Design Criteria:
Subject: Structural Certification for Installation of Residential Solar
re job:
Attn.: To Whom It May Concern
Observation of the condition of the existing framing system was performed by an audit team of
After review of the field observation data, structural capacity calculations were performed in accordance
with applicable building codes to determine adequacy of the existing roof framing supporting the proposed
panel layout. Please see full Structural Calculations report for details regarding calculations performed and
limits of scope of work and liability. The design criteria and structural adequacy are summarized below:
03-14-2022
Freedom Forever LLC
Stowell, Edward
Freedom Forever LLC
ROOF 1: Shingle roofing supported by 2x4 Truss @ 24 in. OC spacing. The roof is sloped at
approximately 24 degrees and has a max beam span of 6.0 ft between supports. Roof is adequate to
support the imposed loads. Therefore, no structural upgrades are required.
Code: 2020 FBC, ASCE 7-16, Ult Wind Speed: 157 mph, Ground Snow: 0 psf, Min Snow Roof: 0 psf