Loading...
HomeMy WebLinkAboutAPPROVED Generac Automatic Transfer SwitchGENERAL automatic iranster Switches GENERAC" PWWW Description PWRviewTm Automatic Transfer Switch 200 Amps, Single Phase Model: RXEMW200A3 E1� us •n .�,ammc usn us'q Intertek The Generac PWRview Automatic Transfer Switch integrates the PWRview monitor to provide real-time energy consumption data that can help lower a home's electricity bill. Through the convenient mobile app, a homeowner can access their energy usage and alert information while under utility power or generator power. The PWRview energy monitor is a simple to use and low cost tool that helps save money over the life of the generator. The 200 amp, open transition transfer switch is compatible with single-phase generators having either an Evolution— or Nexus"' Controller. Standard Features Service Rated Generac Automatic Transfer Switches are housed in an aluminum NEMA Type 311 enclosure, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is an ETL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. The integrated PWRview monitor provides real-time energy usage data through the PWRview app. All transfer switches are covered by a 5 year limited warranty. Load Management Technology Through the use of the integrated Smart A/C Module (SACM), these switches have the capability to manage up to four individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with external Smart Management Modules (SMM), a total of eight more loads can be managed, providing the most installation efficient power management options available. so 90 11• zoos GENERAC� 200 Amps, Single Phase Functions All timing and sensing functions originate in the generator controller. PWRview Automatic Transfer Switch Utility Voltage Drop -out <65% Timer to Generator Start 5 Second Factory Set, Adjustable Between 2 -1,500 Seconds by a Qualified Dealer Engine Warmup Delay 5 Seconds Standby Voltage Sensor 65% for 5 Seconds Utility Voltage Pickup >80% Re -transfer Time Delay 15 Seconds Engine Cooldown Timer 60 Seconds Exerciser Nexus": 12 Minutes Weekly Evolution": 5 to 12 Minutes Adjustable, Weeky/Bi-weekly/Monthly The Transfer Switch can be Operated Manually Without Power Applied * When used in conjunction with units utilizing Evolution— controls Specifications Amps 200 Voltage 120/240, 1e Load transition type (automatic) Open transition service rated Enclosure type NEMA Type 3R Compliance ETL Withstand rating (amps) 22,000 Lug range 250 MCM - #6 Dimensions, Weight, and Wire Ranges Dimensions and Weight Height (in/cm) H1 26.8 / 67.95 H2 30.1 / 76.43 Width (in/cm) Wi 10.5 / 26.67 W2 13.5 / 34.18 Depth (in/cm) 6.9 / 17.5 Weight (lbs/kg) 39.0 / 17.7 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 DEPTH GENE RAC � Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2020 Generac Power Systems, Inc. NI rights reserved. NI specifications are subject to change without notice. Part No. A0000380921 Rev C 07/22/2020