HomeMy WebLinkAboutAPPROVED TILTON STRUCTURAL PLANSPROJECT NAME & ADDRESSEILEEN TILTON 5306 HICKORY DRIVE FORT PIERCE, FL 34982 Ph.#: (772) 332-8272 REVDATEDESCRIPTIONREVISIONSATLANTIC KEY ENERGY LLC+1 (407) 988-02737006 STAPOINT CTSTE BWINTER PARK, FL 32792Drawn by:A.V.Checked by:Date:12/29/2021Sheet size:ANSI B 11" X 17"Scale:AS SHOWNSHEET NUMBERSG-1SIGNATURE WITH SEALO.T.SHEET NAMESTRUCTURALGENERIC PLANGENERAL INSTALLATION NOTES:1. THIS IS A SINGLE SHEET UNIVERSAL PV STRUCTURAL PLAN.COMMON SOLAR COMPONENTS EXAMPLES SHOWN,APPEARANCE MAY VARY. ELECTRICAL PLAN IS SEPARATELYSEALED DOCUMENT.2. CURRENT FBC 2020 (7TH EDITION) FLORIDA BUILDING CODE& ALL REFERENCED.3. THIS UNIVERSAL PLAN IS INTENDED FOR RESIDENTIAL PVINSTALLATIONS CONTRACTOR SHALL COMPLY WITHCURRENT NFPA 1 SOLAR PROVISIONS.4. DESIGNED FOR RISK II, V=ULT170MPH. EXPOSURE C, &V=ULT160MPH. EXPOSURE D.5. THIS PLAN OFFERS 5 INSTALLATION METHODS.a.FRAMING METHOD. SEE DRAWINGS.b. SHEATHING METHOD. SEE DRAWINGS.c. STANDING SEAM METAL ROOF. USE CLAMP OFCHOICE:·S-5·RT-MINI3. SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOADTO STRUCTURE.4. THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMPAT EVERY MODULE RAIL CROSSING POINT WITH MINIMUM 4CLAMPS PER MODULE. ADJOINING MODULES SHALL SHAREMID CLAMPS. MODULES MAY BE LANDSCAPE OR PORTRAITAT CONTRACTOR OPTION.5. PV MOUNTING RAILS SHALL BE INSTALLED PERPENDICULARTO ROOF FRAMING. SEE ROOF ATTACHMENT SPAN TABLEAT UPPER RIGHT.6. THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PVMODULE.7. CONTRACTOR SHALL SUBMIT & ABIDE BY THE RAIL OEMINSTRUCTIONS.8. RAILS SHALL ATTACH TO ROOF THRU L-FEET AS SHOWNHEREON. L-FEET REQUIRE FLASHING WHICH CAN BE SF-SO(SELF-FLASHING, SHEETING ONLY) SHOWN HEREON OR MIN4"x8"x26GA. GALV., 0.032 ALUM, OR INDUSTRY STANDARDOEM FLASHINGS OVER ATTACHMENTS LAGGED INTO ROOFFRAMING, E.G. UNIRAC SOLARMOUNT, UNIRAC FLASHKIT,OTHER ACCEPTABLE TO AHJ.9. SF-SO TOOF ATTACHMENTS ARE INTENDED TO BEINSTALLED INTO SHEETING ALONE, HAVE BEEN SO TESTEDAND ARE RATED AT 900-POUNDS ALLOWABLE PER ROOFATTACHMENT.10. ALL FLASHINGS SHALL BE INSTALLED IN A GENEROUS BEDOF FLORIDA PRODUCT CONTROL APPROVED (PCA)POLYURETHANE ROOF SEALANT11. LONG L-FEET &/OR STANDOFFS ARE PERMITTED AS NEEDEDFOR ROOF CLEARANCE.FLASH LOC DUO ATTACHMENTSCALE: NTS3.1ES-1NOTESSCALE: NTS1ES-1FLORIDA WIND ZONES ASCE 7-16SCALE: NTS2ES-1FLORIDA ROOF ATTACHMENT SPACING (FEET):ROOF HEIGHT < 30-FT & ROOF SLOPE < 30°WIND (MPH)PZ1 PZ2PZ3 UNIRAC RAIL110 8 6 4 SM-L120 8 8 2 SM-L130 6 4 2 SM-L140 6 42SM-S150 6 4 2 SM-S160 6 4 2 SM-HD170 4 4 N/A SM-HD180 4 2 N/A SM-HDPZ1' : FIELD-OF-ROOF --> INTERIORPZ1 : FIELD-OF-ROOF --> EXTERIORPZ2 : ROOF PERIMETER(MIN. 3' LEAST OF 40% EAVE HEIGHT OR 10%BUILDING L/W.)PZ3 : OUTSIDE CORNERSL & W =PZ2, a=PZ2 WIDTH, h=EAVE HEIGHTSHINGLEMETAL ROOFTILE ROOFFLAT ROOFRT-MINI ATTACHMENTSCALE: NTS3.2ES-1Q-BASE ATTACHMENTSCALE: NTS4.1ES-1SOLAR STACK ATTACHMENTSCALE: NTS6.1ES-1S5 ATTACHMENTSCALE: NTS5.1ES-1INSTALLATION OF THE SSPEDESTAL AND DISTANCEBETWEEN THEM (A, B, C)MUST BE DETERMINEDACCORDING TO THEMODULE MANUFACTURERINSTRUCTIONS.I CERTIFY THAT THE FRAMING AND SHEETHNG SAFELY ACCOMMODATES CALCULATED WIND UPLIFT, LATERAL FORCES, AND EQUIPMENT DEADLOADS OF THIS STRUCTURE.THIS IS ATTESTED TO MY SIGNATURE AND SEAL ON THIS DOCUMENT.