Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - WINDOWS SINGLE HUNG1/22/2021 Florida Building Code Online Business & Professional Regulation !J Al--_•- - BCIS Home Log In User Registration I Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search dbore 4-0, Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL23358-R5 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer CGI Windows and Doors Address/Phone/Email 10100 NW 25 Street Miami, FL 33172 (305)593-6590 Lmiller@pgtindustries.com Authorized Signature Jens Rosowski josowski@pgtindustries.com Technical Representative Lynn Miller, P.E. Address/Phone/Email 1070 Technology Dr N Venice, FL 34275 (941)486-0100 Ext21142 Imiller@pgtindustries.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the A. Lynn Miller, P.E. Evaluation Report Florida License PE-58705 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 02/19/2023 Validated By Steven M. Urich, PE Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Validation Checklist - Hardcopy Received FL23353 RS COI Cert of Independence.pdf Standard TAS-201 TAS-202 TAS-203 Year 1994 1994 1994 https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvxHl9oecA°/`2bZilHy9k°/`2fUYxUm7°/`2bJJxOylbgdNbuaBuCnPwp/o3d%3d 1/2 1/22/2021 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 09/04/2020 Date Validated 09/06/2020 Date Pending FBC Approval 09/21/2020 Date Approved 12/16/2020 Summary of Products FL # , Model, Number or Name Description 23358.1 SH-4000A Non -Impact Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23358 R5 II SH4000 CGi -REV E.pdf Approved for use outside HVHZ: Yes Verified By: A. Lynn Miller, P.E. 58705 Impact Resistant: No Created by Independent Third Party: No Design Pressure: N/A Evaluation Reports Other: Please see the enclosed documents for product FL23358 R5 AE 3H4000 Eng Eval CVI.pdf performance information, anchorage details, and anchor type, Created by Independent Third Party: No size, and spacing information. 23358.2 SH-4100A Impact Resistant Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23358 R5 II SH4100 CGI - REV E.pdf Approved for use outside HVHZ: Yes Verified By: A. Lynn Miller, P.E. 58705 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: N/A Evaluation Reports Other: Please see the enclosed documents for product FL23358 R5 AE SH4100 Eng Eval CGI.pdf performance information, anchorage details, and anchor type, Created by Independent Third Party: No size, and spacing information. back FEE Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ®UC F Credit Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvxHl9oecA%2bZilHy9k%2fUYxLlm7%2bJJxOylbgdNbuaBuCnPw%3d%3d 2/2 Engineering Evaluation Report # 4100-082820 Prepared by: A. Lynn Miller, P.E. 1070 Technology Dr. N. Venice, FL 34275 (941) 480-1600 Florida Registration: #29296 Manufacturer: CGI Windows and Doors 3780 W 104th St. Hialeah, FL 33018 Product Description: 4100A Series Impact -resistant Aluminum Single Hung Window, (LM & SM), FL-23358 Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(d). The product listed herein complies with requirements of the current Florida Building Code. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). Supporting Technical Documentation: 1. Approval document: drawing number SH4100FLPA Rev E, signed and sealed by A. Lynn Miller, P.E. 2. Test Report(s) No. FTL 17-7382, 18-8281 & 20-2108.1-6, signed and sealed by Idalmis Ortega, P.E. Fenestration Testing Laboratories, Nokomis, FL 34275 TAS 201-94 Large Missile Impact Test TAS 202-94 Uniform Static Air Pressure Test TAS 203-94 Cyclic Pressure Loading Test 3. Anchor calculations, signed and sealed by A. Lynn Miller, P.E., dated 9/25/18 & 8/27/20. 4. Miami -Dade RER Product Control Section NOA's; PVB Interlayer by Kuraray America, Inc and Saflex PVB Interlayer by Eastman Chemical Company Limitations and Conditions of use: • Maximum Design Pressure: +55.0/-65.0 psf • Maximum Overall Buck Size: 52-1/8" x 77" • Maximum DLO: 48-13/16" x 35-1/8" • Units must be glazed per ASTM E1300-09, refer to approval document for glazing details. • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions. • Frame and sash material to be extruded Aluminum. • Units must be installed in accordance with approval document, SH4100FLPA. LYN/V'%,. ��'��'• titCE�SF `<<��r� * No. 58705 449/3/20 0 STATE OF 1(// tjl►tI111 A. Lynn Miller, P.E. P.E. # 58705 SERIES 4100A IMPACT RESISTANT SINGLE HUNG WINDOW 1) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2) SHUTTERS ARE NOT REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. 3) MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 4) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT LENGTH. INSTALLATION ANCHORS SHOULD BE SEALED. OVERALL SEALING/FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 5) SHIMS ARE REQUIRED AT EACH FLANGE ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. WOOD BUCKS, BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. 6) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WIND LOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. ANCHORS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. FLORIDA PRODUCT APPROVAL#23358 53-1/8""TIP-TO-TIP WIDTH f 52-1/8" BUCK WIDTH NO ANCHORS REQUIRED IN HEAD 9" MAX. B T H 48-13/16" 35-1/8" VISIBLE LIGHT SEE FRAME TABLE2 VISIBLE LIGHT A 77" BUCK MAX. FROMCENTER OF MEETING RAIL HEIGHT8" 35-178" VISIEE TIP -TO LIGBLE 2 TIP 147-11/16" HEIGHT 1 9" MAX. B NO ANCHORS REQUIRED IN SILL TYP. FLANGE FRAME ANCHOR LOCATIONS (d-) MAX. SIZE B GLASS STACK I~ GLASS STACK- 1/8" ANNEALED GLASS 1/8" HEAT -STRENGTHENED GLASS .090" PVB .090" PVB 118" ANNEALED GLASS 1/8" HEAT -STRENGTHENED GLASS 5/16" LAMI. GLAZING 5/16" LAMI. GLAZING GLASS TYPE 1 GLASS TYPE 2 TABLE is Laminated Glass Types 1 1/8" Annealed, 0.090" PVB, 118" Annealed 2 1/8" Heat -strengthened, 0.090" PVB, 1/8" Heat -strengthened INTERLAYER MAY BE SAFLEX PVB OR TROSIFOL PVB DESIGN PRESSURE RATING I IMPACT RATING +55/-65 PSF RATED FOR LARGE & SMALL MISSILE IMPACT RESISTANCE 52-118" BUCK WIDTH SEE O.C. ON 8-1/2" MAX TABLE 3,—j SHEET 3 p li 52-1/8" BUCK WIDTH +{ —+D C 48-13/16" VISIBLE LIGHT 35-1/8" FRAME C L 48-13116" VISIBLE LIGHT 35-1/8" FRAME I VISIBLE LIGHT 6" MAX. O.C. � VISIBLE LIGHT SEE O.C. C C TABLE 3, , SHEET 3E 7T BUCK HEIGHT VISIBLE LIGHT VISIB47�-11/16" VISIBLE 7T35.1I8"�BUCK HEIGHT 1 LIGHT 8-1/2" MAX. f D TT J 2-7/8" MAX. J —►D ►•— 6" MAX. O.C. TYP. INTEGRAL FIN FRAME TYP. INTEGRAL FIN FRAME ANCHOR LOCATIONS @ MAX. SIZE ANCHOR LOCATIONS @ MAX. SIZE (INSTALLED WITH SCREWS) (INSTALLED WITH NAILS 1/2" NOM. GLASS BIT DOW-791, 899, 983 OR RGS-7700 BACKBEDDING EXTERIOR a TYP. GLAZING DETAIL Tltle: SH WINDOW INSTALLATION DexcdpRon: GENERAL NOTES & ELEVATION Revialon: ADDED ULTRACON+ ANCHOR Seriee/Arodel: I Scale: I Sheet. SH-4100A NTS 1 OF 4 ORIEL CONFIGURATION ALLOWED PROVIDED THAT THE FRAME VISIBLE LIGHT HEIGHT OF 35-1/8" AND THE FRAME HEIGHT, AS SHOWN ABOVE, IS NOT EXCEEDED. 1/511111 f11 LYNN,yj ���• V%CEN&t ���� ; Q':' •'•� �; * NO.58705 ` •, ....yyjj��a� i' -e {yyN9.:- '. (!////jj 9/'/20 ife�LLL` 0 •.• STATE OF ([/ %� ',C �'• ••' IN r 1110`�. '�dN � A. LYNN MILLER, P.E. 87 P.E.# 505 /�/��/(''�.�.��^��-�\\77Impact Resistant Windows & Doors �..! WE'RE STRONGER" aloe W. 11140 awe:, Xleleen, FL aaau iel: 8o6.688.869e I faa: 8o6.6e8.66e8 Dmwn By: J ROSOWSKI pab, 09/20/17 PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE N. , (941) 480-1600 Rev. W. JR Ray. 08/27/20 Co g DOORS, LIMITED COPIES FOR PERMITTING. D—bg N.. SH4100FLPA E REGISTRATION #29296 IP-TO-TIP HEIGHT BUCK HEIGHT EXTERIOR a EDGE DISTANCE If_ EMBEI NO ANCHORS REQUIRED IN FLANGE FRAME SILL VERTICAL SECTION B-B El EMBEDMENT DISI r TIP -TO -TIP WIDTH V HORIZONTAL SECTION A -A EDMENT E JCE #12 STEEL SELF-DRIL SMS (G5) SHOWN INSTALLED DIRECTLY INTO METAL. INSTALLED INTO APPROVED ALUMINUM, STEEL FRAMING OR STEEL STUD. Minimum Minimum mEmbedment Max. O.C. \ NOTES Anchor Substrate Edge (Above !Below 1) USE ONLY SUBSTRATE APPROPRIATE Distance Meeting Rail) ANCHORS LISTED IN TABLE 2. FOLLOW #12 STEEL LOCKS AT EMBEDMENT AND EDGE DISTANCE P.T. Southem Pine (SG = .55) 9/16" 1-3/8" 21" / 23" SELF -DRILLING TOP SASH LIMITS. ANY INSTALLATION OPTION #12 Steel Aluminum, 6063-TS min. 3/8" 0.078" 21" / 23" SMS (G5) RAIL SHOWN MAY BE USED ON ANY SIDE OF SMS (�E OR THE WINDOW. Screw (G5) Steel Stud, Gr. 33 min. 3/8" 0.045" (20 Ga) 21" / 23" =9 BOTTOM A36 Steel 3/8" 0 050" 21" / 23" LIFT RAIL 2) MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE 2. ALL WOOD P.T. Southern Pine (SG = .55) 1" 1-3/8" 21" / 23" BUCKS LESS THAN 1.112" THICK ARE TO 1/4" Steel Concrete (min. 2.9 ksi) 1-1/8" 1-3/8" 21" / 23" 7 BE CONSIDERED 1X INSTALLATIONS. 1X UltraCOn Grouted CMU, ASTM C-90 ( ) 2-1/2" 1-314" 21" ! 23" 36 WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" Ungrouted CMU, (ASTM C-90) 1-1/8" 1-1/4" 12-1/4" / 12-1/4" EXTERIOR 11 THICK OR GREATER. IX AND 2X BUCKS P.T. Southem Pine (SG = .55) 1" 1-318" 21" ! 23" (WHEN USED) SHALL BE DESIGNED TO 14' Steel Concrete (min. 3.0 ksi) 1-7/8" 1-3/8" 21" 123" PROPERLY TRANSFER LOADS TO THE Ultracon+ Grouted CMU, (ASTM C-90) 2-1/2" 1-3/4" 21" / 23" MULLION SECTION STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF Ungrouted CMU, (ASTM C-90) 1" 1-1/4" 12-1/4" / 12-1/4" APPROVED MULLION, MAY BE VERTICAL OR HORIZONTAL. THE ENGINEER OR ARCHITECT OF P.T. Southern Pine (SG = .55) 1" 1-3/8" 21" / 23" RECORD. 1/4" 410 SS Concrete (min. 3.35 ksi) 1" 1-34" 21" / 23" 3) SEE SHEET 1 & TABLE 2 FOR SPACING CreteFlex Concrete (min. 3.35 ksi) 2-1/2" 1" 21" / 23" REQUIREMENTS. Ungrouted CMU, (ASTM C-90) 1-3/4" 1-1/4" 21" / 23" 4) MAX. SHIM THICKNESS TO BE 1/4". 1) ANCHOR MUST EXTEND A MIMIMUM OF 3 THREADS BEYOND ANY METAL SUBSTRATE. 2) "UNGROUTED CMU" VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. NY LYNA • • M�� �' 5) GLASS SHOWN IS FOR ILLUSTRATIVE ^ •"' •' • • •., �� PURPOSES ONLY AND MAY DIFFER TO Impact Resistant = ��•.'' b10ENSR '•'p MEET DESIGN REQUIREMENTS. nty; SH WINDOW INSTALLATION Drawn W. J ROSOWSKI Windows & Doors WE'RE STRONGER'" Q': *: NO.58705 '• *= 1.<t" Nl.le.h......,. D"crrPtren: Date; Tel:...... 8.....I ..............3 INSTALLATION FOR FLANGE WINDOWS 09/20/17 PREPARED BY LYNN MILLER ��'. 9j3�20 1(/� STATE OF 1070 TECHNOLOGY DRIVE O '• Revferon: Rev. By: Rev. DaN: N. VENICE, FL 34275 ''tORIOP,.•' ADDED LILTRACON+ ANCHOR JR 08/27/20 (941)480.1600 C... RS,LIMITED LICENSE TOM KECOPIE8 �'�/i�NAL Seriea/Model: Seale: Sheet: Orawrng No. ReV: SH-4100A NTS 2 OF 4 SH4100FLPA E RATIONOR A. LYNN MILLER, P.E. #292ING. REGISTRATION #29296 EGIS p.E.#SB705 BUCK HEIGHT --r-I EMBEDMENT EDGE _ DISTANTCE ----- - -� EMBE 29 LOCKS AT TOP SASH RAIL OR BOTTOM LIFT RAIL buUK WIUIH --I HORIZONTAL SECTION C-C Min. Min. Max. On -center Max. Anchor Substrate Embedmentor Edge Distance, Corner Metal Tickness Distance Distance 2-1/2" x .11Y' Box Nail P.T. Southern Pine (SG = .55) - We..6" @ Head/Sill 6" @ Jambs 2 7/8 2-1/2" x .131" Common Nail P.T. Southern Pine (SG = .55) - 318" 2-1/2" x .145" Rooting Nail P.T. Southern Pine (SG = .55) 3/8" P.T. Southern Pine (SG = .55) 1-3/8" 112" 17-9/16" @ Head/Sill Aluminum, 6063-T5 min 0.100" W. #10 Steel SMS Screw (G5) 15" @ Jambs Steel Stud, Gr. 33 min. 0.057" 318" A36 Steel 0,050" 3l8" P.T. Southern Pine (SG = .55) 1-3/8" 9116" 17-9/16" @ Head/Sill 8-1/7 Aluminum, 6063-T5 min. O. 125" 7/16" #12 Steel SMS Screw (G5) 20" @ Jambs Steel Stud, Gr. 33 min. 0.0711, 7I16" A36 Staal 0.050" 7N6" 1) ANUHUK MUJ 1 CA 1 CNU A MINIIMUW1 Vr 3 I rIKCAIJJ Dc i V1vV niv r ry 2) PANHEAD, FLATHEAD OR HEXHEAD ARE ACCEPTABLE FOR #10 SCREW; FOR # 12 SCREW, USE ONLY PANHEAD OR HEXHEAD. RENT APPROVED ALUMINUM, STEEL FRAMING OR STEEL STUD. MULLION SECTION APPROVED MULLION, MAY BE VERTICAL OR HORIZONTAL. MOWN 'TALLED CTLYINTO METAL. #10 STEEL SELF -DRILLING SMS (G5) #12 STEEL SELF -DRILLING SMS (G5), SEE TABLE 2 REMOVE FIN AT MULLION NOTES 1) USE ONLY SUBSTRATE APPROPRIATE 111 I 1 111111 �� �( N....... ANCHORS LISTED IN TABLE 3. FOLLOW EDGE AND EDGE DISTANCE LIMITS. ANY EXTERIOR DISTANCE EMBEDMENT INSTALLATION OPTION SHOWN MAY BE USED ON Impact Resistant �� •`\,�'� Q, tiCEN3F ANY SIDE OF THE WINDOW. Title: Drown By: windows & Doors ` Q•: • p �� WE'RE.TRD1IS11" N0.58705 *_ -' 2)2X WOOD FRAMING OR BUCK, 1-1/2"THICK OR SH WINDOW INSTALLATION J ROSOWSKI 11.0 = *: } GREATER. Description: Date: r h............ Ira.: s..........e = PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE 3) SEE SHEET I FOR SPACING REQUIREMENTS. INSTALLATION FOR FIN WINDOWS 09/20/17 •', 9/3/20 O •.• STATE OF <(/ —,� EMBEDMENT Revision: Y. By: Rev. Date: N. VENICE, FL 34275 ••. FtORIOP.•'• 4) MAX. SHIM THICKNESS TO BE 1/4". ADDED ULTRACON+ ANCHOR JR 08/27/20 (941)480-1600 TONAL COPYRIGHT® 202D CGI WINDOWS& DOORS, L MITED LICENSE TO M E COPIES FORRA PERMITTING' VERTICAL SECTION D-D 5) GLASS SHOWN IS FOR ILLUSTRATIVE Series/Model: Scale: Sheet: Drewfng No. Rev: /� 111111101, PURPOSES ONLY AND DESIGN REQUIREMENTS. Y DIFFER TO MEET SH-4100A NTS 3 OF 4 SH4100FLPA E A. LYNN MILLER. P.E. P.E.# 58705 REGISTRATION #29296 -I F Item Description 1 Flange Frame Head 2 Flange Frame Sill 3 Flange Frame Jamb 4 Integral Fin Frame Head 5 Integral Fin Frame Sill 6 Integral Fin Frame Jamb 7 Sash Bottom Rail 8 Sash Top Rail 9 HD Fixed Meeting Rail 10 Sash Side Rail 11 ISash Bottom Lock 12 lVinyl Sash Stop 20 Vinyl Bulb, Flex PVC 70 21 Frame Comer Gasket, Polyethelyne, opt. 22 Sash Comer Gasket, Polyethelyne, opt 23 Fixed Meeting Rail Plug, Rigid PVC 24 Wstp.,187" X.230" Fin Seal 25 Frame/Sash Comer Sealant, opt. 26 113alance Take-out Clip 27 Balance 28 Sash Cam, Nylon 29 Sweep Latch, Zinc 30 #6 X5/8" Ph. FI. SMS Latch Screws 31 Setting Block 1/8" x 1/2" x 1", EPD,v1 36 Sash Bottom Lock Spring 38 Glazing Sealant 40 Glass Bead (Lam. Glass) I► - 2.002" .062" .501" .869" .012" .062" J OFLANGE FRAME HEAD 6063-T6 ALUMINUM 2.056" 3.225" .050" s7s•, .oso"-� 1.125" 1 �- .oso'• J___2.os6" 5 INTEGRAL FIN FRAME SILL 6063-T6 ALUMINUM .osz•-'- nP1.00 1.763" 093" 1 9 HD FIXED MEETING RAIL 6063-T6 ALUMINUM .050" 8 .050" - .498" T .050" I Imo- 2.048" - OFLANGE FRAME SILL 606346 ALUMINUM 2.590" .238" T1j f .osz" 2.000" soa• L 062" .050" FRAME JAMB OFLANGE 6063-T6 ALUMINUM -1 .050" 1.121"1 r -►I ,� f .062" 062 1.999" .oso" 971 .050" 6 INTEGRAL FIN FRAME JAMB 6063-T6 ALUMINUM .062" 1.370" O50"- r i -�{ .926" ��- 10 SASH SIDE RAIL 6063-T6 ALUMINUM 7 T I 1 807" 1.2I29" .osz" -� .osz" .926" 7 SASH BOTTOM RAIL 6063-T6 ALUMINUM .865" .874" .062" 11 SASH BOTTOM LOCK RAIL 6063-T6 ALUMINUM SH WINDOW INSTALLATION I TROSOWSKI MATERIALS 09/20/17 ReWefon: V. By: Rev. Dote: ADDED LILTRACON+ ANCHOR JR 08/27/20 Serfea/Akd.1. swim Sheet: DF 119 No, Rev: SH-4100A I NTS 1 4 OF 4 SH4100FLPA E 1.985" .962" 1.125" f '050" 869" osz° .osz" .osz" -� OINTEGRAL FIN FRAME HEAD 6063-T6 ALUMINUM 2.081" .062" 8 SASH TOP RAIL 6063-T6 ALUMINUM \\111111 !!! JCENgF Impact Resistant �� �yyJWindows & Doors p WERE STRONGER'" * ; NO.58705 •, eTm d.. man xLL.n,..9 Tel; .908.09.. I Faa: 909...0.. 993 PREPARED BY LYNN MILLER ` 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 0. STATE OF %��'••,F<OR10P.•'G��� (941)480-1600/ss/.."""•�� CDOORS, \�` '7rf ONI LI I ED LICENSE TOM MAKE I I10 COPIES FOR PERMITnec. A. LYNN MILLER, P.E. REGISTRATION#29296 P.E.#58705