Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProduct Approval Panel WallsFlorida Building Code Online
Page 1 of 3
U
Business o Professional Regulation
r:
Florida Departments BCIS Home I Log In User Registration Hot Topics Submit Surcharge i Stats & Facts Publications FBC Staff BCIS Site Map Unks Search
Busines
Professi I*USER:Product Approval
Public User
Regulation
Product Approval Menu > Product or Application Search > Application Llst > Application Detail
FL # FL13192-R3
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer James Hardie Building Products, Inc.
Address/Phone/Email 26300 La Alameda
Ste. 250
Mission Viejo, CA 92691
(909)349-2927
pingsheng.zhu@jameshardie.com
Authorized Signature Pingsheng Zhu
pingsheng.zhu@jameshardie.com
Technical Representative Pingsheng Zhu
Address/Phone/Email 10901 Elm Ave.
Fontana, CA 92337
(909)349-2927
pingsheng.zhu@jameshardie.com
Quality Assurance Representative Pingsheng Zhu
Address/Phone/Email 10901 Elm Ave.
Fontana, CA 92337
(909) 349-2927
pingsheng.zhu@jameshardie.com
Category
Panel Walls
Subcategory
Siding
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
© Evaluation Report - Hardcopy Received
_ Florida. Engineer or Architect Name who developed
Ronald I. Ogawa
- the Evaluation Report
Florida License
PE-24121
Quality Assurance Entity
Intertek Testing Services NA Inc. - ETL/Warnock Hersey
Quality Assurance Contract Expiration Date
01/01/2016
Validated By
John Southard, P.E.
R Validation Checklist - Hardcopy Received
Certificate of Independence
FL13192 R3 COI RIO - Certificate of Indeoendence.odf
Referenced Standard and Year (of Standard) Standard
ASTM C1186
ASTM E330
Year
2007
2002
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Archi
Jod
Equav ASTM C1186HILL,
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtsk%2bGnUu4... 8/27/2015
Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/23/2015
Date Validated 04/30/2015
Date Pending FBC Approval 05/11/2015
Date Approved 06/22/2015
Date Revised 08/17/2015
of Products
Page 2 of 3
FL # Model, Number or Name Description
13192.1 Cemplank Lap Siding fiber -cement lap siding
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL13192 R3 II ER RIO-2553-15 Plank metal wood.pdf
Approved for use outside HVHZ: Yes FL13192 R3 II ER RIO-2557-15 Plank Shingle CMU.Ddf
Impact Resistant: N/A FL13192 R3 II Install CemPlank Sidino.pdf
Design Pressure: N/A FL13192 R3 II NOA 15-0122 04 odf
Other: For use in HVHZ install in accordance with NOA 15- Verified By: Ronald I. Ogawa 24121
0122.04. Created by Independent Third Party: No
Evaluation Reports
FL13192 R3 AE ER RIO-2553-15 Plank metal wood.r) f
FL13192 R3 AF ER RIO-2557-15 Plank Shinole CMU odf
FL13192 R3 AE NOA 15-0122.04.Ddf
Created by Independent Third Party: Yes
13192.2
HardiePlank Lap Siding
fiber -cement lap siding
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL13192 R3 II ER RIO-2553-15 Plank metal woody f
1`1-13192 R3 II ER RIO-2557-15 Plank Shingle CMU odf
FL13192 R3 II Install HardiePlank Siding.pdf
Design Pressure: N/A
FL13192 R3 II NOA 15-0122.04.Ddf
Other: For use in HVHZ install in accordance with NOA IS-
Verified By: Intertek Testing Services NA Ltd.
0122.04.
Created by Independent Third Party: No
Evaluation Reports
FL13192 R3 AE ER RIO-2553-15 Plank metal wood Ddf'
FL13192 R3 AE ER RIO-2557-15 Plank Shingle CMU.pdf
FL13192 R3 AE NOA 15-0122.04.Ddf
Created by Independent Third Party: Yes
13192.3
HardieShingle Individual Shingles
fiber -cement individual cladding shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL13192 R3 II ER RIO-2555-15 Shingle metal wood.pdf
FL13192 R3 II Install HardieShingle Sidina.oddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Intertek Testing Services NA Ltd.
Design Pressure: N/A
Created by Independent Third Party: No
Other:
Evaluation Reports
FL13192 R3 AE ER RIO-2555-15 Shingle metal wood odf
Created by Independent Third Party: Yes
13192.4
HardieShingle Panel
fiber -cement notched shingle panels (straight edge,
staggered edge, half round edge)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL13192 R3 II ER RIO-2555-15 Shingle metal wood pdf
FL13192 R3 II ER RIO-2557-15 Plank Shingle CMU Ddf
Approved for use outside HVHZ: Yes
FL13192 R3 II Install HardieShingle Siding.pdf
Impact Resistant: N/A
Design Pressure: N/A
Verified By: Intertek Testing Services NA Ltd.
Other:
Created by Independent Third Party: No
Evaluation Reports
FL13192 R3 AE ER RIO-2555-15 Shingle metal wood.pdf
FL13192 R3 AE ER RIO-2557-15 Plank Shinole CMU.Ddf
Created by Independent Third Party: Yes
13192.5 Prevail Lap Siding fiber -cement lap siding
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL13192 R3 II ER RIO-2553-15 Plank metal wood.pdf
Approved for use outside HVHZ: Yes FL131 2 R3 11 ER RIO--'-- h' f ,
Impact Resistant: N/A FL13192 R3 II Install Prevail L Si
Design Pressure: N/A FL13192 R3 II NOA 15-0122.0
PJ
Other: For use in HVHZ install in accordance with NOA 15- Verified By: Intertek Testing Ser , ce Lt .
0122.04. Created by Independent Third P y: .
https://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDgtsk%2bGnUu4... 8/27/2015
Florida Product Approval
Cemplank° Lap Siding
• For use inside HVHZ:
o Cemplank Lap Siding fastener types, fastening schedule, and installation
shall be in accordance with the Miami -Dade County Florida NOA 15-
0122.04. Consult the Cemplank product installation instructions on the
follow pages for all other installation requirements.
• For use outside of HVHZ,
o Cemplank Lap Siding fastener types, fastening schedule, and installation
shall be in accordance with Engineering Evaluation Reports RIO-2553-15
or RIO-2557-15. Consult the Cemplank product installation instructions on
the follow pages for all other installation requirements.
n
" Cempla&7_
Lap Siding
INSTALLATION REQUIREMENTS - PRIMED AND FACTORY BUILT COLOR TREATED PRODUCTS EFFECTIVE AUGUST2010
CEDAR ■ BEADED CEDAR ■ BEADED SMOOTH
IMPORTANT: FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND
THE MANUFACTURER'S WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM
PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY._
STORAGE & HANDLING:
Di CUTTING INSTRUCTIONS
Store flat and keep dry and
i
covered prior to installation.
p
Installing siding wet or saturated
may result in shrinkage at buff
joints. Car tanks on
1 Carry edge. P g
Protect edges and corners from
breakage. Themanufacturerisnot
g
responsible for damage caused by
ouTDooRs
1. Position cutting station so that wind will blow dust away from user
and others in working area.
2•Use one ofthe following methods:
a. Best: t. Score and snap
h. Shears (manual, electric or pneumatic)
b. Better: I. Dust reducing circular saw equipped with a
HardiebladeTusaw blade and HEPA vacuum extraction
c. Good: I. Dust reducing circular saw with a Hardieblade saw blade
(only use for low to moderate cutting)
INDOORS
1. Cut only using score and snap, or shears (manual, electric or pneumatic).
2. Position cutting station in well -ventilated area
- NEVER use a power saw indoors
- NEVER use a circular saw blade that does not carry the Hardieblade saw blade trademark
-NEVER dry sweep— Use wet suppression or HEPA Vacuum
improper
storage and
handling of the �
g
product.
Important Note: For maximum protection (lowest respirable dust production), the Manufacturer recommends always using "Best -level cutting methods where feasible.
NIOSH-approved respirators can be used in conjunction with above cutting practices to further reduce dust exposures. Additional exposure information is available
at www.cemboardsiding.com to help you determine the most appropriate cutting method for your job requirements. If concern still exists about exposure levels or you
do not comply with the above practices, you should always consult a quarified industrial hygienist or contact the Manufacturer for further information. SDMI05
GENERAL REQUIREMENTS:
• Cemplank" lap siding can be installed over braced wood or steel studs spaced a maximum of 24" o.c. or directly to minimum 7/16" thick OSB
sheathing'. Irregularities in framing and sheathing can mirror through the finished application.
• Cemplank° lap siding can also be installed over foam insulation/sheathing up to V thick. When using foam insulation/sheathing, avoid over -driving nails
(fasteners),which can result in dimpling of the siding due to the compressible nature of the foam insulation/sheathing. Extra caution is necessary if
power -driven nails (fasteners) are used for attaching siding over foam ins ulationlsheathing.
• Awater-resistive barrier is required in accordance with local building code requirements. The water -resistive barrier must be appropriately installed with
penetration and junction flashing in accordance with local building code requirements. The manufacturer will assume no responsibility for water infiltration.
• Install Cemboard® products with a minimum 6" clearance to the finished grade on the exterior of the building or in accordance with local building codes
if greater than 6" is required (fig. 3).
• Maintain a 1"- 2" clearance between Cemboard products and roofs, decks, paths,
steps and driveways (figs. 4, 5 & 6). Figure 1 Double Wall Single Wall
• Maintain a 1/4" clearance between Cemboard products and horizontal flashing (fig. 7). Construction Construction
• Ensure gutters have end caps. Maintain a minimum 1" gap between end caps and siding water -resistive barrier 24" o.c. max. let -in bracing
& trim (fig.8). ose heathing
• Install kickout flashing at roof -wall junctions (fig. 9).
• Adjacent finished grade must slope away from the building in accordance with local
building codes - typically a minimum of 6" in the first 10'.
• Do not install Cemboard products, such that they may remain in contact with
standing water.
Cemplank" lap siding must be installed on vertical wall applications only.
DO NOT use stain on Cemboard products.
INSTALLATION: JOINTTREATMENr
(Required for Factory Built Color Finish, Recommended for Primed product)
It is not recommended to use caulk at field butt joints.
Figure 2 water -resistive
barrier
from
edge
install planks in
moderate contact
Install factory finished edges together at butt joints.
If only nailed to sheathing, plank can be a maximum 9-1/4" wide and must be face nailed at 12" o.c. with 0.09"
shank x 0.221' HD x 1.5" long corrosion resistant nails.
"As required by local building code 'Apply caulk in accordance with caulk manufacturers written application instructions.
0 o fastener
Install a 1 1/4' starter strip to
° o ensure a consistent plank angle
�O o
leave appropriate gap between
planks and trim, then caulk —
WARNING: AVOID BREATHING SILICA DUST
Cemboard" products contain respirable crystalline silica, which is known to the State of California to cause cancer and is considered by [ARC and NIOSH to be a cause of cancer from some occupational
sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. Some studies s!Mgest
smoking may increase these risks. During installation or handling: �1) work in outdoor areas with ample ventilation; (2) use fiber cement shears for cutting or, where not feasible, use a Hp ieblgde avy
blade and dust -reducing circular saw attached to a HEPA vacuum; O warn others in the immediate area; (4) wear a propedy-fitted, NIOSH-approved du res;ds
(e. 9 g
applicable government regulations and manufacturer instructions to further limit respirable silica exposures. During clean-up, use HEPA vacuums or w c e u me- ne r e ' o
information, refer to our installation instructions and Material Safety Data Sheet available at www.cemboardsiding.com or by calling 1-877-236.7526. FA �ADTO UR RNS ,AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH.
? ttM.CEM1802111Pt/4 9108
-CLEARANCES
South
Install siding and trim products in
Maintain a 1"- 2"
compliance with local building code
clearance between
requirements for clearance between the
Cemboard® products and
bottom edge of the siding and the
paths, steps and
adjacent finished grade. Figure 3
driveways.
stud
water -resistive
barrier
Figure 4
L P
concrete
foundation
p
Cemplanke
8 ml lap siding
Maintain a 1/4" clearance
between the bottom of
Cemboard products
and horizontal flashing.
Do not caulk gap.
Figure 7
�— siding
Do not 114' gap
sidin,
Caulk
a4
flashing
Maintain a minimum 1" gap
between gutter end caps and
siding & trim.
Figure 8
gutter and end cap
FASTENER REQUIREMENTS"
fascia
Blind Nailing is the preferred method of installation for all
Cemplane lap siding products
BLIND NAILING
Maintain a 1" - 2" clearance
between Cemboard products
and decking material.
Figure 5
siding water
resistive
barrier
deck material
At the juncture of the roof and vertical
surfaces, flashing and counterflashing
shall be installed per the roofing
manufacturer's instructions.
Provide a 1" - 2" clearance between the
roofing and the bottom edge of the
siding and trim. Figure s
/ 1"-2"
gashing
Figure 9 f,
,•,"'.
KICKOUT FLASHING
/�
Slepgashlm� /`' `, ' ,. -
Because of the volume of water that can pour
•
Seg- g herin,� ' ,�E.
}p
down a sloped roof, one of the most critical
mega
flashing details occurs where a roof intersects
a sidewall. The roof must be flashed with
ek adtienn
� �1' a esmemolaae�
step flashing. Where the roof terminates,
q a
install akickout to deflect water away from
f,
the siding.
Da°cage
�ousemp
It is best to install a self -adhering membrane
on the wall before the subfascia and trim
boards are nailed in place, and then come
back to install the kickout.
Figure 9, Kickout Flashing# To
prevent water from dumping behind the siding
and the end of the roof intersection, install a "kickout" of sufficient length and
angle to direct the water running
down the roof away from the siding.
Nails - Wood Framing
• Siding nail (0.09" shank x 0.221" HD x 2" long)
• 11 ga. roofing nail (0.121" shank x 0.371" HD x 1.25" long)
Screws - Steel Framing
• Ribbed Wafer -head or equivalent (No. 8 x 1 1/4" long
x 0.375" HD) Screws must penetrate 3 threads into metal framing.
Nails - Steel Framing
• ET & F Panelfast® nails or equivalent
(0.10" shank x 0.313" HD x 1-1/2" long)
Nails must penetrate minimum 1/4" into metal framing.
OSB minimum 7116"
• 11ga. roofing nail (0.121" shank x 0.371" HD x 1.75" long)
• Ribbed Wafer -head or equivalent (No. 8 x 1 5/8" long x 0.375" HD).
stud 24" Figure 10
O.C. max.
water -resistive Minimum overlap
barrier o, for Both Face
and Blind Nailing
blind nail
i a min. 11/4"
0 overlap
i f
I water -resistive
1 1/4" min. barrier
overlap
Face Nailing should only be used where required for high wind areas and must not be
used in conjunction with Blind Nailing
FACE NAILING
Nails - Wood Framing
• 6d (0.113" shank x 0.267" HD x 2" long)
• Siding nail (0.09" shank x 0.221" HD x 2" long)
Screws - Steel Framing
• Ribbed Bugle -head or equivalent (No. 8-18 x 1-5/8" long x
0.323" HD) Screws must penetrate 3 threads into metal framing.
Nails - Steel Framing
• ET & F pin or equivalent (0.10" shank x 0.25" HD x 1-1/2" long)
Nails must penetrate minimum 1/4" into metal framing.
OSB minimum 7/16"
• Siding nail (0.09" shank x 0.221" HD x 1-1/2" long)*
stud
Figure 11
24"
O.C. max.
I I
I _
I _ — C
3/4"-1
"
Loo
face nail
Laminate sheet to be removed immediately after installation of each course for Factory Built Color products.
water -resistive
barrier
1 1/4" min.
overlap
t The illustration (figure 9) and associated text was reprinted with permission of THE JOURNAL OF LIGHT CONSTRUCTION. For subscription 1PA9
visit www.jlconline.com.
' When face nailing to OSB, planks must be no greater than 91/4" wide and fasteners must be 12" o.c. or less.
"Also see General Fastening Requirements.
it nndn _ e:.n a.
-� South
GENERAL FASTENING REQUIREMENTS
Fasteners must be corrosion resistant, galvanized, or stainless steel.
Electro-galvanized are acceptable but may exhibit premature corrosion.
The manufacturer recommends the use of quality, hot -dipped galvanized
nails. The manufacturer is not responsible for the corrosion resistance of
fasteners. Stainless steel fasteners are recommended when installing
Cemboard® products near the ocean, large bodies of water, or in
very humid climates.
PNEUMATIC FASTENING
Cemboard products can be hand nailed or fastened with a pneumatic
tool. Pneumatic fastening is highly recommended. Set air pressure so
that the fastener is driven snug with the surface of the siding. A flush
mount attachment on the pneumatic tool is recommended. This will
help control the depth the nail is driven. If setting the nail depth proves
difficult, choose a setting that under drives the nail. (Drive under driven
nails snug with a smooth faced hammer - Does not apply for installation
to steel framing).
• Consult applicable code compliance report for correct fasteners type and
placement to achieve specified design wind loads.
• NOTE: Published wind loads may not be applicable to all areas where
Local Building Codes have specific jurisdiction. Consult the manufacturer's
Technical Services if you are unsure of applicable compliance documentation.
• Drive fasteners perpendicular to siding and framing.
• Fastener heads should fit snug against siding (no air space). (fig. A)
• Do not over -drive nail heads or drive nails at an angle.
• If nail is countersunk, caulk nail hole and add a nail. (fig. B)
• For wood framing, under driven nails should be hit flush to the plank with a
hammer (For steel framing, remove and replace nail).
• Do not use aluminum fasteners, staples, or clipped head nails.
Snug
('asCountersunk,
Flush
®
Caulk il
add nail
do not under
Do NOT
Figure A
Figure B
drive nails
STAPLE
CAULKING PAINTING
For best results use an Elastomeric Joint Sealant DO NOT use stain on Cemboard products.
complying with ASTM C920 Grade NS, Class 25 or Cemboard products must be painted within 180
higher or a Latex Joint Sealant complying with ASTM days for primed product and 90 days for unprimed.
C834. Caulking/Sealant must be applied in accordance 100% acrylic topcoats are recommended.
with the caulking/sealant manufacturer's written Do not paint when wet. For application rates refer to
instructions or ASTM C1193. paint manufacturers specifications.
Back -rolling is recommended if the siding is sprayed.
FACTORY BUILT COLOR TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE
• Touch up nicks, scrapes and nail heads using the Factory Built Color technology touch-up applicator. Touch-up paint should be used sparingly.
If large areas require touch-up, replace the damaged area with new Cemplank® lap siding with Factory Built Color technology.
• Laminate sheet must be removed immediately after installation of each course.
• Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are available from your Factory Built Color product dealer.
• Treat all other non -factory cut edges using the Factory Built Color technology edge coaters, available from your Factory Built Color product dealer.
PAINTING CEMBOARDO SIDING AND TRIM PRODUCTS WITH FACTORY BUILT COLOR TECHNOLOGY
When repainting Factory Built Color products, the manufacturer recommends the following regarding surface preparation and topcoat application:
• Ensure the surface is clean, dry, and free of any dust, dirt, or mildew
• Repriming is normally not necessary
• 100% acrylic topcoats are recommended
• DO NOT use stain or oillalkyd base paints on Cemboard products
• Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature
COVERAGE CHART/ESTIMATING GUIDE
Number of 12' planks, does not include waste
COVERAGEAREA
LESS
OPENINGS SQ
It SQ =100 sq.ft.)
(exposure)
51/4
4
CEMPLANK®LAP SIDING WIDTH
61/4 71/4 71/2 8 81/4
5 6 61/4 6 314 7
91/4
8
91/2
8114
12
10 314
1
25
20
17
16
15
14
13
13
9
2
50
40
33
32
30
29
25
25
19
3
75
60
50
48
44
43
38
38
28
4
100
80
67
64
59
57
50
50
37
5
125
100
83
80
74
71
63
63
47
6
150
120
100
96
89
86
75
75
56
7
175
140
117
112
104
100
88
88
65
8
200
160
133
128
119
114
100
100
74
9
225
180
150
144
133
129
113
113
84
10
250
200
167
160
148
143
125
125
93
11
275
220
183
176
163
157
138
138
102
12
300
240
200
192
178
171
150
150
112
13
325
260
217
208
193
186
163
163
121
14
350
280
233
224
207
200
175
175
130
15
375
300
250
240
222
214
188
188
140
16
400
320
267
256
237
229
200
200
149
17
425
340
283
272
252
243
213
213
158
18
450
360
300
288
267
257
225
225
167
19
475
380
317
304
281
271
238
238
177
20
500
400
333
320
296
286
250
250
186
This coverage chart is meant as a guide. Actual usage is subject to variables such as building design. The manufacturer does not assume responsibility
for over or under ordering of product.
RECOGNITION: In accordance with IMES Legacy Report NER-405, Cemplank° lap siding is recognized as a suitable alternate to that specified in: the BOCA National Building C 999, e,1997-5 nd
Building Code, the 1997 Uniform Building Code, the 1998 International One -and Two -Family Dwelling Code, the 2003International Building Code, and the 20031nte ���III d d n T
Family Dwellings. Cemplank° lap siding is also recognized for application in the following: City of Los Angeles Research Report No. 24862, State of Florida listing 9 n Flo a o. 7 0
U.S. Dept of HUD Materials Release 1263c, Texas Department of Insurance Product Evaluation EG23, City of New York MFA 223.93-M, and California DSA PA-01 . sho d also a ed or
additional information concerning the suitability of this product for specific applications. ig
- ' South
© 2008 JHIF B.V. All rights reserved. TM, sM, and ® denote Additional Installation Information,
trademarks or registered trademarks of JHIF B.V. Warranties, and Warnings are available at
www.cemboardsiding.com
MIAM1-DAD . 1VIIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONO1MIIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.minmidade.gov/economy
James Hardie Building Product, Inc.
10901 EInt Avenue
Fontana, CA 92337
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit
APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail
Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details
Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the
manufacturer, signed and sealed by Ronald I.Ogawa, P.E., bearing the Miami -Dade County Product -
Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade
County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING:,A: permanent label with the manufacturer's name or logo, Plant City, Florida, and the
following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product Control
Approved" is to be located on each siding plank or panel and per FBC 1.710.9.2 and 1710.9.3 on soffit
panels.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in thb
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal ofNOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided -to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA. # 13-0311.07 and consists of this page 1 and evidence page E-1, as well as
approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
•IA No. 15-0122.0
APP80YE0 ' / '•��Expi
App
Py
James Hardie Buildinn Products, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS "Submitted under NOA # 13-0311.07"
I. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel;
HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel;
Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated
04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. Ogawa,
P.E.
B. TESTS "Submitted under NOA # 13-0311.07"
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit
and HardiePanel, prepared by Intertek Testing Services NA LTD, Test Report No.
100733361COQ-004, dated 08/24/2012, with revision 1 dated 04/25/2013, signed and
sealed by Rick Curkeet, P.E.
"Submitted) under NOA # 02-0729.02"
Laboratory Report Test
Date
Signature
2.
' ATI-16423-1 PA 202 & 203
03/18/96
A. N. Reeves P.E.
3..
ATI 16423-2 PA 202 & 203
03/18/96
A. N. Reeves P.E.
4.
ATI 16423-3 PA 202 & 203
03/18/96
A. N. Reeves P.E.
C. CALCULATIONS
1.
None.
D. QUALITY ASSURANCE
1.
Miami -Dade Department of Regulatory and Economic
Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 5th edition (2014) FBC issued by Ronald
I.Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald I.
Ogawa, P.E.
. 03 /3oJ�015 .
Carlos M.._ Utrera, P.E.
Product Control Examiner
NOA No.15-0122.04
Expirat' te• ay 0 tt
Appro e: Aril ,
E-I
1
WALL
Aft
No
DF-TAIL A
WALL LENGTH SEE
Stud Spacing at 16" O.C. DETAIL A
ate_ i I I �-
OF
I Nails at 16" O.C. (typ.)
3/8" Minimum Edge Distance
Sheathing fastener, as described in
Note 1
Panel fastener, as described in
Note 2
HardiePanel, Cempanel,
Prevail Panel Siding
Water4esistive barrier per
Florida Building Code Section
14042
-�y
15 ply APArated
heathing fastened in
accordance with Florida Building
Code Section 23223
2" X 4" S-P-F Wood Studs
The wag and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
`
518" thick 15 ply APA rated
plywood sheathin3 in
accordance with Florida
w
BtnWM Code Section
2322.3
�'
Water%resWdve
re
barrier per Florida
��
Building Code
$
Section 1404.2
X X 4' S-P-F
'
Wood Studs
PRODWI DE_s—CRlYiloN
liardiepanel®, CempaneW, &
Prevail® Panel Siding materials are
nonasbestos fiber -cement products
tested in accordance with ASTM
C1186 Grade II, Type A and meeting
the requirements of the Florida
Building Code.
t?�1NEL_DIM16N_S_LOT-4$
Width Length Thidmess
4 8,9,10' 5116"
DE00I MR—ES_SURE RATING
Installation Design Pressure
Wood Studs -76 psf
HardiePariel, Impact Resistant-•
$j CTQN B-B Cempar,el, Planks installed over 5/S" thick 15 ply
Prevail Panel APA rated plywood sheathing
Siding
HARDIEpgt�t CEMPATIQ, PREVAIL PAPIEf� SyOf[1G 1NSTALL1�nQNJ�E�A��?
• All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's
installation recommendations, and the applicable sections of the Florida Building Code.
• Wood studs where Harc iePanel, Cempanel, Prevail Panel Siding will be installed shall be
designed by an Engineer or Architect per the Florida Building Code and the requirements of this
N.OA
[Note 13 510" thick 15 ply APA rated plywood sheathing shall be attached to the studs in
accordance with Florida Budding Code Sedion 23223. sheathing supported
■ The siding panels shag be installed over SIT thick 15 ply APA rated plywood
by a minimum of 2"X4" S-P-F wood studs spaced a maximum► of 16" O.C.
• [Note 7j The siding panel fastener shall be a Z long, 0.223" head diameter, 0.092" shank
diameter, corrosion resistant siding nail; the fasteners shaft be spaced at 6" O.C. at panel edges
and intermediate studs; the fasteners shall be driven through the SIB' thick / 5 ply APA rated
plywood sheathing into wood studs located at 16, O.C.
Fasteners shall have a minimum edge distance of 318" and a minimum clearance of X'from \
comers.
HARDIEPANEI, CEMPANEL, PREVAIL PANEL
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
.lames Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
DMNO
Fax 909.427-0634 A PNL�SH
OFF
Creator. E Gonzales SCALE 112" = V-o� Date: 4 24f2013 �OF
Fastener Spacing per Florida_ �J ciana�ng
Building Code Section 2322.3 16.00in.
Framing
1 �C -
•teReLTl�'vt� Fastener Spacing per Florida Sheathing
emr�giaQ,�6t�tba>F7ae� Building Code Section 2322.3
�. .� �
PtroductCaaMd tiller/I//
aassCOWPI)ft with the Fk6uI• �`
**` �{
f -a STA fl AnyBy!
�J
' I�a�aa�ana •• I • I � �p��. F� p. ��
FRAMING
■ NOMINAL 2" X 4" S-RF WOOD STUDS 16" O_C. FASTENED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
WITH-3-1/2' 16d COMMON NAILS (2 PER TOP AND NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) \
BOTTOM CONNECTION)-�
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
;SHFJ�TIi[NG
■ NOMINAL 5/8" THICK/5 PLY APA RATED PLYWOOD HARDIEPANEL, CEMPANEL, PREVAIL PANEL
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA INSTALLATION DETAILS WOOD STUD CONSTRUCTION
BUILDNG CODE SECTION 2322.3
CI:ADD1 K-G ,fames Hardie Building Products, Inc.
■ THE PANEL IS FASTENED NTH T LONG, 0.223 HEAD 10901 Elm Avenue
DIAMETER, 0.092'•' SHANK DIAMETER, CORROSION s
RESISTANT SIDING NAILS, PLACE NAILS 5' O.C. AT Fontana, CA 92337
PANEL EDGES AND INTERMEDIATE STUDS Phone: 909.356-6300 sty rscm No owe No REV
Fax 909-427-0634 A PNL-PLKSOFF 1
Creator E. Gonzales 'scALE V = T-0" • Date: 4/24/2013 SHM-7 2 OF 12
ihb
WALL.
B
.D_IA!L-6
tba-Florida
ALL LENGTH
Stud Spacing at 16" O.C.
116
3/8" Minimum
SEE
DETAIL A
5/V thick / 5 ply APA rated
plywood sheathing fastened
to metal studs as described
in Note t
PRODLf_CT M- REPTiOiQ
HardiePanel®, Cempanel®, & Prevail®
Panel Siding materials are nonasbestas
fiber -cement products tested in
accordance with ASTM C1186 Grade tt,
Type A and meeting the requirements of
the Florida Building Code.
PANEL DtMMFN_S_IOtt-S-
3�/ 1
i No,
1
Water -resistive
barrier per Florida
Width Length Thickness
4! 8,9,10' 5116,
+ ;
zi *
=
Building Code
=_� STATE p
N
Section 14042
bESIG_N__PRES_S_ii_� $A_%ING
oB
-.�O ��• F(Q�10
209a, 3.5/8"X I-M"
Installation Design Pressure
Metal Studs -104
i
I
psf
��
Metal Cstud
_
�j�'••......-�:
HardiePanel,
impact Resistant-
,.
Panel installed over 618 thick / 5 ply
.S.i~G.IJ.ot�Lf�B
Cempanel,
APA rated plywood sheathing
Distance
Nalis at t3" O.C. (typ.)
Prevail Panel
Siding
Sheathing fastener, as
described in Note 1.
Panel fastener, as described in
�- Note 2
HardiePanel® Siding
Water -resistive barrier per
Florida Building Code Section
1404.2
-Y-�� 5/8" thick 15 ply APA rated
plywood sheathing fastened
to metal studs as described
in Note 1.
20ga, 3-5/8"X 1-5/8".Metal C-stud
The wall and soffrt frames are to be designed
by the Architect or Engineer of Record in
compHancewiththe Florida Building Code.
HAI�DIEPAI�CENiPANE1�PEEV��4PANEL SlD[NG II�SJALL �iTIO[1 DE_fA1LS
■ All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's
installation recommendations, and the applicable sections of the Florida Building Code.
Metal studs where HardlePanet, Cempanel, Prevail Panel Siding will be installed shall be
designed by an Engineer or Archited per the Florida Building Code and the requirements of this-
N.O.A.
■ [Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at 6"00
at panel edges and all intermediate supports using a No.8-18, 0.315" head diameter X 1AM long
bugle head screw
• The siding panels shall be installed over 518" thick 15 ply APA rated plywood sheathing
supported by a minimum 209a, Nominal 3-51W X 1-518" Metal C-studs spaced a maoamum of 16"•
O.C.
[Note 2] The siding panel fastener shall be a minimum No- &48, 0-315" head diameter X 1-5/8°
long`' ribbed bugle head screw ("or screw shall have at least 3 full threads penetrating.metal
framing); the fasteners shall be spaced at 6" O.C. at panel edges and intermediate studs; the
fasteners shall be driven through the 518" thick 15 ply APA rated plywood sheathing into metal
studs located at 16" O.C.
■ Fasteners shall have a minimum edge distance of 318" and a minimum clearance of 2" from
comers.
Creator. E. Gonzales
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
A
SCALE' 1/2" = T-0"
PNL-PLK-SOFF I 1
Date: 424/2013 ISHEET 3 OF 12
1 s.oain. �••-
i
I I
i I -I
I
T
6.00in.
. DStODl1CF��
�• �y�g wiith the l�andn
prto f' �3rl4r
II
I' I
II
I.1
6.00in. I I
I
II
I
I•I
II
pjWMCr gEYlS®Flmis
Aoo.vte� Nu f5''d ?Z _
kDM
F�2gMIN�G,
■ NOMINAL 20 GAUGE 3-50 X 1-5/8" STEEL STUDS 16" O.C.
FASTENED WITH 518" WAFER HEAD SCREWS (2 PER TOP
AND BOTTOM CONNECTION)
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
MKQ
9 -- NOMINAL 5/8" THICK 15 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6" OC AT PANEL
EDGES AND INTERMEDIATE SUppORTS USING A
N0.8- 8 0315A1 HEAD DIAMETERX I-1W LONG BUGLE
HEAD-SCREW
��s,
e LADDING
h PANEL IS FASTENED WITH NO. 8-18, 0.3'15' HEAD
g.
DIAMETER X 1-6/8' LONG CORROSION RESISTANT
RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT
LEAST 3 FULL THREADS pENETRATING THE METAL
FRAMING), PLACE SCREWS 6" O-C. AT PANEL EDGES
AND INTERMEDIATE STUDS
Cladding
Framing
I
II
Sheathing
!I
I•I
II
I I I
I,I I.I
I I I 111f1l"/�lii���
I•I !.l ,��� S"
! I 'o. 121
I •a STATE OF
SION AL ,
FOR METALAND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVrTy LOAD ARE NOT PARTF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS OR THESE NLOADS)
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 EUn Avenue
• Fontana, CA 9M7
$� FSCM NC DING NO
?hone: 90956-6300 PNL PLKSOFF
Fa7c 909-427-0634 A
Creator. E. Gonzales SCALE 1"=1'-0" pate:4/24/2013 sHEEf 4 OF 12
7
i
s
MD
LENGTH
DEj:AJU Sheathing fastener, as
I— described in Note 1
Siding fastener, as
described in Note 2
HardiePlank,
Cempiank, Prevail
Lap Siding
/ / Water -resistive barrier
per Florida Building
f Code Section 1404.2
518" thick/5 ply APA rated
plywood sheathing fastened
.in accordance with Florida
Suilding Code Section
2322.3
2" X 4" S-P-F Wood Studs
The wall and soffit frames are to be designed
'by the Architect or Engineer of Record in
nmmnrianna m ith the Florida Building Code.
sE99
DEi'AJL A
�oflucT ni=scg�pnOu
HardiePlanmplanfc®. &
Prevail® Plank Lap Siding materials
m"thick! 5 ply APA
are nonasbestos fiber -cement
Products tested in accordance with
rated plywood
ASTM C1186 Grade it, Type A and
sbeathing in
'a=rdanm
meeting the requirements of the
with
Florida Building Code.
Flodda BUdding Code
5ec6on 2322.3
PANEL P- ME.N_AM M
Water4eezfi%m
Width Length Thickness
barrierperFlkodda
59-112" 12' 5/16'
Bunding Code
Section 14042
pESLGN PRESSUF_kF RM1!NG
Z" X 4" S-P-F
Wood Stds
L.ap Siding
1- W {all X 5/16"
thick starter strip
Installation Design Pressure - -
Wood Studs -92 psf
impact Resistant
Planks installed over 618" thick / 5 ply
APA rated plywood sheathing
}igLtQ1�PLA IFOCI �NIPL�NFC� p$EYA_ �4LAI' $1D_I�IG,NS CAt-L gTiON P-JE-TA_ TuS
M All installation shag be done in conformance with this Notice of Acceptance, the manufacturer's
installation recommendations, and the applicable sections of the Florida Building Code.
■ Wood studs where liardiePlank, Cempiank, Prevail Lap Siding will be installed shall be designed by an
Engineer ar Architect perthe Florida Building Code and the requirements of this N.OA
• 4� 5/8" thick 15 ply APA rated plywood sheathing shall be attached to the studs in accordance
lTlote
with Florida Building Code Section 2322.3.
■ Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4" wide
laps at the top of the plank such chat the exposure area of each plank is 5 8-1l4" vertically.
j jNote t 'fie siding fastener snail be a 2-1/2° long, 0.223" head diameter, 0.092"shank diameter,
corrosion -resistant siding nail; The siring is fastened S 8-1/4" O.C. vertically and 16" O.C. horizontally;,
fasteners are driven into wood studs through 5/8"thick / 5 ply APA rated plywood sheathing, g
are placed in the overlapping area approximately 3/4" from the bottom edge of the overlapping plank.
Vertical joints shall be placed over sZlids.
The planks shall be installed over 518" thick / 5 ply APA rated plywood sheathing supported by a
minimum of Z X4" S-P-F wood studs spaced a maximum of 16" O.C.
• Fasteners shall have a minimum edge distance of 3W.
Creator. E. Gonzales
HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
James Hardie Building Product.s, lno.
10901 Elm Avenue
Fontana, CA 92337
A , I PNL-PLK-SOFF
1!E" -1'-0" 1 - Date: 4124/2013 4sHEEr 5 OF 12
Fasten: Spacing per Florida
Building Code Section 2322.3 16 in. O Cladding
�— - Framing
"" "—"-' '— •'"M Fastener Spacing per Florida
P Sheathing
Building Code Section 2322-3
_...... _ _
0.75n .'
....--__..__. ..............
f1R0wCrREVLqM
as wvnp1ybSw1&tb&fk6ft
07 ....._.-----...._._--•—et,�}``
Ts3ode Psndud Caehait a �o�pi�ring wiri►�e i7aids ���
erg INo. 21
By L ESTATE OF �
. sie P�adirt CaMid
FRAMING
■ NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED
WITH 3-1/2" 16d. COMMON NAILS (2 PER TOP AND IV
BOTTOM CONNECTION) 'FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND �il�{Y�LOAD ARE ._
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
BY THE ARCHITECT OR ENGINEER OF RECORD IN
i COMPLIANCE WITH THE FLORIDA BUILDING CODE
THING
NOMINAL 50, THICK / 5 PLY APA RATED PLYWOOD
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
!111�BUILDING CODE SECTION 2322.3 INSTALLATION DETAILS WOOD STUD CONSTRUCTION
PLANKS.OVERI.AP 1-11,V James Hardie Building Products, Inc.
THE EXPOSURE ISs8-19' 10901 Elm Avenue
THE PLANKS ARE FACE NAILfiD WITH 2-112" LONG, 02W Fontana, CA 9=7
HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSIOK.im
RESISTANT SIDING NAILS, -PLACED 3/4" UP FROM THE Phone: 909-356-6300 SUZE FscM NO DING NO Pv
BOTTOM EDGE OF THE PLANKAT EACH STUD LOCATION Fax W9_427-0634 A PNL-PLK-SOFF 4
Creator: E Gonzales SCALE 1" = 1'-(3" Date: 4/24)2013 SHEET 6 OF 12
wdLL
at 16,
3/4" Minimum
r"11-271ff71
r'-,1
SEE
TAILA
W thick 15 ply APA
r krated plyumod
sheathing fastened
to metal studs as
described in Note 1
Water -resistive
barrier per Florida
Building Code
R Section 14042
PRODUCT DISC IPTiQ{ri
HardiePlankS, Cemplank®, and
Prevail® Plank Lap Siding materials
are nonasbestos fiber -cement
products tested in accordance with
ASTM C1186 Grade 11, Type A and
meeting the requirements of the
Florida Building Code.
PLgNK DEMENSLQNS
Width Length Thickness
59-1/Z+' 12' 5/161•
DadeProdm:Coems! ! ' i iTi : i \20ga, 3-5/S" X 1-5/8" • DESIGN PRESSURE RATING
=i. I C-stud
F ` .Installation Design Pressure '
--.---.-----11_._.____-- �'--------__�)--' G �� -F _ `�•� \ HardiePlank, Metal Studs .92 p
_ `Cern lank Prevail
-►� f t- �� c5's '''•....'.• t lap Siding Impact Resistant -
Distance Nails at 16" O.C. (typ.) .�10NAL Cho 1-11a" ta11 X 5/1 s - Planks installed over 5/8" thick 15 ply
APA rated plywood sheathing
thick starter strip
Sheathing fastener, as
described in Note 1
Siding fastener, as
j described in Note 2
t
l
HardiePlank,
�Cemplank,
/! Prevail Lap Siding
,► ,,�( / Water -resistive
barrier per Florida
Buildng Code
- Section 1404.2
50' thick 15 ply APA rated
plywood sheathing fastened to
metal studs as described in
Note 1
20ga, 3-5/8" X I-WS" Metal C stud
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
liAF2DIFJ?LANK.qEMPLANK. PREVAIL Lf1tP__$IDING INS_fALI.ATION DETAILS-
- Ail installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation
recommendations, and the applicable sections of the Florida Braiding Code.
■ Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an
Engineer or Architect per the Florida Building Code and the requirements of this N.OA
■ [Note 1] 5/8" thick 15 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc at panel
edges and all intermediate supports using a No.B-18, 0.315" head d'rameterx IAA long bugle head screw
■ PIanks shall be applied horizontally commencing from the bottom course of the wall with 1-1W wide laps at
the top of the plank such that the exposure area of each plank is S SAX vertically.
■ [Note 21 The siding fastener shall be a minimum No. 8-18, 0.315" head diameter X 2-114" long{ bugle head
screw over metal studs ("or screw shall have at least 3 full threads penetrating metal framing); The siding is
fastened s 8-1/4" O.C. vertically and 16" O.C. horizontally, fasteners are driven into metal studs through 518"
thick IS ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately 3/4' .
from the bottom edge of the overlapping plank. \
■ Vertical joints shall be placed over studs.
■ The planks shall be installed over 518" thick 15 ply APA rated plywood sheathing supported by a minimum
20ga, Nominal 3-518" X 1-5/8" Metal C-studs spaced a maximum of 16" O.C.
■ Fasteners shall have a minimum edge distance of 3/8".
HARDIEPLANK, CEMPLANI, PREVAIL LAP SIDING
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
SIZE FSCM No I om No
A PNL-PLK-SOFF
Creator. E. Gonzales ISaruE 1/2"=T-0" I Date:4/24/2013 ISHW
7OF12
REV
6.00in.
0.75n
ar com�lyu�ri�[=5elFfori�s
amiwm code
T - ZG � � Boa
58 2Sin.
FE�NE_j1\1_G_
■ NOMINAL 20 GAUGE 3-S/S" X 1-9/8" STEEL STUDS 16"
O.C. FASTENED WITH 518" LONG RIBBED BUGLE HEAD
SCREWS (2 PER TOP AND BOTTOM CONNECTION)
■ THE= WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
* iHEAT8JNG
■ NOMINAL 5/8" THICK 15 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT G' OC AT -PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A
NO.8-18, 0.315" HEAD DIAMETER X 9-114" LONG BUGLE
HEAD SCREW
�CLADDi1VG
1 �PLANKS OVERLAP 1-114"
$ THE EXPOSURE IS 98-1/4"
csf-5rY THE PLANKS ARE FASTENED WITH NO. 8-18, 0.315"
HEAD DIAMETER X 2-1/4• LONG CORROSION -
RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW
SHALL HAVE AT LEAST 3 FULL THREADS
PENETRATINGTHE METAL FRAMING), PLACED 3/4" UP
FROM THE BOTTOM EDGE OF THE PLANK AT EACH
ATI In I nCAT nN
6 in.
Cladding .
• Framing
• 1 6,00in.00 I Sheathing
I- t
i.l Joao' OGAiy '—
REMM
aoe�llyia6 *ft lie F7oriidr
MV
Eaeodoa�c,..rrei • I =STATE OF
p�=gtri;5 i J
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE I
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) 1,
WALL
1
WALL LENGTH
Stud Spacing at 16" O.C.
R y__ I I r
318" Minimum
Nails at 4" O.C.
Distance
ofTrtfastener, as
ascribed in Note 1
HardieSofft, Cemsoffrt
Minimum 2" X 4" S-P-F Wood Studs
The wall and soffit frames are to be
designed by the Architect or
Engineer of Record In compliance
with the Florida Building Code.
SEE
DETAIL A
r
{
2" X 4° S-P-F
Wood Studs
HardieSoM
Cemsoffit
S_lYC�JQN�B.
PODLLC DES9BP'flOi3
HardieSoffitS & Cemsofft& materials are
nonasbestos fiber -cement products tested in
accordance with ASTM C1186 Grade 11, Type A
and meeting the requirements of the Florida
Building Code.
SOFFLT DJMENSION$
Width Length Thickness
N V 114,
P-�$iG_N PRF,SgLugEU3ATJ IZ
Installation Design Pressure
Wood Studs -70 psf
PROD(=REVISES?
W complying webs me Fh ide
aultdiog Go&
Aoxpte e„ `G Dab
E3,
jD3ftPM&'d C.ft'l
i�
Na_ 4 21.
STATE OF
�iAF�p�S_QEFiT�c�i.N_S_OFFIY„p_gN.�L_�L�STA.L,LAX'Jo�lp1?AU�
= An installation shall be done in conformance with this Notice of Acceptance, the manufacturer's
installation recommendations, and the applicable sections of the Florida Building Code.
= Wood studs where HardieSoffit, Cemsoffit will be installed shall be designed by an Engineer or
Architect per the Florida Building Code and the requirements of this N.OA
■ The soffit shall be installed over minimum 2"X4" S-P-F wood studs spaced a maximum of 16" O.C.
= INote 11 The soffit fastener shall be a 2" long, 0.223" head diameter, 0.092" shank diameter,
corrosion resistant siding nail; the fasteners shall be spaced at 4" O.C. at panel edges and
intermediate studs; the fasteners shall be driven into wood studs located at 16" O.C.
= Fasteners shall have a minimum edge distance of W and a minimum clearance of 2" from comers.
Creator. E. Gonzales
HARDIFSOFFIT, CEIVISOFFIT PANEL
INSTALLATION DETAILS WOOD STUD CONS-MUCTION
FSCM nn
James Hardie Building Products, Inc,
10901 Elm Avenue
Fontana, CA S2337
PNL-PLK-SOFF
1/2" = 1'-0" 1 Date: 4/24r2013 Isr+EE7 9 OF 12
• 4.001
pRdR crREvzsm rtoDUcrR vlSw ,it
,. 'bv� am Flora. ffi cowpb iW wig dwF� ���
brio �' A� �Wp4v Coft • d- .07
D�isaOioa 37aa+e . ! �' ' f
kf" i Pnvtwo Casual $!► iiaaa i?.tie p�:t Coold
ER&M(NG
NOMINAL 2" X V S-P-F WOOD STUDS 16" O.C. FASTENED
WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM
CONNECTION)
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY
THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE
7HE FLORIDA BUILDING CODE
WING
�SoiF IS FASTENED WITH 2° LONG, 0223" HEAD
DIMETER, 0.092" SHANK DIAMETER, CORROSION
STANT SIDING NAILS, PLACE NAILS 4' O-C. AT PANEL
tDGES AND INTERMEDIATE STUDS
,
Cladding
r_ Framing'
iA
v _
STATE OF =
Z
/0NA%-Ee � V
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
i
WALL
WALL LENGT" ' --= Et= i SPFZO_DIJt _T BESCREP��Ot
Stud Spacing at 16" O.C. DETEE HardieSof S & Cemsoffit0 materials
are nonasbestos fiber -cement products
tested in accordance with ASTM C1188
^ -----,- =--•-- }- - —=- - ---,- --'•--- - - - - - - - '�' 0 1 Grade 11, Type A and meeting the
! —I.I - J requirements of the Florida Building
Code.
B
Nails at 6' O.C. (typ.
3/8" Minimum Edge Distance
Soffit fastener, as
described in Note 1
HardieSoffit, ' Cemsoffit
20ga, 3-518"4 1-W Metal G-stud
j The wall and soffit tames are to be
L— designed by the Architect or Engineer
of Record in compliance with the
FlcHda.Building Code.
[.
2092, 3-518" X 1-518"
S� -D SIONS
tat C-stud
Width Length Thickness
AV8' /.
HardieSoffit,
a SRNN E?R1±SSURE RA1 iNG
AelCemsoffit
Installation Design Pressure
Metal Studs
ECY1Qt� B-B ` _
a ®avcr �v>�a II'><MODUCT RSM
EV
Mcomplying wimel�eflmiu ;
e� Coo& �` AFkVift No f.3�r3/de l.�? 4 121
wageWRlb
k1ARII[ES_O_FF�CEMSOF ITPAIb(EL IN-S_'C- LATION_DES�.S
= AU installation shall be done in conformance with this Notice of Acxeptan��! hS�anufacti'mes
installation recommendations, and the applicable sections of the Florida Building Code.
= Metal studs where HardieSoffit, Cemsoffit will be installed shall be designed by an Engineer or
Architect per the Florida Building Code and the requirements of this N.O.X
i The soffit shall be installed over minimum 209a, Nominal 3-5/a" X 1-518" Metal C-studs spaced
a maximum of %, O.C.
= [Note 1] The soffit fastener shall be a minimum No. 8-18, 0.316" head diameter X 1-1/4" long*
ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating metal ' 1\
framing) -,the fasteners shall be spaced at 6" O.C. at panel edges and intermediate studs; the
fasteners shall be driven into metal studs located at 16" O.C.
■ Fasteners shall have a minimum edge distance of $/8" and a minimum clearance of 2" from
comers.
Creator. E.•Gonzales.
HARDIESOFFIT, CEMSOFFIT PANEL
INSTALLATION DETAILS METALSTUD CONSTRUCTION
James Hardie Building Products, Inc.
1o9o1 Elm Avenue
Fontana, CA 92337
FSW NO I DM NO I REV
A I I PNL-PLKSOFF
12" = 9'-0" 1 Date: 4/24/20i3 1 SHEET 11 OF 12
Cladding
. Framing
a\
6.001n.
�-Fr "I
BY .
SIN�OF
FLOR\` -- P5
Is 10NP,
FRAMING,
■ NOMiNAL 20 GAUGE 3-M" X 1-58" STEEL STUDS 1W O.C. METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION
f FASTENED WITH 5/S■ WAFER HEAD SCREAMS (2 PER TOP NOT PART OFTH S APPROVAL (MUST P OVID1= ALTERNATE PROVISIONS AND
R THESE RE LOAD)
AND BOTTOM CONNECTION)
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
CLADDING HARDIESOFFIT, CEMSOFFIT PANEL
THE SOFFIT IS FASTENED WITH NO. 8-18, 0.315" HEAD INSTALLATION DETAILS METAL STUD CONSTRUCTION
3 - DIAMETER X 1.1/4 " LONG CORROSION RESISTANT' RIBBED
BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 James Hardie Building Products, Inc.
FULL. THREADS PENETRATING THE METAL FRAMING), PLACE 10901 Elm Avenue
SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE - o Fontana, CA 92337
STUDS I RFI
Phone., S09-356-6300 ZE FSCM NO DV.
Fax 909-427-0634 A PNl-PLK-SOFF 1
Creator. E Gonzales scare 1" Date: 4124l20i3 vri 12 OF 12