Loading...
HomeMy WebLinkAboutAPPROVED, PROJ-71324 - Eagan Residence SealedSHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEG-01REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590PLOT PLAN & VICINITY MAPCODES AND STANDARDSVICINITY MAPSHEET INDEXG-01COVER SHEETPROJECT DESCRIPTION:OWNERROOF OUTLINEA-01ROOF PLANS-01MODULE LAYOUTS-02ATTACHMENT DETAILSTRUCTURE CALCULATIONE-01ELECTRICAL LINE DIAGRAME-02WIRING CALCULATIONSE-03SYSTEM LABELINGSHEET SHEET DESCRITIONA-00NOTES AND DESCRIPTIONELECTRICAL CERTIFICATION:STRUCTURAL CERTIFICATION:S-01.1ARTIAL RESSURE AND MODULES EXOSURESUNPRO SOLAR4492 Eagle Falls Place,Tampa, FL 33619(866) 450-1012INSTALLERCastillo Engineering Services LLC620 N. Wymore Road, Suite 250, Maitland, FL 32751TEL: (407) 289-2575Ermocrates E. CastilloLicense#: FL PE 52590ENGINEEREAGAN, MARY27x380 LG NEON2: LG380N1C-A6 (380W) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESS-02.3I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATION.PROJECT SITE7505 KENWOOD RD,FORT PIERCE, FL 34951RACKING: UNIRAC LIGHT RAILATTACHMENT: S-5 SOLAR FOOT10.260 kW PV SYSTEMEAGAN RESIDENCEEQUIPMENT SUMMARY27 LG NEON2: LG380N1C-A6 (380W) MODULES27 ENPHASE: IQ7PLUS-72-2-US MICROINVERTERSDESIGN CRITERIA:WIND SPEED (ULT): 160 MPHWIND SPEED (ASD): 124 MPHRISK CATEGORY:IIEXPOSURE:CPROJECT SITEDS-01-12DATA SHEETSI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED.,CHAPTER 3. BUILDING STRUCTURE WILL SAFELYACCOMMODATE WIND LATERAL AND UPLIFTFORCES, AND EQUIPMENT DEAD LOADS.GOVERNING CODES:FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)NATIONAL ELECTRICAL CODE 2017 (NEC)ASCE 7-16FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)SYSTEM SIZE:10.260 kW DC STCARRAY AREA #1:195.03 SQ. FT.ARRAY AREA #2:195.03 SQ. FT.ARRAY AREA #3:136.52 SQ. FT.QBASE LOW SLOPE MOUNTATTACHMENT: STRUCTURE CALCULATIONS-02.2S-02.1ATTACHMENT DETAIL ATS00Section..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........AC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBACDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberVent, Attic fan(Roof obstruction)PV Roof AttachmentTrussesConduitFire AccessUM Utility MeterAC Alternating CurrentAPPROX ApproximateAWG American Wire GaugeCB Combiner BoxDC Direct CurrentACD AC DisconnectDISC Disconnect(E) ExistingEL ElevationEQ EqualJB Junction BoxMCB Main Combiner BoxMFR ManufacturerMIN MinimumMISC Miscellaneous(N) NewOCPD OverCurrent Protection DevicePOCC Point Of Common CouplingPV PhotovoltaicSF Squarefoot/feetSTC Standard Test ConditionsTBD To Be DeterminedTYP TypicalUNO Unless Noted OtherwiseVIF Verify In FieldWP Weather ProofGPGeneration PanelMDPMain Distribution PanelSDSoladeckNAVD North American Vertical datumMID Microgrid Interconnect DeviceMicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxFigure 1: PV System Block DiagramSystem DescriptionThis system is a grid-tied, PV system, with PV generation consisting of27x380 LG NEON2: LG380N1C-A6 (380W) Modules with a combined STC rated dcoutput power of 10,260W. The modules are connected into 27 ENPHASE:IQ7PLUS-72-2-US Microinverters. The inverter has electronic maximum powerpoint tracking to maximize energy captured by the PV modules. The inverter alsohas an internal ground fault detection and interruption device that is set todisconnect the array in the event that a ground fault that exceeds one ampereshould occur. The inverter has DC and AC disconnect integrated system and labelsare provided as required by the National Electrical Code.When the sun is shining, power from the PV array is fed into the inverter,where it is converted from DC to AC. The inverter output is then used tocontribute to the power requirements of the occupancy. If PV power meets therequirements of the loads of the occupancy, any remaining PV power is sold backto the utility. When utility power is available, but PV power is not available,building loads are supplied by the utility.The inverter meets the requirements of IEEE 1547 and UL 1741.SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEA-00REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590NOTES ANDDESCRIPTIONSymbols:Abbreviations:ALLOWABLE/DESIGN PRESSUREPSFDOWN PRESSURE126UPLIFT PRESSURE, 2 RAILS8968.5"41.0"RAILS IN THISPOSITION UNOFALL PROTECTION:ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENTMUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT ORSUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDSPER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:·AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICHMAINTAINS A SAFETY FACTOR OF AT LEAST TWO.·UNDER THE SUPERVISION OF A QUALIFIED PERSONADDITIONAL INFORMATION·29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.·1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES···1926.502(D)(15)LG NEON2:LG380N1C-A6(380W) MODULES 135'-0"81'-5"135'-0"81'-5"61'-4"12'-6"35'-0"31'-0"UMMDPCBACDSDSHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEA-01REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590ROOF PLANA-01SCALE: 1/16" = 1'-0"1ROOF PLAN WITH FIRE SETBACKSAND PROPERTY LINES- FIRE SETBACK - 3 FT- ZONING SETBACK - 2 FTKENWOOD RD,EXISTING DRIVEWAY(N) SOLADECK(N) ALTERNATIVE POWER SOURCEAC DISCONNECT/RAPID SHUTDOWN(E) MAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANEL(E) SERVICE POINT ANDUTILITY METERING(N) ENPHASE IQ COMBINER BOX1" IMC, RMC, FMC, LFMC,EMT OR EQUIVALENTCONDUIT RUN(E) DETECTED STRUCTUREPOOLROOF #2(10) LG NEON2: LG380N1C-A6(380W) MODULESROOF #1(10) LG NEON2: LG380N1C-A6(380W) MODULESROOF #3(07) LG NEON2: LG380N1C-A6(380W) MODULES(N) (27) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERS3'-0" FIRE SETBACK3'-0" FIRE SETBACK1' - 6 " F I R E S E T B A C K1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK3'-0" FIRE SETBACKFIRE ACCESS AND PATHWAYSAS PER NFPA 1, 11.12.2EXISTING DRIVEWAY1-STORYHOUSE 50'-6"56'-5"9'-0" TYP.4'-0" TYP.SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMES-01REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 525901S-01SCALE: 3/32" = 1'-0"MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 27 MODULESMODULE TYPE = LG NEON2: LG380N1C-A6 (380W) MODULESMODULE WEIGHT = 41.01 LBS / 18.6 KG.MODULE DIMENSIONS = 68.5" x 41.0" = 19.50 SFUNIT WEIGHT OF ARRAY = 2.10 PSF(E) BACK YARD(E) FRONT YARDROOFROOF TYPEARRAYAREA(sq.Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHTRUSSSIZESEAMSPACING#1METAL195.03514.2637.9318.4°0°2"X4"24" O.C.#2METAL195.03514.2637.9318.4°180°2"X4"24" O.C.#3FLAT136.52329.2541.474.8180°2"X4"24" O.C.LEGEND- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)MODULE LAYOUTMODULE LAYOUTGENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO TRUSSES SHALL BE INSTALLED AS SHOWNIN SHEET S-02 & S-02.1 AND AS FOLLOWS FOR EACH WIND ZONE:WINDZONESNON-EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 12' - 0"0' - 8"2' - 0"0' - 8"ZONE 1'XXXXZONE 2e2' - 0"0' - 8"2' - 0"0' - 8"ZONE 2n2' - 0"0' - 8"2' - 0"0' - 8"ZONE 2r2' - 0"0' - 8"2' - 0"0' - 8"ZONE 3e2' - 0"0' - 8"2' - 0"0' - 8"ZONE 3r2' - 0"0' - 8"2' - 0"0' - 8"WINDZONESNON-EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 14' - 0"1' - 4"4' - 0"1' - 4"ZONE 1'4' - 0"1' - 4"4' - 0"1' - 4"ZONE 24' - 0"1' - 4"2' - 0"0' - 8"ZONE 32' - 0"0' - 8"2' - 0"0' - 8"FOR GABLE ROOF:LEGEND- WIND ZONE 1 (TYP)- WIND ZONE 1' (TYP)- WIND ZONE 2 (TYP)- WIND ZONE 3 (TYP)FOR FLAT ROOF:FOR FLAT ROOF:QBASE LOW SLOPE MOUNT(26) PV ROOF ATTACHMENT@ 24" O.C. MAX.(SEE SHEET S-02.1 FORATTACHMENT DETAIL)(SEE SHEET S-01.1 FOR PARTIALPRESSURE OF THE MODULE)(N) UNIRAC LIGHT RAIL (TYP.)(N) (27) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSROOF #1(10) LG NEON2: LG380N1C-A6 (380W)MODULESUNIRAC S-5 SOLARFOOT(76) PV ROOF ATTACHMENT@ 24" O.C. MAX.(SEE SHEET S-02 FORATTACHMENT DETAIL)(SEE SHEET S-01.1 FOR PARTIALPRESSURE OF THE MODULE)ROOF #1TILT - 18.4°AZIM. - 0°SEE SHEET S-02.2 & S-02.3 FOR SUPPORTING CALCULATIONS.2) EXISTING RESIDENTIAL BUILDING HAVE SYP TRUSSES SPACED @ 24" O.C.AND METAL ROOF DECKS WITH MEAN ROOF HEIGHT OF 15 FT WITH SEAMSSPACED 12" O.C. EXISTING ROOF SLOPE FOR THE SOLAR RETROFIT IS 18.4 & 4.8DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THEENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELDCONDITIONS.3) FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18" EACH WAY FROMHIPS AND VALLEYS PER NFPA 1, 11.12.2.4) THE EXISTING ROOF AND STRUCTURE WILL NOT BE ADVERSELY AFFECTEDDUE TO THE ADDITIONAL LOADS IMPOSED BY THE SOLAR SYSTEM.* I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITHFBC: RESIDENTIAL 2020 7TH ED. CHAPTER 3. BUILDING STRUCTURE WILLSAFELY ACCOMMODATE WIND LATERAL AND UPLIFT FORCES AND EQUIPMENTDEAD LOADS. *ROOF #3TILT - 4.8°AZIM. - 180°ROOF #2(10) LG NEON2: LG380N1C-A6 (380W)MODULESROOF #3(07) LG NEON2: LG380N1C-A6 (380W)MODULESROOF #2TILT - 18.4°AZIM. - 180° 9'-0" TYP.4'-0" TYP. 5'-6"P1P2P3P4P5P6SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMES-01.1REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590PARTIAL PRESSURE ANDMODULES EXPOSURE1PARTIAL PRESSURE AND MODULES EXPOSURES-01.1SCALE: 3/32" = 1'-0"2h₂LEGEND- NON- EXPOSED MODULE- MIN. MODULE EDGE DISTANCE LINE- EDGE MODULE- MODULE EXPOSURE LINE- EXPOSED MODULE- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)- MISSING MODULENOTE: PARTIAL PRESSURES OF THE WIND ZONES ONALL MODULES HAVE BEEN VERIFIED AND ARE WITHINTHE ALLOWABLE PER THE MANUFACTURERSPECIFICATION, INSTALLER SHOULD FOLLOW THELAYOUT TO AVOID HIGHER ZONAL PARTIALPRESSURES. ANY CHANGES IN LAYOUT SHOULD BEREPORTED BACK TO THE ENGINEER OF RECORD.FOR GABLE ROOF2h2DISTANCE : 1' -0"0.5hDISTANCE : 7' - 6"ALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS : 89 PSFFOR EXPOSED MODULES (GABLE ROOF)FOR NON-EXPOSED MODULES (GABLE ROOF)FOR EDGE MODULES (FLAT)LEGEND- WIND ZONE 1 (TYP)- WIND ZONE 1' (TYP)- WIND ZONE 2 (TYP)- WIND ZONE 3 (TYP)FOR FLAT ROOF:FOR FLAT ROOF2h2DISTANCE : 2' -0"0.5hDISTANCE : 7' - 6"(E) BACK YARD(E) FRONT YARDROOF #1(10) LG NEON2: LG380N1C-A6 (380W)MODULESROOF #2(10) LG NEON2: LG380N1C-A6 (380W)MODULESROOF #3(07) LG NEON2: LG380N1C-A6 (380W)MODULES (E) STANDINGSEAM ROOF(N) MID CLAMPS-5 SOLAR FOOTBOLT, 3/8-16 X 1" HEX CS SSUNIRAC LIGHT (TYP.)2 -1/4" X 2.5" LAG BOLTS(N) END CLAMP2'-0"2"X4" TRUSSES @ 24" O.C.6"1. SolarFoot2. M8-1.25 Stainless Steel Hex Flange Nut (13mm Socket)4. Example roofSolarFootBackLeftFrontRightTop3. Metal to Metal:1/4-14 Self Drilling Screw 1-1/2" to 2-1/2"Metal to Wood:1/4-14 Type 17 AB Milled Point 1-1/2" to 3-1/2"General Notes:.50in1.00in1.50in2.00in [8mm](4x)∅.315in.66in1.32in1.39in.32inFactory AppliedButyl SealantM8-1.25 Threaded Stud1.39in.32in3.67in2.3..67inROOF SHEATHINGROOF TRUSS(2) 1/4-14 LAG SCREWS PERSOLARFOOT MUST BE ATTACHEDINTO EXISTING ROOF TRUSSES WITH2.5" MINIMUM EMBEDMENTDRILL PILOT HOLE PRIOR TO LAG ROOFATTACHMENT AND FILL WITH DURALINK 35(2) LAGS ROOFTRUSS ATTACHMENT3.67in3.17in1.83in.500in4.1.SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMES-02REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590STRUCTURALATTACHMENTDETAILSh2ATTACHMENT DETAIL (FRONT VIEW)SCALE: 1" = 1'-0"S-0212ATTACHMENT DETAIL (ENLARGED VIEW)S-02SCALE: NTS(E) 5/8" ROOF SHEATHING4"X4" TRUSS SPANNER ORBLOCKING FOR MISSED TRUSSATTACHMENT (IF REQUIRED) 1'-0"1'-0"SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMES-02.1REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590STRUCTURALATTACHMENTDETAILS2ATTACHMENT DETAIL (ENLARGED VIEW)S-02.1SCALE: 3" = 1'-0"ATTACHMENT DETAILS-02.1SCALE: 1" = 1'-0"1SEE (2/S-02.1) FORENLARGED VIEWSOLAR MODULEFLAT ROOF5/16"DIA. X 3"MIN. EMBEDMENT LAG SCREW ATEACH ATTACHMENT POINT INTO EXISTING FRAMINGQMLSH: QBASE LOWSLOPE MOUNTL-FOOTGROUNDING & END/MID CLAMP2"X4" TRUSSES @ 24" O.C.2"X4" TRUSSES @ 24"" O.C.4"X4" TRUSS SPANNER FORMISSED TRUSS ATTACHMENT(IF REQUIRED)MAINTAIN 3/4" DISTANCE FROMTHE EDGE PER NDS 2018h₂(N) UNIRAC LIGHT RAILSOLAR MODULEFLAT ROOFAPPLY M1 SEALANT TO BOTTOM OF QBASEMOUNT, AND COAT ENTIRETY OF QBASE,BOLTS, AND POST TO 3" ABOVE ROOF LINESEE SHEET DS-10 FOR SEALANT SPECS, SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMES-02.2REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590STRUCTURALCALCULATIONSFOR GABLE ROOF: SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMES-02.3REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590STRUCTURALCALCULATIONSFOR FLAT ROOF: SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEE-01REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590ELECTRICALLINE DIAGRAMQ CABLESL2L1NL2L1GN20A/2PGG(N) SOLADECK600V, NEMA 3RUL LISTEDGGGGGGGGGGL2L1L2L1(N) JUNCTION BOX600V, NEMA 3RUL LISTED#6 BARE CU WIRE PROTECTED PER NEC 250.64(B)GENPHASE: IQ7PLUS-72-2-USMICROINVERTERSPV MODULESGGGGGGGGGL2L1L2L1L2L120A/2PFACTORY INSTALLED10A OR 15ABREAKER FOR ENVOY (N) 125A ENPHASE IQ COMBINER 3(X-IQ-AM1-240-3) [WITH UPTO (4)2-POLE BREAKERS AND ENVOYCOMMUNICATION GATEWAY]SOLAR ARRAY (10.260 kW-DC STC)(27) LG NEON2: LG380N1C-A6 (380W) MODULES(02) BRANCHES OF 10 MODULES(01) BRANCH OF 07 MODULESINTERCONNECTION120% RULE - NEC 705.12(B)(2)(3)(b)UTILITY FEED + SOLAR BACKFEED200A + 50A = 250ABUSS RATING x 120%225A x 120% = 270AEXISTINGGROUNDINGELECTRODESYSTEMTO UTILITY GRIDL2L1L2L1GL2L1L2L1L2L1L2L1L1L2NL1L2NN(E) BI-DIRECTIONALSERVICE POINT ANDUTILITY METERING1-PHASE, 240V(E) MAIN BREAKER200A/2P, 240V50A/2P(E) MAIN SERVICEDISCONNECT/MAINDISTRIBUTION PANEL,225A RATED, 240VNOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TOMEET THE REQUIREMENTS OF THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATION, INCLUDING MAXIMUMNUMBER OF MODULE STRINGS, MAXIMUM NUMBEROF MODULES PER STRING, MAXIMUM OUTPUT,MODULE MANUFACTURER AND MODEL NUMBER,INVERTER MANUFACTURER AND MODEL NUMBER,AS APPLICABLE.2. THE PV BACKFED BREAKER IS AT THE END OF THEBUSBAR AND THERE IS NO LUG FED SUB PANEL.3. REFER SHEET DS-12 FOR LOAD CALCULATIONS.L2L1NGL2L1NG(N) ALTERNATIVE POWERSOURCE AC DISCONNECT/RAPID SHUTDOWN:240V, 60AMP RATED,NEMA 3R, UL LISTED,LOCKABLE & NON-FUSIBLEL1L2NGGGGGGGGG(3) #10 AWG THWN-2-RED(3) #10 AWG THWN-2-BLACKEGC #6 AWG THWN-2 GNDIN 1" IMC, RMC, LFMC, PVC,RTRC, LFNC, FMT OR EMTCONDUIT RUN(3) #6 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1" PVC, IMC, RMC, LFMC,RTRC, LFNC, EMT OR FMTCONDUIT RUN(3) 10/2 ROMEX RUN IN ATTICOR(3) #10 AWG THWN-2 – RED(3) #10 AWG THWN-2 – BLACKEGC #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, LFMC,EMT OR EQUIVALENTCONDUIT RUNL2L1L2L1L120A/2PL21ELECTRICAL LINE DIAGRAME-01SCALE: NTS SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEE-02REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590WIRINGCALCULATIONSELECTRICAL CALCULATIONELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELEDFOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALLBE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TOTHE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICALEQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES ANDSTANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARENOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ANDREADILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHTRESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FORUSE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).17.THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PVCONDUCTORS IN COMPLIANCE WITH NEC 690.12.18.LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWNON SHEET E-03.19.ALL CONDUITS TO BE INSTALLED A MIN OF 7/8" ABOVE THE ROOFSURFACE.I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATION. UMMDPCBACDSHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEE-03REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590SYSTEM LABELINGRAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMLABEL LOCATION:AC DISCONNECT(PER CODE: NEC 690.56(C)(3))WARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.13(B))TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!TURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSNOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60290A240A1.2120LABEL LOCATION:COMBINER BOX(PER CODE: NEC 690.52)DATA PER PANELLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 32.67 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNING:POWER SOURCE OUTPUT CONNECTION DONOT RELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE VISIBLE, REFLECTIVE AND SUITABLE FORTHE ENVIRONMENT WHERE IT IS INSTALLED [NFPA 1, 11.12.2.1]· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]PV SOLAR ARRAYON ROOFCAUTION!LABEL LOCATION:MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECTLOCATED NO MORE THAN 3FT (1M) FROM THE SERVICE DISCONNECT(TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8")(PER CODE: NEC 690.56(B), NEC 705.10, NFPA 1, 11.12.2.1)POWER TO THIS BUILDINGSUPPLIED FROM MULTIPLE SOURCES EMERGENCY RESPONDER:THIS SOLAR PV SYSTEM IS EQUIPPEDWITH RAPID SHUTDOWN.TURN RAPID SHUTDOWN SWITCH TO THE ''OFF''POSITION TO SHUTDOWN ENTIRE PV SYSTEMSERVICE POINT ANDUTILITY METERINGMAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANEL7505 KENWOOD RD, FORT PIERCE, FL 34951ALTERNATIVE POWERSOURCE AC DISCONNECT/RAPID SHUTDOWNLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 1204.5.1AC DISCONNECT10.260 KW SOLARDISCONNECT LOCATEDPHOTOVOLTAICSYSTEM MICROINVERTERSLOCATED UNDER EACHPV MODULE INROOF TOP ARRAYAC COMBINER BOXLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)LABEL LOCATION:COMBINER BOX(PER CODE: NEC 690.52)LABEL LOCATION:INVERTER(PER CODE: NEC 690.52)LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)SOLARBREAKERLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))ENPHASE IQ COMBINER BOXWARNINGIN CASE OF EMERGENCY CONTACT:SUNPRO SOLARPH. NO. - (866) 450-1012LABEL LOCATION:MAIN DISCONNECT(PER CODE: NFPA - 1, 11.12.2.1.5)!! SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-01REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-02REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-03REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-04REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-05REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-06REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-07REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-08REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-09REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-10REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-11REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET SHEET NAMESHEET SIZESHEET NUMBEREAGAN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-12REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS7505 KENWOOD RD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCCASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET