HomeMy WebLinkAboutNavarro WP Letter40 .11i1�i'�li'61NEERING 1���1F�C.. PROFESSIONAL STRUCTURAL CONSULTANTS 850 NW Federal Hwy, Suite 172, Stuart, FL 34994 Voice: (772)223-9883 Cell: (772)215-4080 March 10, 2022 Mr. Bill LaPrade c/o The Glass Professionals 3570 SE Dixie Hwy Stuart, FL 34997 Re: Window Replacement - Nivarro Residence, 9940S. Ocean Dr., Unit # 508, Jensen Beach, FL 34957 Dear Mr.LaPrade; I have reviewed the required wind load requirements for the replacement window at the above referenced location. I have prepared the following report for your use. The replacement window is PGT SH5000 (Single Hung 5500) with NOA No. 20-0401.03. The provided allowable design pressures are +70 psf and -I 10 psf. The window has a masonry opening of 37.75" x 50.625" or 1,911.1 sq. inches or 13.3 square feet. The applied required design pressures for a 10 square foot (conservative) opening (per the attached Wind Load Calculator) are hi -lighted in the table. The required applied design pressures are +/- 59.1 psf. This window is more than adequate to withstand the expected pressures and meets or exceeds the requirements of the 2020 Florida Building Code (FBQ 6"' Edition and ASCE 7-16. If you have any questions or concerns, or if I can be of any future service, please do not hesitate to contact me. Respectfully submitted, (51� �M- T. Stiles Peet. P.E., S.E. ES AFDigitally signed C'% ``�5•� by Timothy * No. aszoo ':* : Stiles Peet _ * �= Date: ��•• STATE OF I'Z0R\'QP.'��` 2022.03.10 i'FSS'O'NA;E?G�� 10:44:49-05'00' P:\2022\22-019 GLASSPRO GENERAL (20-061)\22-019.01 NIVARRO\22-019.01 9940 S. OCEAN DR WINDOW CERT.doc 3110/22, 9:36 AM CADDtools Design Pressure results ASCE 7-16 Wind load Program (30.5 Part 3: Building Wall Components and Cladding) Wall Components and Cladding (Mean Roof Height h > 6o ft) Project: NAVARRO Prepared by: TSP of SEG, INC. E-mail: Input: ASCE 7-16 Strength Design Load & Allowable Stress Design Wind Speed = 165 mph Building Exposure = D (Flat Unobstructed areas) Internal Pressure Coefficient GCpi = 0.18 Enclosed Building Kzt = 1.00 Kd = 0.85 Ke=1.00 Mean Roof Height =150 ft Output: Velocity Pressure Exposure Coefficient "Kz max." = 1.54 Per Table 26.10-1, page 268 LRFD uses wind speed Vult = 165 mph Velocity Pressure (qh LRFD) = 91.23 psf = .00256*Kz*Kzt*Kd*Ke *VA 2 lb/ft^2 Per eQ.30.3-1, page 335 ASD uses wind speed Vasd1= 128 mph Velocity Pressure (qh ASD) = 54.74 psf = .002 Kz*Kzt Kd*Ke *VA 2*o.61b/ft^2 LRFD (Load Resists ce ASD (Allowable Stress (Design) Per Figure 30.6-1, Page Factor Design) 8 TributaryCoefficients Area Positive Zone 4& 5 Negative Center Zone 4 Ne ativ Cor er Zo e 5 Positive Zone 4& 5 Negative Center Zone 4 Negativ Co e 5 External Pressure Positiv Negative Negativ Sq Feet psf psf f psf psf p f GCp Center Corner 10 ft2 98.5 -98.5 -180. 59.i -59.1 - 8.4 0.90 -0.90 -1.80 20 ft2 98.5 -98.5 -180.6 9.1 -59.i o8.4 0.90 -0.90 -1.80 5o tt� 90•7 -93.3L -159.9 111 •4 -95.9 10.81 -0.84 -1.57 100a 84.8 -89.4 -144.1 50.9 -53.6 -86.5 0.75 -0.80 -1.40 20o ft2 79•0 -85.5 -128.4 47.4 -51.3 -77.1 0.69 -0.76 -1.23 50o ft2 71.2 -80.3 -io7.7 42.7 -48.2 -64.6 0.60 -0.70 -i.00 Least Width = 85 ft a = 8.5 ft (Zone 5) lo% of least width but not less than 3 ft. Presented by CADDtools.com hftps://caddtools.com/CTcalculatel6.php 1/2