Loading...
HomeMy WebLinkAboutAPPROVED_02-18-2022_PLANSET(1)-RestampVICINITY MAPSITE MAP (N.T.S)A-00SITE MAP &VICINITY MAPGARRY WILLIAMSNEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEMDC SYSTEM SIZE (13.94KW)33°C3°C0 PSF170MPH (ASCE 7-16)IIDWIND FLOW MAPSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809GOVERNING CODESFLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)FLORIDA EXISTING BUILDING CODE, 7TH EDITION 2020(FBC EX)SITE MAP & VICINITY MAPA - 00A - 01S - 01ELECTRICAL LINE DIAGRAMWIRING CALCULATIONSSYSTEM LABELINGMODULE DATASHEETE - 01E - 02E - 03STRUCTURAL ATTACHMENT DETAILSINVERTER DATASHEETCOMBINER DATASHEETDS - 01DS - 02DS - 03DS - 04S - 02SHEET INDEXSHEET NO.SHEET NAMEROOF PLAN & MODULESARRAY LAYOUTSITE DETAILSASHRAE EXTREME LOWASHRAE 2% HIGHGROUND SNOW LOADWIND SPEEDRISK CATEGORYWIND EXPOSURE CATEGORYTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MINDY NICOLEO'NEAL, PE ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THISDOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATUREMUST BE VERIFIED ON ANY ELECTRONIC COPIES.RACKING DATASHEETATTACHMENT DATASHEET9.84 KWSYSTEM SIZE :13.94 KW DC STC41 A(41) ENPHASE IQ7-60-2-US MICROINVERTERSBACKFEED BREAKER IN THE MMCDC RATING OF SYSTEMAC RATING OF SYSTEMAC OUTPUT CURRENTNO. OF MODULESNO. OF INVERTERSPOINT OF CONNECTIONARRAY STRINGINGDESCRIPTIONNEW GRID-INTERACTIVE PHOTOVOLTAICSYSTEM WITH NO BATTERY STORAGESYSTEM DETAILS(41) HANWHA Q CELL Q.PEAK DUO BLK-G6(340W) SOLAR MODULES(2) BRANCHES OF 14 MODULES(1)BRANCH OF 13 MODULESDS - 05FPLUTILITYNATIONAL ELECTRIC CODE, NEC 2017 CODE BOOK, NFPA 70235'-9"236'-7"7'-11" 4'105'-4"DRIVEWAY84'-10"82'114'-6"M(E) METER MAIN COMBO(OUTSIDE HOUSE)ROOF 13' SETBACKPV ARRAYS INDIAN RIVER DRROOF 2ROOF 318" SETBACK A-01 & MODULESROOF PLANMODULE TYPE, DIMENSIONS & WEIGHTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3.BUILDINGSTRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFTWIND LOADS, AND EQUIPMENT DEAD LOADS. *GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO RAFTERS SHALL BE INSTALLEDAS SHOWN IN SHEET S-01 AND AS FOLLOWS FOR EACH WINDZONE:.WIND ZONE 1: MAX SPAN 4'-0" O.C.WIND ZONE 2: MAX SPAN 4'-0" O.C.WIND ZONE 3: MAX SPAN 2'-0" O.C.2) EXISTING RESIDENTIAL BUILDING ROOF WITH MEAN ROOFHEIGHT 15 FT AND 2"x4" WOOD ROOF RAFTERS SPACED 24" O.C.CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THEENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANSAND IN FIELD CONDITIONS.LEGENDSUMACDPMMSP- UTILITY METERJB- AC DISCONNECT-PRODUCTION METER- MAIN SERVICE PANEL- VENT, ATTIC FAN(ROOF OBSTRUCTION)- JUNCTION BOXINV- INVERTER- CONDUIT- STRING TAG- FIRE SETBACKNUMBER OF MODULES = 41 MODULESMODULE TYPE = HANWHA Q CELL Q.PEAK DUO BLK-G6 (340W) SOLARMODULESWEIGHT = 43.87 LBS / 19.9 KG.MODULE DIMENSIONS = 68.50" X 40.55" = 19.29 SFNUMBER OF INVERTER = 41 MICROINVERTERSINVERTER TYPE = ENPHASE IQ7-60-2-US MICROINVERTERSDC SYSTEM SIZE: 13.94 KWAC SYSTEM SIZE: 9.84 KWM- METER MAIN COMBO1- MODULE STRING2- MODULE STRING3- MODULE STRING1BI- BACKUP INTERFERNCEBAT- BATTERYCP- COMBINER PANELSWH- SMART WATER HEATERM(E) METER MAIN COMBO(OUTSIDE HOUSE)ROOF 13' SETBACKPV ARRAYACDCP(N) AC DISCONNECT(NON-FUSIBLE)(N) COMBINER PANEL(OUTSIDE HOUSE)JBCONDUIT RUNROOF ACCESS POINTROOF ACCESS POINT(E)BACK YARD(E)FRONT YARD11111111111112222222222222233333333333331ROOF 2ROOF 318" SETBACKNOTES:1.LOCATION OF JUNCTION BOX(ES), ACDISCONNECTS(S), AC COMBINER PANEL(S),AND OTHER ELECTRICAL EQUIPMENT(S)RELEVANT TO PV INSTALLATION SUBJECT TOCHANGE BASED ON SITE CONDITIONS.ROOF ACCESS POINT S-01ARRAYLAYOUT(ROOF #1)ROOF DESCRIPTION:SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809MODULES - 24ROOF TILT - 07°ROOF AZIMUTH - 180°RAFTER SIZE - 2"X4" @ 24" O.C.LEGENDS- VENT, ATTIC FAN(ROOF OBSTRUCTION)- PV ROOF ATTACHMENT- RAFTERS / TRUSSES- RAILS- FIRE SETBACKWIND LOAD INFORMATION:THIS SYSTEM HAS BEEN DESIGN TO MEETTHE REQUIREMENTS OF THE 7TH EDITION OFTHE FLORIDA BUILDING CODE AND USED THE FOLLOWING DESIGN PARAMETERS: ULTIMATE WIND SPEED: 170 MPHEXPOSURE CATEGORY: DRISK CATEGORY: II MEAN ROOF HEIGHT: 15 ROOF SLOPE: 0°-7°- WIND ZONE 1- WIND ZONE 1'WIND ZONE 2- WIND ZONE (2)- WIND ZONE (2r)-WIND ZONE (2e)- WIND ZONE (2n)WIND ZONE 3- WIND ZONE (3)- WIND ZONE (3r)-WIND ZONE (3e)- METAL SEAMWIND ZONE 1TRUSS/ RAFTERS LOCATIONS AREAPPROXIMATE. ACTUAL LOCATIONS MAYDIFFER AND CONTRACTOR MAY NEED TOADJUST MOUNT LOCATIONS. IN NO CASESHALL THE MOUNT SPACING EXCEED "MAX.MOUNT SPACING"(ROOF #3)(ROOF #2)MODULES -08ROOF TILT - 07°ROOF AZIMUTH - 270°TRUSSES SIZE - 2"X4" @ 24" O.C.MODULES -09ROOF TILT - 07°ROOF AZIMUTH - 90°TRUSSES SIZE - 2"X4" @ 24" O.C.44'-6"40'-6"23'-8"42'-8"64'-2"3' SETBACKSOLAR MODULEROOF #1ROOF #2ROOF #340'22'-3"45'-11"40'45'-11" 22'-3"18" SETBACK PHOTOVOLTAIC MODULE GENERAL NOTES:1. APPLICABLE CODE: 2020 FLORIDA BUILDING CODE 7th ED. & ASCE 7-16MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012)REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A WOOD ROOF TRUSS AS EMBEDMENT MATERIAL.3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLERESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27° (2/12 TO AMAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOTEXCEED 30'-0" MEAN ROOF HEIGHT.4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511.5.THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TOMANUFACTURERS' MANUAL FOR ALL ARCHITECTURAL, MECHANICAL,ELECTRICAL, AND SOLAR SPECS.6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESSOTHERWISE NOTED.7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED.8.ALL RAILING AND MODULES SHALL BE INSTALLED PERMANUFACTURERS' INSTRUCTIONS.9. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCEWITH FBC:BUILDING CHAPTER 16 AND FBC:RESIDENTIAL CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATEDWIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS.S-02STRUCTURAL ATTACHMENTDETAILSSTRUCTURAL ATTACHMENT DETAILSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809SOLAR MODULEQUICK MOUNT, Q.BASE5/16"x4" STAINLESSSTEEL LAG SCREWIRONRIDGE XR100 RAILSIRONRIDGE L-FOOTROLLED ASPHALT ROOFQUICK MOUNT, FLASHINGQUICK MOUNT(STAND POST )SOLAR MODULE5/16"x4" STAINLESSSTEEL LAG SCREWWOOD ROOFTRUSS TYP.IRONRIDGE XR100 RAILSIRONRIDGE L-FOOTROLLED ASPHALT ROOFQUICK MOUNT, FLASHINGQUICK MOUNT(STAND POST )QUICK MOUNT, Q.BASE E-01ELECTRICALLINE DIAGRAMSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809SOLAR ARRAY (13.94KW-DC STC)(41) HANWHA Q CELL Q.PEAK DUO BLK-G6 (340W)SOLAR MODULES(2) BRANCHES OF 14 MODULES(1) BRANCH OF 13 MODULESPER FL. STATUE 377.705 (REVISED 7/1/2017) I, MINDY NICOLE O'NEAL PE#69779,AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THEMOST RECENT VERSION OF THE FLORIDA BUILDING CODE.ENPHASE IQ7-60-2-USMICROINVERTERSPV MODULESL2L1NG15A20A/2PL2L1GN G20A/2PL2L120A/2PL2L1(N)JUNCTION BOX600 V, NEMA 3RUL LISTED(3) #10 AWG THWN-2 - RED(3) #10 AWG THWN-2 - BLACK(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNQ CABLES(N) AC DISCONNECT:240V, 60AMP, UNFUSEDNEMA 3R, UL LISTEDTO UTILITY GRIDL1 L2 NBI-DIRECTIONALUTILITY METER1-PHASE, 240V(OUTSIDE HOUSE)L2L1L2L160A/2PL2L1NGL2L1L2L1L2L1L1 L2 NEXISTING GROUNDINGINTERCONNECTION120% RULE - NEC 705.12(B)(2)(3)(b)UTILITY FEED + SOLAR BACKFEED175A + 60A = 235 ABUS RATING x 120%200A x 120% = 240A175A/2P(3) #6 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNL2L1GL2L1NGN(N) MAIN BREAKERDERATE FROM 200ATO 175A(N) ENPHASE IQ COMBINER 3 (X-IQ-AM1-240-3) [WITH UP TO (4)2-POLE BREAKERS AND ENVOY COMMUNICATION GATEWAY](N)BACKFEEDBREAKER(E)METER MAIN COMBO, 200A RATED, 240V.(OUTSIDE HOUSE)(N) MAIN BREAKER 175A/2P, 240VNOTE:1.SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, NFPA 70 AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDINGMAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OFMODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURERAND MODEL NUMBER, INVERTER MANUFACTURER AND MODELNUMBER, AS APPLICABLE.2.PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTERSPACE IS INADEQUATE.3.IF METER MAIN COMBO CONTAINS FEED THRU LUGS, CONTRACTORSHALL VERIFY THAT THE FEEDERS CONNECTED TO THESE LUGS ARE PROTECTED AS REQUIRED BY NEC 705.12(B)(2)(1)(A) OR (B). E-02WIRINGCALCULATIONSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809ELECTRICAL NOTES1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR75 DEGREE C.3. CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.144.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE ASPOSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.5. WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDAND READILY VISIBLE.9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).ELECTRICAL CALCULATIONS:1.CURRENT CARRYING CONDUCTOR(A)BEFORE IQ COMBINER PANELAMBIENT TEMPERATURE = 33°CCONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(c)TEMPERATURE DERATE FACTOR - 0.96 ...NEC 310.15(B)(2)(a)GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a)CONDUCTOR AMPACITY= (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B)= [(14 x 1) x 1.25] / 0.96 / 0.8= 22.79 ASELECTED CONDUCTOR - #10 THWN-2 ...NEC 310.15(B)(16)(B)AFTER IQ COMBINER PANELTEMPERATURE DERATE FACTOR - 0.96GROUPING FACTOR - 1 CONDUCTOR AMPACITY=(TOTAL INV O/P CURRENT) x 1.25 / 0.96 / 1 ...NEC 690.8(B)=[(41x 1) x 1.25] /0.96 / 1=53.39 ASELECTED CONDUCTOR - #6 THWN-2 ...NEC 310.15(B)(16)2. PV OVER CURRENT PROTECTION ..NEC 690.9(B)=TOTAL INVERTER O/P CURRENT x 1.25=(41 x 1) x 1.25 = 51.25 ASELECTED OCPD = 60ASELECTED EQUIPMENT GROUND CONDUCTOR (EGC) = #10 THWN-2 ... NEC 250.122(A)INVERTER SPECIFICATIONSMANUFACTURERENPHASEMODEL NO.IQ7-60-2-USMAX DC INPUT VOLTAGE48 VMAX OUTPUT POWER240 VANOMINAL AC OUTPUT VOLTAGE 240 VNOMINAL AC OUTPUT CURRENT 1 AMODULE SPECIFICATIONMODEL NO.HANWHA Q CELL Q.PEAK DUOBLK-G6(340W)PEAK POWER340WRATED VOLTAGE (Vmpp)33.94 VRATED CURRENT (Impp)10.02 AOPEN CIRCUIT VOLTAGE (Voc)40.66 VSHORT CIRCUIT CURRENT (Isc)10.52 A E-03SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809SYSTEMLABELINGWARNINGELECTRIC SHOCK HAZARD!DO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONPHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 41 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGNOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATINGFOR AC MODULE PROTECTION PER CIRCUIT-240240120VVA 60 HzAAINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICEPHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDWARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING PHOTOVOLTAICPOWER SOURCE!855-335-2469EMERGENCY CONTACTWARNING!INVERTER OUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNING!DEDICATED SOLAR PANELS DONOT CONNECT ANY OTHER LOADSSHUTDOWNSOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION, COMBINER PANEL(PER CODE: NEC 690.13(B))LABEL LOCATION:AC DISCONNECT, INVERTER(PER CODE: NEC 690.54)LABEL LOCATION:CONDUIT RUNWAY(PER CODE: NEC690.31(G)(3)(4))LABEL LOCATION:MAIN SERVICE DISCONNECT(NEC 705.12(B)(3-4) & NEC 690.59)ADHESIVE FASTENED SIGNS:·ANSI Z535.4-2011 PRODUCT SAFETY SIGNS AND LABELS, PROVIDESGUIDELINES FOR SUITABLE FONT SIZES, WORDS, COLORS, SYMBOLS, ANDLOCATION REQUIREMENTS FOR LABELS. NEC 110.21(B)(1)·THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THEENVIRONMENT INVOLVED. NEC 110.21(B)(3)·ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLYADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT. IFC 605.11.1.3LABEL LOCATION:COMBINER PANEL, AC DISCONNECT(PER CODE: NEC 690.52)LABEL LOCATION:POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT(PER CODE: NEC 705.12 (B)(2)(c))[Not required if panelboard is rated not less than sum of ampere ratingsof all overcurrent devices supplying it]DATA PER PANELLABEL LOCATION:AC DISCONNECT, DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC 690.56(C)(3))IFC 605.11.3.1(1) & 690.56(C)(1)(a) Label for PV Systems thatShut down the array and the conductors leaving the array DS-01DATASHEETMODULESHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809 DS-02DATASHEETINVERTERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809 DS-03DATASHEETCOMBINERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809 DS-04DATASHEETRACKINGSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809 DS-05DATASHEETATTACHMENTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAH02/18/2022DESIGNERREVIEWERDATEGARRY WILLIAMS 11097 S INDIAN RIVER DR, FORT PIERCE, FL 34982 ENGG.ENGINEER OF RECORDPHONE: 855-335-24695344 9TH ST, ZEPHYRHILLS FL 33541LICENSE# EC13010029CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USA FLORIDAREGISTRY# 33809