HomeMy WebLinkAboutProduct Approval Asphalt ShinglesBCIS Home Log In .I User Registration ( Hot
AProduct Approval
USER: Public User
.`: Submit Surcharge Stats & Facts ( Publications Contact Us I BCIS Site Map * Links Search ')
Product Approval Menu > Product or Application Search > egplication List > Application Detail
FL #
FL10674-R16
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
P
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg.keeler@owenscorning.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Roofing
Asphalt Shingles
A% CO
ov?!,P
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
[I Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/01/2099
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year�(of Standard)
i
FL10674_R16_COI_2020_01 COI_NIEMINEN.pdf
Standard
ASTM D1970
ASTM D3161
ASTM D3462
ASTM D7158
Year
2015
2016
2010
2019
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
12/11/2020
Date Validated
12/17/2020
Date Pending FBC Approval
12/26/2020
Date Approved
02/09/2021
Summary of Products
FL #
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
3-tab, 4-tab, laminated, starter and hip & ridge shingles
Shingles and Starters
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10674_R16_II 2020 12 11 FINAL ER OC_ASPHALT
SHINGLES FL10674-1116.12df
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert ]. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10674_R16_AE_2020_12_11_FINAL _ER_OC ASPHALT
SHINGLES FL10674-R16.pdf
Created by Independent Third Party: Yes
Back Next
The State of Florida is an AA/EEO employer. C yrlght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
- ..:. ® ektzi
• •
CilZ9tvlvtftruZ s"
l
i NEMO i etc.
Certificate of Authorization ##32455
i 353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
Owens Corning Evaluation Report 037940.02.12-1111
One Owens Corning Parkway FL10674-R16
Toledo, OH 43659 Date of Issuance: 02/06/2012
(740) 404-7829 Revision 11: 12/11/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction imaterials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7th Edition (2020) Florida Building Code sections noted herein.
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation'. Reports by the named client constitutes agreement to notify NEIVIO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEIVIO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen P.E.
?� :F �.;q?' =' The facsimile seal appearing was authorized by Robert
',FS�1�1g�'+' Nieminen, P.E. on 12/11/2020. This does not serve as an
'+'
Florida Registration No. 59166, Florida'DCA ANE1983
;'rt.,,,,;,i,,,+++' electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor,does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates. , ',
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2018 NEMO ETC, LLC
ONEMOletc.1
ROOFING SYSTEMS EVALUATION:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 711 Edition '(2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015
1507.2.5, R905.2.4 Material standard ASTM D3462 2010
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019
Owens Corning
Declaration
Equivalency Declaration
08/06/2019
PRI(TST5878)
ASTM D1970
06-382-02-01
10/24/2017
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-132453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
PRI (QUA9110)
Quality Control
Service Confirmation
04/05/2020
PRI (QUA9110)
Quality Control
Florida BCIS
Current
TAOLE 'ASPHALTSHINGL`ECOMliQ111E�ITS,
,
.•N,
Type
Product`
Plant(sjDeScr�ptipn
APy{.
l l a E
iwatenand
Scar
%
Starter Strip Shingle
H-TX, OR
AcceSso.ry�
ASTM D3462
starter strips for asphalt roof shingles
Starter Strip Plus
MN, OR
Starter
SRS TopShield Starter
MN, OR
Steps %
Starter Shingle Roll
NH
ASTM D1970
mineral -surfaced, fiberglass -reinforced,
self -adhering SBS modified bitumen starter
y
Su
GA, CA, CO, I -TX, NJ, OH,
ASTM D3462
fiberglass reinforced 3-tab asphalt
p reme°
TN, OR, IL
roof shingles
«:
Berkshire
MN
ASTM D3462
fiberglass reinforced, 4-tab asphalt
.,-
roof shingles
Duration Premium
CA, OR
Duration* Premium COOL
CA
`Asphalt;
TruDefinition° Duration*
Shingles
TruDefinition° Duration*
IN, CA, CO, I -TX, FL, NJ, OH,
MN, OR, GA, IL, TN
fiberglass reinforced, laminated
'
Designer Color Collection
ASTM D3462
asphalt roof shingles
°
Oakridge
GA, IN, CA, CO, H-TX, I -TX,
s= jt
FL, NJ OH, TN
TruDefinition°Oakridge°
H-TX, I -TX
WeatherGuard° HP
TN
MEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 2 of 10
Material
Type `; Product Blant(s) Standard,- Description
..
Berkshire' Hip and Ridge MN
!f
Shingles with Sealant
Hip and DuraRidge® Hip and Ridge
MN fiberglass reinforced, hip and ridge
Ridge ' Shingles with Sealant ASTM D3462
asphalt roof shingles
Shingle's ProEdge® GA, CA, OH, OR
WeatherGuard® HP Hip and TN
5.1 This is a building code -evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Reportpertains to above -deck roof components. Roof decks and.structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications
6 ,7,TABLE 21�1'1N1ND�GLASSIfICATIONS ASPHALTSHINC�LES x a
t ` Product
_1FBG Table 1507.2:7.1 or R905 2 6 1: "•
Supreme®
ASTM D3161(F) & ASTM D7158(H)
Berkshire®,
Duration® Premium
Duration® Premium COOL
TruDefinition® Duration®
TruDefinition® Duration® Designer Color Collection
Oakridge
TruDefinition° Oakridge®
WeatherGuard® HP
5.5.1 Classification by ASTM D7158:
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
�I
I
i
i
�I
NEW ETC, LLC Evaluation Report 037940.02.12-Rll
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION IF1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 3 of 10
A.
ONEMOIetc.
WIND,CIASSI�ICA7'ION5rS1'ARTERSTRIpSANDHIP$tY;FiIDGE�„,,,:.,�A°
Product
FBC Tab le;1 1507 2 7 1 o`r R905 2.615 „
Starter Strip Shingle
'
StarterStrtps,--�
Starter Strip Plus
ASTM D3161, Class F
SRS TopShield Starter
Berkshire' Hip and Ridge Shingles with Sealant
Hip &Ridge a>
DuraRidge® Hip and Ridge Shingles with Sealant
Shipgles
ASTM D3161, Class F
ProEdge®
WeatherGuard® HP Hip and Ridge Shingles
' x
5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6 2 ACCESSORY STARTERS
Y f r F f 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
Faittmdarfaymard --Deck
sedadhared
t"Jeatherfectco
gnderlaymant
Drip edge
` w Ph%located
r-r from eave
tr�sten first
self-sealing adhesive
Positioned along cave
as*
sh!nglOP
a
removed
Starter Strip shingle overhangs caves and takes 'A -21V
Pckureracla�mant "-'0�' �c
am
Drip
I �
A~
r �
�' allsloatad
` Z -3'hem cave
ha rMstarterstdpPlus " Sti�sainnggeraa
with6`removad • • paritt�rtdalpa "sra
Smrtar4 Plus overhangs ewes and rakes 114 -W
Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus
MEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization>t32455 71" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 4 of 10
i
4 U
NEMO I etc.
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
— Deck
err Underlayment
Drip edge
Drip edge
Starter Shingle Roll adhered
directly to underlayment and
primed drip edge
Self-sealing adhesive
positioned along eaves
Figure 3: Starter Shingle Roll
6 3 ASPHALT SHINGLES ., ;, x
t S &>r
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) Hails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Berkshire' shingles require minimum five (5) nails per shingle.
➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Supreme:
Normal Mansard or Area pares
Wind Areas High Wind deavanes y
Area pare vientos nornleles Areas vientos /uertes
rV 2" {g r2" V
11" 11"
W Exposure
Exposition
Figure 4: Minimum Nailing, Supreme
(Standard Size)
,I
NEMO ETC, LLC
Certificate of Authorization #32455
Normal Mansard or Area pare
Wind Areas High Wind desvanesy
Area pare vientos normeles Areas vientos faertes
12 12 1
• • • • • • • • • •
5 518` Exposure
Exposleidn
Figure 5: Minimum Nailing, Supreme
(Metric Size)
7n' EDITION (2020) FBC NON-HVHZ EVALUATION
Owens Corning Asphalt Roof Shingles
Evaluation Report 037940.02.12-1111
FL10674-1116
Revision 11: 12/11/2020
Page 5 of 10
6.3.1.2 Berkshire®:
Figure 6: S-Nail Pattern, Berkshire
NEW etc.
Sealant strip
La tlra de sellsdor
8W 8W, BVt" Bye �0
t"
Figure 7: 6-Nail Pattern, Berkshire
;.Seam�:s(rip
is fire deselledbr
8 W, 8
t"
Asphalt [Doting oeinenl
Ceinentoda,'tecltoJe astatto
Figure 8: Mansard or Steep Slope Pattern, Berkshire
NEMO ETC, LLC Evaluation Report 037940.02.12-Rii
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 12:12/31/2020
Page 6 of 10
6.3.1.3
MEMO ! etc.
Duration® Premium, TruDefinition® Duration, Duration® Premium COOL & TruDefinition® Duration' Designer Color
Collection:
4-NalUFastsntng, Pattein
4ureNai10:fa5teninp area.'width
Nail, Typical;
�.
' :.
...
as�/iF�1Y...
!�=�$,%t,W ,. �. ..x.�s n,.f J..:..�
?k$ ...��aii ,� �,.�`: a"Q'ikilYi GtB'i1 ,$tX[� ,..8 ... �!♦;:
w
6r-118"
5-5t8"
�
�posue
y %x;
Figure 9: Standard 4-Nail Pattern, Duration
6-Nail Fastening Pattetn-.
Sure Nail0fas nIng area vAdth.
Nail, Typical,
12' 1"
�•., -. oaks
-.,,K_, h ::'; � ,TM"tFs�reCCax
8418'°
'A
exposiae.
4
J
ii ,f
Figure 10: 6-Nail Pattern, Duration
Figure 11: Mansard or Steep Slope Pattern, Duration
NEMO ETC, LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 7 of 10
6.3.1.4 TruDefinition®Oakridge", Oakridge":
'4 Nail.1'affem .
queriia,cgii 4:c1avos,;
Figure 12: Standard 4-Nail Pattern, Oakridge
i
~` NEnno etc.
6 Nall Nttem
Esquama'con 6 ctavos
Fxpo;iadrr.de5b/BFu/g.: Fxposictep;deb/8
Figure 13: 6-Nail Pattern, Oakridge
. Fastening'for 5lopes'Greattr Than 21.12.
SureNait" fastening area width
Nall, rypleai.
12" r 12"
Four 1"-Spots
Figure 14: Mansard or Steep -Slope Pattern, Oakridge
6.3.1.5 WeatherGuard" HP:
1" 12' 12" 1`
6 7y Y : h
f
I I 9 , � \AF
3
:3'
m clam
�,%fQaE�d9 G IiJ6 pub fspoektbie de 6
Figure 15: 6-Nail Pattern, WeatherGuard HP
6 Nd Pattern
Esquem con 6 ctavos
5 618' Exposure
Expinift de 6 $19 pufg.
Ntlif 611r from bot im
of Oboe
o a 61�t#Wda to
enet$ iCtf tir m t'da
6 8d e&
Faur 1" Sprats of p4�a4 Roof Comm
Cuetrapolos de cemwo do feria do ssNto do t ptr da
Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP
NEW ETC, LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization N32455 71H EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 12: 12/11/2020
Page 8 of 10
ONEMOjetc.
6 4 HIPAND RIDGE$HINGLES r
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire 'Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require
minimum two (2) nails per shingle.
➢ WeatherGuard® HP Hip and Ridge Shingles and ProEdge® require minimum four (4) nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.4.1.1 Berkshire® Hip and Ridge with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant:
Fig. A
Prevailing Wind Direction
�— Direction del viento predominante
8'E�posure
Erpsicidn de&
A
Figure 17: Isometric View, Berkshire and DuraRidge
6.4.1.2 WeatherGuard® HP Hip and Ridge Shingles:
Fig. A;
V E_ Prevailing Wlnd
Dlreiifbn
--►* g 4
I
1
I
1
L.
�
T
F
f
Figure 29: Isometric View, WeatherGuard HP Hip and Ridge
Figure 16: Plan View, Berkshire and DuraRidge
'Flg; C Hi'p &Ridge Single Fastening'
Topillevi -
Nails Naha'
7"
1" 1.
V' Erposure:
Figure 20: Plan View, WeatherGuard HP Hip and Ridge
NEMO ETC, LLC Evaluation Report 037940.02.12-Rii
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 9 of 10
6.4.1.3 ProEdee®:
P ravading
Wind Dirt etilon Start Stile
A--, 6. up -
haver E coed
Fostaovrs with
Roof Cement
Figure 21: Isometric View, ProEdge
NEMO etc.
F g
12, UMM
Figure 22: Plan View, ProEdge
REQUIREMENTS'1.7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
PLANTS:8. MANUFACTURING
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
PRI Construction Materials Technologies, LLC— QUA9110 ; 813 621-5777;
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization ✓<32455 7'" EDITION (2020) FBC NON-IiVHZ EVALUATION FL10674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 10 of 10