisle Roof Foam and Coatings "Poly Sil 2400" or Progressive Materials LLC "LS 2200 series", applied at 1-1/4 gal/100-ft2. Surfacing: — Broadcast application of No.11 ceramic coated granules applied at a rate of 35-Ib./100-ft2. 32. Deck: NC Incline: 3-1/2 Foam: — "NRG Foam 340E",."NRG Foam 360B", or "NRG Foam 370B", any thickness. Base Coat: — Progressive Materials LLC "HS 3200 series" applied at 1-gal/100-ft2. Top Coat: — Progressive Materials LLC "HS 3200 series" applied at 3/4-gal/100-ft2. 33. Deck: NC Incline: Unlimited Foam: — "NRG Foam 340B", "NRG Foam 360B", or "NRG Foam 370B", any thickness. Base Coat: — Progressive Materials LLC "HS 3200 series" applied at 1-gal/100-ft.2. Top Coat:— Progressive Materials LLC "HS 3200 series" applied at 3/4-gal/100-ft2. Surfacing: — Broadcast application of No.11 ceramic coated granules applied at a rate of 35-Ib./100-ft2. 34. Deck: NC Incline: 1-1/2 Impact: 3 Foam: — "NRG Foam 340E", "NRG Foam 360E", or"NRG Foam 370E", any thickness. Base Coat: — "Premicote 1500" .or "SeamlesSeal HT Acrylic Coating" applied at 1-1/2 gal/100-ft.2. Top Coat: — "Premicote 1500" or "SeamlesSeal HT Acrylic Coating" applied at 1-1/2 gal/100-ft.2. 35. Deck: NC Incline: Unlimited Foam: — "NRG Foam 340E", "NRG Foam 360E", or "NRG Foam 370B", any thickness. Base Coat: — Momentive Performance Materials "SCM 3500 Series Silicone Coatings" applied at 1-gal/100-ft.2. Top Coat: — Momentive Performance Materials, "SCM 3500 Series Silicone Coatings" applied at 1-gal/100-ft.2. Surfacing (Optional): — No. 11 ceramic coated roof granules applied at 30-Ib/100-ft.2 into wet top coat. 36. Deck: NC Incline: 2-1/2 https:/fiq.ulprospector.com/en/profile?e=148945 9/13 3/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ Foam: — "NRG Foam 360E", or "NRG Foam 370E", any thickness. Base Coat: — Armor Coat Roof Coatings Inc. "Armor Coat AC 1000" acrylic coating applied at 1-112 gal/100-ft.2. Top Coat: — Armor Coat Roof Coatings Inc. "Armor Coat AC 1000" acrylic coating applied at 1-1/2 gal/100-ft.2. 37. Deck: NC Incline: 1/2 Impact: 4 Foam: — "NRG Foam 34013", "NRG Foam 3606", or "NRG Foam 370E", foamed plastic, any thickness. Base Coat: — Carlisle Roof Foam and Coatings "SeamlesSeal HailCoat" applied at 4.0 gal/sq. Top Coat: — "670HS Karna-Sil Ultra" coating applied at 1.5 gal/sq. Surfacing: — Broadcast application of No. 11 ceramic coated granules applied at 25 Ibs/sq. Class B Any of the following Class B systems may be considered as Class A combustible deck assemblies when a min of 400-Ibs of gravel is applied as a surfacing and gravel is maintained. 1 Deck: C-15/32 Incline: 1/2 Foam:-- Coating & Foam Solutions L L C "RT-2716" 11/2-in, minimum. Base Coat: — "670LS Karna-Sil" applied at 11/2-gal/100-ft2. Top Coat:— "670LS Karna-Sil" applied at 11/2-gal/100-ft2. Surfacing: — No. 11 roofing granules embedded into wet coating applied at 30-Ib/100-ft2. 2. Deck: C-15/32 Incline•. 1/4 Foam: — Coating & Foam Solutions L L C "RT-2717," 2.5 to 3.0-lb/ft3, 2-in. Base Coat: — "670LS Karna-Sil" applied at 3/4 to 1-gal/100-ft2. Top Coat: — "670LS Karna-Sil" applied at 3/4 to 1-gal/100-ft2. Surfacing: — No. 11 roofing granules embedded into wet coating applied at 25-Ib/100-ft2. 3 Deck: C-15/32 Incline: 1/2 Foam: —,Coating & Foam Solutions L L C "RT-2716," 2.5 to 3.2-lb/ft3, 11/2-in. minimum. Base Coat: — "670LS Karna-Sil" applied at 11/2-gal/100-ft2. Top Coat: — "670LS Karna-Sil" applied at 11/2-gal/100-ft2. Surfacing: — No. 11 roofing granules embedded into wet coating applied at 30-Ibs/100-ft2. 4 Deck: C-15/32 Incline: 1/2 Insulation: — Minimum 1-in. thick Coating & Foam Solutions L L C "RT-2718" (21/2 to 3.03/4-lb/ft3) spray applied foamed plastic Base Coat: — "670LS Karna-Sil" silicone roof coatings silicone roof coating applied at 11/2-gal/100-ft2. Top Coat: — "670LS Karna-Sil" silicone roof coatings silicone roof coating applied at 11/2-gal/100-ft2. Surfacing: — Broadcast application of No. 11 ceramic coated granules applied at a rate of 30 to 50-Ibs/100-ft2. Any of the following Class B roof covering systems may be considered as Class A combustible roof deck assemblies when a minimum of 400-Ibs/100-ft2 of roofing gravel is applied as a surfacing and gravel is maintained. 5. Deck: C-15/32 Incline: 1 Foam: — Minimum 2-in. thick "NRG Foam 340E", "NRG Foam 360B", or "NRG Foam 370B". Base Coat: — Carlisle Roof Foam and Coatings "Acry-Tek 9000" applied at 1-1/2 gal/100-f .2 https://iq.ulprospector.com/en/profile?e=148945 10/13 3/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ Top Coat: — Carlisle Roof Foam and Coatings "Acry-Tek 9000" applied at 1-1/2 gal/100-ft.2. Surfacing: — Broadcast application of No.11 ceramic coated granules applied at a rate of 25-Ibs/100-ft.2 6. Deck: C-15/32 Incline: 1 Foam:— Minimum 2-in. thick "NRG Foam 340E", "NRG Foam 360B", or "NRG Foam 370B". Base Coat: — "670HS Karna-Sil Ultra" applied at 1-1/2 gal/100-f .2. Top Coat: — "670HS Karna-Sil Ultra" applied at 1-1/2 gal/100-ft 2. Surfacing: — Broadcast application of No.11 ceramic coated granules applied at a rate of 25-Ib/100-ft 2. 7. Deck: C-15/32 Incline: 1 Foam: — Minimum 2-in. thick "NRG Foam 340E", "NRG Foam 360B", or "NRG Foam 370B". Base Coat: — Carlisle Roof Foam and Coatings "Acry-Tek 9000" series applied at 1-1/2 gal/100-ft2. Top Coat: — Carlisle Roof Foam and Coatings "Acry-Tek 9000" series applied at 1-1/2 gal/100-ft2. Surfacing: — Broadcast application of No.11 ceramic coated granules applied at a rate of 30-Ib/100-ft2. 8. Deck: C-15/32 Incline• 1/2 Insulation: — Minimum 2-in. thick "NRG Foam 340E "NRG Foam 360E", or "NRG Foam 370B". Base Coat: — "670HS Karna-Sil Ultra" or "670LS Karna-Sil" silicone roof coatings applied at 1-1/2 gal/100-ft2 Top Coat: — "670HS Karna-Sil Ultra" or "670LS Karna-Sil" silicone roof coatings applied at 1-1/2 g6l/100-ft2. Surfacing: — Broadcast application of No.11 ceramic coated granules applied at a rate of 30 to 50-Ibs/100-ft2. 9. Deck: C-15/32 Incline: 3/4 Foam: — Minimum 1-in. thick "Premiseal 250", "NRG Foam 340E", "RT-25250", "Premiseal 255", "RT-25255", "Premiseal 280", "NRG Foam 360B", "RT-28280", "Premiseal 285", "RT- 28285", "Premiseal 300", "NRG Foam 370B", "RT-30300", "Premiseal 305" or "RT-30305" Base Coat: — Carlisle Roof Foam and Coatings "Premicote 1400", "SeamlesSeal Acrylic Coating", or "Premicote 1400"DS" applied at 1-1/2 gal/100-f .2. Top Coat: — Carlisle Roof Foam and Coatings "Premicote 1400", "SeamlesSeal Acrylic Coating", or "Premicote 1400"DS" applied at 1-1/2 gal/100-ft.2. Surfacing: — Broadcast application of No.11 ceramic coated granules applied at a rate of 30-Ib/100-ft.2 into wet top coat. 10. Deck: C-15/32 Incline: 1/2 Foam: — Minimum 1-in. thick "NRG Foam 340B", "NRG Foam 360E", or "NRG Foam 370E". Base Coat: — Momentive Performance Materials "SCM 3500 Series Silicone Coatings", applied at 1-gal/100-ft 2. Top Coat: — Momentive Performance Materials "SCM 3500 Series Silicone Coatings", applied at 1-gal/100-ft.2. Surfacing: — Broadcast application of No.11 ceramic coated granules applied at a rate of 30-Ib/100-ft 2 into wet top coat. 11. Deck: C-15/32 Incline:112 Foam: — Minimum 1-in. thick "NRG Foam 360E", or "NRG Foam 370B". Base Coat: — Armor Coat Roof Coatings Inc. "Armor Coat AC 1000" acrylic coating applied at 1-1/2 gal/100-ft 2. Top Coat: — Armor Coat Roof Coatings Inc. "Armor Coat AC 1000" acrylic coating applied at 1-1/2 gal/100-ft.2. Surfacing: — Broadcast application of No. 9 roofing granules applied at a rate of 25-Ibs/100-ft 2. MAINTENANCE AND REPAIR SYSTEMS https://iq.ulprospector.com/en/profile?e=148945 11/13 3/10/2021 1. Deck: C-15/32 Existing Roof System: — Class A covered with: Membrane: — Firestone Building Products "APP160", Surfacing: — "97AF" or "98AF", at 1 gal/sq. TGFU.R12199 - Roofing Systems I UL Product iQ Class A - Fully Adhered Incline: 1/2 "APP170" or "Monoply Plus" (modified bitumen). 2. Deck: NC Incline: 1 Existing Roof System: — Class A, B or C (gravel may be removed) covered with: Base Sheet: — Type G3 (inverted). Membrane: — Firestone Building Products "APP160", "APP170" or "Monoply Plus" may be hot mopped - (modified bitumen). Surfacing: — "97AF" or "98AF", at 1 gal/sq and optional roofing gravel at 400 lb/sq. 3. Deck: NC Incline: 1 Existing Roof System: — Class A, B or C (gravel may be removed) covered with: Insulation: — Polyisocyanu rate, urethane, glass fiber, perlite, wood fiber, 6 in. max. Base Sheet: — Type G1, G2, G3 (one or more layers, optional). Membrane: — Firestone Building Products "APP160", "APP170" or "Monoply Plus" (one or more layers - modified bitumen). Surfacing: — "97AF" or "98AF"or "169"„ "" at 1 gal/sq. 4. Deck: C-15/32 Incline: 1/2 Existing Roof System: — BUR, any Class A, B or C. Base Coat: — "16AF", "78AF", "81 Brush" or "81 Trowel", applied at a min 2-1/2 gal/sq. Ply Coat: — One or more layers "Polyester Mat" or Type G1 or G2 base and ply sheets. Top Coat: — — "16AF" or "78AF", , applied at 4 gal/sq. Surfacing: — Gravel applied into wet cold process cement. 5. Deck: NC Incline: 3 Existing Roof System: — Class A, B or C built-up roof system. Surfacing: — "220AF Fibered Asphalt Emulsion", applied at 2 gal/sq. Ply Sheet: — One or more layers Polyester Mat. Surfacing: — " 220AF Fibered Asphalt Emulsion", applied at 3 gal/sq. 6. Deck: NC Incline: 1/2 Existing Roof System: — BUR, any Class A, B or C. Base Coat: — "16AF"or "78AF", applied at a min 2-1/2 gal/sq. Ply Coat: — One or more layers "Polyester Mat" or Type G1 or G2 base and ply sheets. Top Coat: — "16AF"or "78AF", applied at 4 gal/sq. Surfacing: — Gravel applied into wet.cold process cement. 1. Deck: C-15/32 Incline: 1/2 Class B https://iq.ulprospector.com/en/profile?e=148945 12/13 3/10/2021 TGFU.R12199 - Roofing Systems I UL Product iQ .Existing Roof System: — Class B covered with: Membrane: — Firestone Building Products "APP160", "APP170" or "Monoply Plus" (modified bitumen). Surfacing:— "97AF" or "98AF", at 1 gal/sq. Class A. B or C 1. Deck: C-15/32 Incline: See Note 1 Existing Roof System: — Any UL Classified existing single -ply membrane system, to retain existing Classification, covered with: Surfacing: — "670LS Karna-Sil" applied at 11/2-gal/100-ft2. Note 1: Classification (A, B or C) and maximum incline will be the same as that of the Classified Roofing System (TGFU). 2 Deck: C-15/32 Incline: 112 Existing Roof System: — Any UL Classified existing single -ply membrane system, to retain existing Classification, covered with: Surfacing: — "670LS Karna-Sil" applied at 11/2-gal/lo0-ft2. 3. Deck: C-15/32 Incline: 1 Existing Roof System: — Class A, B or C, insulated or uninsulated smooth surface BUR to maintain existing rating. Foam: — Minimum 1-in. thick "Premiseal 250", "Premiseal 40NRG Foam 340B", "Premiseal 60NRG Foam 360E","Premiseal 70NRG Foam 370B" Base Coat: — Carlisle Roof Foam and Coatings "Premicote 1400", "SeamlesSeal Acrylic Coating", "Premicote 140ODS", or "X-Tenda Coat Classic Acrylic" applied at 1-1/2 gal/100-ft2. Top Coat: — Carlisle Roof Foam and Coatings "Premicote 1400", "SeamlesSeal Acrylic Coating", "Premicote 1400DS", or "X-Tenda Coat Classic Acrylic" applied at 1-112 gal/100-ft2. 4. Deck: C-15/32 Incline: 1-1/2 Existing Roof System: — Class A, B or C insulated or uninsulated smooth surface BUR to maintain existing rating. Foam: — Minimum 1-in. thick "NRG Foam 340B", "NRG Foam 360E", or "NRG Foam 370B" Base Coat: — Carlisle Roof Foam and Coatings "Premicote 1500", "SeamlesSeal HT Acrylic Coating", or "X-Tenda Coat Classic HT Acrylic" applied at 1-1/2 gal/100-ft 2. Top Coat: — Carlisle Roof Foam and Coatings "Premicote 1500", "SeamlesSeal HT Acrylic Coating", or "X-Tenda Coat Classic HT Acrylic" applied at 1-1/2 gal/100-ft2. Last Updated on 2020-12-10 The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in.their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2021 UL LLC" https:/fiq.ulprospector.com/en/profile?e=148945 13/13