Loading...
HomeMy WebLinkAboutTie-Down-Engineering-2017.pdfBMP INTERNATIONAL, INC. MECHANICAL UNIT STEEL TIE —DOWN CLIP: AT GRADE &ROOF —TOP MOUNTED APPLICATIONS n N I 75LB MIN. WEIGHT, g MECHANICAL UNIT PER SEPARATE LL ( CERTIFICATION, TYP. I v r- m 0 v N °'' v J LL a v! tCENTER OF GRAVITY J � I uJ I tCENTER OF Lu U j GRAVITY NO IRREGULAR SHAPES. ( X z jf � Xw \ 0 �W { 'o 10 3" MAX TYP. HOST STRUCTURE DESIGN BY OTHERS. SEE DESIGN of '� SCHEDULES FOR 01 ij, ALLOWABLE SUBSTRATES 3" MAXX MECHANICAL UNIT TYP. 1 TIE —DOWN ISOMETRIC l 1 1" = V-0" ISOMETRIC SEE DESIGN SCHEDULE FOR MAXIMUM SURFACE AREA AND DESIGN PRESSURE, TYP. STEEL TIE -DOWN CLIPS. 1,2 SEE DETAIL 1/3 & 2/3 FOR CLIP INFORMATION, 3 TYP. uo � 01 MAX TYP. 3' TYP. y�G 5O O� TYPE OF CLIP AND NUMBER OF CLIPS PER CORNER WILL VARY PER CONNECTION TYPES Cl-C4 ON SHEET 2 TIE —DOWN CLIP DIRECTIVE EXAMPLE (THE FOLLOWING EXAMPLE ILLUSTRATES THE PROCEDURE USED TO DETERMINE THE MAXIMUM ALLOWABLE ROOF -TOP INSTALLATION HEIGHT, H, FOR ANY GIVEN MECHANICAL UNIT THAT CONFORMS TO THE DIMENSION RESTRICTIONS AND DESIGN CRITERIA LISTED HEREIN. SEE SHEETS 4-5 FOR DESIGN SCHEDULES.) MECHANICAL UNIT CRITERIA: CONSIDER THE INSTALLATION OF (1) MECHANICAL UNIT WITH THE FOLLOWING CRITERIA= • Vult=170 MPH, EXPOSURE 'B' • 48" TALL x 48" DEEP x 48" WIDE, 100 LB (WEIGHT AS VERIFIED BY OTHERS) • INSTALLED TO 3000 PSI MIN CONCRETE WITH (1)-2" CLIP AT EACH CORNER OF UNIT (TOTAL OF (4) CLIPS) PROCEDURE: PROCEDURE STEP RESULT 1 DETERMINE THE CONNECTION TYPE BASED ON THE DIAGRAMS ON SHEET 2 CONNECTION TYPE 3 2 DETERMINE WHICH DESIGN SCHEDULE TABLE TO USE THIS INSTALLATION IS INTENDED FOR A Vult=170 MPH, EXPOSURE'B'. THIS DESIGN CRITERIA CORRESPONDS TO TABLE 5 3 DETERMINE LARGEST FACE AREA OF MECHANICAL UNIT TO BE INSTALLED 48"x48"=16FT2 THIS UNIT HEIGHT OF 48" IS EQUAL TO THE MAXIMUM ALLOWABLE HEIGHT OF 48". NOTE: THIS PRODUCT APPROVAL ALLOWS THE UNIT TO BE INSTALLED ON TOP 4 CHECK MAXIMUM UNIT HEIGHT RESTRICTION OF AN A/C STAND THAT IS A MAXIMUM 30" TALL. IF AN A/C STAND IS UTILIZED, CHECK TO SEE THAT THE STAND DOES NOT EXCEED 30" IN HEIGHT 5 CHECK MINIMUM UNIT WIDTH RESTRICTION UNIT WIDTH IS 48" WHICH IS GREATER THAN THE MINIMUM ALLOWABLE WIDTH OF 24" 6 DETERMINE THE ALLOWABLE ROOF -TOP HEIGHT OF THE INSTALLATION THIS UNIT MAY BE INSTALLED AT ROOF HEIGHTS LESS THAN OR EQUAL TO 15 FT. SEE (*) ON TABLE 5 FOR THE NUMERICAL VALUES OF THIS DESIGN EXAMPLE \ # PE LiS¢,j r Ill/ +,vr` ;LL DESIGN NOTES: THIS PRODUCT HAS BEEN DESIGNED IN ACCORDANCE WITH ASCE 7-10 AND FLORIDA"''P BUILDING CODE 2017 (6TH EDITION) FOR USE WITHIN AND OUTSIDE THE HIGH VELOCI% HURRICANE ZONE AS INDICATED IN THE ACCOMPANYING DESIGN SCHEDULES. THE DESIj CRITERIA USED TO CALCULATE THE ALLOWABLE ROOF -TOP HEIGHTS CONSIDERS FBC SECTION 1609.8 FOR NON-HVHZ AND SECTION 1620.6 FOR HVHZ & ASCE 7 SECTION 29.4.1 FOR INSTALLATIONS AT GRADE. (GCf)L�,t.,ai=1.90 WITHIN THE HVHZ & OUTSIDE THE HVHZ, (GCf) ;art=1.5 FOR ALL LOCATIONS (CONCURRENT) . ALL OTHER DESIGN VARIABLES ARE IN ACCO0ANCE WITH ASCE 7-10 CHAPTERS 26 & 29. THE HEIGHTS LISTED IN THE DESIGN SCHEDULES REPRESENT THE ALLOWABLE HEIGHT OF THE BUILDING. THIS PRODUCT APPROVAL ALLOWS FOR EACH UNIT TO BE INSTALLED ON A MAXIMUM 30" TALL A/C STAND (CERTIFICATION BY OTHERS) ON TOP OF THE HEIGHTS LISTED IN THE DESIGN SCHEDULES. GENERAL NOTES: 1. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. 2. DESIGN IS BASED ON CLIENT PROVIDED PRODUCT AND DIE SHEETS FROM TEST REPORTS #TEL 01970387A, #TEL 01970387B BY TESTING EVALUATION LABORATORIES, INC.. NO SUBSTITUTIONS WITHOUT WRITTEN APPROVAL BY THIS ENGINEER SHALL BE PERMITTED. 3. MAXIMUM & MINIMUM DIMENSIONS AND MINIMUM WEIGHT OF MECHANICAL UNIT SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 4. FASTENERS TO BE #12 X 3/4" OR GREATER SAE GRADE 5 UNLESS NOTED OTHERWISE. TAPCONS REFERRED TO HEREIN SHALL BE ITW BUILDEX BRAND, CARBON STEEL ONLY, INSTALLED TO 3000 PSI MIN CONCRETE. SEE ANCHOR SCHEDULE FOR ANCHOR REQUIREMENTS. ALL FASTENERS SHALL HAVE APPROPRIATE CORROSION PROTECTION TO PREVENT ELECTROLYSIS. 5. ALL STEEL CLIPS SHALL BE ASTM A283 STEEL (GRADE D) WITH Fy=33 KSI OR BETTER. ALL STEEL MEMBERS SHALL BE PROTECTED AGAINST CORROSION WITH AN APPROVED COAT OF PAINT, ENAMEL OR OTHER APPROVED PROTECTION. G90-RATED COATING REQUIRED FOR ALL COASTAL INSTALLATIONS. 6. ALL CONCRETE SPECIFIED HEREIN IS NOT PART OF THIS CERTIFICATION. AS A MINIMUM, ALL CONCRETE SHALL BE STRUCTURAL CONCRETE 4" MIN. THICK AND SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI, UNLESS NOTED OTHERWISE. 7. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 8. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. 9. THE ADEQUACY OF ANY EXISTING STRUCTURE TO WITHSTAND SUPERIMPOSED LOADS SHALL BE VERIFIED BY THE ONSITE DESIGN PROFESSIONAL AND IS NOT INCLUDED IN THIS CERTIFICATION.EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 10. THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT FROM THE CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. 11. WATER -TIGHTNESS OF EXISTING HOST SUBSTRATE SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 12. FOR AN EXPLANATION OF EXPOSURE CATEGORIES THAT ACCOMPANY THE Vult WIND SPEEDS USED IN THIS APPROVAL, SEE SECTION 26.7.3 OF ASCE 7-10. s±m Zrx 0WU�'Z (� a 9 " Z . Coll wW o"Wzw � 3u.gW V) x oW w ID V Z F�1 H � O z tM W n owc Q m n Z = n to w W o it a z�N 1--1 cd G m 15-2378 117 0 N v U. r Z \ C7 t~ W r. J�'.. W �W= Q=Lf) W (7 Lm;U) W Vl =OLL M Lu C f `. LL H �U uw 3" MAX 1" CLIPS TYP. k TYP. 3" MAX G��O TYP. ,. '�S� N5 �� oSZG m n CONNECTION TYPE Cl 1" CLIP - UTILIZE (1) AT EACH CORNER FOR A TOTAL OF (4) PER UNIT N I � Iti S In zWin LL I a o ui J W Duo W f �0� w I� 1 CLIPS 3" MAX TYP. T 3" MAX TYP. �_c51 CONNECTION TYPE C3 2" CLIPS - UTILIZE (1) AT EACH CORNER FOR A TOTAL OF (4) PER UNIT n CONNECTION TYPE C2 Z \ zWcn =0ui �W= = In W H Z W 1 11 3" MAX TYP. ANCHOR SCHEDULE: 1 CLIPS SUBSTRATE DESCRIPTION (1)-5/16"0 CARBON STEEL ITW BUILDEX TAPCON, CONCRETE: 2Y/4" FULL EMBED TO (4" THICK MIN, CONCRETE, 31/s" MIN. 3000 PSI MIN.) EDGE DISTANCE, 33/4" MIN. SPACING TO ANY ADJACENT ANCHOR. ALUM ALUMINUM: ALUM" (1)-#14 SAE GRADE 5 MIN. MIN. SHEET METAL SCREW TO THICK, ALUMINUM, PROVIDE (5) MIN. ALUMINUM) PITCHES MIN. PAST THREAD PLANE STEEL: (1)-#14 SAE GRADE 5 (0.125" MIN. SHEET METAL SCREW TO THICK, 33 KSI STEEL, PROVIDE (5) MIN. STEEL) PITCHES MIN. PAST THREAD PLANE 1" CLIP - UTILIZE (2) AT EACH CORNER FOR A TOTAL OF (8) PER UNIT Al2" CLIPS Ili 3" MAX TYP. 1 . 3" MAX ylG��pv MAX TYP. l�ZC�G�S TYP. 5 CONNECTION TYPE C4 2" CLIPS SUBSTRATE DESCRIPTION (1)-5/16"O CARBON STEt ITW BUILDEX TAP ­CON, CONCRETE: 2Y4" FULL EMBED TO , (4" THICK MIN, CONCRETE, 3Ys" MIN. i 3000 PSI MIN.) EDGE DISTANCE, 33/4" MIN. SPACING TO ANY ADJACENT ANCHOR. ALUM ALUM" ALUMINUM: (2)-#14 SAE GRADE 5 MIN. MIN. SHEET METAL SCREWS TO THICK, 6 ALUMINUM, PROVIDE (5) MIN. ALUMINUM) PITCHES MIN. PAST THREAD PLANE STEEL: (2)-#14 SAE GRADE 5 (0.125" MIN. SHEET METAL SCREWS TO THICK, 33 KSI STEEL, PROVIDE (5) MIN. STEEL) PITCHES MIN. PAST THREAD PLANE 1. EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, IF APPLICABLE. 2. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 3. SEE DETAILS ON SHEET 3 FOR ANCHORS ATTACHING TO MECHANICAL UNIT. 2" CLIPS - UTILIZE (2) AT EACH CORNER FOR A TOTAL OF (8) PER UNIT UNIT WIDTH 6" MAX 6" MAX CLIP OFFSET CLIP PAIR SPACING CLIP OFFSET !gin FEW --I 3" TYP MECHANICAL CLIP -CLIP UNIT PER SPACING SEPARATE CERTIFICATION UTILIZE (4) CLIPS EA SIDE OF UNIT FOR A TOTAL OF (8) PER UNIT 5 ALTERNATE 8 CLIP DETAIL 3 N.T.S. PLAN VIEW THIS DETAIL MAY BE USED AS AN ALTERNATE GEOMETRIC PATTERN FOR ALL CONNECTION TYPES THAT UTILIZE (2) CLIPS AT EACH CORNER FOR A TOTAL OF (8) CLIPS PER UNIT. �-J z a H n U Z OZ M -1 w J O lu- LL. , I� J F-uj (9ul W Q�m v~i Z W" Z W o CL a U z z F-1 = a W T Val UJ 15-2378 in aD LL 02 v FRANK L. BENNARDO, # PE0046549 45 M v LL is x e U m v 0 N w N v LL i LL a 2 .2 cs N *FOR ANY CLIP LONGER THAN 10" 0.19" UTILIZE (5)-#12 SAE TYP. GRADE 5 SHEET METAL SCREWS, TYP. 0.068" THICK ASTM A283 STEEL, TYP. k o O (3)-#12 SAE GRADE 5 w o SHEET METAL SCREWS N o FOR CLIPS UP TO 5" ,� o LONG. UTILIZE (5)-#12 i SHEET METAL SCREWS FOR CLIPS LONGER — THAN 5", TYP. %a°O HOLE, WITH ANCHOR FROM 1" 0.75" CLIP ANCHOR SCHEDULE, TYP. 1" CLIP ISOMETRIC DETAIL N.T.S. 0.072" OR 0.113" THICK ASTM A283 STEEL, TYP. 0.12?IV- in N 11 0.75'. / FACTORY -MILLED %a" O HOLES; UTILIZE (1) OR (2) ANCHORS FROM 2" CLIP ANCHOR SCHEDULE, TYP. _X0 X 0 7 J (OTHER DIMENSIONS SIMILAR) Q OD (3)-#12 SAE GRADE 5 SHEET METAL SCREWS FOR CLIPS 4" LONG. UTILIZE (4)-#12 SHEET METAL SCREWS FOR CLIPS LONGER THAN 4", TYP. 1/a"0 HOLES, NOT TO BE USED FOR ANCHORS, TYP. .375" .0p„ 0.50" 0.50" 00 1• 0.50" 2 2" CLIP ISOMETRIC DETAIL 3 N.T.S. ISOMETRIC ISOMETRIC MECHANICAL UNIT BY OTHERS. ALUMINUM HOUSING UNITS SHALL BE 6063-T6 MIN. ALUMINUM SHEET WITH Fty=30 KSI, 0.125" MIN. THICKNESS, STEEL HOUSING UNITS SHALL BE ASTM A653 Fy=33KSI MIN. STEEL, GRADE 33, 22GA MIN. (t=0.0299"). 0.068" THICK ASTM— A283 STEEL CLIP, TYP. BASE OF UNIT SHALL � BE FLUSH WITH BASE OF CLIP, NO SPACE /- PERMITTED, TYP. (3)-#12 SAE GRADE 5 SHEET METAL SCREWS FOR CLIPS UP TO �5" LONG. UTILIZE (5)-#12 SHEET METAL SCREWS FOR CLIPS LONGER THAN 5". PROVIDE (5) PITCHES MIN. PAST THREAD PLANE FOR EACH SMS, TYP. ANCHOR PER ANCHOR SCHEDULE SUBSTRATE PER ANCHOR / SCHEDULE (VARIES) 1" TIE -DOWN CLIP 3 ANCHOR DETAIL 3 3" = V-0" DETAIL CLIP IS DESIGNED FOR FULL CONTACT WITH THE BASE OF EACH MECHANICAL UNIT, TYP. MECHANICAL UNIT BY OTHERS. ALUMINUM HOUSING UNITS SHALL BE 6063-T6 MIN. ALUMINUM SHEET WITH Fty=30 KSI, 0.125" MIN. THICKNESS, STEEL HOUSING UNITS SHALL BE ASTM A653 Fy=33KSI MIN. STEEL, GRADE 33, 22GA MIN. (t=0.0299"). 0.072" OR 0.113 THICK ASTM A283 STEEL CLIP, TYP BASE OF UNIT SHALL BE FLUSH WITH BASE OF CLIP, NO SPACE PERMITTED, TYP. (3)-#12 SAE GRADE 5 SHEET METAL SCREWS FOR CLIPS 4" LONG. UTILIZE (4)-#12 SHEET METAL SCREWS FOR CLIPS LONGER THAN 4". PROVIDE (5) X, PITCHES MIN. PAST THREAD PLANE FOR EACH SMS, TYP. (1) OR (2)ANCHORS / - PER ANCHOR 3/8 SCHEDULE SUBSTRATE PER i >' i % , ANCHOR SCHEDULE (VARIES) 2" TIE -DOWN CLIP 4 ANCHOR DETAIL 3 3" = 1'-0" DETAIL CLIP IS DESIGNED FOR FULL CONTACT WITH THE BASE OF EACH MECHANICAL UNIT, TYP. 1```C� ietl SF LC.: No PE004654 STATE OF //'/SS/0NN- 0+# —ko N rL Wnlin�i U1-4 J � vi V m N�M uja LL _ enft W O = U) C L °: a rn P><a:96< L.J� gQW o - w JXN z ozm z�F V'iW oz �LL.�yjZ a=w Q W W torq p V z F—� Q F � OoM J ei <L N z' = N tU v W a H G m -m�e COPYRIGHT FRANK L ENNA= PE 15-2378 J