HomeMy WebLinkAboutAPPROVED, PV Plans Stamped - 120639_Smith, Kristina - 6005 Cassia DrivePV-1FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------THIS PROJECT COMPLIES WITH THE FOLLOWING:2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY2020 7TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)2017 NATIONAL ELECTRICAL CODE (NEC)AS ADOPTED BY ST. LUCIE COUNTYSITE LOCATIONCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:PHOTOVOLTAIC SYSTEMPV-1 SITE LOCATIONPV-2 SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BSTRUCTURAL CALCULATIONSPV-3 MOUNTING DETAILSPV-4 THREE LINE DIAGRAMPV-5 CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7 LABELSPV-7A SITE PLACARDPV-8OPTIMIZER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIX MANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2017 NECTHE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMSOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDSINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.SITE LOCATIONGREG ALBRIGHT1. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans and accompanying calculations and notify the Engineer of Record of any discrepancies prior to starting construction.2. These plans are stamped for structural code compliance of the roof framing supporting the proposed PV installation referenced only. These plans are not stamped for water leakage. PV modules, racking, and attachment components must follow manufacturer guidelines and requirements.3. Please see accompanying Structural Calculations report for details regarding calculations as well as limits of scope of work and liability.NOTE TO INSTALLERS: VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION ANDNOTIFY THE EOR AT 951.405.1733 IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING: 2x6 RAFTERS @ 24" OC SPACING WITH MAX UNSUPPORTED SPANEQUAL OR LESS THAN 12 FT. MSPINVJBUMACSITE PLANSCALE: 1/16" = 1'-0"1PV-2FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------ROOF AREA: 1697.9 SQ FTSITE PLANUTILITY METERLEGEND:OBSTRUCTIONPIPE VENT30 HANWHA QCELL:Q.PLUS BFR-G4.1- 285WCONDUITSETBACKMSP AC VISIBLELOCKABLELABELED ACDISCONNECTMSPJUNCTIONBOXINVINVERTER JB UM GREG ALBRIGHT158'-10"80'-9"158'-10"80'-9"21'-5"25'-0"57'-11"61'-2"DRIVEWAYCASSIA DRIVEROOF LINEPROPERTY LINE MSPINVJBUMACPV-2AFREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------ROOF PLANSCALE: 1/8" = 1'-0"1NOTES:1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3. JUNCTION BOX IS MOUNTED TO THE RAIL.ROOF AREA: 1697.9 SQ FTROOF PLAN WITH MODULES LAYOUTUTILITY METERLEGEND:OBSTRUCTIONPIPE VENT30 HANWHA QCELL:Q.PLUS BFR-G4.1- 285WCONDUITSETBACKMSP AC VISIBLELOCKABLELABELED ACDISCONNECTMSPJUNCTIONBOXINVINVERTER JB UM GREG ALBRIGHT2'-0"2'-0"2'-0"2'-0" 2'-0" 2'-1"2'-0"2'-0" ROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCH ARRAY PITCHAZIMUTHROOF AREA ARRAY AREA12627° 27° 269°912.34 SQ FT 467.48 SQ FT2 4 27° 27°89°362.76 SQ FT 71.92 SQ FTPV-2BFREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------ROOF DETAILS:TOTAL ROOF AREA: 1697.9 SQ FTARRAY COVERAGE: 31.77%SYSTEM DISTRIBUTED WEIGHT: 2.28 LBSSFM INFINITY \ ROCKIT MICRORAIL POINT-LOAD: 12.3 LBSROOF DETAILSGREG ALBRIGHT ROOF DECK /MEMBRANESLIDER AND TRIMRAILROOF ATTACHMENTBUILDING STRUCTURE5/16" STAINLESS STEEL LAGBOLT OR STRUCTURAL SCREWWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHER2.5"TRIMRAIL2.5" MIN. EMBED.FLASHINGROOF / DECK MEMBRANESLIDERSBUILDING STRUCTURE5/16" STAINLESS STEELLAG BOLT ORSTRUCTURAL SCREWWITH 2-1/2" MIN.EMBEDMENT AND FLATWASHER2.5"MICRORAILFLASHING2.5" MIN. EMBED.HANWHA QCELL: Q.PLUSBFR-G4.1- 285WHANWHA QCELL: Q.PLUSBFR-G4.1- 285WSLIDERSMICRORAIL2.5" MIN. EMBED.5/16" STAINLESS STEEL LAGBOLT OR STRUCTURAL SCREWWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHERTRIMRAIL2.5" MIN. EMBED.FLASHINGFLASHINGSLIDER AND TRIMRAIL ROOFATTACHMENT2X6 RAFTER @ 24" O.C.ROOF / DECK MEMBRANE3" MIN. 6" MAX.HANWHA QCELL: Q.PLUSBFR-G4.1- 285WATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPARTIAL ROOF FRAMING PLANScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------MOUNTING DETAILSGREG ALBRIGHTMAX ATTACHMENT SPAN - 4' SOLAREDGE P401 POWER OPTIMIZERSJUNCTIONBOXSTRING-12 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#8 AWG MUST BE IN EMT CONDUITSTRING-2SOLAREDGE P401POWER OPTIMIZERS2 - #10 AWG,PV WIRE15 HANWHA QCELL: Q.PLUSBFR-G4.1- 285W15 HANWHA QCELL: Q.PLUSBFR-G4.1- 285W4 - #10 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUITUM(E) 150A / 2P MAINBREAKER(END FED)(E) 200A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITYMETER(N) 35A / 2P PV BREAKERTO OTHER LOADSTO UTILITYOVERHEADFEED3 - #8 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) 60A RATEDAC DISCONNECTEATON DG222URB (OREQUIVALENT) KNIFEBLADE, LOCKABLE,NEMA 3R, UL LISTED3 - #8 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) SOLAREDGESE6000H-USRGM [SI1]INVERTERACDCRAPIDSHUTDOWNSWITCHNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED BREAKER SIZINGMAX. CONTINUOUS OUTPUT 25.00A @ 240V25.00X1.25= 31.25AMPS 35A BREAKER - OKSEE 705.12 OF 2017 NEC200X1.20=240240-150= 90A ALLOWABLE BACKFEEDPV-4FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------THREE LINE DIAGRAMGREG ALBRIGHT PV-5FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------CONDUCTOR CALCULATIONSGREG ALBRIGHTWIRE SCHEDULERACEWAY#EQUIPMENTWIRE LOCATIONCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)STARTINGCURRENTAPPLIED TOCONDUCTORSIN RACEWAYTEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY1DC MODULE TO OPTIMIZER ROOF / FREE-AIR210 4011.831 1 40.00 14.782DC OPTIMIZER TO JUNCTION BOX ROOF / FREE-AIR2 10 40 15.00 1 1 40.00 18.753DCJUNCTION BOX TOINVERTEREXTERIOR WALL4 10 40 15.00 1 0.8 32.00 18.754ACINVERTERTO AC DISCONNECT EXTERIOR WALL3 8 55 25.00 1 1 55.00 31.255AC AC DISCONNECT TO POI EXTERIOR WALL385525.00 1 1 55.00 31.25CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------QTY.PART PART # DESCRIPTION30 MODULES 111-285HANWHA QCELL: Q.PLUS BFR-G4.1- 285W30OPTIMIZERS130-401SOLAREDGE P401 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON1 JUNCTION BOX480-276600VDC NEMA 3R UL LISTED JUNCTION BOX2 CONNECTORS 240-300STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)2 CONNECTORS240-301STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)1 INVERTER120-603SOLAREDGE SE6000H-USRGM [SI1] 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN1 AC DISCONNECT 321-060 60A RATED 240VAC NEMA 3R UL LISTED100ROOF ATTACHMENT 1261 -602SFM INFINITY \ ROCKIT MICRORAIL22 SFM TRIM 1241-253FLASHKIT SFM / ROCK-IT TRIM COMP DARK56 SFM SLIDER 1 261-603 FLASHKIT SFM / ROCK-IT SLIDER COMP DARK17 BONDING CLAMP 1221-100N/S BONDING CLAMP7 BONDING CLAMP 1241-404TRIM BONDING CLAMP32 MOUNT ASSEMBLY 1 241-405 MLPE MOUNT ASSY18 SFM SPLICE 1 261-604 SFM / ROCK-IT SPLICE4 SFM ATTACHED SPLICE 1211-101ATTACHED SPLICE 8 INCH25TRIMRAIL 1261-606 TRIMRAIL UNIV CLIP W/ HDW8 TRIM SPLICE 1 261-605 TRIM SPLICE DRK13TRIMRAIL 1211-115 TRIMRAIL UNIV DRK30 GROUND LUG 1 260-585 ILSCO GROUND LUG30 TRIM END CAPS 1 221-200 UNIRAC SFM / ROCK-IT TRIM END CAPSBREAKER SIZES:35A PV BREAKERSERVICE LIST:NONEEQUIPMENT & SERVICE LISTGREG ALBRIGHT NOTES:M690.54705.12(B)(2)(3)(b)"WARNING"DUAL POWER SOURCESSECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 25.00 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSWARNING:POWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE.TURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAY690.56(C)(1)(A)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC 690.15, 690.54PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 25.00 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)INVERTERARRAYJ/BDC"WARNING"ELECTRICAL SHOCK HAZARD.TERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITION690.13 (B)690.53NEC 690.31(G)(3) & (4)PMPV METERSOLAR ELECTRICPV PANELSPV SYSTEM DC DISCONNECTMAXIMUM VOLTAGE: 480VMAXIMUM CIRCUIT CURRENT: 16.5AMAX RATED OUTPUT CURRENT OFTHE CONTROLLER OR DC-TO-DCCONVERTER: 15ATURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNENTIRE PV SYSTEMNFPA 11.12.2.1.1.1.1SOLAR ELECTRICPV PANELSEMERGENCY RESPONDERTHIS SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION.ONLY CONDUCTORS INSIDEBUILDING OR OFF THEROOF WILL SHUT DOWNNFPA 11.12.2.1.1.1.2SOLAR ELECTRICPV PANELSEMERGENCY RESPONDERTHIS SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWN"WARNING"PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESPV-7FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------LABELSGREG ALBRIGHT1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2. ALL MARKING SHALL CONSIST OF THE FOLLOWING:A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B. RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C. ARIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWS MSPINVJBUMACCAUTION:PV-7AFREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2. ALL MARKING SHALL CONSIST OF THE FOLLOWING:A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C. AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDGREG ALBRIGHTWARNINGTURN OFF PHOTOVOLTAIC AC DISCONNECTPRIOR TO WORKING INSIDE PANELNCASSIA DRIVEPOWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWNJUNCTION BOX30 PV MODULESAC DISCONNECTUTILITY METERINVERTER EQUIPPEDWITH RAPID SHUTDOWNMAIN SERVICE PANEL 123456789101-10 11-20 21-30 31-40 41-50 51-60123456789101-10 11-20 21-30 31-40 41-50 51-60PV-8FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------SOLAREDGE OPTIMIZER CHARTOPTIMIZER CHARTGREG ALBRIGHT SAFETY PLANMARK UP KEYINSTRUCTIONS:1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2. SAFETY PLAN MUST BE MARKED BEFORE JOBSTARTS AS PART OF THE PRE-PLAN3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE& MAKE NOTES ON THE JHA SHEETIN CASE OF EMERGENCYNEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINICNAME: _______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATIONNAME: _______________________________________________PHONE NUMBER: _____________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THESAFETY PLAN AND SIGN INDICATING THAT THEY AREAWARE OF THE HAZARDS ON-SITE AND THE PLAN FORWORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OPV-9FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------SAFETY PLANGREG ALBRIGHT JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder AccessxLadders must be inspected before each use.xExtension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.xExtension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.xA-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).xAdditional notes:Mobile EquipmentxOnly Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.xType(s) of mobile equipment (Type/Make/Model):xQualified operator(s):Material Handling and StoragexMaterials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall ProtectionxA site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.xFirst-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.xFPCP (name and title):xFPU and LPD (name and title):Electrical SafetyxThe Electrical Qualified Person (EQP) is required onsite toperform electrical work.xAll electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.xService drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.xEQP (name and tile):Public ProtectionxThe safety of the Client and Public must be maintained at alltimes.xThe Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.xCompany, Client and Public property shall be protected fromfalling objects.xPets (including dogs) shall be secured by their owners prior towork start.xThe Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.xCrew leader responsible for communication with the client:xClient and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety BriefingxAll employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.xCrew leader (name/title):xCrew member (name/title):xCrew member (name/title):xCrew member (name/title):xCrew member (name/title):xCrew member (name/title):Airborne Contaminants:xAsbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)xAsbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.xIf yes, list specific tasks and protection in place:Weather and EnvironmentxThe site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)xThe site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.xElevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.xForecasted weather maximum temp (degrees f):Heat Related Illness PreventionxEmployees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.xShade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.xNew employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.xEmployees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.xCool Vests are encouraged for all employees at all times duringperiods of high heat.xIdentify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?xIf offsite replenish is necessary, where will you go to replenishwater (location/address):xWho will replenish the drinking water (name):Restroom facilitiesxEmployees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.xRestroom facilities will be (circle one): Onsite - OffsitexIf Offsite, add location name and address:Incident Reporting ProcedurexContact your Site SupervisorName:Phone:xContact your ManagerName:Phone:xContact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BY DATENO.SHEET:REVISIONSJOB NO:F120639DESIGNED BY:C.CLIENT:KRISTINA SMITH6005 CASSIA DRIVE, FORT PIERCE, FL34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (772) 332-0281SYSTEM:SYSTEM SIZE (DC): 30 X 285 = 8.550 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 30 X HANWHA QCELL: Q.PLUSBFR-G4.1- 285WOPTIMIZERS: 30 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:3/11/2022---------SAFETY PLANGREG ALBRIGHT Q.PLUS BFR-G4.1 280-2901 APT test conditions: Cells at -1500 V against grounded, with conductive me-tal foil covered module surface, 25 °C, 168 h2 See data sheet on rear for further information.Q.ANTUM SOLAR MODULEThe new high-performance module Q.PLUS BFR-G4.1 is the ideal solution for all applications thanks to its innovative cell technology Q.ANTUM. The world-record cell design was developed to achieve the best performance under real conditions – even with low radiation intensity and on clear, hot summer days. LOW ELECTRICITY GENERATION COSTS Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 17.7 %.INNOVATIVE ALL-WEATHER TECHNOLOGYOptimal yields, whatever the weather with excellent low-light and temperature behavior.ENDURING HIGH PERFORMANCELong-term yield security with Anti-PID Technology1,Hot-Spot-Protect and Traceable Quality Tra.Q™.EXTREME WEATHER RATINGHigh-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC.MAXIMUM COST REDUCTIONSUp to 10 % lower logistics costs due to higher module capacity per box.A RELIABLE INVESTMENTInclusive 12-year product warranty and 25-year linear performance guarantee2. THE IDEAL SOLUTION FOR:Rooftop arrays on commercial / industrial buildingsRooftop arrays onresidential buildingsANTI PID TECHNOLOGY(APT)HOT-SPOT PROTECT(HSP)TRACEABLE QUALITY(TRA.Q™)YIELD SECURITY174 modules testedBest polycrystallinesolar module 2014Q.PRO-G2 235 MOD:27898photon.info/laboratory999Quality TestedID. 40032587high reliabilitylow degradationfrequentproduct surveillanceUL 1703; VDE Quality Tested; CE-compliant; IEC 61215 (Ed.2); IEC 61730 (Ed.1) application class ASpecifications subject to technical changes © Hanwha Q CELLS Q.PLUS BFR-G4.1_280-290_2016-08_Rev01_NAAt least 97 % of nominal power during first year. Thereafter max. 0.6 % degradation per year.At least 92 % of nominal power up to 10 years.At least 83 % of nominal power up to 25 years.All data within measurement tolerances.Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country.Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2).Hanwha Q CELLS America Inc.300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.usMECHANICAL SPECIFICATIONQ CELLS PERFORMANCE WARRANTYPERFORMANCE AT LOW IRRADIANCEIRRADIANCE [W/m²]RELATIVE EFFICIENCY [%] 200 400 600 800 10001101009080Format65.7 in × 39.4 in × 1.26 in (including frame)(1670 mm × 1000 mm × 32 mm)Weight41.45 lbs (18.8 kg)Front Cover0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technologyBack CoverComposite filmFrameBlack anodized aluminumCell6 × 10 Q.ANTUM solar cellsJunction box3.54-4.33 in × 2.99-3.03 in × 0.59-0.75 in (90-110 × 76-77 × 15-19 mm),Protection class IP67, with bypass diodesCable4 mm² Solar cable; (+) ≥ 39.37 in (1000 mm), (-) ≥ 39.37 in (1000 mm)ConnectorMC4, IP68PROPERTIES FOR SYSTEM DESIGNMaximum System Voltage VSYS[V]1000 (IEC) / 1000 (UL)Safety ClassIIMaximum Series Fuse Rating[A DC]20Fire RatingC (IEC) / TYPE 1 (UL)Design load, push (UL)2[lbs/ft2]75 (3600 Pa)Permitted module temperatureon continuous duty− 40 °F up to +185 °F(− 40 °C up to +85 °C)Design load, pull (UL)2[lbs/ft2]55.6 (2666 Pa)2 see installation manualQUALIFICATIONS AND CERTIFICATESPACKAGING INFORMATIONNumber of Modules per Pallet32Number of Pallets per 53' Container30Number of Pallets per 40' Container26Pallet Dimensions ( L × W × H )68.7 in × 45.3 in × 46.1 in(1745 × 1150 × 1170 mm)Pallet Weight1435 lbs (651 kg)NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]10095908580751552520010YEARS97Q CELLSIndustry standard for tiered warranties*Industry standard for linear warranties**Standard terms of guarantee for the 10 PV companieswith the highest production capacity in 2014 (as at: September 2014)DETAIL A0.630" (16 mm)0.335" (8.5 mm)0.965" (24.5 mm)Junction bo×Product label38.58" (980 mm)65.7" (1670 mm) 4 × Fastening points (DETAIL A)Cable withconnectorsFrame5.90" (150 mm)39.4" (1000 mm)37.44" (951 mm)1.26" (32 mm)8 × Drainage holes6 × Grounding points ø 0.177" (4.5 mm)39.37" (1000 mm)13.6“ (345 mm)ELECTRICAL CHARACTERISTICSPOWER CLASS280 285 290MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / -0 W)MinimumPower at MPP2PMPP[W]280 285 290Short Circuit Current*ISC[A]9.41 9.46 9.52Open Circuit Voltage*VOC[V]38.97 39.22 39.48Current at MPP*IMPP[A]8.84 8.91 8.98Voltage at MPP*VMPP[V]31.67 31.99 32.29Efficiency2Ș[%]≥ 16.8≥ 17.1 ≥ 17.4MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC3MinimumPower at MPP2PMPP[W]207.0 210.7 214.4Short Circuit Current*ISC[A]7.58 7.63 7.68Open Circuit Voltage*VOC[V]36.37 36.61 36.84Current at MPP*IMPP[A]6.93 6.99 7.05Voltage at MPP*VMPP[V]29.87 30.15 30.4211000 W/m², 25 °C, spectrum AM 1.5 G 2 Measurement tolerances STC ± 3 %; NOC ± 5 % 3 800 W/m², NOCT, spectrum AM 1.5 G * typical values, actual values may differCertifiedUL 1703(254141)TEMPERATURE COEFFICIENTSTemperature Coefficient of ISCĮ[% / K]+ 0.04Temperature Coefficient of VOCȕ[% / K]− 0.29Temperature Coefficient of PMPPȖ[% / K]− 0.40Normal Operating Cell TemperatureNOCT [°F]113 ± 5.4 (45 ± 3 °C) Power OptimizerFor North AmericaP370 / P400 / P401 / P485 / P50525YEARWARRANTYPV power optimization at the module-levelSpecifically designed to work with SolarEdgeinvertersUp to 25% more energySuperior efficiency (99.5%)Mitigates all types of module mismatch losses,from manufacturing tolerance to partialshadingFlexible system design for maximum spaceutilizationFast installation with a single boltNext generation maintenance with module-level monitoringMeets NEC requirements for arc faultprotection (AFCI) and Photovoltaic RapidShutdown System (PVRSS)Module-level voltage shutdown for installerand firefighter safetysolaredge.comPOWER OPTIMIZERPower OptimizerFor North AmericaP370 / P400 / P401 / P485 / P505Optimizermodel(typicalmodulecompatibility)P370(for higher-power 60and 72-cell modules)P400(for 72&96-cell modules)P401(for high power 60and72 cell modules)P485(for high-voltagemodules)P505(for highercurrent modules)INPUTRated Input DC Power(1)370400430485505WAbsolute Maximum Input Voltage(Voc at lowest temperature)60 80 60125(2)83(2)VdcMPPT Operating Range8-608-808-6012.5 - 10512.5 - 83VdcMaximum Short Circuit Current (Isc)1110.112.51114AdcMaximum DC Input Current13.7512.514.6512.517.5Maximum Efficiency99.5%Weighted Efficiency98.8%Overvoltage CategoryIIOUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)Maximum Output Current15AdcMaximum OutputVoltage6080VdcOUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)SafetyOutput Voltage per Power Optimizer1±0.1VdcSTANDARD COMPLIANCEEMCFCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3SafetyIEC62109-1 (class II safety), UL1741, NEC/PVRSSMaterialUL94 V-0 , UV ResistantRoHSYesINSTALLATION SPECIFICATIONSMaximum Allowed System Voltage1000VdcCompatible invertersAll SolarEdge Single Phase and Three Phase invertersDimensions(W x L x H)129 x 153 x 27.5 /5.1 x 6 x 1.1129 x 153 x 33.5 /5.1 x 6 x 1.3129 x 153 x 29.5 /5.1x6x1.16129 x 159 x 49.5 /5.1 x 6.3 x 1.9129 x 162 x 59 /5.1 x 6.4 x 2.3mm/inWeight (including cables)630 / 1.4750 / 1.7655 / 1.5845 / 1.91064 / 2.3gr / lbInputConnectorMC4(3)MC4(3)MC4(3)Input Wire Length0.16 / 0.5m/ftOutput Wire Type / ConnectorDouble Insulated / MC4Output Wire Length1.2 / 3.9m/ftOperating Temperature Range(4)-40 to +85 / -40 to +185ÜC/ÜFProtection RatingIP68 / Type6BRelative Humidity0-100%(1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed(2) NEC 2017 requires max input voltage be not more than 80V(3) For other connector types please contact SolarEdge(4)Longer inputs wire lengths are available for use. For 0.9m input wire length order P401-xxxLxxx(5)For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdfPVSystem Design Using a SolarEdgeInverter(6)(7)Single PhaseHD-WaveSinglephaseThree Phase for208V gridThree Phase for277/480V gridMinimum String Length(Power Optimizers)P370, P400, P40181018P485, P5056814Maximum String Length (Power Optimizers)252550MaximumPower per String5700(8)(6000 withSE7600-US - SE11400-US)5250(8)6000(9)12750(10)WParallelStrings of Different Lengths or OrientationsYes(6)For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf(7)It is not allowed to mix P485/P505 with P370/P400/P401 in one string(8)A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement(9)For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W(10)For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc.All other trademarks mentioned herein are trademarks of their respective owners. Date: February 10, 2022DS-000044-NA. Subject to change withoutnotice. INVERTERS solaredge.comOptimized installation with HD-Wave technology6SHFLÀFDOO\GHVLJQHGWRZRUNZLWKSRZHURSWLPL]HUV%XLOWLQPRGXOHOHYHOPRQLWRULQJ2XWGRRUDQGLQGRRULQVWDOODWLRQ2SWLRQDO5HYHQXHJUDGHGDWD$16,&&ODVV DFFXUDF\ 5HFRUGEUHDNLQJH඼FLHQF\)L[HGYROWDJHLQYHUWHUIRUORQJHUVWULQJV,QWHJUDWHGDUFIDXOWSURWHFWLRQDQGUDSLGVKXWGRZQIRU1(&DQGSHUDUWLFOHDQG([WUHPHO\VPDOO8/6$FHUWLÀHGIRU&38&5XOHJULGFRPSOLDQFHSingle Phase Inverter with HD-Wave Technologyfor North America6(+866(+866(+866(+866(+866(+866(+8612-25YEARWARRANTYSE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-USOUTPUT Rated AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V7600 1000011400 @ 240V10000 @ 208VVAMaximum AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V7600 1000011400 @ 240V10000 @ 208VVAAC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)9999999VacAC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-9-9--9VacAC Frequency (Nominal)59.3 - 60 - 60.5(1)HzMaximum Continuous Output Current @240V12.5 16 21 25 32 42 47.5 AMaximum Continuous Output Current @208V-16-24- -48.5AGFDI Threshold1AUtility Monitoring, Islanding Protection, &RXQWU\&RQÀJXUDEOH7KUHVKROGVYesINPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 WMaximum DC Power @208V - 5100 - 7750 - - 15500 WTransformer-less, Ungrounded YesMaximum Input Voltage480 VdcNominal DC Input Voltage 380 400 VdcMaximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 AdcMaximum Input Current @208V(2)-9-13.5--27AdcMax. Input Short Circuit Current45 AdcReverse-Polarity ProtectionYesGround-Fault Isolation Detection 600k Sensitivity0D[LPXP,QYHUWHU(੕FLHQF\99 99.2 %&(&:HLJKWHG(੕FLHQF\9999 @ 240V98.5 @ 208V%Nighttime Power Consumption< 2.5 WADDITIONAL FEATURESSupported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20 Optional(3)Rapid Shutdown - NEC 2014 and 2017 690.12Automatic Rapid Shutdown upon AC Grid DisconnectSTANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI)EmissionsFCC Part 15 Class BINSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWGDC Input Conduit Size / # of Strings / AWG Range0D[LPXPᐎULQJV$:* 0D[LPXPᐎULQJV$:*Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185in / mmWeight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6OENJNoise < 25 <50 dBACoolingNatural ConvectionOperating Temperature Range -13 to +140 / -25 to +60(4) Ü)Ü&RSWLRQ (5)Ü)Ü&Protection Rating NEMA 4X (Inverter with Safety Switch)(1) For other regional settings please contact SolarEdge support (2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG (3) Revenue grade inverter P/N: SExxxxH-US000NNC2(4) For power de-rating information refer to: KWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI(5) -40 version P/N: SExxxxH-US000NNU4 SE3000H-USSE3800H-USSE5000H-USSE6000H-USSE7600H-USSE10000H-USSE11400H-USOUTPUTRated AC Power Output30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V76001000011400 @ 240V10000 @ 208VVAMaximum AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V76001000011400 @ 240V10000 @ 208VVAAC Output Voltage Min.-Nom.-Max.(211 - 240 - 264)9999999VacAC Output Voltage Min.-Nom.-Max.(183 - 208 - 229)-9-9--9VacAC Frequency (Nominal)59.3 - 60 - 60.5(1)HzMaximum Continuous Output Current @240V12.5162125324247.5AMaximum Continuous Output Current @208V-16-24--48.5AGFDI Threshold1AUtility Monitoring, Islanding Protection,&RXQWU\&RQÀJXUDEOH7KUHVKROGVYesINPUTMaximum DC Power @240V4650590077509300118001550017650WMaximum DC Power @208V-5100-7750--15500WTransformer-less, Ungrounded YesMaximum Input Voltage480VdcNominal DC Input Voltage380400VdcMaximum Input Current @240V(2)8.510.513.516.5202730.5AdcMaximum Input Current @208V(2)-9-13.5--27AdcMax. Input Short Circuit Current45AdcReverse-Polarity ProtectionYesGround-Fault Isolation Detection600k Sensitivity0D[LPXP,QYHUWHU(੕FLHQF\9999.2%&(&:HLJKWHG(੕FLHQF\9999 @ 240V98.5 @ 208V%Nighttime Power Consumption< 2.5WADDITIONAL FEATURESSupported Communication InterfacesRS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20Optional(3)Rapid Shutdown - NEC 2014 and2017 690.12Automatic Rapid Shutdown upon AC Grid DisconnectSTANDARD COMPLIANCESafetyUL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07Grid Connection StandardsIEEE1547, Rule 21, Rule 14 (HI)EmissionsFCC Part 15 Class BINSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range1" Maximum / 14-6 AWG1" Maximum /14-4 AWGDC Input Conduit Size / # of Strings / AWG Range0D[LPXPᐎULQJV$:*0D[LPXPᐎULQJV$:*Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 17421.3 x 14.6 x 7.3 / 540 x 370 x 185in / mmWeight with Safety Switch22 / 1025.1 / 11.426.2 / 11.938.8 / 17.6OENJNoise < 25<50dBACoolingNatural ConvectionOperating Temperature Range -13 to +140 / -25 to +60(4) Ü)Ü&RSWLRQ (5)Ü)Ü&Protection Rating NEMA 4X (Inverter with Safety Switch)(1) For other regional settings please contact SolarEdge support(2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG(3) Revenue grade inverter P/N: SExxxxH-US000NNC2(4) For power de-rating information refer to:KWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI(5) -40 version P/N: SExxxxH-US000NNU4Single Phase Inverterwith HD-Wave Technology for North America6(+866(+866(+866(+866(+866(+866(+86Œ6RODU(GJH7HFKQRORJLHV,QF$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF$OORWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH9(1*1$06XEMHFWWRFKDQJHZLWKRXWQRWLFH pe.eaton.com Eaton general duty non-fusiblesafety switchDG222URBUPC:782113144238Dimensions:Height:14.38 IN●Length:7.38 IN●Width:8.69 IN●Weight:9 LBNotes:WARNING! Switch is not approved forservice entrance unless a neutral kit is installed.Warranties: Eaton Selling Policy 25-000, one (1) year fromthe date of installation of the Product oreighteen (18) months from the date of shipmentof the Product, whichever occurs first.●Specifications:Type:Non-fusible, single-throw●Amperage Rating:60A●Enclosure:NEMA 3R, Rainproof●Enclosure Material:Painted galvanized steel●Fuse Configuration:Non-fusible●Number Of Poles:Two-pole●Number Of Wires:Two-wire●Product Category:General duty safety switch●Voltage Rating:240V●Supporting documents:Eatons Volume 2-Commercial Distribution●Eaton Specification Sheet - DG222URB●Certifications: UL Listed●Product compliance:No Data______________________________________________________________________© 2016 Eaton. All rights reserved. The RockIt system is the industry’s premier rail-less PV racking system for composition shingle, tile, and metal roofs. Designed in conjunction with the needs of installers, RockIt quickly & easily installs with a single tool. Featuring an easy-to-position alignment slide and a top-down leveling system, RockIt is logistically intelligent with no need to ship or transport long rails. Components are DYDLODEOHLQDEODFNȴQLVKWKDWFRPSOHPHQWVERWKFRPPHUFLDOand residential applications. Conforms to UL 2703. FEATURES & BENEFITS• Patented watertight technology • Fully integrated bonding• Top-down leveling system•North-South adjustability• Single tool installCOMPLETE RAIL-LESS RACKING SYSTEMSTREAMLINED INSTALLATION WITH MINIMAL ROOF PENETRATIONSComposition Shingle, Tile, MetalRail-LessStructural-Attach Direct-AttachECOFASTENSOLAR.COMFRAME MLPE MOUNT Attaches and fully bonds MLPE’s (Module Level Power Electronics) to the module frame with a single bolt clip.COUPLING The fast installing RockIt Coupling easily attaches to the module frame to bridge the gaps between modules. ROCKIT SLIDEAvailable in three variations, the RockIt Slide allows installation on composition shingle, tile, and metal roofs.SKIRTThe sleek black Skirt installs first and acts as an alignment guide for the entire array. The Skirt End Cap does double duty as a skirt coupling device and an aesthetically-pleasing finishing touch.ROCKIT MOUNTFeaturing integrated bonding pins, the RockIt Mount connects to the Slide and can easily be positioned for fast installation. Features top-down leveling. Take your business to the next level with SFM INFINITY, UNIRAC’s rail-less PV mounting system for flush mount installations on comp shingle and tile roofs. An advanced 3rd generation product platform in use by top solar contractors nationwide, SFM INFINITY optimizes your operations on and off the roof, with approximately 40% less labor, 30% logistics savings, and 20% fewer roof attachments than traditional solar racking. Plus, 87% of homeowners prefer SFM INFINITY’s aesthetics.SUPERIOR PERFORMANCEEnhance your business with two installs per dayand 30% less cost.EASY INSTALLATIONPre-assembled components, 20% fewer roof attachments, and level array in seconds with post height adjustment. HOMEOWNER PREFERREDMore than 4 out of 5 homeowners prefer SFM INFINITY’S aesthetics over a leading rail brand.SFM INFINITYFRONT TRIM AND END CAPSUNIVERSAL COMPONENTSFIT 32 – 40MM MODULESEOWNERPREFERRED25 YEAR FULL-SYSTEM WARRANTYONE SKU FITS 32 TO 40mmREVOLUTIONIZING ROOFTOP SOLARFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702REVOLUTIONIZING ROOFTOP SOLARFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702SFM INFINITYDESIGN GUIDELINESAPPLICATION GUIDEWhile you will see advantages simply from switching to SFM INFINITY, the following guidelines will help you to maximize its benefits.When possible, design in landscape orientation in order to fit more modules on the roof and minimize roof attachments.DEFAULT TO LANDSCAPESFM INFINITY is easily configured in mixed array shapes and module orientations to maximize array density and to avoid vent pipes and other obstacles. Because mounting locations are not constrained by rails, SFM INFINITY has unmatched flexibility to enhance your projects.MIX MODULE ORIENTATIONSVisit UNIRAC’s mobile-friendly library of short, topic-specific videos which answer common questions and demonstrate how simple it is to install SFM INFINITY.CONSULT THE QUICK TIPS VIDEOSQuick Tips Videos: https://unirac.com/SFM-Infinity/ Layout your arrays in U-Builder, UNIRAC’s free solar design software, to optimize SFM INFINITY’S capabilities, including mixing module orientations and minimizing roof attachments. Quickly create layouts on Google or Bing Maps and generate project documents.DESIGN IN U-BUILDERU-Builder: https://design.unirac.com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ϸ8/'HVLJQ/RDG5DWLQJ36)'RZQZDUG36)8SZDUG36)'RZQ6ORSH7HVWHG/RDGVSVI3D'RZQZDUGSVI3D8SOLIWSVI3D'RZQ6ORSH7ULQD7603'DQG6XQSRZHU635(XVHGIRU0HFKDQLFDO/RDGLQJ,QFUHDVHGVL]H0/WHVW0D[LPXP0RGXOH6L]HIWð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´JDSEHWZHHQWKHERWWRPRIWKHPRGXOHDQGWKHURRI¶VVXUIDFHSee section 7.0 illustraction # 1 and 1a for a complete list of PV modules evaluated with these racking systems5DWLQJV1$(' $SU 0DQGDWRU\ AUTHORIZATION TO MARKApplicant: Manufacturer:Address: Address:Country: Country:Contact: Contact:Phone: Phone:FAX: FAX:Email: Email:Standard(s):Product:Brand Name:Models:This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.Intertek Testing Services NA Inc.545 East Algonquin Road, Arlington Heights, IL 60005Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1]Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20Unirac SFMUniracControl Number:5003705Authorized by: for Dean Davidson, Certification ManagerThis document supersedes all previous Authorizations to Mark for the noted Report Number.klaus.nicolaedis@unirac.comtoddg@unirac.comjia.liu@cxymj.combuwan.luo@cxymj.comParty Authorized To Apply Mark:Same as ManufacturerReport Issuing Office:Lake Forest, CA U.S.A.Klaus NicolaedisTom YoungJia LiuRobin Luo505-462-2190 505-843-1418+86-15267030962+86-13621785753NA NAUnirac, Inc Cixi Emeka Aluminum Co. Ltd1411 Broadway Blvd NEAlbuquerque, NM 87102No. 688 ChaoSheng RoadCixi CityZhejiang Province 315311USA ChinaThis authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)Covered section when made in accordance with the conditions set forth in the Certification Agreement and ListingReport. This authorization also applies to multiple listee model(s) identified on the correlation page of the ListingReport.This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may beapplied only at the location of the Party Authorized To Apply Mark.Page 1 of 1 ATM for Report 102393982LAX-002 ATM Issued: 9-Apr-2019ED 16.3.15 (20-Apr-17) Mandatory ĐŽ&ĂƐƚĞŶ^ŽůĂƌ>>ϰϭϰϭtsĂŶƵƌĞŶ^ƚ͕^ƚĞϮWŚŽĞŶŝdž͕ϴϱϬϬϵd>͗;ϴϳϳͿϴϱϵͲϯϵϰϳƚƚŶ͗͘ĐŽ&ĂƐƚĞŶ^ŽůĂƌ>>ͲŶŐŝŶĞĞƌŝŶŐĞƉĂƌƚŵĞŶƚ^ƵďũĞĐƚ͗ŶŐŝŶĞĞƌŝŶŐĞƌƚŝĨŝĐĂƚŝŽŶĨŽƌƚŚĞ^ƚĂƚĞŽĨ&ůŽƌŝĚĂƵŝůĚŝŶŐŽĚĞƐ͗ ϭ͘ ^ͬ^/ϳͲϭϲ͕DŝŶŝŵƵŵĞƐŝŐŶ>ŽĂĚƐĨŽƌƵŝůĚŝŶŐƐĂŶĚKƚŚĞƌ^ƚƌƵĐƚƵƌĞƐ͕ďLJŵĞƌŝĐĂŶ^ŽĐŝĞƚLJŽĨŝǀŝůŶŐŝŶĞĞƌƐϮ͘ ϮϬϮϬ&ͲƵŝůĚŝŶŐ͕ϳƚŚĚŝƚŝŽŶ͕ĂƐĞĚŽŶϮϬϭϴ/ŶƚĞƌŶĂƚŝŽŶĂůƵŝůĚŝŶŐŽĚĞϯ͘ ϮϬϮϬ&RͲZĞƐŝĚĞŶƚŝĂů͕ϳƚŚĚŝƚŝŽŶ͕ĂƐĞĚŽŶϮϬϭϴ/ŶƚĞƌŶĂƚŝŽŶĂůZĞƐŝĚĞŶƚŝĂůŽĚĞϰ͘ ϰϮϴ͕ĐĐĞƉƚĂŶĐĞƌŝƚĞƌŝĂĨŽƌDŽĚƵůĂƌ&ƌĂŵŝŶŐ^LJƐƚĞŵƐhƐĞĚƚŽ^ƵƉƉŽƌƚWŚŽƚŽǀŽůƚĂŝĐ;WsͿWĂŶĞůƐ͕EŽǀĞŵďĞƌϭ͕ϮϬϭϮďLJ/Ͳ^ϱ͘ ůƵŵŝŶƵŵĞƐŝŐŶDĂŶƵĂůϮϬϭϱ͕ďLJdŚĞůƵŵŝŶƵŵƐƐŽĐŝĂƚŝŽŶ͕/ŶĐ͘ϲ͘ E^/ͬtE^ͲϮϬϭϴ͕EĂƚŝŽŶĂůĞƐŝŐŶ^ƉĞĐŝĨŝĐĂƚŝŽŶĨŽƌtŽŽĚŽŶƐƚƌƵĐƚŝŽŶ͕ďLJƚŚĞŵĞƌŝĐĂŶtŽŽĚŽƵŶĐŝůĞƐŝŐŶƌŝƚĞƌŝĂ͗ZŝƐŬĂƚĞŐŽƌLJ//^ĞŝƐŵŝĐĞƐŝŐŶĂƚĞŐŽƌLJсͲdžƉŽƐƵƌĞĂƚĞŐŽƌLJс͕ΘĂƐŝĐtŝŶĚ^ƉĞĞĚ;ƵůƚŝŵĂƚĞͿƉĞƌ^ϳͲϭϲсϵϬŵƉŚƚŽϭϴϬŵƉŚ'ƌŽƵŶĚ^ŶŽǁ>ŽĂĚсϬƚŽϲϬ;ƉƐĨͿdŚŝƐůĞƚƚĞƌĐĞƌƚŝĨŝĞƐƚŚĂƚƚŚĞůŽĂĚŝŶŐĐƌŝƚĞƌŝĂĂŶĚĚĞƐŝŐŶďĂƐŝƐĨŽƌƚŚĞĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵ^ƉĂŶdĂďůĞƐĂƌĞŝŶĐŽŵƉůŝĂŶĐĞǁŝƚŚƚŚĞĂďŽǀĞĐŽĚĞƐ͘/ĨLJŽƵŚĂǀĞĂŶLJƋƵĞƐƚŝŽŶƐŽŶƚŚĞĂďŽǀĞ͕ĚŽŶŽƚŚĞƐŝƚĂƚĞƚŽĐĂůů͘WƌĞƉĂƌĞĚďLJ͗W^͕/ŶĐ͘ʹ^ƚƌƵĐƚƵƌĂůŶŐŝŶĞĞƌƐZŽƐĞǀŝůůĞ͕DĂLJϮϭ͕ϮϬϮϭW^͕/ŶĐ͘ʹ^ƚƌƵĐƚƵƌĂůŶŐŝŶĞĞƌƐŚĂƐƉƌŽǀŝĚĞĚĞŶŐŝŶĞĞƌŝŶŐĂŶĚƐƉĂŶƚĂďůĞƐĨŽƌƚŚĞĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵ͕ĂƐƉƌĞƐĞŶƚĞĚŝŶW^ZĞƉŽƌƚηϮϬϭϱͲϬϱϴϴϰ,'͘Ϭϳ͘Ϭϭ͕ΗŶŐŝŶĞĞƌŝŶŐĞƌƚŝĨŝĐĂƚŝŽŶĨŽƌƚŚĞĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵĨŽƌ'ĂďůĞĂŶĚ,ŝƉZŽŽĨƐΗ͘ůůŝŶĨŽƌŵĂƚŝŽŶ͕ĚĂƚĂ͕ĂŶĚĂŶĂůLJƐŝƐƚŚĞƌĞŝŶĂƌĞďĂƐĞĚŽŶ͕ĂŶĚĐŽŵƉůLJǁŝƚŚ͕ƚŚĞĨŽůůŽǁŝŶŐďƵŝůĚŝŶŐĐŽĚĞƐĂŶĚƚLJƉŝĐĂůƐƉĞĐŝĨŝĐĂƚŝŽŶƐ͗ZĞ͗ZĞƉŽƌƚηϮϬϭϱͲϬϱϴϴϰ,'͘Ϭϳ͘ϬϭʹĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵĨŽƌ'ĂďůĞĂŶĚ,ŝƉZŽŽĨƐEXP. 02/28/2023ZACHERPAULK.ENSECILARIDAOLFNOISSEFORP LENGINEERSTATE OFNo. 7352205/21/2021THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY PAULK. ZACHER, PE ON 05/21/2021 USING A SHA-1 AUTHENTICATION CODE.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNEDAND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.