APPROVED, PV Plans Stamped
PV-1FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------THIS PROJECT COMPLIES WITH THE FOLLOWING:2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY2020 7TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)2017 NATIONAL ELECTRIC CODE (NEC)AS ADOPTED BY ST. LUCIE COUNTYSITE LOCATIONCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:PHOTOVOLTAIC SYSTEMPV-1SITE LOCATIONPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BSTRUCTURAL CALCULATIONSPV-3MOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-7ASITE PLACARDPV-8OPTIMIZER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIXMANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2017 NECTHE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMSOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDSINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.SITE LOCATIONGREG ALBRIGHT1. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans and accompanying calculations and notify the Engineer of Record of any discrepancies prior to starting construction.2. These plans are stamped for structural code compliance of the roof framing supporting the proposed PV installation referenced only. These plans are not stamped for water leakage. PV modules, racking, and attachment components must follow manufacturer guidelines and requirements.3. Please see accompanying Structural Calculations report for details regarding calculations as well as limits of scope of work and liability.NOTE TO INSTALLERS: VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION ANDNOTIFY THE EOR AT 951.405.1733 IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING: 2x4 TRUSSES @ 24" OC SPACING WITH MAX UNSUPPORTED SPANEQUAL OR LESS THAN 8 FT. MSPACINVJBSITE PLANSCALE: 1/16" = 1'-0"1DRIVEWAYTOTAL ROOF AREA RIDGE SETBACK CALCS:TOTAL ROOF AREA: 2697 SQ FTSINGLE MODULE AREA: 17.98 SQ FTTOTAL NUMBER OF MODULES: 31TOTAL AREA OF MODULES: 557.38 SQ FTROOF COVERAGE: 20.67%FIRE SPRINKLERS : NOPV SYSTEM8.835 kW-DC6.000 kW-ACPV-2FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------THIS SYSTEM DESIGNED WITH:WIND SPEED: 157WIND EXPOSURE: CSNOW LOAD: 0ROOF AREA: 2697 SQ FTSITE PLANLEGEND:CHIMNEYPIPE VENTMODULESCONDUITSETBACKAC DISCONNECTJUNCTION BOXINVERTERMAIN SERVICEPANELFUSED ACDISCONNECTACJBINVMSPFACGREG ALBRIGHTPACIFIC AVENUE166'-0"91'-10"166'-0"91'-10"58'-1"16'-6"14'-11"53'-9"ROOF LINEPROPERTY LINE(E) MAIN SERVICE PANEL(N) 31 HANWHA QCELL: Q.PLUSBFR-G4.1- 285W(N) JUNCTION BOXFENCE(N) SOLAREDGE SE6000H-USRGM [SI1]INVERTER WITH RAPID SHUTDOWN(N) UTILITY DISCONNECT EATONDG222NRB (OR EQUIVALENT) MSPACINVJBPV-2AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------ROOF PLANSCALE: 3/32" = 1'-0"1MODIFIED SETBACKS PROPOSED AT RIDGE:TOTAL ARRAY AREA = 557.38 SFTOTAL ROOF AREA = 2697 SFTOTAL ARRAY AREA AS A % TO ROOF AREA = 20.67%20.67% < 33%PV SYSTEM8.835 kW-DC6.000 kW-ACNOTES:1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TO THE RAIL.ROOF AREA: 2697 SQ FTTHIS SYSTEM DESIGNED WITH:WIND SPEED: 157WIND EXPOSURE: CSNOW LOAD: 0ROOF PLAN WITH MODULES LAYOUTLEGEND:CHIMNEYPIPE VENTMODULESCONDUITSETBACKAC DISCONNECTJUNCTION BOXINVERTERMAIN SERVICEPANELFUSED ACDISCONNECTACJBINVMSPFACGREG ALBRIGHT3'-0"3'-0" 3'-0"3'-0"4'-0"3'-0"4'-0"FIRE ACCESSPATHWAYS(E) MAIN SERVICE PANEL(N) 31 HANWHA QCELL: Q.PLUSBFR-G4.1- 285W(N) SOLAREDGE SE6000H-USRGM [SI1]INVERTER WITH RAPID SHUTDOWN(N) AC DISCONNECT EATON DG222NRB (OREQUIVALENT)(N) JUNCTION BOX2" X 4" TRUSSES @ 24" O.CATTACHMENT POINTS @ 48" O.C MAXFIRE ACCESSPATHWAYSFIRE ACCESSPATHWAYSFIRE ACCESSPATHWAYS ROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCHARRAY PITCHAZIMUTHROOF AREAARRAY AREA11726°26°271°869 SQ FT305.66 SQ FT21414°14°181°494 SQ FT251.72 SQ FTPV-2BFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------ROOF DETAILS:TOTAL ROOF AREA: 2697 SQ FTARRAY COVERAGE: 20.67%SYSTEM DISTRIBUTED WEIGHT: 2.28 LBSSFM INFINITY \ ROCKIT MICRORAIL POINT-LOAD: 12.23 LBSROOF DETAILSGREG ALBRIGHT ROOF DECK /MEMBRANESLIDER AND TRIMRAILROOF ATTACHMENTBUILDING STRUCTURE5/16" STAINLESS STEEL LAGBOLT OR STRUCTURAL SCREWWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHER2.5"TRIMRAIL2.5" MIN. EMBED.FLASHINGROOF / DECK MEMBRANESLIDERSBUILDING STRUCTURE5/16" STAINLESS STEELLAG BOLT ORSTRUCTURAL SCREWWITH 2-1/2" MIN.EMBEDMENT AND FLATWASHER2.5"MICRORAILFLASHING2.5" MIN. EMBED.HANWHA QCELL: Q.PLUSBFR-G4.1- 285WHANWHA QCELL: Q.PLUSBFR-G4.1- 285WSLIDERSMICRORAIL2.5" MIN. EMBED.5/16" STAINLESS STEEL LAGBOLT OR STRUCTURAL SCREWWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHERTRIMRAIL2.5" MIN. EMBED.FLASHINGFLASHINGSLIDER AND TRIMRAIL ROOFATTACHMENT2X4 TRUSS @ 24" O.C.ROOF / DECK MEMBRANE3" MIN.6" MAX.HANWHA QCELL: Q.PLUSBFR-G4.1- 285WATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPARTIAL ROOF FRAMING PLANScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------MOUNTING DETAILSGREG ALBRIGHT SOLAREDGE P401 POWER OPTIMIZERSJUNCTIONBOXSTRING-12 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#8 AWG MUST BE IN EMT CONDUITSTRING-2SOLAREDGE P401POWER OPTIMIZERS2 - #10 AWG,PV WIRE17 HANWHA QCELL: Q.PLUSBFR-G4.1- 285W14 HANWHA QCELL: Q.PLUSBFR-G4.1- 285W4 - #10 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUITUM(E) 200A / 2PMAIN BREAKER(END FED)(E) 200A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITYMETER(N) LINESIDE TAP VIA ULLISTED CONNECTORS1 - #6 GEC, BARE COPPERFREE AIR BONDEDEXISTING UFER TIE INTO UTILITYOVERHEADFEED3 - #8 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) 60A FUSEDAC DISCONNECTEATON DG222NRB (OREQUIVALENT)WITH 35A FUSES,KNIFEBLADE, LOCKABLE, NEMA3R, UL LISTED3 - #6 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMT CONDUIT(N) SOLAREDGESE6000H-USRGM [SI1]INVERTERACDCRAPIDSHUTDOWNSWITCHNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED FUSE SIZINGMAX. CONTINUOUS OUTPUT 25.00A @ 240V25.00X1.25=31AMPS35A FUSES - OKPV SYSTEM8.835 kW-DC6.000 kW-ACPV-4FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------THREE LINE DIAGRAMGREG ALBRIGHT PV-5FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------CONDUCTOR CALCULATIONSGREG ALBRIGHTWIRE SCHEDULERACEWAY#EQUIPMENTWIRE LOCATIONCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)STARTINGCURRENTAPPLIED TOCONDUCTORSIN RACEWAYTEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY1DCMODULETOOPTIMIZERROOF / FREE-AIR2104011.831140.0014.782DCOPTIMIZERTOJUNCTION BOXROOF / FREE-AIR2104015.001140.0018.753DCJUNCTION BOXTOINVERTEREXTERIOR WALL4104015.0010.832.0018.754ACINVERTERTOAC DISCONNECTEXTERIOR WALL385525.001155.0031.255ACAC DISCONNECTTOPOIEXTERIOR WALL367525.001175.0031.25CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------QTY.PARTPART #DESCRIPTION31MODULES111-285HANWHA QCELL: Q.PLUS BFR-G4.1- 285W31OPTIMIZERS130-401SOLAREDGE P401 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON1JUNCTION BOX480-276600VDC NEMA 3R UL LISTED JUNCTION BOX2CONNECTORS240-300STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)2CONNECTORS240-301STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)1INVERTER120-603SOLAREDGE SE6000H-USRGM [SI1] 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN1AC DISCONNECT323-06160A RATED 240VAC NEMA 3R UL LISTED2FUSES330-03535A FUSE 1 PH 240VAC1FUSE REDUCER330-53030A-60A FUSE REDUCER104ROOF ATTACHMENT 1261 -602SFM INFINITY \ ROCKIT MICRORAIL23SFM TRIM 1241-253FLASHKIT SFM / ROCK-IT TRIM COMP DARK59SFM SLIDER 1261-603FLASHKIT SFM / ROCK-IT SLIDER COMP DARK18BONDING CLAMP 1221-100N/S BONDING CLAMP7BONDING CLAMP 1241-404TRIM BONDING CLAMP33MOUNT ASSEMBLY 1241-405MLPE MOUNT ASSY19SFM SPLICE 1261-604SFM / ROCK-IT SPLICE5SFM ATTACHED SPLICE 1211-101ATTACHED SPLICE 8 INCH26TRIMRAIL 1261-606TRIMRAIL UNIV CLIP W/ HDW8TRIM SPLICE 1261-605TRIM SPLICE DRK14TRIMRAIL 1211-115TRIMRAIL UNIV DRK31GROUND LUG 1260-585ILSCO GROUND LUG31TRIM END CAPS 1221-200UNIRAC SFM / ROCK-IT TRIM END CAPSBREAKER SIZES:SERVICE LIST:NONEEQUIPMENT & SERVICE LISTGREG ALBRIGHT NOTES:M690.54705.12(B)(2)(3)(b)"WARNING"DUAL POWER SOURCESSECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 25.00 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSWARNING:POWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE.TURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAY690.56(C)(1)(A)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC 690.15, 690.54PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 25.00 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)INVERTERARRAYJ/BDC"WARNING"ELECTRICAL SHOCK HAZARD.TERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITION690.13 (B)690.53NEC 690.31(G)(3) & (4)PMPV METERSOLAR ELECTRICPV PANELSPV SYSTEM DC DISCONNECTMAXIMUM VOLTAGE: 480VMAXIMUM CIRCUIT CURRENT: 16.5AMAX RATED OUTPUT CURRENT OFTHE CONTROLLER OR DC-TO-DCCONVERTER: 15ATURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNENTIRE PV SYSTEMNFPA 11.12.2.1.1.1.1SOLAR ELECTRICPV PANELSEMERGENCY RESPONDERTHIS SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION.ONLY CONDUCTORS INSIDEBUILDING OR OFF THEROOF WILL SHUT DOWNNFPA 11.12.2.1.1.1.2SOLAR ELECTRICPV PANELSEMERGENCY RESPONDERTHIS SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWN"WARNING"PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESPV-7FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------LABELSGREG ALBRIGHT1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C.ARIAL FONT.3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWS CAUTION:PV-7AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDGREG ALBRIGHTWARNINGTURN OFF PHOTOVOLTAIC AC DISCONNECTPRIOR TO WORKING INSIDE PANELNPACIFIC AVENUEPOWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWNJUNCTION BOX31 PV MODULESMAIN SERVICE PANELAC DISCONNECTINVERTER EQUIPPEDWITH RAPID SHUTDOWN 123456789101-1011-2021-3031-4041-5051-60123456789101-1011-2021-3031-4041-5051-60PV-8FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------SOLAREDGE OPTIMIZER CHARTOPTIMIZER CHARTGREG ALBRIGHT SAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOBSTARTS AS PART OF THE PRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE& MAKE NOTES ON THE JHA SHEETIN CASE OF EMERGENCYNEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINICNAME: _______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATIONNAME: _______________________________________________PHONE NUMBER: _____________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THESAFETY PLAN AND SIGN INDICATING THAT THEY AREAWARE OF THE HAZARDS ON-SITE AND THE PLAN FORWORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OPV-9FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------SAFETY PLANGREG ALBRIGHT JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:124857DESIGNED BY:G.M.CLIENT:DIANE WALKER7103 PACIFIC AVENUE, FORT PIERCE, FL34951AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 240-9745SYSTEM:SYSTEM SIZE (DC): 31 X 285 = 8.835 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 31 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 31 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/10/2022---------SAFETY PLANGREG ALBRIGHT Q.PLUS BFR-G4.1 280-2901 APT test conditions: Cells at -1500 V against grounded, with conductive me-tal foil covered module surface, 25 °C, 168 h2 See data sheet on rear for further information.Q.ANTUM SOLAR MODULEThe new high-performance module Q.PLUS BFR-G4.1 is the ideal solution for all applications thanks to its innovative cell technology Q.ANTUM. The world-record cell design was developed to achieve the best performance under real conditions – even with low radiation intensity and on clear, hot summer days. LOW ELECTRICITY GENERATION COSTS Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 17.7 %.INNOVATIVE ALL-WEATHER TECHNOLOGYOptimal yields, whatever the weather with excellent low-light and temperature behavior.ENDURING HIGH PERFORMANCELong-term yield security with Anti-PID Technology1,Hot-Spot-Protect and Traceable Quality Tra.Q™.EXTREME WEATHER RATINGHigh-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC.MAXIMUM COST REDUCTIONSUp to 10 % lower logistics costs due to higher module capacity per box.A RELIABLE INVESTMENTInclusive 12-year product warranty and 25-year linear performance guarantee2. THE IDEAL SOLUTION FOR:Rooftop arrays on commercial / industrial buildingsRooftop arrays onresidential buildingsANTI PID TECHNOLOGY(APT)HOT-SPOT PROTECT(HSP)TRACEABLE QUALITY(TRA.Q™)YIELD SECURITY174 modules testedBest polycrystallinesolar module 2014Q.PRO-G2 235 MOD:27898photon.info/laboratory999Quality TestedID. 40032587high reliabilitylow degradationfrequentproduct surveillanceUL 1703; VDE Quality Tested; CE-compliant; IEC 61215 (Ed.2); IEC 61730 (Ed.1) application class ASpecifications subject to technical changes © Hanwha Q CELLS Q.PLUS BFR-G4.1_280-290_2016-08_Rev01_NAAt least 97 % of nominal power during first year. Thereafter max. 0.6 % degradation per year.At least 92 % of nominal power up to 10 years.At least 83 % of nominal power up to 25 years.All data within measurement tolerances.Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country.Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2).Hanwha Q CELLS America Inc.300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.usMECHANICAL SPECIFICATIONQ CELLS PERFORMANCE WARRANTYPERFORMANCE AT LOW IRRADIANCEIRRADIANCE [W/m²]RELATIVE EFFICIENCY [%] 200 400 600 800 10001101009080Format65.7 in × 39.4 in × 1.26 in (including frame)(1670 mm × 1000 mm × 32 mm)Weight41.45 lbs (18.8 kg)Front Cover0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technologyBack CoverComposite filmFrameBlack anodized aluminumCell6 × 10 Q.ANTUM solar cellsJunction box3.54-4.33 in × 2.99-3.03 in × 0.59-0.75 in (90-110 × 76-77 × 15-19 mm),Protection class IP67, with bypass diodesCable4 mm² Solar cable; (+) ≥ 39.37 in (1000 mm), (-) ≥ 39.37 in (1000 mm)ConnectorMC4, IP68PROPERTIES FOR SYSTEM DESIGNMaximum System Voltage VSYS[V]1000 (IEC) / 1000 (UL)Safety ClassIIMaximum Series Fuse Rating[A DC]20Fire RatingC (IEC) / TYPE 1 (UL)Design load, push (UL)2[lbs/ft2]75 (3600 Pa)Permitted module temperatureon continuous duty− 40 °F up to +185 °F(− 40 °C up to +85 °C)Design load, pull (UL)2[lbs/ft2]55.6 (2666 Pa)2 see installation manualQUALIFICATIONS AND CERTIFICATESPACKAGING INFORMATIONNumber of Modules per Pallet32Number of Pallets per 53' Container30Number of Pallets per 40' Container26Pallet Dimensions ( L × W × H )68.7 in × 45.3 in × 46.1 in(1745 × 1150 × 1170 mm)Pallet Weight1435 lbs (651 kg)NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]10095908580751552520010YEARS97Q CELLSIndustry standard for tiered warranties*Industry standard for linear warranties**Standard terms of guarantee for the 10 PV companieswith the highest production capacity in 2014 (as at: September 2014)DETAIL A0.630" (16 mm)0.335" (8.5 mm)0.965" (24.5 mm)Junction bo×Product label38.58" (980 mm)65.7" (1670 mm) 4 × Fastening points (DETAIL A)Cable withconnectorsFrame5.90" (150 mm)39.4" (1000 mm)37.44" (951 mm)1.26" (32 mm)8 × Drainage holes6 × Grounding points ø 0.177" (4.5 mm)39.37" (1000 mm)13.6“ (345 mm)ELECTRICAL CHARACTERISTICSPOWER CLASS280 285 290MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / -0 W)MinimumPower at MPP2PMPP[W]280 285 290Short Circuit Current*ISC[A]9.41 9.46 9.52Open Circuit Voltage*VOC[V]38.97 39.22 39.48Current at MPP*IMPP[A]8.84 8.91 8.98Voltage at MPP*VMPP[V]31.67 31.99 32.29Efficiency2Ș[%]≥ 16.8≥ 17.1 ≥ 17.4MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC3MinimumPower at MPP2PMPP[W]207.0 210.7 214.4Short Circuit Current*ISC[A]7.58 7.63 7.68Open Circuit Voltage*VOC[V]36.37 36.61 36.84Current at MPP*IMPP[A]6.93 6.99 7.05Voltage at MPP*VMPP[V]29.87 30.15 30.4211000 W/m², 25 °C, spectrum AM 1.5 G 2 Measurement tolerances STC ± 3 %; NOC ± 5 % 3 800 W/m², NOCT, spectrum AM 1.5 G * typical values, actual values may differCertifiedUL 1703(254141)TEMPERATURE COEFFICIENTSTemperature Coefficient of ISCĮ[% / K]+ 0.04Temperature Coefficient of VOCȕ[% / K]− 0.29Temperature Coefficient of PMPPȖ[% / K]− 0.40Normal Operating Cell TemperatureNOCT [°F]113 ± 5.4 (45 ± 3 °C) Power OptimizerFor North AmericaP370 / P400 / P401 / P485 / P50525YEARWARRANTYPV power optimization at the module-levelSpecifically designed to work with SolarEdgeinvertersUp to 25% more energySuperior efficiency (99.5%)Mitigates all types of module mismatch losses,from manufacturing tolerance to partialshadingFlexible system design for maximum spaceutilizationFast installation with a single boltNext generation maintenance with module-level monitoringMeets NEC requirements for arc faultprotection (AFCI) and Photovoltaic RapidShutdown System (PVRSS)Module-level voltage shutdown for installerand firefighter safetysolaredge.comPOWER OPTIMIZERPower OptimizerFor North AmericaP370 / P400 / P401 / P485 / P505Optimizermodel(typicalmodulecompatibility)P370(for higher-power 60and 72-cell modules)P400(for 72&96-cell modules)P401(for high power 60and72 cell modules)P485(for high-voltagemodules)P505(for highercurrent modules)INPUTRated Input DC Power(1)370400430485505WAbsolute Maximum Input Voltage(Voc at lowest temperature)60 80 60125(2)83(2)VdcMPPT Operating Range8-608-808-6012.5 - 10512.5 - 83VdcMaximum Short Circuit Current (Isc)1110.112.51114AdcMaximum DC Input Current13.7512.514.6512.517.5Maximum Efficiency99.5%Weighted Efficiency98.8%Overvoltage CategoryIIOUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)Maximum Output Current15AdcMaximum OutputVoltage6080VdcOUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)SafetyOutput Voltage per Power Optimizer1 ± 0.1VdcSTANDARD COMPLIANCEEMCFCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3SafetyIEC62109-1 (class II safety), UL1741, NEC/PVRSSMaterialUL94 V-0 , UV ResistantRoHSYesINSTALLATION SPECIFICATIONSMaximum Allowed System Voltage1000VdcCompatible invertersAll SolarEdge Single Phase and Three Phase invertersDimensions(W x L x H)129 x 153 x 27.5 /5.1x6x1.1129 x 153 x 33.5 /5.1 x 6 x 1.3129 x 153 x 29.5 /5.1x6x1.16129 x 159 x 49.5 /5.1 x 6.3 x 1.9129 x 162 x 59 /5.1 x 6.4 x 2.3mm/inWeight (including cables)630 / 1.4750 / 1.7655 / 1.5845 / 1.91064 / 2.3gr / lbInputConnectorMC4(3)MC4(3)MC4(3)Input Wire Length0.16 / 0.5m/ftOutput Wire Type / ConnectorDouble Insulated / MC4Output Wire Length1.2 / 3.9m/ftOperating Temperature Range(4)-40 to +85 / -40 to +185˚C/˚FProtection RatingIP68 / Type6BRelative Humidity0-100%(1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed(2) NEC 2017 requires max input voltage be not more than 80V(3) For other connector types please contact SolarEdge(4)Longer inputs wire lengths are available for use. For 0.9m input wire length order P401-xxxLxxx(5)For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdfPVSystem Design Using a SolarEdgeInverter(6)(7)Single PhaseHD-WaveSinglephaseThree Phase for208V gridThree Phase for277/480V gridMinimum String Length(Power Optimizers)P370, P400, P40181018P485, P5056814Maximum String Length (Power Optimizers)252550MaximumPower per String5700(8)(6000 withSE7600-US - SE11400-US)5250(8)6000(9)12750(10)WParallelStrings of Different Lengths or OrientationsYes(6)For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf(7)It is not allowed to mix P485/P505 with P370/P400/P401 in one string(8)A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement(9)For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W(10)For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc.All other trademarks mentioned herein are trademarks of their respective owners. Date: February 10, 2022DS-000044-NA. Subject to change withoutnotice. INVERTERS solaredge.comOptimized installation with HD-Wave technology6SHFLÀFDOO\GHVLJQHGWRZRUNZLWKSRZHURSWLPL]HUV%XLOWLQPRGXOHOHYHOPRQLWRULQJ2XWGRRUDQGLQGRRULQVWDOODWLRQ2SWLRQDO5HYHQXHJUDGHGDWD$16,&&ODVVDFFXUDF\5HFRUGEUHDNLQJHFLHQF\)L[HGYROWDJHLQYHUWHUIRUORQJHUVWULQJV,QWHJUDWHGDUFIDXOWSURWHFWLRQDQGUDSLGVKXWGRZQIRU1(&DQGSHUDUWLFOHDQG([WUHPHO\VPDOO8/6$FHUWLÀHGIRU&38&5XOHJULGFRPSOLDQFHSingle Phase Inverter with HD-Wave Technologyfor North America6(+866(+866(+866(+866(+866(+866(+8612-25YEARWARRANTYSE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-USOUTPUT Rated AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V7600 1000011400 @ 240V10000 @ 208VVAMaximum AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V7600 1000011400 @ 240V10000 @ 208VVAAC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)9999999VacAC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-9-9--9VacAC Frequency (Nominal)59.3 - 60 - 60.5(1)HzMaximum Continuous Output Current @240V12.5 16 21 25 32 42 47.5 AMaximum Continuous Output Current @208V-16-24- -48.5AGFDI Threshold1AUtility Monitoring, Islanding Protection, &RXQWU\&RQÀJXUDEOH7KUHVKROGVYesINPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 WMaximum DC Power @208V - 5100 - 7750 - - 15500 WTransformer-less, Ungrounded YesMaximum Input Voltage480 VdcNominal DC Input Voltage 380 400 VdcMaximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 AdcMaximum Input Current @208V(2)-9-13.5--27AdcMax. Input Short Circuit Current45 AdcReverse-Polarity ProtectionYesGround-Fault Isolation Detection 600k Sensitivity0D[LPXP,QYHUWHU(FLHQF\99 99.2 %&(&:HLJKWHG(FLHQF\9999 @ 240V98.5 @ 208V%Nighttime Power Consumption< 2.5 WADDITIONAL FEATURESSupported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20 Optional(3)Rapid Shutdown - NEC 2014 and 2017 690.12Automatic Rapid Shutdown upon AC Grid DisconnectSTANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI)EmissionsFCC Part 15 Class BINSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWGDC Input Conduit Size / # of Strings / AWG Range0D[LPXPᐎULQJV$:* 0D[LPXPᐎULQJV$:*Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185in / mmWeight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6OENJNoise < 25 <50 dBACoolingNatural ConvectionOperating Temperature Range -13 to +140 / -25 to +60(4)Ü)Ü&RSWLRQ(5)Ü)Ü&Protection Rating NEMA 4X (Inverter with Safety Switch)(1) For other regional settings please contact SolarEdge support (2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG (3) Revenue grade inverter P/N: SExxxxH-US000NNC2(4) For power de-rating information refer to: KWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI(5) -40 version P/N: SExxxxH-US000NNU4 SE3000H-USSE3800H-USSE5000H-USSE6000H-USSE7600H-USSE10000H-USSE11400H-USOUTPUTRated AC Power Output30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V76001000011400 @ 240V10000 @ 208VVAMaximum AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V76001000011400 @ 240V10000 @ 208VVAAC Output Voltage Min.-Nom.-Max.(211 - 240 - 264)9999999VacAC Output Voltage Min.-Nom.-Max.(183 - 208 - 229)-9-9--9VacAC Frequency (Nominal)59.3 - 60 - 60.5(1)HzMaximum Continuous Output Current @240V12.5162125324247.5AMaximum Continuous Output Current @208V-16-24--48.5AGFDI Threshold1AUtility Monitoring, Islanding Protection,&RXQWU\&RQÀJXUDEOH7KUHVKROGVYesINPUTMaximum DC Power @240V4650590077509300118001550017650WMaximum DC Power @208V-5100-7750--15500WTransformer-less, Ungrounded YesMaximum Input Voltage480VdcNominal DC Input Voltage380400VdcMaximum Input Current @240V(2)8.510.513.516.5202730.5AdcMaximum Input Current @208V(2)-9-13.5--27AdcMax. Input Short Circuit Current45AdcReverse-Polarity ProtectionYesGround-Fault Isolation Detection600k Sensitivity0D[LPXP,QYHUWHU(FLHQF\9999.2%&(&:HLJKWHG(FLHQF\9999 @ 240V98.5 @ 208V%Nighttime Power Consumption< 2.5WADDITIONAL FEATURESSupported Communication InterfacesRS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20Optional(3)Rapid Shutdown - NEC 2014 and2017 690.12Automatic Rapid Shutdown upon AC Grid DisconnectSTANDARD COMPLIANCESafetyUL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07Grid Connection StandardsIEEE1547, Rule 21, Rule 14 (HI)EmissionsFCC Part 15 Class BINSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range1" Maximum / 14-6 AWG1" Maximum /14-4 AWGDC Input Conduit Size / # of Strings / AWG Range0D[LPXPᐎULQJV$:*0D[LPXPᐎULQJV$:*Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 17421.3 x 14.6 x 7.3 / 540 x 370 x 185in / mmWeight with Safety Switch22 / 1025.1 / 11.426.2 / 11.938.8 / 17.6OENJNoise < 25<50dBACoolingNatural ConvectionOperating Temperature Range -13 to +140 / -25 to +60(4)Ü)Ü&RSWLRQ(5)Ü)Ü&Protection Rating NEMA 4X (Inverter with Safety Switch)(1) For other regional settings please contact SolarEdge support(2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG(3) Revenue grade inverter P/N: SExxxxH-US000NNC2(4) For power de-rating information refer to:KWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI(5) -40 version P/N: SExxxxH-US000NNU4Single Phase Inverterwith HD-Wave Technology for North America6(+866(+866(+866(+866(+866(+866(+866RODU(GJH7HFKQRORJLHV,QF$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF$OORWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH9(1*1$06XEMHFWWRFKDQJHZLWKRXWQRWLFH pe.eaton.com Eaton general duty cartridgefuse safety switchDG222NRBUPC:782113144221Dimensions:Height:14.37 IN●Length:7.35 IN●Width:8.4 IN●Weight:10 LBNotes:Maximum hp ratings apply only when dualelement fuses are used. 3-Phase hp rating shown isa grounded B phase rating, UL listed.Warranties: Eaton Selling Policy 25-000, one (1) year fromthe date of installation of the Product oreighteen (18) months from the date of shipmentof the Product, whichever occurs first.●Specifications:Type:General duty, cartridge fused●Amperage Rating:60A●Enclosure:NEMA 3R●Enclosure Material:Painted galvanized steel●Fuse Class Provision:Class H fuses●Fuse Configuration:Fusible with neutral●Number Of Poles:Two-pole●Number Of Wires:Three-wire●Product Category:General duty safety switch●Voltage Rating:240V●Supporting documents:Eatons Volume 2-Commercial Distribution●Eaton Specification Sheet - DG222NRB●Certifications: UL Listed●Product compliance:No Data______________________________________________________________________© 2016 Eaton. All rights reserved. The RockIt system is the industry’s premier rail-less PV racking system for composition shingle, tile, and metal roofs. Designed in conjunction with the needs of installers, RockIt quickly & easily installs with a single tool. Featuring an easy-to-position alignment slide and a top-down leveling system, RockIt is logistically intelligent with no need to ship or transport long rails. Components are DYDLODEOHLQDEODFNȴQLVKWKDWFRPSOHPHQWVERWKFRPPHUFLDOand residential applications. Conforms to UL 2703. FEATURES & BENEFITS• Patented watertight technology • Fully integrated bonding• Top-down leveling system•North-South adjustability• Single tool installCOMPLETE RAIL-LESS RACKING SYSTEMSTREAMLINED INSTALLATION WITH MINIMAL ROOF PENETRATIONSComposition Shingle, Tile, MetalRail-LessStructural-Attach Direct-AttachECOFASTENSOLAR.COMFRAME MLPE MOUNT Attaches and fully bonds MLPE’s (Module Level Power Electronics) to the module frame with a single bolt clip.COUPLING The fast installing RockIt Coupling easily attaches to the module frame to bridge the gaps between modules. ROCKIT SLIDEAvailable in three variations, the RockIt Slide allows installation on composition shingle, tile, and metal roofs.SKIRTThe sleek black Skirt installs first and acts as an alignment guide for the entire array. The Skirt End Cap does double duty as a skirt coupling device and an aesthetically-pleasing finishing touch.ROCKIT MOUNTFeaturing integrated bonding pins, the RockIt Mount connects to the Slide and can easily be positioned for fast installation. Features top-down leveling. Take your business to the next level with SFM INFINITY, UNIRAC’s rail-less PV mounting system for flush mount installations on comp shingle and tile roofs. An advanced 3rd generation product platform in use by top solar contractors nationwide, SFM INFINITY optimizes your operations on and off the roof, with approximately 40% less labor, 30% logistics savings, and 20% fewer roof attachments than traditional solar racking. Plus, 87% of homeowners prefer SFM INFINITY’s aesthetics.SUPERIOR PERFORMANCEEnhance your business with two installs per dayand 30% less cost.EASY INSTALLATIONPre-assembled components, 20% fewer roof attachments, and level array in seconds with post height adjustment. HOMEOWNER PREFERREDMore than 4 out of 5 homeowners prefer SFM INFINITY’S aesthetics over a leading rail brand.SFM INFINITYFRONT TRIM AND END CAPSUNIVERSAL COMPONENTSFIT 32 – 40MM MODULESEOWNERPREFERRED25 YEAR FULL-SYSTEM WARRANTYONE SKU FITS 32 TO 40mmREVOLUTIONIZING ROOFTOP SOLARFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702REVOLUTIONIZING ROOFTOP SOLARFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702SFM INFINITYDESIGN GUIDELINESAPPLICATION GUIDEWhile you will see advantages simply from switching to SFM INFINITY, the following guidelines will help you to maximize its benefits.When possible, design in landscape orientation in order to fit more modules on the roof and minimize roof attachments.DEFAULT TO LANDSCAPESFM INFINITY is easily configured in mixed array shapes and module orientations to maximize array density and to avoid vent pipes and other obstacles. Because mounting locations are not constrained by rails, SFM INFINITY has unmatched flexibility to enhance your projects.MIX MODULE ORIENTATIONSVisit UNIRAC’s mobile-friendly library of short, topic-specific videos which answer common questions and demonstrate how simple it is to install SFM INFINITY.CONSULT THE QUICK TIPS VIDEOSQuick Tips Videos: https://unirac.com/SFM-Infinity/ Layout your arrays in U-Builder, UNIRAC’s free solar design software, to optimize SFM INFINITY’S capabilities, including mixing module orientations and minimizing roof attachments. Quickly create layouts on Google or Bing Maps and generate project documents.DESIGN IN U-BUILDERU-Builder: https://design.unirac.com/ Report No. 102393982LAX-002Unirac, IncPage 2 of 107Issued: 11-Apr-2016Revised: 20-Mar-2019Product Brand nameModelsUnirac SFM2.0 Product DescriptionPhotovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20UniracDescriptionThe product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails within this product, whereas the 3" Micro Rail, Floating Splice, and 9" Attached Splice electrically bond the modules together forming the path to ground.The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate the anodized coating of the photovoltaic module frame to contact the metal, creating a bonded connection from module to module.The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition to thenational electrical codes. The Grounding Lug is secured to the photovoltaic module, torqued in accordance with the installation manual provided in this document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same engage cable.ED 16.3.15 (20-Apr-17) MandatoryReport No. 102393982LAX-002Unirac, IncPage 3 of 107Issued: 11-Apr-2016Revised: 20-Mar-20192.0 Product DescriptionModel SimilarityOther RatingsNAFuse Rating: 30AModule Orientation: Portrait or LandscapeMaximum Module Size: 17.98 ftϸUL2703 Design Load Rating:33 PSF Downward, 33 PSF Upward, 10 PSF Down-SlopeTested Loads - 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down SlopeTrina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical LoadingIncreased size ML test:Maximum Module Size: 22.3 ft²UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-SlopeLG355S2W-A5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24"UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope LG395N2W-A5, LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" Fire Class Resistance Rating:- Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at anyinterstitial gap. Installations must include Trim Rail.- Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at anyinterstitial gap. Installations must include Trim Rail.- Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules.This system was evaluated with a 5” gap between the bottom of the module and the roof’ssurfaceSee section 7.0 illustraction # 1 and 1a for a complete list of PV modules evaluated with these racking systemsRatingsNAED 16.3.15 (20-Apr-17) Mandatory AUTHORIZATION TO MARKApplicant: Manufacturer:Address: Address:Country: Country:Contact: Contact:Phone: Phone:FAX: FAX:Email: Email:Standard(s):Product:Brand Name:Models:This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.Intertek Testing Services NA Inc.545 East Algonquin Road, Arlington Heights, IL 60005Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1]Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20Unirac SFMUniracControl Number:5003705Authorized by: for Dean Davidson, Certification ManagerThis document supersedes all previous Authorizations to Mark for the noted Report Number.klaus.nicolaedis@unirac.comtoddg@unirac.comjia.liu@cxymj.combuwan.luo@cxymj.comParty Authorized To Apply Mark:Same as ManufacturerReport Issuing Office:Lake Forest, CA U.S.A.Klaus NicolaedisTom YoungJia LiuRobin Luo505-462-2190 505-843-1418+86-15267030962+86-13621785753NA NAUnirac, Inc Cixi Emeka Aluminum Co. Ltd1411 Broadway Blvd NEAlbuquerque, NM 87102No. 688 ChaoSheng RoadCixi CityZhejiang Province 315311USA ChinaThis authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)Covered section when made in accordance with the conditions set forth in the Certification Agreement and ListingReport. This authorization also applies to multiple listee model(s) identified on the correlation page of the ListingReport.This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may beapplied only at the location of the Party Authorized To Apply Mark.Page 1 of 1 ATM for Report 102393982LAX-002 ATM Issued: 9-Apr-2019ED 16.3.15 (20-Apr-17) Mandatory ĐŽ&ĂƐƚĞŶ^ŽůĂƌ>>ϰϭϰϭtsĂŶƵƌĞŶ^ƚ͕^ƚĞϮWŚŽĞŶŝdž͕ϴϱϬϬϵd>͗;ϴϳϳͿϴϱϵͲϯϵϰϳƚƚŶ͗͘ĐŽ&ĂƐƚĞŶ^ŽůĂƌ>>ͲŶŐŝŶĞĞƌŝŶŐĞƉĂƌƚŵĞŶƚ^ƵďũĞĐƚ͗ŶŐŝŶĞĞƌŝŶŐĞƌƚŝĨŝĐĂƚŝŽŶĨŽƌƚŚĞ^ƚĂƚĞŽĨ&ůŽƌŝĚĂƵŝůĚŝŶŐŽĚĞƐ͗ ϭ͘ ^ͬ^/ϳͲϭϲ͕DŝŶŝŵƵŵĞƐŝŐŶ>ŽĂĚƐĨŽƌƵŝůĚŝŶŐƐĂŶĚKƚŚĞƌ^ƚƌƵĐƚƵƌĞƐ͕ďLJŵĞƌŝĐĂŶ^ŽĐŝĞƚLJŽĨŝǀŝůŶŐŝŶĞĞƌƐϮ͘ ϮϬϮϬ&ͲƵŝůĚŝŶŐ͕ϳƚŚĚŝƚŝŽŶ͕ĂƐĞĚŽŶϮϬϭϴ/ŶƚĞƌŶĂƚŝŽŶĂůƵŝůĚŝŶŐŽĚĞϯ͘ ϮϬϮϬ&RͲZĞƐŝĚĞŶƚŝĂů͕ϳƚŚĚŝƚŝŽŶ͕ĂƐĞĚŽŶϮϬϭϴ/ŶƚĞƌŶĂƚŝŽŶĂůZĞƐŝĚĞŶƚŝĂůŽĚĞϰ͘ ϰϮϴ͕ĐĐĞƉƚĂŶĐĞƌŝƚĞƌŝĂĨŽƌDŽĚƵůĂƌ&ƌĂŵŝŶŐ^LJƐƚĞŵƐhƐĞĚƚŽ^ƵƉƉŽƌƚWŚŽƚŽǀŽůƚĂŝĐ;WsͿWĂŶĞůƐ͕EŽǀĞŵďĞƌϭ͕ϮϬϭϮďLJ/Ͳ^ϱ͘ ůƵŵŝŶƵŵĞƐŝŐŶDĂŶƵĂůϮϬϭϱ͕ďLJdŚĞůƵŵŝŶƵŵƐƐŽĐŝĂƚŝŽŶ͕/ŶĐ͘ϲ͘ E^/ͬtE^ͲϮϬϭϴ͕EĂƚŝŽŶĂůĞƐŝŐŶ^ƉĞĐŝĨŝĐĂƚŝŽŶĨŽƌtŽŽĚŽŶƐƚƌƵĐƚŝŽŶ͕ďLJƚŚĞŵĞƌŝĐĂŶtŽŽĚŽƵŶĐŝůĞƐŝŐŶƌŝƚĞƌŝĂ͗ ZŝƐŬĂƚĞŐŽƌLJ//^ĞŝƐŵŝĐĞƐŝŐŶĂƚĞŐŽƌLJсͲdžƉŽƐƵƌĞĂƚĞŐŽƌLJс͕ΘĂƐŝĐtŝŶĚ^ƉĞĞĚ;ƵůƚŝŵĂƚĞͿƉĞƌ^ϳͲϭϲсϵϬŵƉŚƚŽϭϴϬŵƉŚ'ƌŽƵŶĚ^ŶŽǁ>ŽĂĚсϬƚŽϲϬ;ƉƐĨͿdŚŝƐůĞƚƚĞƌĐĞƌƚŝĨŝĞƐƚŚĂƚƚŚĞůŽĂĚŝŶŐĐƌŝƚĞƌŝĂĂŶĚĚĞƐŝŐŶďĂƐŝƐĨŽƌƚŚĞĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵ^ƉĂŶdĂďůĞƐĂƌĞŝŶĐŽŵƉůŝĂŶĐĞǁŝƚŚƚŚĞĂďŽǀĞĐŽĚĞƐ͘/ĨLJŽƵŚĂǀĞĂŶLJƋƵĞƐƚŝŽŶƐŽŶƚŚĞĂďŽǀĞ͕ĚŽŶŽƚŚĞƐŝƚĂƚĞƚŽĐĂůů͘WƌĞƉĂƌĞĚďLJ͗W^͕/ŶĐ͘ʹ^ƚƌƵĐƚƵƌĂůŶŐŝŶĞĞƌƐZŽƐĞǀŝůůĞ͕DĂLJϮϭ͕ϮϬϮϭW^͕/ŶĐ͘ʹ^ƚƌƵĐƚƵƌĂůŶŐŝŶĞĞƌƐŚĂƐƉƌŽǀŝĚĞĚĞŶŐŝŶĞĞƌŝŶŐĂŶĚƐƉĂŶƚĂďůĞƐĨŽƌƚŚĞĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵ͕ĂƐƉƌĞƐĞŶƚĞĚŝŶW^ZĞƉŽƌƚηϮϬϭϱͲϬϱϴϴϰ,'͘Ϭϳ͘Ϭϭ͕ΗŶŐŝŶĞĞƌŝŶŐĞƌƚŝĨŝĐĂƚŝŽŶĨŽƌƚŚĞĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵĨŽƌ'ĂďůĞĂŶĚ,ŝƉZŽŽĨƐΗ͘ůůŝŶĨŽƌŵĂƚŝŽŶ͕ĚĂƚĂ͕ĂŶĚĂŶĂůLJƐŝƐƚŚĞƌĞŝŶĂƌĞďĂƐĞĚŽŶ͕ĂŶĚĐŽŵƉůLJǁŝƚŚ͕ƚŚĞĨŽůůŽǁŝŶŐďƵŝůĚŝŶŐĐŽĚĞƐĂŶĚƚLJƉŝĐĂůƐƉĞĐŝĨŝĐĂƚŝŽŶƐ͗ZĞ͗ZĞƉŽƌƚηϮϬϭϱͲϬϱϴϴϰ,'͘Ϭϳ͘ϬϭʹĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵĨŽƌ'ĂďůĞĂŶĚ,ŝƉZŽŽĨƐEXP. 02/28/2023ZACHERPAULK.ENSECILARIDAOLFNOISSEFORP LENGINEERSTATE OFNo. 7352205/21/2021THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY PAULK. ZACHER, PE ON 05/21/2021 USING A SHA-1 AUTHENTICATION CODE.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNEDAND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST BEVERIFIED ON ANY ELECTRONIC COPIES. U-BUILDER PROJECT REPORT VERSION: 3.1.6 PROJECT TITLE SFM Infinity PROJECT ID 22EDDD12 CREATED March 10, 2022, 1:32 p.m. NAME Walker, Diane ADDRESS 7103 Pacific Avenue, Fort Pierce, FL 34951 CITY, STATE Fort Pierce, FL MODULE Custom Custom Designed by gimartinez@freedomforever.com SFM Infinity Custom 31 - Custom 557.26 ft 8.99 KW 2 UNVALIDATED MODULE SIZE: The module selected was based on a typical or custom module size. DO NOT USE this information to purchase or install without verifying the exact module dimensions. ENGINEERING REPORT * Distributed Dead Load 2.71 psf * Average Roof Point Dead Load 13.13 lbs Plan review TOTAL NUMBER OF MODULES 31 TOTAL KW 8.99 KW TOTAL MODULE AREA 557.26 ft NS DIMENSION 23.38 ft EW DIMENSION 65.96 ft Loads Used for Design BUILDING CODE ASCE 7-16 BASIC WIND SPEED 160.00 mph GROUND SNOW LOAD 0.00 psf SEISMIC (SS)0.05 ELEVATION 21.00 ft WIND EXPOSURE C TOPOGRAPHICAL FACTOR KZT 1.00 2 Inspection PRODUCT SFM Infinity MODULE MANUFACTURER Custom MODEL Custom MODULE WATTS 290 watts MODULE LENGTH 65.75" MODULE WIDTH 39.37" MODULE THICKNESS 1.26" MODULE WEIGHT 40.79 lbs BUILDING HEIGHT 15.00 ft ROOF TYPE Shingle RAFTER SPACING 24.00" TOTAL WEIGHT 1510.06 lbs 34951Loads Determined by Zip CITY, STATE Fort Pierce, FL BASIC WIND SPEED 145.00 mph GROUND SNOW LOAD 0.00 psf * Calculated based on suggested quantity given on part list. Environmental conditions may exceed Ubuilder parameters for attachment parts in 2n, 2r, 3e. Please review and modify your design or consult Unirac Engineering Services for more information. Environmental conditions may exceed Ubuilder parameters for trim in 2n, 2r, 3e. Please review and modify your design or consult Unirac Engineering Services for more information. Roof Area 1 / Roof Area 1 - Array 1 Landscape Modules Environmental conditions may exceed Ubuilder parameters for attachment parts in 3r. Please review and modify your design or consult Unirac Engineering Services for more information. Environmental conditions may exceed Ubuilder parameters for trim in 3r. Please review and modify your design or consult Unirac Engineering Services for more information. SFM MICRORAIL SPANS [IN] 1, 2E 2N, 2R, 3E 3R DESIGN SPAN (NON-EXPOSED) 48 24 24 DESIGN SPAN (EXPOSED) 24 24 NG Max Overhang (Non-Exposed) 21 10 8 Max Overhang (Exposed) 10 8 NG Max Span (Non-Exposed) 64 32 24 Max Span (Exposed) 32 24 NG MICRORAIL DESIGN PRESSURES [PSF] 1, 2E 2N, 2R, 3E 3R Up (Non-Exposed) -23.0 -39.3 -53.7 Up (Exposed) -36.7 -62.2 -81.3 Down 12.2 12.2 12.2 Downslope 1.4 1.4 1.4 Lateral 0.1 0.1 0.1 MICRORAIL MAXIMUM POINT LOADS [LBS] 1, 2E 2N, 2R, 3E 3R Up (Non-Exposed) -301.3 -259.4 -354.4 Up (Exposed) -242.2 -410.5 -536.6 Down (Non-Exposed) 159.8 80.5 80.5 Down (Exposed) 80.5 80.5 80.5 Downslope (Non-Exposed) 18.3 9.2 9.2 Downslope (Exposed) 9.2 9.2 9.2 Lateral (Non-Exposed) 1.3 0.7 0.7 Lateral (Exposed) 0.7 0.7 0.7 Tributary Area (Non-Exposed) 13.1 6.6 6.6 Tributary Area (Exposed) 6.6 6.6 6.6 SFM TRIM RAIL SPANS [IN] 1, 2E 2N, 2R, 3E 3R DESIGN SPAN (NON-EXPOSED) 48 24 24 DESIGN SPAN (EXPOSED) 24 24 NG Max Overhang (Non-Exposed) 24 10 8 Max Overhang (Exposed) 10 8 NG Max Span (Non-Exposed) 72 32 24 Max Span (Exposed) 32 24 NG TRIM RAIL DESIGN PRESSURES [PSF] 1, 2E 2N, 2R, 3E 3R Up (Non-Exposed) -24.0 -41.0 -59.7 Up (Exposed) -36.7 -62.2 -90.3 Down 12.4 12.4 12.4 Downslope 1.4 1.4 1.4 Lateral 0.1 0.1 0.1 TRIM RAIL MAXIMUM POINT LOADS [LBS] 1, 2E 2N, 2R, 3E 3R Up (Non-Exposed) -158.4 -135.3 -197.0 Up (Exposed) -121.1 -205.3 -298.0 Down (Non-Exposed) 81.8 40.9 40.9 Down (Exposed) 40.9 40.9 40.9 Downslope (Non-Exposed) 18.3 9.2 9.2 Downslope (Exposed) 9.2 9.2 9.2 Lateral (Non-Exposed) 0.7 0.3 0.3 Lateral (Exposed) 0.3 0.3 0.3 Tributary Area (Non-Exposed) 6.6 3.3 3.3 Tributary Area (Exposed) 3.3 3.3 3.3 Spans and overhangs listed above are calculated per ASCE 7-16 roof areas. Please see the SFM Infinity Installation Guide and Design and Engineering Guide for installation rules and details for your installation based on your roof-specific conditions. Environmental conditions may exceed Ubuilder parameters for attachment parts in 2n, 2r, 3e. Please review and modify your design or consult Unirac Engineering Services for more information. Environmental conditions may exceed Ubuilder parameters for trim in 2n, 2r, 3e. Please review and modify your design or consult Unirac Engineering Services for more information. Environmental conditions may exceed Ubuilder parameters for attachment parts in 3r. Please review and modify your design or consult Unirac Engineering Services for more information. Environmental conditions may exceed Ubuilder parameters for trim in 3r. Please review and modify your design or consult Unirac Engineering Services for more information. Roof Area 2 / Roof Area 2 - Array 1 Landscape Modules Spans and overhangs listed above are calculated per ASCE 7-16 roof areas. Please see the SFM Infinity Installation Guide and Design and Engineering Guide for installation rules and details for your installation based on your roof-specific conditions. SFM MICRORAIL SPANS [IN] 1, 2E 2N, 2R, 3E 3R DESIGN SPAN (NON-EXPOSED) 48 24 24 DESIGN SPAN (EXPOSED) 24 NG NG Max Overhang (Non-Exposed) 18 8 8 Max Overhang (Exposed) 8 NG NG Max Span (Non-Exposed) 48 24 24 Max Span (Exposed) 24 NG NG MICRORAIL DESIGN PRESSURES [PSF] 1, 2E 2N, 2R, 3E 3R Up (Non-Exposed) -31.0 -47.3 -59.6 Up (Exposed) -49.3 -74.9 -90.2 Down 12.4 12.4 12.4 Downslope 0.8 0.8 0.8 Lateral 0.1 0.1 0.1 MICRORAIL MAXIMUM POINT LOADS [LBS] 1, 2E 2N, 2R, 3E 3R Up (Non-Exposed) -406.1 -312.2 -393.4 Up (Exposed) -325.4 -494.3 -595.3 Down (Non-Exposed) 162.4 81.8 81.8 Down (Exposed) 81.8 81.8 81.8 Downslope (Non-Exposed) 10.5 5.3 5.3 Downslope (Exposed) 5.3 5.3 5.3 Lateral (Non-Exposed) 1.3 0.7 0.7 Lateral (Exposed) 0.7 0.7 0.7 Tributary Area (Non-Exposed) 13.1 6.6 6.6 Tributary Area (Exposed) 6.6 6.6 6.6 SFM TRIM RAIL SPANS [IN] 1, 2E 2N, 2R, 3E 3R DESIGN SPAN (NON-EXPOSED) 24 24 24 DESIGN SPAN (EXPOSED) 24 NG NG Max Overhang (Non-Exposed) 10 8 8 Max Overhang (Exposed) 8 NG NG Max Span (Non-Exposed) 32 24 24 Max Span (Exposed) 24 NG NG TRIM RAIL DESIGN PRESSURES [PSF] 1, 2E 2N, 2R, 3E 3R Up (Non-Exposed) -32.3 -49.3 -59.6 Up (Exposed) -49.3 -74.9 -90.2 Down 13.9 13.9 13.9 Downslope 0.8 0.8 0.8 Lateral 0.1 0.1 0.1 TRIM RAIL MAXIMUM POINT LOADS [LBS] 1, 2E 2N, 2R, 3E 3R Up (Non-Exposed) -106.6 -162.7 -196.7 Up (Exposed) -162.7 -247.2 -297.7 Down (Non-Exposed) 45.9 45.9 45.9 Down (Exposed) 45.9 45.9 45.9 Downslope (Non-Exposed) 10.5 5.3 5.3 Downslope (Exposed) 5.3 5.3 5.3 Lateral (Non-Exposed) 0.3 0.3 0.3 Lateral (Exposed) 0.3 0.3 0.3 Tributary Area (Non-Exposed) 3.3 3.3 3.3 Tributary Area (Exposed) 3.3 3.3 3.3 SFM Infinity Product Assumptions Limitations of Responsibility: It is the user’s responsibility to ensure that inputs are correct for your specific project. Unirac is not the solar, electrical, or building engineer of record and is not responsible for the solar, electrical, or building design for this project. Allowable spans and resulting point loads are subject to the following conditions: 1. Building Height ≤ 60 ft unless otherwise specified. 2. Roof Slope ≥ 1.2° 3. Maximum rail cantilever ≤ 1/3 of selected span. 4. Occupancy/Risk Category = II unless otherwise specified. 5. ASCE 7-05: Basic Wind Speed: 85-170 mph (IBC 2006/ASCE 7-05). Wind Exposure: B, C or D. 6. ASCE 7-10: Basic Wind Speed: 95-190 mph (IBC 2012/ASCE 7-10). Wind Exposure: B, C or D. 7. ASCE 7-16: Basic Wind Speed: 85-190 mph (IBC 2018/ASCE 7-16). Wind Exposure: B, C or D. 8. Ground Snow Load: 0-100 psf. (Reduction can be input if this is acceptable with your local building authority). Results are based on uniform snow loading and do not consider unbalanced, drifting, and sliding conditions. 9. Dead Load ≤ 5 psf (includes PV Modules and Racking). 10. Maximum PV Module Length: 85 in. 11. Seismic: Installations must be in seismic site class A, B, C, or D as defined in IBC 2006/ASCE 7-05. 12. Intermediary Span Distances: Roof attachment point loads be reduced linearly if the installed distance between the attachments is less than the selected span. For example, if the spacing is half the amount shown in the results, then the point loads may also be reduced by half. 13. Spans greater than 96 in.: While our products are valid for greater spans in many instances, we do not recommend this mounting configuration. Typical residential roofs are not designed for the larger point loads that might result from such excessive spans and we recommend final design by a licensed professional engineer of responsible charge. Pitched Roof Solutions (Flush Mounted Solutions): Modules are parallel to the roof surface and within 10 in. of it. Allowable roof pitch: 1.2°-45°. Building has a monoslope roof with a slope ≤ 3°, a gable roof ≤ 45°, or a hip roof ≤ 27°.