Loading...
HomeMy WebLinkAbout10360 Richey Engineering 03-18-22d%SSLING NCONSULTING 4 Scott E. Wyssling, PE Jon P. Ward, SE, PE Gregory T. Elvestad, PE March 18, 2022 76 North Meadowbrook Drive Alpine, UT 84004 office (201) 874-3483 swyssling@wysslingconsulting.com Jacob Humpherys, COO Digitally signed ned to ,L=Alcott ine,OWyssWyssl DN: C=US, S=Utah, L=Alpine, O=Wyssling Consulting, CN="Scott E Wyssling, PE", Meraki Solutions ScottEWyssling PEE=swyssling the author of thisnocum Reason: am the author of this document 30700 Wekiva River Road Location: your signing location here Date: 2022.03.18 00:53:17-04'00' Sorrento, FL 32776 Foxit PhantomPDF Version: 10.1.3 Re: Engineering Services Richey Residence 7806 Deer Park Avenue, Fort Pierce FL 11.560 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Prefabricated wood trusses with all dimensional lumber at 24" on center. Roof Material: Metal roofing Roof Slope: 22 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF truss members constructed of 2 x 4 • Live Load = 20 psf (reducible) — 0 psf at locations of solar panels • Ground Snow Load = 0 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 160 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the FBC 2020 7t" Edition, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "S-5 Installation Manual", which can be found on the S-5 website (http://s-5.com/). If during solar panel installation, the roof framing members appear unstable or deflect non -uniformly, our office should be notified before proceeding with the installation. 2. System will be attached to the metal roofing material utilizing the patented S-5 connection. Installation of the connections shall be in accordance with the manufacturer's recommendations. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed no greater than 48" o/c. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the FBC 2020 7lh Edition, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Auly yours, �% Scott E. Wyssli , PE Florida License No. t W YSS J% No 1558 STATE OF ` Wyssung Consulting, PLLC 75 N Meadowhrook Drive Alpine UT 84004 COA p RY34912 TlilS PLAN HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY SCOTT WYSSLING, PE USII4G A DIGrFAL SIGNATURE AND DATE. PRINTED COPIES OF T1 ]IS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND TIfE SIGNATURE MUST BE VERIFIED ON MN FI ff :TRO1I C C.OPIFS Date Signed 3/18/2022 C SUL NG CONSULTING GENERAL NOTES 1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. 2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. 3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.81 6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.311 7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. STREET VIEW: .p . STATE OF f PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONSC4RSDe• EQUIPMENT: AC SYSTEM SIZE: 10 kW AC WyssiingConsulting, PLLC 76 N McBdowfirook Drive DC SYSTEM SIZE: 11.56 kW DC Alpine UT94004 COA4RY34912 (34) Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W PV ii', ✓Ukr.>ijFzENELEcrROtAICALLYS (1) SolarEdge SE10000H-US (240V) INVERTER(S) :,, :fT DATE. PRINTSLING, D COPIES:! Al: :;! ;A i �.}421 :+� lU DATE PRINTED COPIES :I RACKING: S-5. - PROTEA BRACKET SEALEDOCUlE3d DTHES:ARE TCONSIDEREDSIGNfu I SEALED AND THE SfGNATURE MUST 8E VI ON ANY ELECTRONIC COPIES I APPLICABLE GOVERNING CODES SITE SPECIFICATIONS 2017 NEC OCCUPANCY: R-3 2020 FBC 7th Edition, Building ZONING: RESIDENTIAL 2020 FBC 7th Edition, Residential 2020 FBC 7th Edition, Existing Building MEFRAKI ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 SITE INFORMATION Blake Richey 7806 Deer Park Ave Fort Pierce, FL 34951 AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 11.56 kW DC Lat, 27.5404594 Long,-80.4041132 4) Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W PV MODULES 1) SolarEdge SE1000OH-US (240V) INVERTER(S) Florida Power & Light SHEET INDEX: PV01 COVER PAGE PV02 SITE PLAN PV03 ROOF ATTACHMENTS "VO4 MOUNTING DETAIL PV05 LINE DIAGRAM PV06 ELECTRICAL CALCS PV07 LABELS PV08 PLACARD PV09 SITE PHOTOS DRAWN BY: SoloCAD DATE: March 15, 2022 COVER PAGE - PV01 MP4 CLOSE UP OF HOME FRONT OF HOME MP2 EQUIPMENT LEGEND: UTILITY METER Ac AC VISABLE, LOCKABLE, LABELED Ilvv INVERTER suB SUB PANEL DISCMSP NNECT MAIN SERVICE PANEL Pv (FOR ETER SOCKILITY T METER) E COMBINER BOX Lc LOAD CENTER ARRAY DETAILS: MOUNTING PLANE: AZIMUTH: TILT: MP1 360' 22° MP2 90° 22° MP3 180' 22° MP4 270' 22° _ 90.1011 128'-T ® FIRE ACCESS PATHWAY (3' TYP) PROPERTY LINE FRONT OF HOME 7806 Deer Park Ave BAIT BATTERY(IES) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER MERAK ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 SITE INFORMATION Blake Richey 7806 Deer Park Ave Fort Pierce, FL 34951 AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 11.56 kW DC Lat, 27.5404594 Long,-80.4041132 (34) Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W PV MODULES (1) SolarEdge SE10000H-US (240V) INVERTER(S) FIa}�'asE'Wr55G` Light 7 — .� . STATE OF Al. S�DNAIL 10 ``` U110,1 Wyssiing Consulting, PLLC 16 N Meadowdrook Drive Alpine UT $4004 COA # RY34912 IIS PLAN HAS BEEN ELECTRONICALLY SIGNED AND ALED BY SC.OTT WYSSLING. PE USING A DIGITAL 3NATURE AND DATE. PRINTED COPIES OF THIS ?CLIMENT ARE NOT COUSIDER£D SIGNED AND ALED AND THE SIGNATURE MUST BE VERIFIED ! ANY FLFCTRONIC COPIES DRAWN BY: SoloCAD DATE: March 15, 2022 SITE PLAN - PV02 ME SCREW ATTACHMENT DETAILS FOR PROTEA BRACKET UNIVERSAL FASTENING OBJECT PV MODULE FRAME RAIL MID CLAMP DETAILS 1/4" (6.3mm) Diameter 1" (25mm) Length Stainless Steel Self Tapping Screw with Hardened Steel Piercing Point 5/16" (8mm) Hex Head 5/8" (16mm) Stainless Steel/EPDM Sealing Washer V MODULE, Y OTHERS n' ATTACHMENT )RRUGATED =TAL ROOF DETAIL, MOUNTING AND FLASHING EQUIPMENT INFORMATION: RAIL MANUFACTURER: Iron Ridge RAIL PART NUMBER: XR-100 ATTACHMENTS S-5! - PROTEA BRACKET ATTACHMENT CITY: 75 SPLICE CITY: 10 MIDCLAMP CITY: 52 ENDCLAMP CITY: 32 ROOF INFO: ROOF TYPE: ROOF FRAMING: RAFTER/TOP CHORD SIZE: RAFTER/TOP CHORD SPACING: ATTACHMENT SPACING: UNIVERSAL FASTENING OBJECT 1 1'-8" MAX. PITCH 2'-8" MIN - 3'-10" MAX 2 PV MODULE RAIL 48" MAX." RAIL ATTACHMENT SIDE VIEW 3 2'-8" MIN - T-10" MAX ATTACH M ENT FRONT VIEW PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: Trap Metal PV MODULE COUNT: 34 Manufactured Truss ARRAY AREA: MODULE COUNT * 19.29 ft2 = 655.86 2x4 ROOF AREA: 1838 ft2 24" PERCENT OF ROOF COVERED: 36% 48" ARRAY WEIGHT: MODULE COUNT * 44 Ibs = 1496 Ibs DISTRIBUTED LOAD: ARRAY LBS/ATTACHMENTS = 19.95 POINT LOAD: (Ibs/ft2) (ARRAY) WEIGHT/AREA = 2.28 Ibs/ft2 MERAKI ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 SITE INFORMATION Blake Richey 7806 Deer Park Ave Fort Pierce, FL 34951 AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 11.56 kW DC Lat, 27.5404594 Long,-80.4041132 (34) Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W PV MODULES (1) SolarEdge SE10000H-US (240V) INVERTER(S) FI A aE 'W YS. Light - .� . STATE OF Al. S�DNAIL jImil' "'1 0 Wyssiing Consulting, PLLC 16 N Meadowdrook Drive Alpine UT $4004 COA # RY34912 S PLAN HAS BEEN ELECTRONICALLY SIGNED AND 1LED BY SC.OTT WYSSLING. PE USING A DIGITAL NATURE AND DATE. PRINTED COPIES OF THIS :UMENT ARE NOT CONSIDERED SIGNED AND U-E❑ AND THE SIGNATURE MUST BE VERIFIED ANY FLFCTRONIC COPIES DRAWN BY: SoloCAD DATE: March 15, 2022 MOUNTING DETAIL - PV04 Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W Specs POWER MAX (PMAX): 340W OPEN CIRCUIT VOLTAGE (VOC): 40.66V MAX POWER -POINT CURRENT (IMP): 10.02A MAX POWER -POINT VOLTAGE (VMP): 33.94V SHORT CIRCUIT CURRENT (ISC): 10.52A SERIES FUSE RATING: 20A STRING (1): 15.0 A DC SolarEdge SE1000OH-US (240V) Specs MAX INPUT VOLTAGE: 480 V MAX INPUT CURRENT: 27 A NOMINAL DC INPUT VOLTAGE: 400 V MAXIMUM OUTPUT POWER: 10000 W NOM. OUTPUT VOLTAGE: 240 V MAX OUTPUT CURRENT: 42 A 1-Phase, 60 HZ, UL 1741 Listed Equipment Schedule TYPE: CITY: DESCRIPTION: RATING: MODULES: (34) Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W 340 W INVERTERS: (1) SolarEdge SE1000OH-US(240V) 10000 W AC DISCONNECTS: (1) PV AC Disconnect, 240V, 2-Pole 60 A DC OPTIMIZERS: (34) SolarEdge P370 15 Adc SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2017, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING- MAXIMUM NUMBER OF MODULE STRINGS. MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER. Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE (2) 10 AWG PV-WIRE, USE-2, COPPER (Ll, L2) 1 (1) 6AWG THWN-2COPPER -(GROUND) N/A -FREE AIR 2 (2) 10 AWG THWN-2, or COPPER - (L1, L2) 3/4" EMT (1) 10 AWG THWN-2COPPER -(GROUND) (6) 10 AWG THHN/THWN-2, COPPER - (L1, L2) 3/4" EMT 3 (1) 10 AWG THWN-2COPPER -(GROUND) (3) 6 AWG THWN-2 COPPER - (1-1, L2, NEUTRAL) 3/4" 4 (1) 10 AWG THWN-2COPPER -(GROUND) EMT (E) GROUNDING /� (E) UTILITY METER ELECTRODE VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER MERAK ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 SITE INFORMATION Blake Richey 7806 Deer Park Ave Fort Pierce, FL 34951 AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 11.56 kW DC Lat, 27.5404594 Long,-80.4041132 (34) Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W PV MODULES (1) SolarEdge SE10000H-US (240V) INVERTER(S) FIaosE'Wr55G`� Light 7 — .� . STATE OF D �C0RIDa;'��. "',I,S/DNML' `` "jIir Ir+t<<oi� Wyssiing Consulting, PLLC 76 N Meadowdrook Drive Alpine UT $4004 COA # RY34912 S PLAN HAS BEEN ELECTRONICALLY SIGNED AND ILED BY SC.OTT VVYSSLING. PE USING A DIGITAL NATURE AND DATE. PRINTED COPIES OF THIS :UMENT ARE NOT CONSIDERED SIGNED AND ILE❑ AND THE SIGNATURE MUST BE VERIFIED ANY ELEC TRONTC! COPIES DRAWN BY: SoloCAD DATE: March 15, 2022 LINE DIAGRAM - PV05 STRING CALCULATIONS SolarEdge SE1000OH-US (240V) STRING #1 STRING #2 STRING #3 OPTIMIZER MAX OUTPUT CURRENT 15A 15A 15A OPTIMIZERS IN SERIES: 12 11 11 NOMINAL STRING VOLTAGE: 400V 400V 400V ARRAY OPERATING CURRENT: 10A 9A 9A ARRAY DC POWER: 11560W TOTAL MAX AC CURRENT: 42A NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES 4-6 .80 7-9 .70 10-20 .50 SYSTEM OCPD CALCULATIONS INVERTER MODEL(S): SolarEdge SE10000H-US (240V) # OF INVERTERS: 1 MAX OUTPUT CURRENT: 42A (# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING (1 X 42A X 1.25) = 52.5A <= 60A, OK BUSBAR CALCULATIONS - 120% RULE MAIN BUSBAR RATING: 200A MAIN DISCONNECT RATING: 150A PV BREAKER RATING: 60A (MAIN BUS RATING X 120%) - MAIN DISCONNECT RATING >= OCPD RATING (200A X 1.2) - 150A = 90A, >= 60A, OK Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE CONDUCTOR RATING CONDUCTOR TEMP. RATE AMBIENTTEMP TEMP. DERATE # OF CONDUCTORS DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL 1 (2) 10 AWG PV-WIRE, USE-2, COPPER (1-1, L2) N/A - FREE AIR 40A 90°C 330C 0.96 N/A - FREE AIR 38AA N/A - FREE AIR (1) 6 AWG THWN-2 COPPER - (GROUND) 2 (2) 10 AWG THWN-2, or THHN COPPER - (1-1, L2) 3/4" EMT 40A 90°C 33°C 0.96 1 38.4A 11.9% (1) 10 AWG THWN-2 COPPER - (GROUND) 3 (6) 10 AWG THHN/THWN-2, COPPER - (1-1, L2) 3/4" EMT 40A 90°C 33°C 0.96 0.8 30.72A 27.8% (1) 10 AWG THWN-2 COPPER - (GROUND) 4 (3) 6 AWG THWN-2 COPPER - (1-1, L2, NEUTRAL) 3/4" EMT 65A 75°C 33'C 0.96 1 62.4A 32.6% (1) 1 10 AWG I THWN-2 COPPER - (GROUND) GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE. 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.64]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH MERAKI ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 SITE INFORMATION Blake Richey 7806 Deer Park Ave Fort Pierce, FL 34951 AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 11.56 kW DC Lat, 27.5404594 Long,-80.4041132 (34) Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W PV MODULES (1) SolarEdge SE10000H-US (240V) INVERTER(S) Flor, da,'o'ss~uw & Ligh wYt a�j E F. -p. STATE OF 7� Wyssling Consulting, PLLC 76 N Meadow6rook Drive Alpine VT $4004 COA k RY34912 5 PLAN H&S BEEN ELECTRONICALLY SIGNED AND ILED BY SCOTT WYSSLING, PE USING A DIGITAL NATURE AND DATE. PRINTED COPIES OF THIS :UMENT ARE NOT CONSIDERED SIGNED AND ILED AND THE SIGNATURE. MUST BE VERIFIED AFJY FLFCTRONIC COPIES DRAWN BY: SoloCAD DATE: March 15, 2022 ELECTRICAL CALCS - PV06 /I\ WARNING ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION /1\ WARNING J THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. A\ WARNING A INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE /!\ WARNING A 1 DUAL POWER SUPPLY I SOURCES: UTILITY GRID AND PV I SOLAR ELECTRIC SYSTEM LABEL 1 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] LABEL 2 PLACED ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(b)] LABEL 3 PLACED ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(13)(2)(3)(c)] LABEL 4 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO MAIN SERVICE PANEL INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.12(B)(3)] LABELS AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.11 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SOLAR ELECTRIC SWICH TO THE "OFF" PV PANELS POSITION TO SHUT DOWN PV SYSTEM AND REDUCE Lal SHOCK HAZARD IN ARRAY SOLARQ1 WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN I _ CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT LABEL 6 AT DIRECT -CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(b)] LABEL 9 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. O O EXISTING SUB PANEL LABELING DIAGRAM: (IF WHERE POINT OF OO INTERCONNECTION IS MADE) AC DISCONNECT 0 0 o o O O O O OOR O O O O O o� (ONLY IF PV (ONLY IF PV INTERCONNECTION INTERCONNECTION CONSISTS OF LOAD CONSISTS OF LOAD SIDE BREAKER) SIDE BREAKER) PV COMBINER SUBPANEL- IF USED TO COMBINE PV OUTPUT CIRCUITS O O O MERAK ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 SITE INFORMATION Blake Richey 7806 Deer Park Ave Fort Pierce, FL 34951 AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 11.56 kW DC Lat, 27.5404594 Long,-80.4041132 (34) Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W PV MODULES (1) SolarEdge SE10000H-US (240V) INVERTER(S) FIaosE WYs.. Light ����` '4�`�%. s 7 INVERTER (S) - ■ .� . STATE OF D �C0RIDa;'��. S/0NAL�-N�'`` �r1,111fir1110110 Wyssiing Consulting, PLLC 16 N Meadowbmok Drive Alpine UT $4004 COA # RY34912 AcTIlAIS PLAID IiAS BEEN ELECTROtOCALLY SIGNED AND Z I JUNCTION BOX i WENG ALED BY SCOTT YSSL. PE USING A DIGITAL OR COMBINER BOX !3GNATURE AND DATE. PRINTED COPIES OF THIS DC UMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED O�'j' J ANY ELECTROF 17 C COPIES DOo INTEGRATED DC DISCONNECT mWel *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. DRAWN BY: SoloCAD DATE: March 15, 2022 LABELS - PV07 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: am" ""^'"' DISTRIBUTION 'DISCONNECT DISCONNECT JVERTER & RAPID HUTDOWN DC ISCONNECT SWITCH 2T%1:T:fiyil r v r%11k1Nr%1 FRONT OF HOME 7806 Deer Park Ave, Fort Pierce FL 34951 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.101) MEFRAK ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 SITE INFORMATION Blake Richey 7806 Deer Park Ave Fort Pierce, FL 34951 AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 11.56 kW DC Lat, 27.5404594 Long,-80.4041132 (34) Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W PV MODULES (1) SolarEdge SE1000OH-US (240V) INVERTER(S) FIa sE WYs.. Light 7 — .� . STATE OF Al. S�DNAIL N01`` �r�rre, r i r 1 n i t <<oi� Wyssiing Consulting, PLLC 16 N Meadowdrook Drive Alpine UT $4004 COA # RY34912 S PLAN HAS BEEN ELECTRONICALLY SIGNED AND ILED BY SCOTT WYSSLING. PE USING A DIGITAL NATURE AND DATE. PRINTED COPIES OF THIS :UMENT ARE NOT CONSIDERED SIGNED AND U-E❑ AND THE SIGNATURE MUST BE VERIFIED APIY Ft Fi' Trier iiT- r 'FPlF5 DRAWN BY: SoloCAD DATE: March 15, 2022 PLACARD - PV08 SITE PHOTOS: 0 Y-, HAZARDOUS VOLTAGE. WILL CAUSE SEVERE INJURY OR DEATH. TURN OFF POWER SUPPLYING THIS EQUIPMENT BEFORE WORIONG IA SIDE. S RVICE Di5„ONNECT MERAKI ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 SITE INFORMATION Blake Richey 7806 Deer Park Ave Fort Pierce, FL 34951 AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 11.56 kW DC Lat, 27.5404594 Long,-80.4041132 (34) Hanwha Q. Cells Q.Peak DUO BLK-G6+ 340W PV MODULES (1) SolarEdge SE10000H-US (240V) INVERTER(S) Flor'assf'"oPUuG,& Light w y5S(,, STATE OF r tORID Wyssling Consulting, PLLC 76 N Meadowlirook Drive Alpine VT $4004 CDA k RY34912 IS PLAN HAS BEEN ELECTRONICALLY SIGNED AND ALED BY SCOTT WYSSLING, PE USING A DIGITAL MATURE AND DATE. PRINTED COPIES OF THIS CUMENT ARE NOT CONSIDERED SIGNED AND ALED AND THE SIGNATURE. MUST BE VERIFIED I ANY ELECTRONIC COPIES 14 powered by DUO THE IDEAL SOLUTION FOR: 611) Rooftop arrays residential buildings U QCELLS TOP BRAND IV Quality Tested 201P9 w.vom ID. 400325832587 Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5 %. INNOVATIVE ALL-WEATHER TECHNOLOGY �, Optimal yields, whatever the weather with excellent low -light and temperature behavior. _ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID and Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.Q-rm. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). p A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY % Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. ' APT test conditions according to IEC/TS 62804-1:2015, method B (-1500V, 168h) z See data sheet on rear for further information MECHANICAL SPECIFICATION Format 68.5 x 40.6 x 1.26 in (including frame) (1740 x 1030 x 32mm) oe.c•tn4 ) ss.o•Iaeomml aesc•reeoA.a Weight 43.9lbs(19.91<g) 4se•P-) Front Cover with in ti-r mm) on technology thermally pre -stressed glass c- with anti -reflection technology 4=0 m­lre Paa.PoaTrasmml Pmm. Back Cover Compositefilm ..'(SE-) Frame Black anodized aluminum Cell 6 x 20 monocrystalline Q.ANTUM solar half cells ® 4os•poaomml Junction Box 2.09-3.98 x 1.26-2.36 x 0.59-0.71in (53-101 x 32-60 x 15-18mm), Protection class lP67,with bypassdiodes Le°°�� =waDwomml Cable 4mmzSolarcable;(+)>_45.3in(1150mm),(-)>-45.3in(1150mm) ~L-� e.Dm�n,,,l,a4. Nwmno malDEra�a - Connector Staubli MC4, Hanwha Q CELLS HQC4, Amphenol UTX, Renhe 05-6, Tongling TL-CableOlS, JMTHY JM601; IP68 or I-a.zs•Iozm„y D-A o.wo'nsmml Friends PV2e; IP67 o.Ass•Iz4.smmIT�I°"s•Issmml ELECTRICAL CHARACTERISTICS POWER CLASS 330 335 340 345 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5W/-O W) Power at MPP' PMPP [w] 330 335 340 345 Short Circuit Current' Isc [A] 10.41 10.47 10.52 10.58 E E Open Circuit Voltage' Voo IV] 40.15 40.41 40.66 40.92 5 Current at MPP I.PP [A] 9.91 9.97 10.02 10.07 Voltage at MPP VNOP [V] 33.29 33.62 33.94 34.25 Efficiency' /I [%] >-18.4 >>-18.7 >>>19.0 >>-19.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOTz Power at MPP PMPP [W] 247.0 250.7 254.5 258.2 E Short Circuit Current Is, [A] 8.39 8.43 8.48 8.52 E Open Circuit Voltage Voo IV] 37.86 38.10 38.34 38.59 c Current at MPP IaPP [A] 7.80 7.84 7.89 7.93 Voltage at MPP v- IV] 31.66 31.97 32.27 32.57 'Measurement tolerances PMPP±3%; Isc; VDc±5%at STC: 1000 W/mz, 25±2°C, AM 1.5 according to IEC 60904-3 • z800 W/mz, NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE �_ eo ssa --T - - - --r n----- i At least 98%of nominal power during _ Aw�m4b�m..mm. mP, first year Thereafter max. 0.54% c ____ ______________---_______ degradation ' 'I I per year. At least 93.1% of nominal power up to 10 years. At W a least 85%of nominal power up to > eo w > 50 25 years. so -- ----T-----r---- ----- I oAll data within measurement toleranc- es. Full warranties in accordance with zoo coo w coo t000 44 the warranty terms of the Q CELLS IRRADIANCEw/mil u >s sales organization of your respective m country. YEARS Typical module performance under low irradiance conditions in dwp14`°"c`9 comparison to STC conditions(25°C, 1000W/m2) TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of VDc 9 [%/K] -0.27 Temperature Coefficient of P_ y [%/K] -0.36 Normal Module Operating Temperature NMOT [°F] 109±5.4 (43±3°C) PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vsrs IV] 1000 (IEC)/1000 (UL) Safety Class II Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI /UL 1703 C (IEC)/TYPE 2 (UL) Max. Design Load, Push/Pulls [Ibs/ftq 75 (360OPa)/55 (2667Pa) Permitted Module Temperature-40°Fupto+185°F Max. Test Load, Push/Pull' [Ibs/ftz] 113(540OPa)/84(4000Pa) on Continuous Duty (-40°C up to+85°C) sSee Installation Manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 1703, VIDE Quality Tested, CE-compliant, IEC 61215:2016, IEC61730:2016, Number of Modules per Pallet 32 Application Class II, U.S. Patent No. 9,893,215 (solar cells) Number of Pallets per 53' Trailer 28 Number of Pallets per 40'HC-Container 24 C E DVE cCIO Us Pallet Dimensions(LxWxH) 71.5 x 45.3 x 48.Oin(1815 x 1150 x 1220mm) Pallet Weight 1505lbs (683kg) Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha 0 CELLS America Inc. Engineered in Germany OCELLS 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I TEL+1949748 59 961 EMAIL inquiryQus.q-celis.com I WEB www.q-cells.us Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE1000OH-US / SE1140OH-US O O O O is s O O � O O O O ! ! 12-25 YEAR WARRANTY Optimized installation with HD -Wave technology O / Specifically designed to work with power optimizers / UL1741 SA certified, for CPUC Rule 21 grid compliance / Record -breaking 99% weighted efficiency / Small, lightweight, and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 / Built-in module -level monitoring / Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) solaredge.com solar=@@ / Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) AC Output Voltage Min.-Nom.-Max. ✓ _ ✓ _ - ✓ Vac (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 60.50) Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.S A Current @240V Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 1 9300 1 11800 1 15500 1 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 1 400 Vdc Maximum Input Current @240V14 8.5 10.5 13.5 1 16.5 1 20 1 27 1 30.5 Adc Maximum Input Current @208V" - 9 - 13.5 1 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 500ku Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 25 Y YEAR 1 WARRANT III I li �' I Ihll�lll PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters / Up to 25% more energy / Superior efficiency (99.5%) / Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization solaredge.com 0 N m / Fast installation with a single bolt / Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdown for installer and firefighter safety solar=eez Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 INPUT Rated Input DC Power") 320 350 370 400 405 %8S 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 60 1250 83(2) Vdc MPPT Operating Range 8 - 48 8-60 8 - 80 8-60 12.5 -105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 11.02 11 10.1 11.75 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power O± 0.1 Vdc Optimizer STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant ROHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System 1000 Vdc Voltage Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 129x153x27.5/5.1x6x1.1 129x153x33.5 129x153x29.5 129x159x49.5/5.1x6.3x1.9 129x162x59 mm /5.1x6x1.3 /5.1x6x1.16 /5.1x6.4x2.3 /in Weight (including cables) 630/1.4 750/1.7 655/1.5 845/1.9 1064/2.3 gr/lb Input Connector MC4i3i Single or dual MC4i3i MC4teua) Input Wire Length 0.16 / 0.52 0.16 or 0.9 /0.52 or 2.95111 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range"' -40 to +85 / -40 to +185 `C / `F Protection Rating IP68 / NEMA6P Relative Humidity 0 -100 % (1) Rated power of the module at STC will not exceed the optimizer "Rated Input DC Power". Modules with up to +5% power tolerance areal I owed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals (5) Longer inputs wire length are available for use. For 0.9m input wire length order P401-xxxLxxx (6) For ambient temperature above +85°C / +185°F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details P320, P340, P370, Minimum String Length �,00,P401 8 10 18 (Power Optimizers) P405, P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 500i 5700 (6000 with Maximum Power per String SE7600-US - SE11400- 5250 500000) 12750(") W Parallel Strings of Different Lengths or Orientations I Yes I (7) For detailed string sizing information refer to: http://-.solaredge.com/sites/default/files/string_sizing_na.pdf (8) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (9) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (10) For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string Is T000W (11) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W C, SolarEdge Technologies Ltd. All nghts reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. CC"-,U6 RoHS All other trademarks mentioned herein are trademarks of their respective owners. Date: 08/2021 Ds-000044-1.2-NA, subject to change without notice. Intertek / Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces Revenue Grade Metering, ANSI C12.20 Consumption metering Inverter Commissioning Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 STANDARD COMPLIANCE Safety Grid Connection Standards Emissions INSTALLATION SPECIFICATIONS RS485, Ethernet, ZigBee (optional), Cellular Optionaloi With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Automatic Rapid Shutdown upon AC Grid Disconnect UL1741, UL1741 SA, UL169913, CSA C22.2, Canadian AFCI according to T.I.L. M-07 IEEE1547, Rule 21, Rule 14 (HI) FCC Part 15 Class B AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1" Maximum / 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22110 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 In / kg Noise < 25 1 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +041 `F / `C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4. For consumption metering, current transformers should be ordered separately: SEACT0750-20ONA-20 or SEACT0750-400NA-20. 20 units per box (4) Full power up to at least 50°C / 122°F; for power de -rating information refer to: https://—w.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD -wave technology and built-in RGM and Service Panel consumption monitoring Grid tTT T CT L3 N L2 Shielded CAT5e cable -- ---- --------L� --------- - ---� N L2 AC Conduit ® SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All RoH S other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020N01/ENG NAM. Subject to change without notice. /l IRONRIDGE XR Rail Family XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. K' Compatible with Flat & Pitched Roofs Force -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Corrosion -Resistant Materials XR Rails are Iron Ridge offers All XR Rails are made of 6000-series compatible with �3� a range of tilt leg aluminum alloy, then protected with an A FlashFoot and options for flat anodized finish. Anodizing prevents surface other pitched roof roof mounting and structural corrosion, while also providing attachments. applications. a more attractive appearance. *0, The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. i XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. 6'spanning capability Moderate load capability Clear & black anodized finish Internal splices available Rail Selection i XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. 10'spanning capability Heavy load capability Clear & black anodized finish Internal splices available i XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. 12'spanning capability Extreme load capability Clear anodized finish Internal splices available The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. 90 120 None 140 XR10 160 90 120 20 140 160 90 30 160 90 40 160 80 160 Rail St78'1 5' 4" XR100 XR1000 120 I 160 I I "Table is meant to be a simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance. © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 777� \ 71 S 5� The Right Way! ProteaBracket TM ProteaBracketTM is the most versatile standing seam metal roof attachment 4 solution on the market, fitting most Q trapezoidal sheet profiles with and O without intermediate insulation. It features an adjustable attachment � base and multiple solar module attachment options (illustrated on Eback) to accommodate varying widths and heights. There are no messy sealants to apply and no chance for leaks; the ProteaBracket comes with = factory -applied, adhesive rubber sealant to ensure quick installation and a weather-proof fit. = Installation is simple! The ProteaBracket is mounted directly onto the crown N of the panel, straddling the profile. C No surface preparation is necessary; E simply wipe away excess oil and debris, align, and apply. Secure ProteaBracket through its pre -punched holes, using V the hardened drill point S-5!° screws. ProteaBracket is the perfect match for our S-5-PV Kit and spares you the hassle O of cold -bridging! For a solar attachment 4-a solution that is both economical and easy to use, choose ProteaBracket.* .i *When ProteaBracket is used in conjunction with the S-5-PV Kit, an additional nut is required during installation. I- S-5!1 ProteaBracket"' is a versatile bracket that adjusts easily to most trapezoidal roof profiles. O V L6 1 U) M M Ln I N CO M1 MW MW W O ProteaBracketTM is the perfect solar attachment solution for most trapezoidal - exposed -fastened metal roof profiles! No messy sealants to apply. The S50 factory -applied adhesive rubber sealant weather -proofs and makes The Right Way! installation easy!