HomeMy WebLinkAbout2203173-1d compaction signedHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
KSM JOB #:2203173-1d/NE/dc
NUC #528
Nuc Model:MC-1DR-P
Nuc Serial #:MD049528
763 Altura Street
Lot 18
Port St. Lucie, Florida
Compacted Foundation Fill
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F)
PERCENT
COMPACTION
1 S.E.0" - 12"40+ D 109.2 113.6 96.1%
2 S.W."40+ D 109.6 "96.5%
3 Center "40+ D 110.6 "97.4%
4 N.W."40+ D 108.1 "95.2%
5 N.E."40+ D 110.3 "97.1%
Proctor Optimum Moisture:
Proctor Max. Dry Density: P.C.F.
@ Test Locations the Density &
Penetrometer readings indicate the
Degree of Compaction Meets
3/28/2022
ITEM TESTED:
JOB LOCATION:
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
DATE TESTED:March 28, 2022
PERMIT #:21040108
CONTRACTOR:Adams Homes
TEST LOCATION
OF SAMPLE
Soil Description:
Respectfully Submitted:
In Place Moisture:
9.2 %
10 %
113.6
Minimum Requirement
For a Staked Foundation
Disclaimer:Contractor is responsible to maintain the tested area in
the condition that KSM completed the indicated passed
compaction test.KSM is not responsible if the tested area has
been altered from the approved inspected condition.
Eric A. McAra, P.E. Office Manager
PE # 69841
Email to: todd.masters@adamshomes.com
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE
Brown Sand With Clay And Shell Fragments
108.0
109.0
110.0
111.0
112.0
113.0
114.0
115.0
5 6 7 8 9 10 11 12 13
W
E
I
G
H
T
P
C
F
D
R
Y
Moisture -% of Dry Weight