HomeMy WebLinkAboutAPPROVED, KMV-BS-22-072 - TIARA TOWERS - ISP - ST Lucie County PermitDRAWING NAME:
CHECKED BY:
ENGINEERING FIRM:
PROJECT NUMBER:
LOCATION:
KMV-BS-22-072 - TIARA TOWERS - ISP.dwg
NO.
1
2
3
GIULIANO LEON
KMV FIBERTELECOM INC
KMV-BS-22-072
3120 N HIGHWAY A1A
FORT PIERCE, FL 34949
AERIAL FIBER - EXISTING
STRAND - EXISTING
INNERDUCT - EXISTING
UG FIBER - EXISTING
CONDUIT - EXISTING
UG FIBER - PROPOSED
AERIAL FIBER - PROPOSED
STRAND - PROPOSED
CONDUIT - PROPOSED
INNERDUCT - PROPOSED
GAS
WATER
TELEPHONE
ELECTRIC
SANITARY SEWER (SEW)
STORM DRAIN
FENCE
CABLE TV
STEAM
OIL
UNKNOWN UTILITY
LINETYPES
RIGHT OF WAY
EDGE OF PAVEMENT
SITE LOCATION
CONFIDENTIAL/PROPRIETARY SHEET: OF 01 06
JOB LOCATION
PROJECT: KMV-BS-22-072 - TIARA TOWERS - ISP
ADDRESS: 3120 N HIGHWAY A1A, FORT PIERCE , FL 34949 - ST LUCIE COUNTY PERMIT
CONTACTS
KMV Fibertelecom
FTGJOB DESCRIPTION
FOOTAGE DATA
865'DIRECTIONAL BORE
TWP :RNG :SEC :
PLAT BOOK :PAGE :
34S 40E 25
--
DATE SUBMITTED
22/02/22
BLUE STREAM
JONATHAN LARA
CONSTRUCTION MANAGER
PHONE:954-753-0100
JLARA@BLUESTREAMFIBER.COM
CYPRESS COMMUNICATIONS INC
CHRIS D. GLASS
PROJECT MANAGER
CGLASS@CYPRESSCOMMUNICATIONS.NET
772-763-9757
KMV FIBERTELECOM INC
SANDRA KARINA VARGAS
10604 NW 48TH ST
CORAL SPRINGS FL 33076
PHONE: 954-937-5239
KARINAV@KMVFIBERTELECOM.COM
Know what's below.
before you dig.Call
R
TRENCH 45'
JURISDICTION:
*ST LUCIE COUNTY
01 - COVER SHEET/SITE LOCATION
02 - OVERALL MAP
03 - 04 - PLAN VIEWS
05 - 06 - TYPICALS
SITE INDEX
HANDHOLE
PERMITTING
3
DRAWING NAME:
CHECKED BY:
ENGINEERING FIRM:
PROJECT NUMBER:
LOCATION:
KMV-BS-22-072 - TIARA TOWERS - ISP.dwg
NO.
1
2
3
GIULIANO LEON
KMV FIBERTELECOM INC
KMV-BS-22-072
3120 N HIGHWAY A1A
FORT PIERCE, FL 34949
CONFIDENTIAL/PROPRIETARY SHEET: OF 02 06
Know what's below.
before you dig.Call
RN HIGHWAY A1AST LUCIE COUNTY
PERMIT
03
KEY MAP
TIARA TOWERS CONDOS - ISP
04
DRAWING NAME:
CHECKED BY:
ENGINEERING FIRM:
PROJECT NUMBER:
LOCATION:
KMV-BS-22-072 - TIARA TOWERS - ISP.dwg
NO.
1
2
3
GIULIANO LEON
KMV FIBERTELECOM INC
KMV-BS-22-072
3120 N HIGHWAY A1A
FORT PIERCE, FL 34949N HIGHWAY / SR A1AC/L
ELECTRIC DITCH100' FD
O
T
R
O
W
50'
50'
DIRECTIONAL BORE
MAX BACK REAMER SIZE = 6''
INSTALL (2) 2'' HDPE CONDUITS
W/FIBER OPTIC CABLE
60" MINIMUM COVER
380' (Bore)
DIRECTIONAL BORE
MAX BACK REAMER SIZE = 6''
INSTALL (2) 2'' HDPE CONDUITS
W/FIBER OPTIC CABLE
60" MINIMUM COVER
DIRECTIONAL BORE
MAX BACK REAMER SIZE = 6''
INSTALL (2) 2'' HDPE CONDUIT
W/FIBER OPTIC CABLE
120" MINIMUM COVER155' (Bore)PROPOSED 1-LCP CABINET
REF: KMV-BS-22-015 - TIARA TOWERS
INSTALL 24"Wx36"Lx30"D
HANDHOLE
INSTALL 24"Wx36"Lx30"D
HANDHOLE
55' (Bore)45' (T)120' (Bore)#3120
TELEPHONE
CATV
WATER MAIN
TRAFFIC
C/L100' FD
O
T
R
O
W
50'
50'
WATER MAIN
FORCE MAIN
RECLAIMED WATER
TELEPHONE
5'24'3'CONFIDENTIAL/PROPRIETARY SHEET: OF 03 06
Know what's below.
before you dig.Call
R
SCALE: 1"=50'
PLAN VIEW
TYPICAL UNDERGROUND CONSTRUCTION:
-RESTORE ALL SURFACES TO EQUAL OR BETTER CONDITION.
-CONTRACTOR TO VERIFY ALL MEASUREMENTS AND DISTANCES PRIOR TO CONSTRUCTION.
-CONTRACTOR TO VERIFY LOCATION AND CONDITION OF EXISTING CONDUIT PRIOR TO CONSTRUCTION.
-CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND IMMEDIATELY NOTIFY THE
ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK.
-MAINTAIN MINIMUM 24" VERTICAL AND HORIZONTAL SEPARATION BETWEEN PROPOSED BY BLUE STREAM DUCTS & EXISTING UTILITIES.
-MAINTAIN A MIN BENDING RADIUS OF 5' ON ALL DUCT CONFIGURATION.
-ANY CHANGES ON PROPOSED RUNNING LINE HAVE TO GET APPROVAL FROM CCF CONSTRUCTION MANAGER.
FOR CONSTRUCTION:
-EXTREME CAUTION TO BE TAKEN TO CONTAIN SLURRY AROUND WORK AREAS
NEAR WETLANDS TO AVOID ANY WATER QUALITY ISSUES!
-LOCATIONS, ELEVATIONS LOCATIONS, ELEVATIONS AND DIMENSIONS OF
EXISTING UTILITIES, STRUCTURES AND OTHER SITE FEATURES SHOWN ON THE
DRAWINGS ARE BASED ON LIMITED INVESTIGATION TECHNIQUES AND SHOULD
BE CONSIDERED APPROXIMATE ONLY. PLEASE CONTACT SUNSHINE STATE
ONE-CALL AT 1-800-432-4770
-CAUTION: EXISTING UNDERGROUND UTILITIES IN AREA. NO ELEVATION
RECORDS FOR EXISTING UTILITIES AVAILABLE. CONTRACTOR SHOULD
CONTACT SUNSHINE 811, LOCATE ALL UTILITIES AND VERIFY ALL DEPTHS
PRIOR TO CONSTRUCTION
DRAWING NAME:
CHECKED BY:
ENGINEERING FIRM:
PROJECT NUMBER:
LOCATION:
KMV-BS-22-072 - TIARA TOWERS - ISP.dwg
NO.
1
2
3
GIULIANO LEON
KMV FIBERTELECOM INC
KMV-BS-22-072
3120 N HIGHWAY A1A
FORT PIERCE, FL 34949
BORE PIT (6'x10')145' (Bore)10' (Bore)INSTALL 24"Wx36"Lx30"D
HANDHOLE
DIRECTIONAL BORE
MAX BACK REAMER SIZE = 6''
INSTALL (1) 2'' HDPE CONDUIT
W/FIBER OPTIC CABLE
60" MINIMUM COVER
#3100
#3120
5'
CONFIDENTIAL/PROPRIETARY SHEET: OF 04 06
Know what's below.
before you dig.Call
RSCALE: 1"=50'
PLAN VIEW
TYPICAL UNDERGROUND CONSTRUCTION:
-RESTORE ALL SURFACES TO EQUAL OR BETTER CONDITION.
-CONTRACTOR TO VERIFY ALL MEASUREMENTS AND DISTANCES PRIOR TO
CONSTRUCTION.
-CONTRACTOR TO VERIFY LOCATION AND CONDITION OF EXISTING CONDUIT
PRIOR TO CONSTRUCTION.
-CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS AND
CONDITIONS ON THE JOB SITE AND IMMEDIATELY NOTIFY THE ENGINEER IN
WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK.
-MAINTAIN MINIMUM 24" VERTICAL AND HORIZONTAL SEPARATION BETWEEN
PROPOSED BY BLUE STREAM DUCTS & EXISTING UTILITIES.
-MAINTAIN A MIN BENDING RADIUS OF 5' ON ALL DUCT CONFIGURATION.
-ANY CHANGES ON PROPOSED RUNNING LINE HAVE TO GET APPROVAL FROM
CCF CONSTRUCTION MANAGER.
FOR CONSTRUCTION:
-EXTREME CAUTION TO BE TAKEN TO CONTAIN SLURRY AROUND WORK AREAS
NEAR WETLANDS TO AVOID ANY WATER QUALITY ISSUES!
-LOCATIONS, ELEVATIONS LOCATIONS, ELEVATIONS AND DIMENSIONS OF
EXISTING UTILITIES, STRUCTURES AND OTHER SITE FEATURES SHOWN ON THE
DRAWINGS ARE BASED ON LIMITED INVESTIGATION TECHNIQUES AND SHOULD
BE CONSIDERED APPROXIMATE ONLY. PLEASE CONTACT SUNSHINE STATE
ONE-CALL AT 1-800-432-4770
-CAUTION: EXISTING UNDERGROUND UTILITIES IN AREA. NO ELEVATION
RECORDS FOR EXISTING UTILITIES AVAILABLE. CONTRACTOR SHOULD
CONTACT SUNSHINE 811, LOCATE ALL UTILITIES AND VERIFY ALL DEPTHS
PRIOR TO CONSTRUCTION
DRAWING NAME:
CHECKED BY:
ENGINEERING FIRM:
PROJECT NUMBER:
LOCATION:
KMV-BS-22-072 - TIARA TOWERS - ISP.dwg
NO.
1
2
3
GIULIANO LEON
KMV FIBERTELECOM INC
KMV-BS-22-072
3120 N HIGHWAY A1A
FORT PIERCE, FL 34949
CONFIDENTIAL/PROPRIETARY SHEET: OF 05 06
TYPICAL
TIER
1
5
SKID RESISTANT
SURFACE MS-86 Ø3/8 [10] SS FLAT WASHER
2 PLACES
PG2436HA00EV2
W/ Ø1/4 [6] CENTER PIN
1/2 [13] X 4 [102] PULL SLOT
36
36
48 5/
8
2 PLACES
[6
6
0
][956]
[9
1
4
]
QUAZITE LOGO
2X Ø5/8 [16] THRU HOLE
W/ Ø1 1/4 [32] X 1/2 [13]
DEEP C'BORE (2 PLACES)
3/8-16 UNC X 4 [102] LG
S.S. HEX HEAD BOLT
2 PLACES
1/2-13 UNC
LIFTING BOLTS
4 PLACES
3/8-16 UNC SELF ALIGNING,
REPLACEABLE S.S. EZ-NUT
2 PLACES
PG2436B832
Ø4 3/4 [121] KNOCKOUT
2 EACH END
2X
5
1
/
2
[1
4
0
]
4X
4
1
/
2
[1
1
4
]
24 [610] CABLE RACK
2 PLACES
7 1/2 [191] CABLE
RACK HOOK
2 PLACES
24X36X30 BOX ASSEMBLY
W/(2) 24" CR, (2) 7 1/2" CR, HOOKS
& (4) Ø4 3/4 KNOCKOUT
PG2436Z978EV2
TYPICAL DETAIL - #
QUAZITE - 25479684
1
DRAWING NAME:
CHECKED BY:
ENGINEERING FIRM:
PROJECT NUMBER:
LOCATION:
KMV-BS-22-072 - TIARA TOWERS - ISP.dwg
NO.
1
2
3
GIULIANO LEON
KMV FIBERTELECOM INC
KMV-BS-22-072
3120 N HIGHWAY A1A
FORT PIERCE, FL 34949
CONFIDENTIAL/PROPRIETARY SHEET: OF 06 06